Skip to main content
Erschienen in: European Radiology 5/2004

01.05.2004 | Musculoskeletal

Ultrasound during dissection of cadaveric specimens: a new method for obtaining ultrasound–anatomic correlations in musculoskeletal radiology

verfasst von: Michel De Maeseneer, Tjeerd Jager, Kurt Vanderdood, Peter Van Roy, Maryam Shahabpour, Stefaan Marcelis

Erschienen in: European Radiology | Ausgabe 5/2004

Einloggen, um Zugang zu erhalten

Abstract

We report a new technique for ultrasound–anatomic correlations consisting of dissection of embalmed specimens during ultrasound examination. Our method consists of performing ultrasound during the different stages of dissection. The technique was developed by making observations of selected structures in two embalmed and two non-embalmed cadaver hands. The image quality was subjectively graded by consensus of two investigators, before and after denudation of the selected structures of the hand. As an example, the technique is demonstrated for the flexors at the metacarpophalangeal joint level, the extensor complex at the level of the proximal phalanx, and the dorsal hood of the second to fourth fingers. Before dissection the image quality in fresh specimens was graded moderate, and in embalmed specimens good. After dissection the image quality was good in fresh specimens and excellent in embalmed specimens. Our method is simple and does not require sophisticated material. Our results indicate that embalmed specimens could be better than non-embalmed specimens, because of the presence of artefacts in the non-embalmed specimens (gas deposits). The described methodology can yield excellent results regarding precise identification of different interfaces and structures, as observed at ultrasound.
Literatur
1.
Zurück zum Zitat Hodler J, Trudell D, Kang HS, Kjellin I, Resnick D (1992) Inexpensive technique for performing magnetic resonance-pathologic correlation in cadavers. Invest Radiol 27:323–325PubMed Hodler J, Trudell D, Kang HS, Kjellin I, Resnick D (1992) Inexpensive technique for performing magnetic resonance-pathologic correlation in cadavers. Invest Radiol 27:323–325PubMed
2.
Zurück zum Zitat De Maeseneer M, De Wilde V, Gosselin R, Osteaux M (2003) The use of phantoms and tissue simulating test objects in the evaluation of imaging methods. JBR-BTR 86:3–5 De Maeseneer M, De Wilde V, Gosselin R, Osteaux M (2003) The use of phantoms and tissue simulating test objects in the evaluation of imaging methods. JBR-BTR 86:3–5
3.
Zurück zum Zitat Rauschning W (1983) Computed tomography and cryomicrotomy of lumbar spine specimens: a new technique for multiplanar anatomic correlation. Spine 8:170–180PubMed Rauschning W (1983) Computed tomography and cryomicrotomy of lumbar spine specimens: a new technique for multiplanar anatomic correlation. Spine 8:170–180PubMed
4.
Zurück zum Zitat De Maeseneer M, Lenchik L, Starok M, Pedowitz R, Trudell D, Resnick D (1998) Normal and abnormal medial meniscocapsular structures: MR imaging and sonography in cadavers. AJR Am J Roentgenol 171:969–976 De Maeseneer M, Lenchik L, Starok M, Pedowitz R, Trudell D, Resnick D (1998) Normal and abnormal medial meniscocapsular structures: MR imaging and sonography in cadavers. AJR Am J Roentgenol 171:969–976
5.
Zurück zum Zitat Trappeniers L, De Maeseneer M, Van Roy P, Chaskis C, Osteaux M (2003) Peroneal nerve injury in three patients with knee trauma: MR imaging and correlation with anatomic findings in volunteers and anatomic specimens. Eur Radiol 13:1722–1727CrossRefPubMed Trappeniers L, De Maeseneer M, Van Roy P, Chaskis C, Osteaux M (2003) Peroneal nerve injury in three patients with knee trauma: MR imaging and correlation with anatomic findings in volunteers and anatomic specimens. Eur Radiol 13:1722–1727CrossRefPubMed
6.
Zurück zum Zitat Hauger O, Chung CB, Lektrakul N, Botte MJ, Trudell D, Boutin RD, Resnick D (2000) Pulley system in the fingers: normal anatomy and simulated lesions in cadavers at MR imaging, CT and US with and without contrast material distension of the tendon sheath. Radiology 217:201–212PubMed Hauger O, Chung CB, Lektrakul N, Botte MJ, Trudell D, Boutin RD, Resnick D (2000) Pulley system in the fingers: normal anatomy and simulated lesions in cadavers at MR imaging, CT and US with and without contrast material distension of the tendon sheath. Radiology 217:201–212PubMed
7.
Zurück zum Zitat Landsmeer JM (ed) (1976) Atlas of anatomy of the hand. Churchill Livingstone, Edinburgh, London, New York, pp 179–295 Landsmeer JM (ed) (1976) Atlas of anatomy of the hand. Churchill Livingstone, Edinburgh, London, New York, pp 179–295
Metadaten
Titel
Ultrasound during dissection of cadaveric specimens: a new method for obtaining ultrasound–anatomic correlations in musculoskeletal radiology
verfasst von
Michel De Maeseneer
Tjeerd Jager
Kurt Vanderdood
Peter Van Roy
Maryam Shahabpour
Stefaan Marcelis
Publikationsdatum
01.05.2004
Erschienen in
European Radiology / Ausgabe 5/2004
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-2216-x

Weitere Artikel der Ausgabe 5/2004

European Radiology 5/2004 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.