Skip to main content
Erschienen in: European Radiology 5/2005

01.05.2005 | Chest

Value of high-resolution ultrasound in detecting a pneumothorax

verfasst von: Myung Jin Chung, Jin Mo Goo, Jung-Gi Im, Jae Min Cho, Sung Bum Cho, Seog Joon Kim

Erschienen in: European Radiology | Ausgabe 5/2005

Einloggen, um Zugang zu erhalten

Abstract

This study was designed to compare the detectability of high-resolution ultrasound (HRUS) and bedside chest radiography (CR) for a pneumothorax. During the last 14 months, 97 consecutive patients who were admitted to our institute to undergo a transthoracic needle aspiration and biopsy (TNAB) of the lung were included. Both HRUS and CR were performed immediately after the TNAB procedure. The HRUS images were saved in sequence using the cine-review mode and displayed as an animation on a workstation. Four radiologists independently analyzed both HRUS images and a soft copy of the CR on a diagnostic monitor and identified the pneumothorax. With CT as the reference standard, statistical parameters were calculated. From 97 patients, 35 pneumothorax cases were found on CT after the TNAB. The sensitivities in detecting the pneumothorax were 80 and 47% in HRUS and CR, respectively. The specificities were 94 and 94%. The diagnostic accuracies were 89 and 77%. The inter-observer agreement was excellent (κ=0.85) in the HRUS images and moderate (κ=0.49) in the CR. The results of this study suggest that HRUS is a more sensitive and confident method for diagnosing a pneumothorax when compared to bedside chest radiography.
Literatur
1.
Zurück zum Zitat Kirkpatrick AW, Ng AK, Dulchavsky SA, Lyburn I, Harris A, Torregianni W, Simons RK, Nicolaou S (2001) Sonographic diagnosis of a pneumothorax inapparent on plain radiography: confirmation by computed tomography. J Trauma 50:750–752PubMed Kirkpatrick AW, Ng AK, Dulchavsky SA, Lyburn I, Harris A, Torregianni W, Simons RK, Nicolaou S (2001) Sonographic diagnosis of a pneumothorax inapparent on plain radiography: confirmation by computed tomography. J Trauma 50:750–752PubMed
2.
Zurück zum Zitat Chiles C, Ravin CE (1986) Radiographic recognition of pneumothorax in the intensive care unit. Crit Care Med 19:906–910 Chiles C, Ravin CE (1986) Radiographic recognition of pneumothorax in the intensive care unit. Crit Care Med 19:906–910
3.
Zurück zum Zitat Tocino IM, Miller MH, Fairfax WR (1985) Distribution of pneumothorax in the supine and semirecumbent critically ill adult. Am J Roentgenol 144:901–905 Tocino IM, Miller MH, Fairfax WR (1985) Distribution of pneumothorax in the supine and semirecumbent critically ill adult. Am J Roentgenol 144:901–905
4.
Zurück zum Zitat Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMed Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMed
5.
Zurück zum Zitat Sistrom CL, Reiheld CT, Spencer BG, Wallace KK (1996) Detection and estimation of the volume of pneumothorax using real-time sonography. Am J Roentgenol 166:317–321 Sistrom CL, Reiheld CT, Spencer BG, Wallace KK (1996) Detection and estimation of the volume of pneumothorax using real-time sonography. Am J Roentgenol 166:317–321
6.
Zurück zum Zitat Rantanen NW (1986) Diseases of the thorax. Vet Clin North Am Equine Pract 2:49–66PubMed Rantanen NW (1986) Diseases of the thorax. Vet Clin North Am Equine Pract 2:49–66PubMed
7.
Zurück zum Zitat Wernecke K, Galanski M, Peters PE, Hansen J (1987) Pneumothorax: evaluation by ultrasound—preliminary results. J Thorac Imaging 2:76–78PubMed Wernecke K, Galanski M, Peters PE, Hansen J (1987) Pneumothorax: evaluation by ultrasound—preliminary results. J Thorac Imaging 2:76–78PubMed
8.
Zurück zum Zitat Targhetta R, Bourgeois JM, Balmes P (1990) Echography of pneumothorax. Rev Mal Respir 7:575–579PubMed Targhetta R, Bourgeois JM, Balmes P (1990) Echography of pneumothorax. Rev Mal Respir 7:575–579PubMed
9.
Zurück zum Zitat Targhetta R, Bourgeois JM, Chavagneux R, Balmes P (1992) Diagnosis of pneumothorax by ultrasound immediately after ultrasonically guided aspiration biopsy. Chest 101:855–856PubMed Targhetta R, Bourgeois JM, Chavagneux R, Balmes P (1992) Diagnosis of pneumothorax by ultrasound immediately after ultrasonically guided aspiration biopsy. Chest 101:855–856PubMed
10.
Zurück zum Zitat Targhetta R, Bourgeois JM, Chavagneux R, Coste E, Amy D, Balmes P, Pourcelot L (1993) Ultrasonic signs of pneumothorax: preliminary work. J Clin Ultrasound 21:245–250PubMed Targhetta R, Bourgeois JM, Chavagneux R, Coste E, Amy D, Balmes P, Pourcelot L (1993) Ultrasonic signs of pneumothorax: preliminary work. J Clin Ultrasound 21:245–250PubMed
11.
Zurück zum Zitat Lichtenstein DA, Menu Y (1995) A bedside ultrasound sign ruling out pneumothorax in the critically ill. Lung sliding. Chest 108:1345–1348PubMed Lichtenstein DA, Menu Y (1995) A bedside ultrasound sign ruling out pneumothorax in the critically ill. Lung sliding. Chest 108:1345–1348PubMed
12.
Zurück zum Zitat Sistrom CL, Reiheld CT, Gay SB, Wallace KK (1996) Detection and estimation of the volume of pneumothorax using real-time sonography: efficacy determined by receiver operating characteristic analysis. Am J Roentgenol 166:317–321 Sistrom CL, Reiheld CT, Gay SB, Wallace KK (1996) Detection and estimation of the volume of pneumothorax using real-time sonography: efficacy determined by receiver operating characteristic analysis. Am J Roentgenol 166:317–321
13.
Zurück zum Zitat Lichtenstein D, Meziere G, Biderman P, Gepner A (1999) The comet-tail artifact: an ultrasound sign ruling out pneumothorax. Intensive Care Med 25:383–388CrossRefPubMed Lichtenstein D, Meziere G, Biderman P, Gepner A (1999) The comet-tail artifact: an ultrasound sign ruling out pneumothorax. Intensive Care Med 25:383–388CrossRefPubMed
14.
Zurück zum Zitat Lichtenstein D, Meziere G, Biderman P, Gepner A (2000) The “lung point”: an ultrasound sign specific to pneumothorax. Intensive Care Med 26:1434–1440CrossRefPubMed Lichtenstein D, Meziere G, Biderman P, Gepner A (2000) The “lung point”: an ultrasound sign specific to pneumothorax. Intensive Care Med 26:1434–1440CrossRefPubMed
15.
Zurück zum Zitat Dulchavsky SA, Schwarz KL, Kirkpatrick AW, Billica RD, Williams DR, Diebel LN, Campbell MR, Sargysan AE, Hamilton DR (2001) Prospective evaluation of thoracic ultrasound in the detection of pneumothorax. J Trauma 50:201–205PubMed Dulchavsky SA, Schwarz KL, Kirkpatrick AW, Billica RD, Williams DR, Diebel LN, Campbell MR, Sargysan AE, Hamilton DR (2001) Prospective evaluation of thoracic ultrasound in the detection of pneumothorax. J Trauma 50:201–205PubMed
16.
Zurück zum Zitat Carr JJ, Reed JC, Choplin RH, Pope TL Jr, Case LD (1992) Plain and computed radiography for detecting experimentally induced pneumothorax in cadavers: implications for detection in patients. Radiology 183:193–199PubMed Carr JJ, Reed JC, Choplin RH, Pope TL Jr, Case LD (1992) Plain and computed radiography for detecting experimentally induced pneumothorax in cadavers: implications for detection in patients. Radiology 183:193–199PubMed
17.
Zurück zum Zitat Sargsyan AE, Hamilton DR, Nicolaou S, Kirkpatrick AW, Campbell MR, Billica RD, Dawson D, Williams DR, Melton SL, Beck G, Forkheim K, Dulchavsky SA (2001) Ultrasound evaluation of the magnitude of pneumothorax: a new concept. Am Surg 67:232–235PubMed Sargsyan AE, Hamilton DR, Nicolaou S, Kirkpatrick AW, Campbell MR, Billica RD, Dawson D, Williams DR, Melton SL, Beck G, Forkheim K, Dulchavsky SA (2001) Ultrasound evaluation of the magnitude of pneumothorax: a new concept. Am Surg 67:232–235PubMed
18.
Zurück zum Zitat Oikonomou A, Matzinger FR, Seely JM, Dennie CJ, Macleod PJ (2004) Ultrathin needle (25 G) aspiration lung biopsy: diagnostic accuracy and complication rates. Eur Radiol 14:375–382CrossRefPubMed Oikonomou A, Matzinger FR, Seely JM, Dennie CJ, Macleod PJ (2004) Ultrathin needle (25 G) aspiration lung biopsy: diagnostic accuracy and complication rates. Eur Radiol 14:375–382CrossRefPubMed
19.
Zurück zum Zitat Topal U, Ediz B (2003) Transthoracic needle biopsy: factors effecting risk of pneumothorax. Eur J Radiol 48:263–267CrossRefPubMed Topal U, Ediz B (2003) Transthoracic needle biopsy: factors effecting risk of pneumothorax. Eur J Radiol 48:263–267CrossRefPubMed
20.
Zurück zum Zitat Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD (2003) CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology 229:475–481PubMed Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD (2003) CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology 229:475–481PubMed
21.
Zurück zum Zitat Anderson JM, Murchison J, Patel D (2003) CT-guided lung biopsy: factors influencing diagnostic yield and complication rate. Clin Radiol 58:791–797 Anderson JM, Murchison J, Patel D (2003) CT-guided lung biopsy: factors influencing diagnostic yield and complication rate. Clin Radiol 58:791–797
22.
Zurück zum Zitat Lichtenstein D, Goldstein I, Mourgeon E, Cluzel P, Grenier P, Rouby JJ (2004) Comparative diagnostic performances of auscultation, chest radiography, and lung ultrasonography in acute respiratory distress syndrome. Anesthesiology 100:9–15CrossRefPubMed Lichtenstein D, Goldstein I, Mourgeon E, Cluzel P, Grenier P, Rouby JJ (2004) Comparative diagnostic performances of auscultation, chest radiography, and lung ultrasonography in acute respiratory distress syndrome. Anesthesiology 100:9–15CrossRefPubMed
Metadaten
Titel
Value of high-resolution ultrasound in detecting a pneumothorax
verfasst von
Myung Jin Chung
Jin Mo Goo
Jung-Gi Im
Jae Min Cho
Sung Bum Cho
Seog Joon Kim
Publikationsdatum
01.05.2005
Erschienen in
European Radiology / Ausgabe 5/2005
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2518-7

Weitere Artikel der Ausgabe 5/2005

European Radiology 5/2005 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.