Skip to main content
Erschienen in: European Radiology 4/2005

01.04.2005 | Cardiac

Right ventricular function late after total repair of tetralogy of Fallot

verfasst von: Alexander van Straten, Hubert W. Vliegen, Mark G. Hazekamp, Albert de Roos

Erschienen in: European Radiology | Ausgabe 4/2005

Einloggen, um Zugang zu erhalten

Abstract

Over the past decades, life expectancy in patients with congenital heart disease has increased dramatically. However, serious complications may develop late after total repair in infancy. These complications are usually the result of longstanding pulmonary regurgitation, which leads to dilatation of the right ventricle and an increased risk for severe arrhythmias. Therefore lifelong follow-up in these patients is required. Cardiac magnetic resonance imaging is the current imaging tool of choice because it offers superior imaging quality and enables accurate quantification of functional parameters such as flow volumes and systolic and diastolic performance.
Literatur
1.
Zurück zum Zitat Gatzoulis MA, Till JA, Somerville J et al (1995) Mechanoelectrical interaction in tetralogy of Fallot. QRS prolongation relates to right ventricular size and predicts malignant ventricular arrhythmias and sudden death. Circulation 92:231–237PubMed Gatzoulis MA, Till JA, Somerville J et al (1995) Mechanoelectrical interaction in tetralogy of Fallot. QRS prolongation relates to right ventricular size and predicts malignant ventricular arrhythmias and sudden death. Circulation 92:231–237PubMed
2.
Zurück zum Zitat Jonsson H, Ivert T, Brodin LA (1995) Echocardiographic findings in 83 patients 13–26 years after intracardiac repair of tetralogy of Fallot. Eur Heart J 16:1255–1263 Jonsson H, Ivert T, Brodin LA (1995) Echocardiographic findings in 83 patients 13–26 years after intracardiac repair of tetralogy of Fallot. Eur Heart J 16:1255–1263
3.
Zurück zum Zitat Greenberg SB, Faerber EN, Balsara RK (1995) Tetralogy of Fallot: diagnostic imaging after palliative and corrective surgery. J Thorac Imaging 10:26–35 Greenberg SB, Faerber EN, Balsara RK (1995) Tetralogy of Fallot: diagnostic imaging after palliative and corrective surgery. J Thorac Imaging 10:26–35
4.
Zurück zum Zitat Marx GR, Geva T (1998) MRI and echocardiography in children: how do they compare? Semin Roentgenol 33:281–292 Marx GR, Geva T (1998) MRI and echocardiography in children: how do they compare? Semin Roentgenol 33:281–292
5.
Zurück zum Zitat Hartnell GG, Notarianni M (1998) MRI and echocardiography: how do they compare in adults? Semin Roentgenol 33:252–261 Hartnell GG, Notarianni M (1998) MRI and echocardiography: how do they compare in adults? Semin Roentgenol 33:252–261
6.
Zurück zum Zitat de Roos A, Doornbos J, van der Wall EE et al. (1995) Magnetic resonance of the heart and great vessels. Nat Med 1:711–713 de Roos A, Doornbos J, van der Wall EE et al. (1995) Magnetic resonance of the heart and great vessels. Nat Med 1:711–713
7.
Zurück zum Zitat Ferencz C, Rubin JD, McCarter RJ et al. (1985) Congenital heart disease: prevalence at livebirth. The Baltimore–Washington Infant Study. Am J Epidemiol 121:31–36PubMed Ferencz C, Rubin JD, McCarter RJ et al. (1985) Congenital heart disease: prevalence at livebirth. The Baltimore–Washington Infant Study. Am J Epidemiol 121:31–36PubMed
8.
Zurück zum Zitat Pattynama PM, Lamb HJ, Van der Velde EA et al. (1993) Left ventricular measurements with cine and spin–echo MR imaging: a study of reproducibility with variance component analysis. Radiology 187:261–268 Pattynama PM, Lamb HJ, Van der Velde EA et al. (1993) Left ventricular measurements with cine and spin–echo MR imaging: a study of reproducibility with variance component analysis. Radiology 187:261–268
9.
Zurück zum Zitat Pattynama PM, Lamb HJ, Van der Velde EA et al. (1995) Reproducibility of MRI-derived measurements of right ventricular volumes and myocardial mass. Magn Reson Imaging 13:53–63CrossRefPubMed Pattynama PM, Lamb HJ, Van der Velde EA et al. (1995) Reproducibility of MRI-derived measurements of right ventricular volumes and myocardial mass. Magn Reson Imaging 13:53–63CrossRefPubMed
10.
Zurück zum Zitat Mogelvang J, Stubgaard M, Thomsen C et al. (1988) Evaluation of right ventricular volumes measured by magnetic resonance imaging. Eur Heart J 9:529–533PubMed Mogelvang J, Stubgaard M, Thomsen C et al. (1988) Evaluation of right ventricular volumes measured by magnetic resonance imaging. Eur Heart J 9:529–533PubMed
11.
Zurück zum Zitat Markiewicz W, Sechtem U, Higgins CB (1987) Evaluation of the right ventricle by magnetic resonance imaging. Am Heart J 113:8–15 Markiewicz W, Sechtem U, Higgins CB (1987) Evaluation of the right ventricle by magnetic resonance imaging. Am Heart J 113:8–15
12.
Zurück zum Zitat Helbing WA, Rebergen SA, Maliepaard C et al. (1995) Quantification of right ventricular function with magnetic resonance imaging in children with normal hearts and with congenital heart disease. Am Heart J 130:828–837PubMed Helbing WA, Rebergen SA, Maliepaard C et al. (1995) Quantification of right ventricular function with magnetic resonance imaging in children with normal hearts and with congenital heart disease. Am Heart J 130:828–837PubMed
13.
Zurück zum Zitat Dornier C, Somsen GA, Ivancevic MK et al. (2004) Comparison between tagged MRI and standard cine MRI for evaluation of left ventricular ejection fraction. Eur Radiol 14:1348–1352 Dornier C, Somsen GA, Ivancevic MK et al. (2004) Comparison between tagged MRI and standard cine MRI for evaluation of left ventricular ejection fraction. Eur Radiol 14:1348–1352
14.
Zurück zum Zitat Helbing WA, Niezen RA, Le Cessie S et al. (1996) Right ventricular diastolic function in children with pulmonary regurgitation after repair of tetralogy of Fallot: volumetric evaluation by magnetic resonance velocity mapping. J Am Coll Cardiol 28:1827–1835 Helbing WA, Niezen RA, Le Cessie S et al. (1996) Right ventricular diastolic function in children with pulmonary regurgitation after repair of tetralogy of Fallot: volumetric evaluation by magnetic resonance velocity mapping. J Am Coll Cardiol 28:1827–1835
15.
Zurück zum Zitat Gatzoulis MA, Clark AL, Cullen S et al. (1995) Right ventricular diastolic function 15 to 35 years after repair of tetralogy of Fallot. Restrictive physiology predicts superior exercise performance. Circulation 91:1775–1781 Gatzoulis MA, Clark AL, Cullen S et al. (1995) Right ventricular diastolic function 15 to 35 years after repair of tetralogy of Fallot. Restrictive physiology predicts superior exercise performance. Circulation 91:1775–1781
16.
Zurück zum Zitat Gatzoulis MA, Norgard G, Redington AN (1998) Biventricular long axis function after repair of tetralogy of Fallot. Pediatr Cardiol 19:128–132 Gatzoulis MA, Norgard G, Redington AN (1998) Biventricular long axis function after repair of tetralogy of Fallot. Pediatr Cardiol 19:128–132
17.
Zurück zum Zitat Mandinov L, Eberli FR, Seiler C et al. (2000) Diastolic heart failure. Cardiovasc Res 45:813–825 Mandinov L, Eberli FR, Seiler C et al. (2000) Diastolic heart failure. Cardiovasc Res 45:813–825
18.
Zurück zum Zitat Redington AN, Penny D, Rigby ML et al. (1992) Antegrade diastolic pulmonary arterial flow as a marker of right ventricular restriction after complete repair of pulmonary atresia with intact septum and critical pulmonary valvar stenosis. Cardiol Young 2:382–386 Redington AN, Penny D, Rigby ML et al. (1992) Antegrade diastolic pulmonary arterial flow as a marker of right ventricular restriction after complete repair of pulmonary atresia with intact septum and critical pulmonary valvar stenosis. Cardiol Young 2:382–386
19.
Zurück zum Zitat Wintersperger BJ, Nikolaou K, Dietrich O et al. (2003) Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm. Eur Radiol 13:1931–1936CrossRefPubMed Wintersperger BJ, Nikolaou K, Dietrich O et al. (2003) Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm. Eur Radiol 13:1931–1936CrossRefPubMed
20.
Zurück zum Zitat Oechslin EN, Harrison DA, Harris L et al. (1999) Reoperation in adults with repair of tetralogy of Fallot: indications and outcomes. J Thorac Cardiovasc Surg 118:245–251PubMed Oechslin EN, Harrison DA, Harris L et al. (1999) Reoperation in adults with repair of tetralogy of Fallot: indications and outcomes. J Thorac Cardiovasc Surg 118:245–251PubMed
21.
Zurück zum Zitat d’Udekem Y, Rubay J, Shango-Lody P et al. (1998) Late homograft valve insertion after transannular patch repair of tetralogy of Fallot. J Heart Valve Dis 7:450–454 d’Udekem Y, Rubay J, Shango-Lody P et al. (1998) Late homograft valve insertion after transannular patch repair of tetralogy of Fallot. J Heart Valve Dis 7:450–454
22.
Zurück zum Zitat Davlouros PA, Kilner PJ, Hornung TS et al. (2002) right ventricular function in adults with repaired tetralogy of Fallot assessed with cardiovascular magnetic resonance imaging: detrimental role of right ventricular outflow aneurysms or akinesia and adverse right-to-left ventricular interaction. J Am Coll Cardiol 40:2044–2052 Davlouros PA, Kilner PJ, Hornung TS et al. (2002) right ventricular function in adults with repaired tetralogy of Fallot assessed with cardiovascular magnetic resonance imaging: detrimental role of right ventricular outflow aneurysms or akinesia and adverse right-to-left ventricular interaction. J Am Coll Cardiol 40:2044–2052
23.
Zurück zum Zitat d’Udekem Y, Ovaert C, Grandjean F et al. (2000) Tetralogy of Fallot: transannular and right ventricular patching equally affect late functional status. Circulation 102:III116–III122 d’Udekem Y, Ovaert C, Grandjean F et al. (2000) Tetralogy of Fallot: transannular and right ventricular patching equally affect late functional status. Circulation 102:III116–III122
24.
Zurück zum Zitat Therrien J, Siu SC, Harris L et al. (2001) Impact of pulmonary valve replacement on arrhythmia propensity late after repair of tetralogy of Fallot. Circulation 103:2489–2494 Therrien J, Siu SC, Harris L et al. (2001) Impact of pulmonary valve replacement on arrhythmia propensity late after repair of tetralogy of Fallot. Circulation 103:2489–2494
25.
Zurück zum Zitat Harrison DA, Harris L, Siu SC et al. (1997) Sustained ventricular tachycardia in adult patients late after repair of tetralogy of Fallot. J Am Coll Cardiol 30:1368–1373 Harrison DA, Harris L, Siu SC et al. (1997) Sustained ventricular tachycardia in adult patients late after repair of tetralogy of Fallot. J Am Coll Cardiol 30:1368–1373
26.
Zurück zum Zitat Discigil B, Dearani JA, Puga FJ et al. (2001) Late pulmonary valve replacement after repair of tetralogy of Fallot. J Thorac Cardiovasc Surg 121:344–351CrossRefPubMed Discigil B, Dearani JA, Puga FJ et al. (2001) Late pulmonary valve replacement after repair of tetralogy of Fallot. J Thorac Cardiovasc Surg 121:344–351CrossRefPubMed
27.
Zurück zum Zitat Vliegen HW, Van Straten A, de Roos A et al. (2002) Magnetic resonance imaging to assess the hemodynamic effects of pulmonary valve replacement in adults late after repair of tetralogy of Fallot. Circulation 106:1703–1707 Vliegen HW, Van Straten A, de Roos A et al. (2002) Magnetic resonance imaging to assess the hemodynamic effects of pulmonary valve replacement in adults late after repair of tetralogy of Fallot. Circulation 106:1703–1707
28.
Zurück zum Zitat Niwaya K, Knott-Craig CJ, Lane MM et al. (1999) Cryopreserved homograft valves in the pulmonary position: risk analysis for intermediate-term failure. J Thorac Cardiovasc Surg 117:141–146 Niwaya K, Knott-Craig CJ, Lane MM et al. (1999) Cryopreserved homograft valves in the pulmonary position: risk analysis for intermediate-term failure. J Thorac Cardiovasc Surg 117:141–146
29.
Zurück zum Zitat Van Straten A, Vliegen HW, Hazekamp MG et al. (2004) Follow-up of right ventricular function after pulmonary valve replacement in adult tetralogy of Fallot patients. Radiology, in press Van Straten A, Vliegen HW, Hazekamp MG et al. (2004) Follow-up of right ventricular function after pulmonary valve replacement in adult tetralogy of Fallot patients. Radiology, in press
30.
Zurück zum Zitat Van Straten A, Vliegen HW, Roes SD et al. (2002) Timecourse of systolic and diastolic function improvement after pulmonary valve replacement in adult patients late after repair of tetralogy of Fallot. RSNA, abstract Van Straten A, Vliegen HW, Roes SD et al. (2002) Timecourse of systolic and diastolic function improvement after pulmonary valve replacement in adult patients late after repair of tetralogy of Fallot. RSNA, abstract
31.
Zurück zum Zitat Razavi R, Hill DL, Keevil SF et al. (2003) Cardiac catheterisation guided by MRI in children and adults with congenital heart disease. Lancet 362:1877–1882CrossRef Razavi R, Hill DL, Keevil SF et al. (2003) Cardiac catheterisation guided by MRI in children and adults with congenital heart disease. Lancet 362:1877–1882CrossRef
32.
Zurück zum Zitat Kuehne T, Saeed M, Higgins CB et al. (2003) Endovascular stents in pulmonary valve and artery in swine: feasibility study of MR imaging-guided deployment and postinterventional assessment. Radiology 226:475–481 Kuehne T, Saeed M, Higgins CB et al. (2003) Endovascular stents in pulmonary valve and artery in swine: feasibility study of MR imaging-guided deployment and postinterventional assessment. Radiology 226:475–481
33.
Zurück zum Zitat Bakker CJ, Smits HF, Bos C et al. (1998) MR-guided balloon angioplasty: in vitro demonstration of the potential of MRI for guiding, monitoring, and evaluating endovascular interventions. J Magn Reson Imaging 8:245–250 Bakker CJ, Smits HF, Bos C et al. (1998) MR-guided balloon angioplasty: in vitro demonstration of the potential of MRI for guiding, monitoring, and evaluating endovascular interventions. J Magn Reson Imaging 8:245–250
34.
Zurück zum Zitat Yang X, Atalar E, Zerhouni EA (1999) Intravascular MR imaging and intravascular MR-guided interventions. Int J Cardiovasc Interv 2:85–96 Yang X, Atalar E, Zerhouni EA (1999) Intravascular MR imaging and intravascular MR-guided interventions. Int J Cardiovasc Interv 2:85–96
35.
Zurück zum Zitat Wong EY, Zhang Q, Duerk JL et al. (2000) An optical system for wireless detuning of parallel resonant circuits. J Magn Reson Imaging 12:632–638 Wong EY, Zhang Q, Duerk JL et al. (2000) An optical system for wireless detuning of parallel resonant circuits. J Magn Reson Imaging 12:632–638
Metadaten
Titel
Right ventricular function late after total repair of tetralogy of Fallot
verfasst von
Alexander van Straten
Hubert W. Vliegen
Mark G. Hazekamp
Albert de Roos
Publikationsdatum
01.04.2005
Erschienen in
European Radiology / Ausgabe 4/2005
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2574-z

Weitere Artikel der Ausgabe 4/2005

European Radiology 4/2005 Zur Ausgabe

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.