Skip to main content
Erschienen in: European Radiology 10/2008

01.10.2008 | Magnetic Resonance

Comparison of image quality in magnetic resonance imaging of the knee at 1.5 and 3.0 Tesla using 32-channel receiver coils

verfasst von: F. Schoth, N. Kraemer, T. Niendorf, C. Hohl, R. W. Gunther, G. A. Krombach

Erschienen in: European Radiology | Ausgabe 10/2008

Einloggen, um Zugang zu erhalten

Abstract

We examined to what degree the visualization of anatomic structures in the human knee is improved using 3.0-T magnetic resonance imaging (MRI) and many element RF receive coils as compared to 1.5 T. We imaged 20 knees at 1.5 and 3.0 T using T2-weighted STIR, T2-weighted gradient echo, T1-weighted spin-echo, true-FISP and T2-weighted fast spin echo techniques in conjunction with 32-element RF coil arrays. The 3.0-T examination was considerably faster than its 1.5-T counterpart. A superior subjective visibility at 3.0 T vs 1.5 T was found in 27 of 50 evaluated structures (meniscus, ligaments) with the exception of true-FISP techniques. The 3.0-T examination provided a better visibility (evaluated by blinded consensus-reading by two radiologists) of small structures such as the ligamentum transversum genu. Also, cartilage was better delineated at 3.0 T. A 23% increased average signal-to-noise ratio as assessed using a temporal filter was observed at 3.0 T as compared to 1.5 T. At 3.0 T, imaging of the human knee is faster and results in a subjective visibility of anatomic structures that is superior to and competitive with 1.5 T.
Literatur
1.
Zurück zum Zitat Jackson JL, O’Malley PG, Kroenke K (2003) Evaluation of acute knee pain in primary care. Ann Intern Med 139:575–588PubMed Jackson JL, O’Malley PG, Kroenke K (2003) Evaluation of acute knee pain in primary care. Ann Intern Med 139:575–588PubMed
2.
Zurück zum Zitat Kuikka PI, Kiuru MJ, Niva MH, Kroger H, Pihlajamaki HK (2006) Sensitivity of routine 1.0-Tesla magnetic resonance imaging versus arthroscopy as gold standard in fresh traumatic chondral lesions of the knee in young adults. Arthroscopy 22:1033–1039PubMedCrossRef Kuikka PI, Kiuru MJ, Niva MH, Kroger H, Pihlajamaki HK (2006) Sensitivity of routine 1.0-Tesla magnetic resonance imaging versus arthroscopy as gold standard in fresh traumatic chondral lesions of the knee in young adults. Arthroscopy 22:1033–1039PubMedCrossRef
3.
Zurück zum Zitat Vaz CE, Camargo OP, Santana PJ, Valezi AC (2005) Accuracy of magnetic resonance in identifying traumatic. Clinics 60:445–450PubMedCrossRef Vaz CE, Camargo OP, Santana PJ, Valezi AC (2005) Accuracy of magnetic resonance in identifying traumatic. Clinics 60:445–450PubMedCrossRef
4.
Zurück zum Zitat Van Dyck P, Gielen J, D’Anvers J, Vanhoenacker F, Dossche L, Van Gestel J, Parizel PM (2007) MR diagnosis of meniscal tears of the knee: analysis of error patterns. Arch Orthop Trauma Surg 127:849–854PubMedCrossRef Van Dyck P, Gielen J, D’Anvers J, Vanhoenacker F, Dossche L, Van Gestel J, Parizel PM (2007) MR diagnosis of meniscal tears of the knee: analysis of error patterns. Arch Orthop Trauma Surg 127:849–854PubMedCrossRef
5.
Zurück zum Zitat Makdissi M, Eriksson KO, Morris HG, Young DA (2006) MRI-negative bucket-handle tears of the lateral meniscus in athletes: a case series. Knee Surg Sports Traumatol Arthrosc 14:1012–1016PubMedCrossRef Makdissi M, Eriksson KO, Morris HG, Young DA (2006) MRI-negative bucket-handle tears of the lateral meniscus in athletes: a case series. Knee Surg Sports Traumatol Arthrosc 14:1012–1016PubMedCrossRef
6.
Zurück zum Zitat Mosher TJ (2006) Musculoskeletal imaging at 3T: Current techniques and future applications. Magn Reson Imaging Clin N Am 14:63–76PubMedCrossRef Mosher TJ (2006) Musculoskeletal imaging at 3T: Current techniques and future applications. Magn Reson Imaging Clin N Am 14:63–76PubMedCrossRef
7.
Zurück zum Zitat Pakin SK, Cavalcanti C, La Rocca R, Schweitzer ME, Regatte RR (2006) Ultra-high-field MRI of knee joint at 7.0T: preliminary experience. Acad Radiol 13:1135–1142PubMedCrossRef Pakin SK, Cavalcanti C, La Rocca R, Schweitzer ME, Regatte RR (2006) Ultra-high-field MRI of knee joint at 7.0T: preliminary experience. Acad Radiol 13:1135–1142PubMedCrossRef
8.
Zurück zum Zitat Abramowitz M, Stegun I (1970) Handbook of mathematical functions 9th edn, Dover publications, Inc. p 932 Abramowitz M, Stegun I (1970) Handbook of mathematical functions 9th edn, Dover publications, Inc. p 932
9.
Zurück zum Zitat Sano RM (1988) NEMA standards. Performance standards for clinical magnetic resonance systems. In: Dixon RL (ed) MRI acceptance testing and quality control - the role of the clinical medical physicist. Medical Physics Publishing Corp, Madison, WI, pp 185–189 Sano RM (1988) NEMA standards. Performance standards for clinical magnetic resonance systems. In: Dixon RL (ed) MRI acceptance testing and quality control - the role of the clinical medical physicist. Medical Physics Publishing Corp, Madison, WI, pp 185–189
10.
Zurück zum Zitat Yang Y, Gu H, Zhan W, Xu S, Silbersweig DA, Stern E (2002) Simultaneous perfusion and BOLD imaging using reverse spiral scanning at 3T: characterization of functional contrast and susceptibility artifacts. Magn Reson Med 48:278–289PubMedCrossRef Yang Y, Gu H, Zhan W, Xu S, Silbersweig DA, Stern E (2002) Simultaneous perfusion and BOLD imaging using reverse spiral scanning at 3T: characterization of functional contrast and susceptibility artifacts. Magn Reson Med 48:278–289PubMedCrossRef
11.
Zurück zum Zitat Niitsu M, Nakai T, Ikeda K, Tang GY, Yoshioka H, Itai YK (2000) High resolution MR Imaging of the knee at 3.0T: comparison of SPGR and SSFP sequences. Acta Radiol 41:84–88PubMedCrossRef Niitsu M, Nakai T, Ikeda K, Tang GY, Yoshioka H, Itai YK (2000) High resolution MR Imaging of the knee at 3.0T: comparison of SPGR and SSFP sequences. Acta Radiol 41:84–88PubMedCrossRef
12.
Zurück zum Zitat Kornaat PR, Reeder SB, Koo S, Brittain JH, Yu H, Andriacchi TP, Gold GE (2005) MR imaging of articular cartilage at 1.5T and 3.0T: comparison of SPGR and SSFP sequences. Osteoarthr Cartil 13:338–344PubMedCrossRef Kornaat PR, Reeder SB, Koo S, Brittain JH, Yu H, Andriacchi TP, Gold GE (2005) MR imaging of articular cartilage at 1.5T and 3.0T: comparison of SPGR and SSFP sequences. Osteoarthr Cartil 13:338–344PubMedCrossRef
13.
Zurück zum Zitat Gold GE, Reeder SB, Yu H, Kornaat P, Shimakawa AS, Johnson JW, Pelc NJ, Beaulieu CF, Brittain JH (2006) Articular cartilage of the knee: rapid three-dimensional MR imaging at 3.0 T with IDEAL balanced steady-state free precession-initial experience. Radiology 240:546–551PubMedCrossRef Gold GE, Reeder SB, Yu H, Kornaat P, Shimakawa AS, Johnson JW, Pelc NJ, Beaulieu CF, Brittain JH (2006) Articular cartilage of the knee: rapid three-dimensional MR imaging at 3.0 T with IDEAL balanced steady-state free precession-initial experience. Radiology 240:546–551PubMedCrossRef
14.
Zurück zum Zitat Gold GE, Han E, Stainsby J, Wright G, Brittain J, Beaulieu C (2004) Musculosceletal MRI at 3.0 T: Relaxation times and image contrast. AJR Am J Roentgenol 183:343–351PubMed Gold GE, Han E, Stainsby J, Wright G, Brittain J, Beaulieu C (2004) Musculosceletal MRI at 3.0 T: Relaxation times and image contrast. AJR Am J Roentgenol 183:343–351PubMed
15.
Zurück zum Zitat Eckstein F, Charles C, Buck RJ, Kraus VB, Remmers AE, Hudelmaier M, Wirth W, Evel JL (2005) Accuracy and Precision of Quantitative Assessment of Cartilage Morphology by Magnetic Resonance Imaging at 3.0T. Arthritis Rheum 52:3132–3136PubMedCrossRef Eckstein F, Charles C, Buck RJ, Kraus VB, Remmers AE, Hudelmaier M, Wirth W, Evel JL (2005) Accuracy and Precision of Quantitative Assessment of Cartilage Morphology by Magnetic Resonance Imaging at 3.0T. Arthritis Rheum 52:3132–3136PubMedCrossRef
16.
Zurück zum Zitat Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P (1999) SENSE: sensitivity encoding for fast MRI. Magn Reson Med 42:952–962PubMedCrossRef Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P (1999) SENSE: sensitivity encoding for fast MRI. Magn Reson Med 42:952–962PubMedCrossRef
17.
Zurück zum Zitat Kellman P, McVeigh ER (2005) Image reconstruction in SNR units: A general method for SNR measurement. Magn Reson Med 54:1439–1447PubMedCrossRef Kellman P, McVeigh ER (2005) Image reconstruction in SNR units: A general method for SNR measurement. Magn Reson Med 54:1439–1447PubMedCrossRef
18.
Zurück zum Zitat Sijbers J, Scheunders P, Bonnet N, Van Dyck D, Raman E (1996) Quantification and improvement of the signal-to-noise-ratio in a magnetic resonance image acquisition procedure. Magn Reson Imaging 14:1157–1163PubMedCrossRef Sijbers J, Scheunders P, Bonnet N, Van Dyck D, Raman E (1996) Quantification and improvement of the signal-to-noise-ratio in a magnetic resonance image acquisition procedure. Magn Reson Imaging 14:1157–1163PubMedCrossRef
19.
Zurück zum Zitat Murphy BW, Carson PL, Ellis JH, Zhang YT, Hyde RJ, Chenevert TL (1993) Signal-to-noise measures for magnetic resonance imagers. Magn Reson Imaging 11:425–428PubMedCrossRef Murphy BW, Carson PL, Ellis JH, Zhang YT, Hyde RJ, Chenevert TL (1993) Signal-to-noise measures for magnetic resonance imagers. Magn Reson Imaging 11:425–428PubMedCrossRef
Metadaten
Titel
Comparison of image quality in magnetic resonance imaging of the knee at 1.5 and 3.0 Tesla using 32-channel receiver coils
verfasst von
F. Schoth
N. Kraemer
T. Niendorf
C. Hohl
R. W. Gunther
G. A. Krombach
Publikationsdatum
01.10.2008
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 10/2008
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-0972-3

Weitere Artikel der Ausgabe 10/2008

European Radiology 10/2008 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.