Objectives

To determine the diagnostic value of the anterior chamber depth (ACD) of a globe as seen on CT for detecting open-globe injury.

Methods

We enrolled 28 patients with unilateral open-globe injury confirmed by surgery and 28 controls with other types of orbital trauma. The diagnostic value of the difference of the ACDs between globes was evaluated by ROC analysis. The diagnostic performance of the following CT findings suggesting open-globe injury was also determined from independent analysis by two readers, i.e. change in the ACD and the globe contour, obvious volume loss of the globe, dislocated/deformed lens, intraocular foreign body/air and intraocular haemorrhage.

Results

The ACD measurements were possible only in 15 patients with open-globe injuries. A difference in the ACDs ≥0.4 mm resulted in 0.85 of the area under the ROC curve with a sensitivity of 73% and specificity of 100% (p = 0.0001). The presence of one or more of the CT findings had a sensitivity of 92%, specificity of 85% and diagnostic accuracy of 89%.

Conclusions

Change in the ACD is a helpful CT finding for detecting open-globe injury. A difference in the ACDs ≥0.4 mm is a helpful diagnostic criterion with excellent specificity.
Literatur
1.
Zurück zum Zitat Rahman I, Maino A, Devadason D, Leatherbarrow B (2006) Open globe injuries: factors predictive of poor outcome. Eye 20:1336–1341CrossRefPubMed Rahman I, Maino A, Devadason D, Leatherbarrow B (2006) Open globe injuries: factors predictive of poor outcome. Eye 20:1336–1341CrossRefPubMed
2.
Zurück zum Zitat Bord SP, Linden J (2008) Trauma to the globe and orbit. Emerg Med Clin North Am 26:97–123 vi–viiCrossRefPubMed Bord SP, Linden J (2008) Trauma to the globe and orbit. Emerg Med Clin North Am 26:97–123 vi–viiCrossRefPubMed
3.
Zurück zum Zitat Joseph DP, Pieramici DJ, Beauchamp NJ Jr (2000) Computed tomography in the diagnosis and prognosis of open-globe injuries. Ophthalmology 107:1899–1906CrossRefPubMed Joseph DP, Pieramici DJ, Beauchamp NJ Jr (2000) Computed tomography in the diagnosis and prognosis of open-globe injuries. Ophthalmology 107:1899–1906CrossRefPubMed
4.
Zurück zum Zitat Weissman JL, Beatty RL, Hirsch WL, Curtin HD (1995) Enlarged anterior chamber: CT finding of a ruptured globe. AJNR Am J Neuroradiol 16:936–938PubMed Weissman JL, Beatty RL, Hirsch WL, Curtin HD (1995) Enlarged anterior chamber: CT finding of a ruptured globe. AJNR Am J Neuroradiol 16:936–938PubMed
6.
Zurück zum Zitat Sevel D, Krausz H, Ponder T, Centeno R (1983) Value of computed tomography for the diagnosis of a ruptured eye. J Comput Assist Tomogr 7:870–875CrossRefPubMed Sevel D, Krausz H, Ponder T, Centeno R (1983) Value of computed tomography for the diagnosis of a ruptured eye. J Comput Assist Tomogr 7:870–875CrossRefPubMed
7.
Zurück zum Zitat Arey ML, Mootha VV, Whittemore AR, Chason DP, Blomquist PH (2007) Computed tomography in the diagnosis of occult open-globe injuries. Ophthalmology 114:1448–1452CrossRefPubMed Arey ML, Mootha VV, Whittemore AR, Chason DP, Blomquist PH (2007) Computed tomography in the diagnosis of occult open-globe injuries. Ophthalmology 114:1448–1452CrossRefPubMed
8.
Zurück zum Zitat Xu L, Cao WF, Wang YX, Chen CX, Jonas JB (2008) Anterior chamber depth and chamber angle and their associations with ocular and general parameters: the Beijing Eye Study. Am J Ophthalmol 145:929–936CrossRefPubMed Xu L, Cao WF, Wang YX, Chen CX, Jonas JB (2008) Anterior chamber depth and chamber angle and their associations with ocular and general parameters: the Beijing Eye Study. Am J Ophthalmol 145:929–936CrossRefPubMed
9.
Zurück zum Zitat Yi JH, Hong S, Seong GJ, Kang SY, Ma KT, Kim CY (2008) Anterior chamber measurements by pentacam and AS-OCT in eyes with normal open angles. Korean J Ophthalmol 22:242–245CrossRefPubMed Yi JH, Hong S, Seong GJ, Kang SY, Ma KT, Kim CY (2008) Anterior chamber measurements by pentacam and AS-OCT in eyes with normal open angles. Korean J Ophthalmol 22:242–245CrossRefPubMed
10.
Zurück zum Zitat Mader TH, Werner RP, Chamberlain DG (2008) Corneal perforation and delayed anterior chamber collapse from a devil’s club thorn. Cornea 27:961–962CrossRefPubMed Mader TH, Werner RP, Chamberlain DG (2008) Corneal perforation and delayed anterior chamber collapse from a devil’s club thorn. Cornea 27:961–962CrossRefPubMed
Metadaten
Titel
Diagnostic value of the anterior chamber depth of a globe on CT for detecting open-globe injury
verfasst von
Seong Yun Kim
Jeong Hyun Lee
Yong Jae Lee
Byung Se Choi
Jin Woo Choi
Hyun Sin In
Sun Mi Kim
Jung Hwan Baek
Publikationsdatum
01.05.2010
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 5/2010
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-009-1653-6

Weitere Artikel der Ausgabe 5/2010

European Radiology 5/2010 Zur Ausgabe

Mammakarzinom: Brustdichte beeinflusst rezidivfreies Überleben

26.05.2024 Mammakarzinom Nachrichten

Frauen, die zum Zeitpunkt der Brustkrebsdiagnose eine hohe mammografische Brustdichte aufweisen, haben ein erhöhtes Risiko für ein baldiges Rezidiv, legen neue Daten nahe.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.