Objectives

To compare a 256-slice CT with a simulated standard CT for brain CT perfusion (CTP).

Methods

CTP was obtained in 51 patients using a 256-slice CT (128 detector rows, flying z-focus, 8-cm detector width, 80 kV, 120mAs, 20 measurements, 1 CT image/2.5 s). Signal-to-noise ratios (SNR) were compared in grey and white matter. Perfusion maps were evaluated for cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) in hypoperfused areas and corresponding contralateral regions. Two reconstructed 10-mm slices for simulation of a standard CT (SDCT) were compared with the complete data sets (large-volume CT, LVCT).

Results

Adequate image quality was achieved in 50/51 cases. SNR were significantly different in grey and white matter. A perfusion deficit was present in 27 data sets. Differences between the hypoperfusions and the control regions were significant for MTT and CBF, but not for CBV. Three lesions were missed by SDCT but detected by LVCT; 24 lesions were covered incompletely by SDCT, and 6 by LVCT. 21 lesions were detected completely by LVCT, but none by SDCT.

Conclusions

CTP imaging of the brain using an increased detector width can detect additional ischaemic lesions and cover most ischaemic lesions completely.
Literatur
1.
Zurück zum Zitat Klingebiel R, Busch M, Bohner G, Zimmer C, Hoffmann O, Masuhr F (2002) Multi-slice CT angiography in the evaluation of patients with acute cerebrovascular disease—a promising new diagnostic tool. J Neurol 249:43–49PubMedCrossRef Klingebiel R, Busch M, Bohner G, Zimmer C, Hoffmann O, Masuhr F (2002) Multi-slice CT angiography in the evaluation of patients with acute cerebrovascular disease—a promising new diagnostic tool. J Neurol 249:43–49PubMedCrossRef
2.
Zurück zum Zitat Wintermark M (2005) Brain perfusion-CT in acute stroke patients. Eur Radiol 15(Suppl 4):D28–D31PubMed Wintermark M (2005) Brain perfusion-CT in acute stroke patients. Eur Radiol 15(Suppl 4):D28–D31PubMed
3.
Zurück zum Zitat Mayer TE, Hamann GF, Baranczyk J, Rosengarten B, Klotz E, Wiesmann M, Missler U, Schulte-Altedorneburg G, Brueckmann HJ (2000) Dynamic CT perfusion imaging of acute stroke. AJNR Am J Neuroradiol 21:1441–1449PubMed Mayer TE, Hamann GF, Baranczyk J, Rosengarten B, Klotz E, Wiesmann M, Missler U, Schulte-Altedorneburg G, Brueckmann HJ (2000) Dynamic CT perfusion imaging of acute stroke. AJNR Am J Neuroradiol 21:1441–1449PubMed
4.
Zurück zum Zitat Lövblad KO, Baird AE (2010) Computed tomography in acute ischemic stroke. Neuroradiology 52:175–187PubMedCrossRef Lövblad KO, Baird AE (2010) Computed tomography in acute ischemic stroke. Neuroradiology 52:175–187PubMedCrossRef
5.
Zurück zum Zitat Silvernnoinen HM, Hamberg LM, Lindberg PJ et al (2008) CT Perfusion identifies increased salvage of tissue in patients receiving intravenous recombinant tissue plasminogen activator within 3 hours of stroke onset. AJNR Am J Neuroradiol 29:1118–1123CrossRef Silvernnoinen HM, Hamberg LM, Lindberg PJ et al (2008) CT Perfusion identifies increased salvage of tissue in patients receiving intravenous recombinant tissue plasminogen activator within 3 hours of stroke onset. AJNR Am J Neuroradiol 29:1118–1123CrossRef
6.
Zurück zum Zitat Konstas AA, Goldmakher GV, Lee TY, Lev MH (2009) Theoretic basis and technical implementations of CT perfusion in acute ischemic stroke, part 2: technical implementations. AJNR Am J Neuroradiol 30:885–892PubMedCrossRef Konstas AA, Goldmakher GV, Lee TY, Lev MH (2009) Theoretic basis and technical implementations of CT perfusion in acute ischemic stroke, part 2: technical implementations. AJNR Am J Neuroradiol 30:885–892PubMedCrossRef
7.
Zurück zum Zitat Soares BP, Dankbaar JW, Bredno J, Cheng S, Bhogal S, Dillon WP, Wintermark M (2009) Automated versus manual post-processing of perfusion-CT data in patients with acute cerebral ischemia: influence on interobserver variability. Neuroradiology 51:445–451PubMedCrossRef Soares BP, Dankbaar JW, Bredno J, Cheng S, Bhogal S, Dillon WP, Wintermark M (2009) Automated versus manual post-processing of perfusion-CT data in patients with acute cerebral ischemia: influence on interobserver variability. Neuroradiology 51:445–451PubMedCrossRef
8.
Zurück zum Zitat Murayama K, Katada K, Nakane M, Toyama H, Anno H, Hayakawa M, Ruiz DS, Murphy KJ (2009) Whole-brain perfusion CT performed with a prototype 256-detector row CT system: initial experience. Radiology 250:202–211PubMedCrossRef Murayama K, Katada K, Nakane M, Toyama H, Anno H, Hayakawa M, Ruiz DS, Murphy KJ (2009) Whole-brain perfusion CT performed with a prototype 256-detector row CT system: initial experience. Radiology 250:202–211PubMedCrossRef
9.
Zurück zum Zitat Siebert E, Bohner G, Dewey M, Masuhr F, Hoffmann KT, Mews J, Engelken F, Bauknecht HC, Diekmann S, Klingebiel R (2009) 320-slice CT neuroimaging: initial clinical experience and image quality evaluation. Br J Radiol 82:561–570PubMedCrossRef Siebert E, Bohner G, Dewey M, Masuhr F, Hoffmann KT, Mews J, Engelken F, Bauknecht HC, Diekmann S, Klingebiel R (2009) 320-slice CT neuroimaging: initial clinical experience and image quality evaluation. Br J Radiol 82:561–570PubMedCrossRef
10.
Zurück zum Zitat Mori S, Obata T, Nakajima N, Ichihara N, Endo M (2005) Volumetric perfusion CT using prototype 256-detector row CT scanner: preliminary study with healthy porcine model. AJNR Am J Neuroradiol 26:2536–2541PubMed Mori S, Obata T, Nakajima N, Ichihara N, Endo M (2005) Volumetric perfusion CT using prototype 256-detector row CT scanner: preliminary study with healthy porcine model. AJNR Am J Neuroradiol 26:2536–2541PubMed
11.
Zurück zum Zitat Page M, Nandurkar D, Crossett MP, Stuckey SL, Lau KP, Kenning N, Troupis JM (2010) Comparison of 4 cm Z-axis and 16 cm Z-axis multidetector CT perfusion. Eur Radiol 20:1508–1514PubMedCrossRef Page M, Nandurkar D, Crossett MP, Stuckey SL, Lau KP, Kenning N, Troupis JM (2010) Comparison of 4 cm Z-axis and 16 cm Z-axis multidetector CT perfusion. Eur Radiol 20:1508–1514PubMedCrossRef
12.
Zurück zum Zitat Mullins ME, Lev MH, Bove P, O’Reilly CE, Saini S, Rhea JT et al (2004) Comparison of image quality between conventional and low-dose nonenhanced head CT. AJNR Am J Neuroradiol 25:533–8.22PubMed Mullins ME, Lev MH, Bove P, O’Reilly CE, Saini S, Rhea JT et al (2004) Comparison of image quality between conventional and low-dose nonenhanced head CT. AJNR Am J Neuroradiol 25:533–8.22PubMed
13.
Zurück zum Zitat Wintermark M, Maeder P, Thiran JP et al (2001) Quantitative assessment of regional cerebral blood flows by perfusion CT studies at low injection rates: a critical review of the underlying theoretical models. Eur Radiol 11:1220–1230PubMedCrossRef Wintermark M, Maeder P, Thiran JP et al (2001) Quantitative assessment of regional cerebral blood flows by perfusion CT studies at low injection rates: a critical review of the underlying theoretical models. Eur Radiol 11:1220–1230PubMedCrossRef
14.
Zurück zum Zitat Axel L (1983) Tissue mean transit time from dynamic computed tomography by a simple deconvolution technique. Invest Radiol 18:94–99PubMedCrossRef Axel L (1983) Tissue mean transit time from dynamic computed tomography by a simple deconvolution technique. Invest Radiol 18:94–99PubMedCrossRef
15.
Zurück zum Zitat Axel L (1980) Cerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis. Radiology 137:679–686PubMed Axel L (1980) Cerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis. Radiology 137:679–686PubMed
16.
Zurück zum Zitat Meier P, Zierler KL (1954) On the theory of the indicator-dilution method for measurement of cerebral blood flow and volume. J Appl Physiol 6:731–744PubMed Meier P, Zierler KL (1954) On the theory of the indicator-dilution method for measurement of cerebral blood flow and volume. J Appl Physiol 6:731–744PubMed
17.
Zurück zum Zitat Lee IH, You JH, Lee JY, Whang K, Kim MS, Kim YJ, Lee MS (2010) Brain Research Group. Accuracy of the detection of infratentorial stroke lesions using perfusion CT: an experimenter-blinded study. Neuroradiology 52:1095–1100PubMedCrossRef Lee IH, You JH, Lee JY, Whang K, Kim MS, Kim YJ, Lee MS (2010) Brain Research Group. Accuracy of the detection of infratentorial stroke lesions using perfusion CT: an experimenter-blinded study. Neuroradiology 52:1095–1100PubMedCrossRef
18.
Zurück zum Zitat Wintermark M, Fischbein NJ, Smith WS et al (2005) Accuracy of dynamic perfusion CT with deconvolution in detecting acute hemispheric stroke. AJNR Am J Neuroradiol 26:104–112PubMed Wintermark M, Fischbein NJ, Smith WS et al (2005) Accuracy of dynamic perfusion CT with deconvolution in detecting acute hemispheric stroke. AJNR Am J Neuroradiol 26:104–112PubMed
19.
Zurück zum Zitat Eastwood JD, Lev MH, Wintermark M et al (2003) Correlation of early dynamic CT perfusion imaging with whole-brain MR diffusion and perfusion imaging in acute hemispheric stroke. AJNR Am J Neuroradiol 24:1869–1875PubMed Eastwood JD, Lev MH, Wintermark M et al (2003) Correlation of early dynamic CT perfusion imaging with whole-brain MR diffusion and perfusion imaging in acute hemispheric stroke. AJNR Am J Neuroradiol 24:1869–1875PubMed
20.
Zurück zum Zitat Roberts HC, Roberts TP, Smith WS, Lee TJ, Fischbein NJ, Dillon WP (2001) Multisection dynamic CT perfusion for acute cerebral ischemia: the “toggling-table” technique. AJNR Am J Neuroradiol 22:1077–1080PubMed Roberts HC, Roberts TP, Smith WS, Lee TJ, Fischbein NJ, Dillon WP (2001) Multisection dynamic CT perfusion for acute cerebral ischemia: the “toggling-table” technique. AJNR Am J Neuroradiol 22:1077–1080PubMed
21.
Zurück zum Zitat Furtado AD, Lau BC, Vittinghoff E, Dillon WP, Smith WS, Rigby T, Boussel L, Wintermark M (2010) Optimal brain perfusion CT coverage in patients with acute middle cerebral artery stroke. AJNR Am J Neuroradiol 31:691–695PubMedCrossRef Furtado AD, Lau BC, Vittinghoff E, Dillon WP, Smith WS, Rigby T, Boussel L, Wintermark M (2010) Optimal brain perfusion CT coverage in patients with acute middle cerebral artery stroke. AJNR Am J Neuroradiol 31:691–695PubMedCrossRef
22.
Zurück zum Zitat Diekmann S, Siebert E, Juran R, Roll M, Deeg W, Bauknecht HC, Diekmann F, Klingebiel R, Bohner G (2010) Dose exposure of patients undergoing comprehensive stroke imaging by multidetector-row CT: comparison of 320-detector row and 64-detector row CT scanners. AJNR Am J Neuroradiol 31:1003–1009PubMedCrossRef Diekmann S, Siebert E, Juran R, Roll M, Deeg W, Bauknecht HC, Diekmann F, Klingebiel R, Bohner G (2010) Dose exposure of patients undergoing comprehensive stroke imaging by multidetector-row CT: comparison of 320-detector row and 64-detector row CT scanners. AJNR Am J Neuroradiol 31:1003–1009PubMedCrossRef
23.
Zurück zum Zitat Wintermark M, Reichhart M, Thiran JP, Maeder P, Chalaron M, Schnyder P, Bogousslavsky J, Meuli R (2002) Prognostic accuracy of cerebral blood flow measurement by perfusion computed tomography, at the time of emergency room admission, in acute stroke patients. Ann Neurol 51:417–432PubMedCrossRef Wintermark M, Reichhart M, Thiran JP, Maeder P, Chalaron M, Schnyder P, Bogousslavsky J, Meuli R (2002) Prognostic accuracy of cerebral blood flow measurement by perfusion computed tomography, at the time of emergency room admission, in acute stroke patients. Ann Neurol 51:417–432PubMedCrossRef
24.
Zurück zum Zitat Wintermark M, Smith WS, Ko NU, Quist M, Schnyder P, Dillon WP (2004) Dynamic perfusion CT: optimizing the temporal resolution and contrast volume for calculation of perfusion CT parameters in stroke patients. AJNR Am J Neuroradiol 25:720–729PubMed Wintermark M, Smith WS, Ko NU, Quist M, Schnyder P, Dillon WP (2004) Dynamic perfusion CT: optimizing the temporal resolution and contrast volume for calculation of perfusion CT parameters in stroke patients. AJNR Am J Neuroradiol 25:720–729PubMed
25.
Zurück zum Zitat Wiesmann M, Berg S, Bohner G, Klingebiel R, Schöpf V, Stoeckelhuber BM, Yousry I, Linn J, Missler U (2008) Dose reduction in dynamic perfusion CT of the brain: effects of the scan frequency on measurements of cerebral blood flow, cerebral blood volume, and mean transit time. Eur Radiol 18:2967–2974PubMedCrossRef Wiesmann M, Berg S, Bohner G, Klingebiel R, Schöpf V, Stoeckelhuber BM, Yousry I, Linn J, Missler U (2008) Dose reduction in dynamic perfusion CT of the brain: effects of the scan frequency on measurements of cerebral blood flow, cerebral blood volume, and mean transit time. Eur Radiol 18:2967–2974PubMedCrossRef
Metadaten
Titel
Brain perfusion CT for acute stroke using a 256-slice CT: improvement of diagnostic information by large volume coverage
verfasst von
F. Dorn
D. Muenzel
R. Meier
H. Poppert
E. J. Rummeny
A. Huber
Publikationsdatum
01.09.2011
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 9/2011
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-011-2128-0

Weitere Artikel der Ausgabe 9/2011

European Radiology 9/2011 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.