Dose reduction in dynamic perfusion CT of the brain: effects of the scan frequency on measurements of cerebral blood flow, cerebral blood volume, and mean transit time

verfasst von: Martin Wiesmann, Scott Berg, G. Bohner, R. Klingebiel, V. Schöpf, B. M. Stoeckelhuber, I. Yousry, J. Linn, U. Missler

Erschienen in: European Radiology | Ausgabe 12/2008

Einloggen, um Zugang zu erhalten

Abstract

The influence of the frequency of computed tomography (CT) image acquistion on the diagnostic quality of dynamic perfusion CT (PCT) studies of the brain was investigated. Eight patients with clinically suspected acute ischemia of one hemisphere underwent PCT, performed on average 3.4 h after the onset of symptoms. Sixty consecutive images per slice were obtained with individual CT images obtained at a temporal resolution of two images per second. Eight additional data sets were reconstructed with temporal resolutions ranging from one image per second to one image per 5 s. Cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) measurements were performed in identical regions of interest. Two neuroradiologists evaluated the PCT images visually to identify areas of abnormal perfusion. Perfusion images created up to a temporal resolution of one image per 3 s were rated to be diagnostically equal to the original data. Even at one image per 4 s, all areas of infarction were identified. Quantitative differences of CBF, CBV and MTT measurements were ≤10% up to one image per 3 s. For PCT of the brain, temporal resolution can be reduced to one image per 3 s without significant compromise in image quality. This significantly reduces the radiation dose of the patient.
Literatur
1.
Zurück zum Zitat Latchaw RE, Yonas H, Hunter GJ, Yuh WT, Ueda T, Sorensen AG, Sunshine JL, Biller J, Wechsler L, Higashida R, Hademenos G, Council on Cardiovascular Radiology of the American Heart Association (2003) Guidelines and recommendations for perfusion imaging in cerebral ischemia: a scientific statement for healthcare professionals by the writing group on perfusion imaging, from the council on cardiovascular radiology of the American Heart Association. Stroke 34:1084–1104PubMedCrossRef Latchaw RE, Yonas H, Hunter GJ, Yuh WT, Ueda T, Sorensen AG, Sunshine JL, Biller J, Wechsler L, Higashida R, Hademenos G, Council on Cardiovascular Radiology of the American Heart Association (2003) Guidelines and recommendations for perfusion imaging in cerebral ischemia: a scientific statement for healthcare professionals by the writing group on perfusion imaging, from the council on cardiovascular radiology of the American Heart Association. Stroke 34:1084–1104PubMedCrossRef
2.
Zurück zum Zitat Mayer TE, Hamann GF, Baranczyk J, Rosengarten B, Klotz E, Wiesmann M, Missler U, Schulte-Altedorneburg G, Brueckmann HJ (2000) Dynamic CT perfusion imaging of acute stroke. AJNR Am J Neuroradiol 21:1441–1449PubMed Mayer TE, Hamann GF, Baranczyk J, Rosengarten B, Klotz E, Wiesmann M, Missler U, Schulte-Altedorneburg G, Brueckmann HJ (2000) Dynamic CT perfusion imaging of acute stroke. AJNR Am J Neuroradiol 21:1441–1449PubMed
3.
Zurück zum Zitat Wiesmann M, Bohner G, Klingebiel R (2004) Cerebral perfusion imaging using multislice computed tomography. Clin Neuroradiol 14:92–107CrossRef Wiesmann M, Bohner G, Klingebiel R (2004) Cerebral perfusion imaging using multislice computed tomography. Clin Neuroradiol 14:92–107CrossRef
4.
Zurück zum Zitat Wiesmann M, Meyer K, Albers T, Seidel G (2004) Parametric perfusion imaging with contrast-enhanced ultrasound in acute ischemic stroke. Stroke 35:508–513PubMedCrossRef Wiesmann M, Meyer K, Albers T, Seidel G (2004) Parametric perfusion imaging with contrast-enhanced ultrasound in acute ischemic stroke. Stroke 35:508–513PubMedCrossRef
5.
Zurück zum Zitat Wintermark M, Bogousslavsky J (2003) Imaging of acute ischemic brain injury: the return of computed tomography. Curr Opin Neurol 16:59–63PubMedCrossRef Wintermark M, Bogousslavsky J (2003) Imaging of acute ischemic brain injury: the return of computed tomography. Curr Opin Neurol 16:59–63PubMedCrossRef
6.
Zurück zum Zitat Wintermark M, Maeder P, Verdun FR, Thiran JP, Valley JF, Schnyder P, Meuli R (2000) Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow. AJNR Am J Neuroradiol 21:1881–1884PubMed Wintermark M, Maeder P, Verdun FR, Thiran JP, Valley JF, Schnyder P, Meuli R (2000) Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow. AJNR Am J Neuroradiol 21:1881–1884PubMed
7.
Zurück zum Zitat Fleischmann D, Rubin GD, Bankier AA, Hittmair K (2000) Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography. Radiology 214:363–371PubMed Fleischmann D, Rubin GD, Bankier AA, Hittmair K (2000) Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography. Radiology 214:363–371PubMed
8.
Zurück zum Zitat König M (2003) Brain perfusion CT in acute stroke: current status. Eur J Radiol 45:S11–S22PubMedCrossRef König M (2003) Brain perfusion CT in acute stroke: current status. Eur J Radiol 45:S11–S22PubMedCrossRef
9.
Zurück zum Zitat Wintermark M, Smith WS, Ko NU, Quist M, Schnyder P, Dillon WP (2004) Dynamic perfusion CT: Optimizing the temporal resolution and contrast volume for calculation of perfusion CT parameters in stroke patients. AJNR Am J Neuroradiol 25:720–729PubMed Wintermark M, Smith WS, Ko NU, Quist M, Schnyder P, Dillon WP (2004) Dynamic perfusion CT: Optimizing the temporal resolution and contrast volume for calculation of perfusion CT parameters in stroke patients. AJNR Am J Neuroradiol 25:720–729PubMed
10.
Zurück zum Zitat Kämena A, Streitparth F, Grieser C, Lehmkuhl L, Jamil B, Wojtal K, Ricke J, Pech M (2007) Dynamic perfusion CT: Optimizing the temporal resolution for the calculation of perfusion CT parameters in stroke patients. Eur J Radiol 64:111–118PubMedCrossRef Kämena A, Streitparth F, Grieser C, Lehmkuhl L, Jamil B, Wojtal K, Ricke J, Pech M (2007) Dynamic perfusion CT: Optimizing the temporal resolution for the calculation of perfusion CT parameters in stroke patients. Eur J Radiol 64:111–118PubMedCrossRef
11.
Zurück zum Zitat Nambu K, Takehara R, Terada T (1996) A method of regional cerebral blood perfusion measurement using dynamic CT with an iodinated contrast medium. Acta Neurol Scand Suppl 166:28–31PubMedCrossRef Nambu K, Takehara R, Terada T (1996) A method of regional cerebral blood perfusion measurement using dynamic CT with an iodinated contrast medium. Acta Neurol Scand Suppl 166:28–31PubMedCrossRef
12.
Zurück zum Zitat Wintermark M, Reichhart M, Thiran JP, Maeder P, Chalaron M, Schnyder P, Bogousslavsky J, Meuli R (2002) Prognostic accuracy of cerebral blood flow measurement by perfusion computed tomography, at the time of emergency room admission, in acute stroke patients. Ann Neurol 51:417–432PubMedCrossRef Wintermark M, Reichhart M, Thiran JP, Maeder P, Chalaron M, Schnyder P, Bogousslavsky J, Meuli R (2002) Prognostic accuracy of cerebral blood flow measurement by perfusion computed tomography, at the time of emergency room admission, in acute stroke patients. Ann Neurol 51:417–432PubMedCrossRef
13.
Zurück zum Zitat Wintermark M, Maeder P, Verdun FR, Thiran JP, Valley JF, Schnyder P, Meuli R (2000) Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow. AJNR Am J Neuroradiol 21:1881–1884PubMed Wintermark M, Maeder P, Verdun FR, Thiran JP, Valley JF, Schnyder P, Meuli R (2000) Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow. AJNR Am J Neuroradiol 21:1881–1884PubMed
14.
Zurück zum Zitat Imanishi Y, Fukui A, Niimi H, Itoh D, Nozaki K, Nakaji S, Ishizuka K, Tabata H, Furuya Y, Uzura M, Takahama H, Hashizume S, Arima S, Nakajima Y (2005) Radiation-induced temporary hair loss as a radiation damage only occurring in patients who had the combination of MDCT and DSA. Eur Radiol 15:41–46PubMedCrossRef Imanishi Y, Fukui A, Niimi H, Itoh D, Nozaki K, Nakaji S, Ishizuka K, Tabata H, Furuya Y, Uzura M, Takahama H, Hashizume S, Arima S, Nakajima Y (2005) Radiation-induced temporary hair loss as a radiation damage only occurring in patients who had the combination of MDCT and DSA. Eur Radiol 15:41–46PubMedCrossRef
Metadaten
Titel
Dose reduction in dynamic perfusion CT of the brain: effects of the scan frequency on measurements of cerebral blood flow, cerebral blood volume, and mean transit time
verfasst von
Martin Wiesmann
Scott Berg
G. Bohner
R. Klingebiel
V. Schöpf
B. M. Stoeckelhuber
I. Yousry
J. Linn
U. Missler
Publikationsdatum
01.12.2008
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 12/2008
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-1083-x

Weitere Artikel der Ausgabe 12/2008

European Radiology 12/2008 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.