Abstract

Objectives

3D turbo field echo with diffusion-sensitised driven-equilibrium preparation (DSDE-TFE) is a novel non-echo planar technique for diffusion-weighted (DW) imaging. The purpose of this study was to differentiate intraorbital lymphoma from immunoglobulin G4-related disease (IgG4-RD) using the apparent diffusion coefficient (ADC) derived from DSDE-TFE.

Methods

Fifteen patients with lymphomas and 8 with IgG4-RDs underwent imaging. ADC and signal intensities compared with normal grey matter on T1-weighted images, fat-suppressed T2-weighted images and fat-suppressed postcontrast T1-weighted images were measured. Statistical analyses were performed using the Mann–Whitney U test and receiver operating characteristic (ROC) analysis.

Results

Intraorbital lesions were clearly visualised on DSDE-TFE without obvious geometrical distortion. The ADC of lymphoma (1.25 ± 0.50 × 10−3 mm2/s; mean ± standard deviation) was significantly lower than that of IgG4-RD (1.67 ± 0.84 × 10−3 mm2/s; P < 0.05). Conventional sequences could not separate lymphoma from IgG4-RD (0.93 ± 0.18 vs. 0.94 ± 0.21 on T1-weighted images, 0.92 ± 0.17 vs. 0.95 ± 0.14 on T2-weighted images and 2.03 ± 0.35 vs. 2.30 ± 0.58 on postcontrast T1-weighted images, for lymphoma and IgG4-RD, respectively; P > 0.05). ROC analysis showed the best diagnostic performance with ADC.

Conclusion

The apparent diffusion coefficient derived from diffusion-sensitised driven-equilibrium preparation techniques may help to differentiate lymphoma from immunoglobulin G4-related disease.

Key Points

Distinguishing between orbital lymphoma and immunoglobulin G4-related disease can be difficult
Intraorbital lesions were clearly visualised on diffusion-sensitised driven-equilibrium preparation magnetic resonance techniques.
Variations in field homogeneity do not affect DSDE-TFE techniques all that much.
ADCs derived from DSDE-TFE may help differentiate lymphoma from IgG4-RD.
Literatur
1.
Zurück zum Zitat Le Bihan D, Breton E, Lallemand D, Grenier P, Cabanis E, Laval-Jeantet M (1986) MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. Radiology 161:401–407PubMed Le Bihan D, Breton E, Lallemand D, Grenier P, Cabanis E, Laval-Jeantet M (1986) MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. Radiology 161:401–407PubMed
2.
Zurück zum Zitat Provenzale JM, Sorensen AG (1999) Diffusion-weighted MR imaging in acute stroke: theoretic considerations and clinical applications. AJR Am J Roentgenol 173:1459–1467PubMedCrossRef Provenzale JM, Sorensen AG (1999) Diffusion-weighted MR imaging in acute stroke: theoretic considerations and clinical applications. AJR Am J Roentgenol 173:1459–1467PubMedCrossRef
3.
Zurück zum Zitat Guo AC, Cummings TJ, Dash RC, Provenzale JM (2002) Lymphomas and high-grade astrocytomas: comparison of water diffusibility and histologic characteristics. Radiology 224:177–183PubMedCrossRef Guo AC, Cummings TJ, Dash RC, Provenzale JM (2002) Lymphomas and high-grade astrocytomas: comparison of water diffusibility and histologic characteristics. Radiology 224:177–183PubMedCrossRef
4.
Zurück zum Zitat Yamasaki F, Kurisu K, Satoh K et al (2005) Apparent diffusion coefficient of human brain tumors at MR imaging. Radiology 235:985–991PubMedCrossRef Yamasaki F, Kurisu K, Satoh K et al (2005) Apparent diffusion coefficient of human brain tumors at MR imaging. Radiology 235:985–991PubMedCrossRef
5.
Zurück zum Zitat Yamashita K, Yoshiura T, Hiwatashi A et al (2013) Differentiating primary CNS lymphoma from glioblastoma multiforme: assessment using arterial spin labeling, diffusion-weighted imaging, and (18)F-fluorodeoxyglucose positron emission tomography. Neuroradiology 55:135–143PubMedCrossRef Yamashita K, Yoshiura T, Hiwatashi A et al (2013) Differentiating primary CNS lymphoma from glioblastoma multiforme: assessment using arterial spin labeling, diffusion-weighted imaging, and (18)F-fluorodeoxyglucose positron emission tomography. Neuroradiology 55:135–143PubMedCrossRef
6.
Zurück zum Zitat Matsushima N, Maeda M, Umino M, Suzawa N, Yamada T, Takeda K (2012) Relation between FDG uptake and apparent diffusion coefficients in glioma and malignant lymphoma. Ann Nucl Med 26:262–271PubMedCrossRef Matsushima N, Maeda M, Umino M, Suzawa N, Yamada T, Takeda K (2012) Relation between FDG uptake and apparent diffusion coefficients in glioma and malignant lymphoma. Ann Nucl Med 26:262–271PubMedCrossRef
7.
Zurück zum Zitat Choi JW, Kim SY, Moon KC, Cho JY, Kim SH (2012) Immunoglobulin G4-related sclerosing disease involving the urethra: case report. Korean J Radiol 13:803–807PubMedCentralPubMedCrossRef Choi JW, Kim SY, Moon KC, Cho JY, Kim SH (2012) Immunoglobulin G4-related sclerosing disease involving the urethra: case report. Korean J Radiol 13:803–807PubMedCentralPubMedCrossRef
8.
Zurück zum Zitat Taniguchi T, Kobayashi H, Nishikawa K et al (2009) Diffusion-weighted magnetic resonance imaging in autoimmune pancreatitis. Jpn J Radiol 27:138–142PubMedCrossRef Taniguchi T, Kobayashi H, Nishikawa K et al (2009) Diffusion-weighted magnetic resonance imaging in autoimmune pancreatitis. Jpn J Radiol 27:138–142PubMedCrossRef
9.
Zurück zum Zitat Razek AA, Elkhamary S, Mousa A (2011) Differentiation between benign and malignant orbital tumors at 3-T diffusion MR-imaging. Neuroradiology 53:517–522PubMedCrossRef Razek AA, Elkhamary S, Mousa A (2011) Differentiation between benign and malignant orbital tumors at 3-T diffusion MR-imaging. Neuroradiology 53:517–522PubMedCrossRef
10.
Zurück zum Zitat de Graaf P, Pouwels PJ, Rodjan F et al (2012) Single-shot turbo spin-echo diffusion-weighted imaging for retinoblastoma: initial experience. AJNR Am J Neuroradiol 33:110–118PubMedCrossRef de Graaf P, Pouwels PJ, Rodjan F et al (2012) Single-shot turbo spin-echo diffusion-weighted imaging for retinoblastoma: initial experience. AJNR Am J Neuroradiol 33:110–118PubMedCrossRef
11.
Zurück zum Zitat Hiwatashi A, Yoshiura T, Togao O et al (2013) Evaluation of diffusivity in anterior lobe of the pituitary gland: 3D turbo field echo with diffusion-sensitized driven-equilibrium preparation. AJNR Am J Neuroradiol. doi:10.3174/ajnr.A3620 PubMed Hiwatashi A, Yoshiura T, Togao O et al (2013) Evaluation of diffusivity in anterior lobe of the pituitary gland: 3D turbo field echo with diffusion-sensitized driven-equilibrium preparation. AJNR Am J Neuroradiol. doi:10.​3174/​ajnr.​A3620 PubMed
12.
Zurück zum Zitat Politi LS, Forghani R, Godi C et al (2010) Ocular adnexal lymphoma: diffusion-weighted MR imaging for differential diagnosis and therapeutic monitoring. Radiology 256:565–574PubMedCrossRef Politi LS, Forghani R, Godi C et al (2010) Ocular adnexal lymphoma: diffusion-weighted MR imaging for differential diagnosis and therapeutic monitoring. Radiology 256:565–574PubMedCrossRef
13.
Zurück zum Zitat Sepahdari AR, Aakalu VK, Setabutr P, Shiehmorteza M, Naheedy JH, Mafee MF (2010) Indeterminate orbital masses: restricted diffusion at MR imaging with echo-planar diffusion-weighted imaging predicts malignancy. Radiology 256:554–564PubMedCrossRef Sepahdari AR, Aakalu VK, Setabutr P, Shiehmorteza M, Naheedy JH, Mafee MF (2010) Indeterminate orbital masses: restricted diffusion at MR imaging with echo-planar diffusion-weighted imaging predicts malignancy. Radiology 256:554–564PubMedCrossRef
14.
Zurück zum Zitat Obara M, Takahara T, Honda M, Kwee T, Imai Y, Van Gauteren M (2011) Diffusion weighted MR nerve sheath imaging (DW-NSI) using diffusion-sensitized driven-equilibrium (DSDE). Proc Int Soc Magn Reson Med 19:4023 Obara M, Takahara T, Honda M, Kwee T, Imai Y, Van Gauteren M (2011) Diffusion weighted MR nerve sheath imaging (DW-NSI) using diffusion-sensitized driven-equilibrium (DSDE). Proc Int Soc Magn Reson Med 19:4023
15.
Zurück zum Zitat Nezafat R, Stuber M, Ouwerkerk R, Gharib AM, Desai MY, Pettigrew RI (2006) B1-insensitive T2 preparation for improved coronary magnetic resonance angiography at 3 T. Magn Reson Med 55:858–864PubMedCrossRef Nezafat R, Stuber M, Ouwerkerk R, Gharib AM, Desai MY, Pettigrew RI (2006) B1-insensitive T2 preparation for improved coronary magnetic resonance angiography at 3 T. Magn Reson Med 55:858–864PubMedCrossRef
16.
Zurück zum Zitat Masaki Y, Sugai S, Umehara H (2010) IgG4-related diseases including Mikulicz's disease and sclerosing pancreatitis: diagnostic insights. J Rheumatol 37:1380–1385PubMedCrossRef Masaki Y, Sugai S, Umehara H (2010) IgG4-related diseases including Mikulicz's disease and sclerosing pancreatitis: diagnostic insights. J Rheumatol 37:1380–1385PubMedCrossRef
17.
Zurück zum Zitat Umehara H, Okazaki K, Masaki Y et al (2012) Comprehensive diagnostic criteria for IgG4-related disease (IgG4-RD), 2011. Mod Rheumatol 22:21–30PubMedCrossRef Umehara H, Okazaki K, Masaki Y et al (2012) Comprehensive diagnostic criteria for IgG4-related disease (IgG4-RD), 2011. Mod Rheumatol 22:21–30PubMedCrossRef
18.
Zurück zum Zitat Deshpande V (2012) The pathology of IgG4-related disease: critical issues and challenges. Semin Diagn Pathol 29:191–196PubMedCrossRef Deshpande V (2012) The pathology of IgG4-related disease: critical issues and challenges. Semin Diagn Pathol 29:191–196PubMedCrossRef
19.
20.
Zurück zum Zitat Koktzoglou I, Li D (2007) Diffusion-prepared segmented steady-state free precession: application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls. J Cardiovasc Magn Reson 9:33–42PubMedCrossRef Koktzoglou I, Li D (2007) Diffusion-prepared segmented steady-state free precession: application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls. J Cardiovasc Magn Reson 9:33–42PubMedCrossRef
21.
Zurück zum Zitat Wang J, Yarnykh VL, Hatsukami T, Chu B, Balu N, Yuan C (2007) Improved suppression of plaque-mimicking artifacts in black-blood carotid atherosclerosis imaging using a multislice motion-sensitized driven-equilibrium (MSDE) turbo spin-echo (TSE) sequence. Magn Reson Med 58:973–981PubMedCrossRef Wang J, Yarnykh VL, Hatsukami T, Chu B, Balu N, Yuan C (2007) Improved suppression of plaque-mimicking artifacts in black-blood carotid atherosclerosis imaging using a multislice motion-sensitized driven-equilibrium (MSDE) turbo spin-echo (TSE) sequence. Magn Reson Med 58:973–981PubMedCrossRef
22.
Zurück zum Zitat Nagao E, Yoshiura T, Hiwatashi A et al (2011) 3D turbo spin-echo sequence with motion-sensitized driven-equilibrium preparation for detection of brain metastases on 3T MR imaging. AJNR Am J Neuroradiol 32:664–670PubMedCrossRef Nagao E, Yoshiura T, Hiwatashi A et al (2011) 3D turbo spin-echo sequence with motion-sensitized driven-equilibrium preparation for detection of brain metastases on 3T MR imaging. AJNR Am J Neuroradiol 32:664–670PubMedCrossRef
23.
Zurück zum Zitat Coremans J, Spanoghe M, Budinsky L et al (1997) A comparison between different imaging strategies for diffusion measurements with the centric phase-encoded turboFLASH sequence. J Magn Reson 124:323–342PubMedCrossRef Coremans J, Spanoghe M, Budinsky L et al (1997) A comparison between different imaging strategies for diffusion measurements with the centric phase-encoded turboFLASH sequence. J Magn Reson 124:323–342PubMedCrossRef
24.
Zurück zum Zitat Thomas DL, Pell GS, Lythgoe MF, Gadian DG, Ordidge RJ (1998) A quantitative method for fast diffusion imaging using magnetization-prepared TurboFLASH. Magn Reson Med 39:950–960PubMedCrossRef Thomas DL, Pell GS, Lythgoe MF, Gadian DG, Ordidge RJ (1998) A quantitative method for fast diffusion imaging using magnetization-prepared TurboFLASH. Magn Reson Med 39:950–960PubMedCrossRef
Metadaten
Titel
Diffusivity of intraorbital lymphoma vs. IgG4-related DISEASE: 3D turbo field echo with diffusion-sensitised driven-equilibrium preparation technique
verfasst von
Akio Hiwatashi
Takashi Yoshiura
Osamu Togao
Koji Yamashita
Kazufumi Kikuchi
Yoko Fujita
Hiroshi Yoshikawa
Takaomi Koga
Makoto Obara
Hiroshi Honda
Publikationsdatum
01.03.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 3/2014
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-013-3058-9

Weitere Artikel der Ausgabe 3/2014

European Radiology 3/2014 Zur Ausgabe

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Wie toxische Männlichkeit der Gesundheit von Männern schadet

08.04.2024 Andrologie Nachrichten

Stark, erfolgreich, allzeit belastbar – das sind Erwartungen, die Jungen und Männer von der Gesellschaft spüren. Das kann sie „toxisch“ werden lassen – und letztlich sogar der Gesundheit schaden, mahnt Dr. Dirk Sander von der Deutschen Aidshilfe.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.