Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 5/2016

12.03.2016 | Knee Arthroplasty

Measuring long radiographs affects the positioning of femoral components in total knee arthroplasty: a randomized controlled trial

verfasst von: Justinas Stucinskas, Otto Robertsson, Aleksej Lebedev, Hans Wingstrand, Alfredas Smailys, Sarunas Tarasevicius

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 5/2016

Einloggen, um Zugang zu erhalten

Abstract

Introduction

The aim of this study was to investigate if preoperative measurements of the femoral valgus angle (FVA) affected the mechanical alignment, individual component positions and clinical outcome in total knee arthroplasty (TKA).

Methods

120 patients were randomized into two groups. In one group (control), a fixed FVA for the intramedullary femoral guide was set at 7°, whereas in the other group (measured) FVA was measured preoperatively on long hip–knee–ankle radiographs, and the angle for the distal femoral cut was set accordingly. Preoperatively and 1 year after TKA, range of motion (ROM) and Knee Society Score (KSS) were assessed. Postoperatively, the coronal alignments of the components and the mechanical alignment were measured comparing the rate of outliers which deviated more than 3° from the neutral mechanical axis.

Results

104 patients remained for the radiological analysis (52 in each group). There were no significant differences either in the mean preoperative or postoperative mechanical alignment, or femoral or tibial component alignment; also, there were no differences in the number of postoperative mechanical axis or tibial component alignment outliers. However, the number of femoral component alignment outliers was significantly higher in the control group. 97 patients were available for clinical outcome analysis. Preoperatively, the groups did not differ significantly with respect to KSS or ROM. The postoperative ROM and KSS functional subscale scores were similar between the groups. However, there was slightly but significantly better postoperative KSS objective subscale score in the measured group.

Conclusions

Preoperative FVA measurement and following femoral distal cut adjustments did not affect overall leg alignment postoperatively, while positioning of femoral component was improved together with minor improvements in objective KSS subscale scores.
Literatur
1.
Zurück zum Zitat Fang DM, Ritter MA, Davis KE (2009) Coronal alignment in total knee arthroplasty: just how important is it? J Arthroplast 24(6 Suppl):39–43CrossRef Fang DM, Ritter MA, Davis KE (2009) Coronal alignment in total knee arthroplasty: just how important is it? J Arthroplast 24(6 Suppl):39–43CrossRef
2.
Zurück zum Zitat Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA (2011) The effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am 93(17):1588–1596CrossRefPubMed Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA (2011) The effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am 93(17):1588–1596CrossRefPubMed
3.
Zurück zum Zitat Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE (2004) Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34CrossRefPubMed Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE (2004) Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34CrossRefPubMed
4.
Zurück zum Zitat Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79PubMed Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79PubMed
5.
Zurück zum Zitat Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73(5):709–714PubMed Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73(5):709–714PubMed
6.
Zurück zum Zitat Deakin AH, Basanagoudar PL, Nunag P, Johnston AT, Sarungi M (2012) Natural distribution of the femoral mechanical-anatomical angle in an osteoarthritic population and its relevance to total knee arthroplasty. Knee 19(2):120–123CrossRefPubMed Deakin AH, Basanagoudar PL, Nunag P, Johnston AT, Sarungi M (2012) Natural distribution of the femoral mechanical-anatomical angle in an osteoarthritic population and its relevance to total knee arthroplasty. Knee 19(2):120–123CrossRefPubMed
7.
Zurück zum Zitat Matsumoto K, Mori N, Ogawa H, Akiyama H (2015) Accuracy of a novel extramedullary femoral alignment guide system in primary total knee arthroplasty. Arch Orthop Trauma Surg 135(12):1743–1748CrossRefPubMed Matsumoto K, Mori N, Ogawa H, Akiyama H (2015) Accuracy of a novel extramedullary femoral alignment guide system in primary total knee arthroplasty. Arch Orthop Trauma Surg 135(12):1743–1748CrossRefPubMed
8.
Zurück zum Zitat Kharwadkar N, Kent RE, Sharara KH, Naique S (2006) 5 degrees to 6 degrees of distal femoral cut for uncomplicated primary total knee arthroplasty: is it safe? Knee 13(1):57–60CrossRefPubMed Kharwadkar N, Kent RE, Sharara KH, Naique S (2006) 5 degrees to 6 degrees of distal femoral cut for uncomplicated primary total knee arthroplasty: is it safe? Knee 13(1):57–60CrossRefPubMed
9.
Zurück zum Zitat Bardakos N, Cil A, Thompson B, Stocks G (2007) Mechanical axis cannot be restored in total knee arthroplasty with a fixed valgus resection angle: a radiographic study. J Arthroplast 22(6 Suppl 2):85–89CrossRef Bardakos N, Cil A, Thompson B, Stocks G (2007) Mechanical axis cannot be restored in total knee arthroplasty with a fixed valgus resection angle: a radiographic study. J Arthroplast 22(6 Suppl 2):85–89CrossRef
10.
Zurück zum Zitat McGrory JE, Trousdale RT, Pagnano MW, Nigbur M (2002) Preoperative hip to ankle radiographs in total knee arthroplasty. Clin Orthop Relat Res 404:196–202CrossRefPubMed McGrory JE, Trousdale RT, Pagnano MW, Nigbur M (2002) Preoperative hip to ankle radiographs in total knee arthroplasty. Clin Orthop Relat Res 404:196–202CrossRefPubMed
11.
Zurück zum Zitat Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the knee society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the knee society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed
12.
Zurück zum Zitat Burnett S, Hart DJ, Cooper C et al (1994) A radiographic atlas of osteoarthritis. Springer, London Burnett S, Hart DJ, Cooper C et al (1994) A radiographic atlas of osteoarthritis. Springer, London
13.
Zurück zum Zitat Jonsson K, Boegard T (2002) Radiography. In: Davies AM, Cassar-Pullicino VN (eds) Imaging of the knee: techniques and applications. Springer-Verlag, Berlin Heidelberg, pp 3–16 Jonsson K, Boegard T (2002) Radiography. In: Davies AM, Cassar-Pullicino VN (eds) Imaging of the knee: techniques and applications. Springer-Verlag, Berlin Heidelberg, pp 3–16
14.
Zurück zum Zitat Mose K (1980) Methods of measuring in Legg-Calvé-Perthes disease with special regard to the prognosis. Clin Orthop Relat Res 150:103–109PubMed Mose K (1980) Methods of measuring in Legg-Calvé-Perthes disease with special regard to the prognosis. Clin Orthop Relat Res 150:103–109PubMed
15.
Zurück zum Zitat Moreland JR, Bassett LW, Hanker GJ (1987) Radiographic analysis of the axial alignment of the lower extremity. J Bone Joint Surg Am 69(5):745–749PubMed Moreland JR, Bassett LW, Hanker GJ (1987) Radiographic analysis of the axial alignment of the lower extremity. J Bone Joint Surg Am 69(5):745–749PubMed
16.
Zurück zum Zitat Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV Jr (2012) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470(1):99–107CrossRefPubMedPubMedCentral Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV Jr (2012) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470(1):99–107CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Parratte S, Pagnano MW, Trousdale RT, Berry DJ (2010) Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am 92(12):2143–2149CrossRefPubMed Parratte S, Pagnano MW, Trousdale RT, Berry DJ (2010) Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am 92(12):2143–2149CrossRefPubMed
18.
Zurück zum Zitat Bellemans J, Colyn W, Vandenneucker H, Victor J (2012) The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res 470(1):45–53CrossRefPubMedPubMedCentral Bellemans J, Colyn W, Vandenneucker H, Victor J (2012) The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res 470(1):45–53CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Abdel MP, Oussedik S, Parratte S, Lustig S, Haddad FS (2014) Coronal alignment in total knee replacement: historical review, contemporary analysis, and future direction. Bone Joint J 96-B(7):857–862CrossRefPubMed Abdel MP, Oussedik S, Parratte S, Lustig S, Haddad FS (2014) Coronal alignment in total knee replacement: historical review, contemporary analysis, and future direction. Bone Joint J 96-B(7):857–862CrossRefPubMed
20.
Zurück zum Zitat Kim JM, Hong SH, Kim JM, Lee BS, Kim DE, Kim KA, Bin SI (2015) Femoral shaft bowing in the coronal plane has more significant effect on the coronal alignment of TKA than proximal or distal variations of femoral shape. Knee Surg Sports Traumatol Arthrosc 23(7):1936–1942CrossRefPubMed Kim JM, Hong SH, Kim JM, Lee BS, Kim DE, Kim KA, Bin SI (2015) Femoral shaft bowing in the coronal plane has more significant effect on the coronal alignment of TKA than proximal or distal variations of femoral shape. Knee Surg Sports Traumatol Arthrosc 23(7):1936–1942CrossRefPubMed
21.
Zurück zum Zitat Nagamine R, Miura H, Bravo CV, Urabe K, Matsuda S, Miyanishi K, Hirata G, Iwamoto Y (2000) Anatomic variations should be considered in total knee arthroplasty. J Orthop Sci 5(3):232–237CrossRefPubMed Nagamine R, Miura H, Bravo CV, Urabe K, Matsuda S, Miyanishi K, Hirata G, Iwamoto Y (2000) Anatomic variations should be considered in total knee arthroplasty. J Orthop Sci 5(3):232–237CrossRefPubMed
22.
Zurück zum Zitat Pfitzner T, von Roth P, Perka C, Matziolis G (2014) Intramedullary control of distal femoral resection results in precise coronal alignment in TKA. Arch Orthop Trauma Surg 134(4):459–465CrossRefPubMed Pfitzner T, von Roth P, Perka C, Matziolis G (2014) Intramedullary control of distal femoral resection results in precise coronal alignment in TKA. Arch Orthop Trauma Surg 134(4):459–465CrossRefPubMed
23.
Zurück zum Zitat Kim YH, Park JW, Kim JS, Park SD (2014) The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis. Int Orthop 38(2):379–385CrossRefPubMedPubMedCentral Kim YH, Park JW, Kim JS, Park SD (2014) The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis. Int Orthop 38(2):379–385CrossRefPubMedPubMedCentral
24.
Zurück zum Zitat Tang WM, Zhu YH, Chiu KY (2000) Axial alignment of the lower extremity in Chinese adults. J Bone Joint Surg Am 82-A(11):1603–1608PubMed Tang WM, Zhu YH, Chiu KY (2000) Axial alignment of the lower extremity in Chinese adults. J Bone Joint Surg Am 82-A(11):1603–1608PubMed
25.
Zurück zum Zitat Mullaji AB, Shetty GM, Kanna R, Vadapalli RC (2013) The influence of preoperative deformity on valgus correction angle: an analysis of 503 total knee arthroplasties. J Arthroplast 28(1):20–27CrossRef Mullaji AB, Shetty GM, Kanna R, Vadapalli RC (2013) The influence of preoperative deformity on valgus correction angle: an analysis of 503 total knee arthroplasties. J Arthroplast 28(1):20–27CrossRef
26.
Zurück zum Zitat Choong PF, Dowsey MM, Stoney JD (2009) Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty. J Arthroplast 24:560–569CrossRef Choong PF, Dowsey MM, Stoney JD (2009) Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty. J Arthroplast 24:560–569CrossRef
27.
Zurück zum Zitat Longstaff LM, Sloan K, Stamp N, Scaddan M, Beaver R (2009) Good alignment after total knee arthroplasty leads to faster rehabilitation and better function. J Arthroplast 24:570–578CrossRef Longstaff LM, Sloan K, Stamp N, Scaddan M, Beaver R (2009) Good alignment after total knee arthroplasty leads to faster rehabilitation and better function. J Arthroplast 24:570–578CrossRef
28.
Zurück zum Zitat Huang NF, Dowsey MM, Ee E, Stoney JD, Babazadeh S, Choong PF (2012) Coronal alignment correlates with outcome after total knee arthroplasty: five-year follow-up of a randomized controlled trial. J Arthroplast 27(9):1737–1741CrossRef Huang NF, Dowsey MM, Ee E, Stoney JD, Babazadeh S, Choong PF (2012) Coronal alignment correlates with outcome after total knee arthroplasty: five-year follow-up of a randomized controlled trial. J Arthroplast 27(9):1737–1741CrossRef
29.
Zurück zum Zitat Matziolis G, Adam J, Perka C (2010) Varus malalignment has no influence on clinical outcome in midterm follow-up after total knee replacement. Arch Orthop Trauma Surg 130(12):1487–1491CrossRefPubMed Matziolis G, Adam J, Perka C (2010) Varus malalignment has no influence on clinical outcome in midterm follow-up after total knee replacement. Arch Orthop Trauma Surg 130(12):1487–1491CrossRefPubMed
30.
Zurück zum Zitat Burnett RS, Barrack RL (2013) Computer-assisted total knee arthroplasty is currently of no proven clinical benefit: a systematic review. Clin Orthop Relat Res 471(1):264–276CrossRefPubMedPubMedCentral Burnett RS, Barrack RL (2013) Computer-assisted total knee arthroplasty is currently of no proven clinical benefit: a systematic review. Clin Orthop Relat Res 471(1):264–276CrossRefPubMedPubMedCentral
31.
Zurück zum Zitat Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE (2009) Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop 33(6):1567–1570CrossRefPubMedPubMedCentral Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE (2009) Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop 33(6):1567–1570CrossRefPubMedPubMedCentral
32.
Zurück zum Zitat Kim YH, Kim JS, Choi Y, Kwon OR (2009) Computer-assisted surgical navigation does not improve the alignment and orientation of the components in total knee arthroplasty. J Bone Joint Surg Am 91(1):14–19CrossRefPubMed Kim YH, Kim JS, Choi Y, Kwon OR (2009) Computer-assisted surgical navigation does not improve the alignment and orientation of the components in total knee arthroplasty. J Bone Joint Surg Am 91(1):14–19CrossRefPubMed
33.
Zurück zum Zitat Spencer JM, Chauhan SK, Sloan K, Taylor A, Beaver RJ (2007) Computer navigation versus conventional total knee replacement: no difference in functional results at two years. J Bone Joint Surg Br 89(4):477–480CrossRefPubMed Spencer JM, Chauhan SK, Sloan K, Taylor A, Beaver RJ (2007) Computer navigation versus conventional total knee replacement: no difference in functional results at two years. J Bone Joint Surg Br 89(4):477–480CrossRefPubMed
34.
Zurück zum Zitat Singisetti K, Muthumayandi K, Abual-Rub Z, Weir D (2015) Navigation-assisted versus conventional total knee replacement: no difference in patient-reported outcome measures (PROMs) at 1 and 2 years. Arch Orthop Trauma Surg 135(11):1595–1601CrossRefPubMed Singisetti K, Muthumayandi K, Abual-Rub Z, Weir D (2015) Navigation-assisted versus conventional total knee replacement: no difference in patient-reported outcome measures (PROMs) at 1 and 2 years. Arch Orthop Trauma Surg 135(11):1595–1601CrossRefPubMed
35.
Zurück zum Zitat Oswald MH, Jakob RP, Schneider E, Hoogewoud HM (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplast 8(4):419–426CrossRef Oswald MH, Jakob RP, Schneider E, Hoogewoud HM (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplast 8(4):419–426CrossRef
36.
Zurück zum Zitat Radtke K, Becher C, Noll Y, Ostermeier S (2010) Effect of limb rotation on radiographic alignment in total knee arthroplasties. Arch Orthop Trauma Surg 130(4):451–457CrossRefPubMed Radtke K, Becher C, Noll Y, Ostermeier S (2010) Effect of limb rotation on radiographic alignment in total knee arthroplasties. Arch Orthop Trauma Surg 130(4):451–457CrossRefPubMed
Metadaten
Titel
Measuring long radiographs affects the positioning of femoral components in total knee arthroplasty: a randomized controlled trial
verfasst von
Justinas Stucinskas
Otto Robertsson
Aleksej Lebedev
Hans Wingstrand
Alfredas Smailys
Sarunas Tarasevicius
Publikationsdatum
12.03.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 5/2016
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-016-2434-8

Weitere Artikel der Ausgabe 5/2016

Archives of Orthopaedic and Trauma Surgery 5/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.