Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 4/2021

02.01.2021 | Knee Arthroplasty

Mid-term functional outcomes of patient-specific versus conventional instrumentation total knee arthroplasty: a prospective study

verfasst von: Vikaesh Moorthy, Jerry Yongqiang Chen, Ming Han Lincoln Liow, Pak Lin Chin, Shi-Lu Chia, Ngai Nung Lo, Seng Jin Yeo

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 4/2021

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Patient-specific instrumentation (PSI) utilizes three-dimensional imaging to produce total knee arthroplasty cutting jigs which matches patient’s native anatomy. However, there are limited mid- to long-term studies examining its clinical efficacy. The aim of this study was to compare functional outcomes of PSI surgery versus conventional TKA surgery at 5-year follow-up.

Materials and methods

Sixty patients were prospectively recruited into either the MRI-based PSI or conventional TKA group. Functional outcomes were assessed using the Knee Society Function Score (KSFS), Knee Society Knee Score (KSKS) and Oxford Knee Score (OKS), while quality of life was evaluated with the Physical Component Score (PCS) and Mental Component Score (MCS) of Short-Form 36 and compared between the two groups at 5-year follow-up.

Results

Although the PCS was 7 ± 3 points better in the PSI group preoperatively (p = 0.017), it became 5 ± 2 points worse than the conventional group at 5-year follow-up (p = 0.025). As compared to the PSI group, the conventional group showed a significantly greater improvement in PCS at 5 years as compared to before surgery (p = 0.003). There were no significant differences in KSFS, KSKS, OKS or MCS between the two groups.

Conclusions

PSI TKA did not result in improved functional outcomes or better quality of life when compared to conventional TKA. The additional costs and waiting time associated with PSI are not justifiable and therefore not recommended as an alternative to conventional TKA.

Level of evidence

II.
Literatur
1.
Zurück zum Zitat Kurtz S, Ong K, Lau E, Mowat F, Halpern M (2007) Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am 89(4):780–785PubMedCrossRef Kurtz S, Ong K, Lau E, Mowat F, Halpern M (2007) Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am 89(4):780–785PubMedCrossRef
2.
Zurück zum Zitat Rosenberger RE, Hoser C, Quirbach S, Attal R, Hennerbichler A, Fink C (2008) Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16(3):249–257PubMedCrossRef Rosenberger RE, Hoser C, Quirbach S, Attal R, Hennerbichler A, Fink C (2008) Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16(3):249–257PubMedCrossRef
3.
Zurück zum Zitat Kalairajah Y, Simpson D, Cossey AJ, Verrall GM, Spriggins AJ (2005) Blood loss after total knee replacement: effects of computer-assisted surgery. J Bone Joint Surg Br 87(11):1480–1482PubMedCrossRef Kalairajah Y, Simpson D, Cossey AJ, Verrall GM, Spriggins AJ (2005) Blood loss after total knee replacement: effects of computer-assisted surgery. J Bone Joint Surg Br 87(11):1480–1482PubMedCrossRef
4.
Zurück zum Zitat Kalairajah Y, Cossey AJ, Verrall GM, Ludbrook G, Spriggins AJ (2006) Are systemic emboli reduced in computer-assisted knee surgery?: A prospective, randomised, clinical trial. J Bone Joint Surg Br 88(2):198–202PubMedCrossRef Kalairajah Y, Cossey AJ, Verrall GM, Ludbrook G, Spriggins AJ (2006) Are systemic emboli reduced in computer-assisted knee surgery?: A prospective, randomised, clinical trial. J Bone Joint Surg Br 88(2):198–202PubMedCrossRef
5.
Zurück zum Zitat Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV Jr. (2012) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470(1):99–107PubMedCrossRef Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV Jr. (2012) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470(1):99–107PubMedCrossRef
6.
Zurück zum Zitat Noble JW Jr., Moore CA, Liu N (2012) The value of patient-matched instrumentation in total knee arthroplasty. J Arthroplasty 27(1):153–155PubMedCrossRef Noble JW Jr., Moore CA, Liu N (2012) The value of patient-matched instrumentation in total knee arthroplasty. J Arthroplasty 27(1):153–155PubMedCrossRef
7.
Zurück zum Zitat DeHaan AM, Adams JR, DeHart ML, Huff TW (2014) Patient-specific versus conventional instrumentation for total knee arthroplasty: peri-operative and cost differences. J Arthroplasty 29(11):2065–2069PubMedCrossRef DeHaan AM, Adams JR, DeHart ML, Huff TW (2014) Patient-specific versus conventional instrumentation for total knee arthroplasty: peri-operative and cost differences. J Arthroplasty 29(11):2065–2069PubMedCrossRef
8.
Zurück zum Zitat Bali K, Walker P, Bruce W (2012) Custom-fit total knee arthroplasty: our initial experience in 32 knees. J Arthroplasty 27(6):1149–1154PubMedCrossRef Bali K, Walker P, Bruce W (2012) Custom-fit total knee arthroplasty: our initial experience in 32 knees. J Arthroplasty 27(6):1149–1154PubMedCrossRef
9.
Zurück zum Zitat Beal MD, Delagramaticas D, Fitz D (2016) Improving outcomes in total knee arthroplasty—do navigation or customized implants have a role? J Orthop Surg Res 11(1):60PubMedPubMedCentralCrossRef Beal MD, Delagramaticas D, Fitz D (2016) Improving outcomes in total knee arthroplasty—do navigation or customized implants have a role? J Orthop Surg Res 11(1):60PubMedPubMedCentralCrossRef
10.
Zurück zum Zitat Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM (2004) Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT protocol). J Bone Joint Surg Br 86(6):818–823PubMedCrossRef Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM (2004) Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT protocol). J Bone Joint Surg Br 86(6):818–823PubMedCrossRef
11.
Zurück zum Zitat Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE (2009) Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop 33(6):1567–1570PubMedCrossRef Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE (2009) Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop 33(6):1567–1570PubMedCrossRef
12.
Zurück zum Zitat Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP (2005) Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty 20(3):282–288PubMedCrossRef Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP (2005) Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty 20(3):282–288PubMedCrossRef
13.
Zurück zum Zitat Anderl W, Pauzenberger L, Kolblinger R, Kiesselbach G, Brandl G, Laky B et al (2016) Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA. Knee Surg Sports Traumatol Arthrosc 24(1):102–111PubMedCrossRef Anderl W, Pauzenberger L, Kolblinger R, Kiesselbach G, Brandl G, Laky B et al (2016) Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA. Knee Surg Sports Traumatol Arthrosc 24(1):102–111PubMedCrossRef
14.
Zurück zum Zitat Kotela A, Lorkowski J, Kucharzewski M, Wilk-Franczuk M, Sliwinski Z, Franczuk B et al (2015) Patient-specific CT-based instrumentation versus conventional instrumentation in total knee arthroplasty: a prospective randomized controlled study on clinical outcomes and in-hospital data. Biomed Res Int 2015:165908PubMedPubMedCentralCrossRef Kotela A, Lorkowski J, Kucharzewski M, Wilk-Franczuk M, Sliwinski Z, Franczuk B et al (2015) Patient-specific CT-based instrumentation versus conventional instrumentation in total knee arthroplasty: a prospective randomized controlled study on clinical outcomes and in-hospital data. Biomed Res Int 2015:165908PubMedPubMedCentralCrossRef
15.
Zurück zum Zitat Alcelik I, Blomfield M, Ozturk C, Soni A, Charity R, Acornley A (2017) A comparison of short term radiological alignment outcomes of the patient specific and standard instrumentation for primary total knee arthroplasty: a systematic review and meta-analysis. Acta Orthop Traumatol Turc 51(3):215–222PubMedPubMedCentralCrossRef Alcelik I, Blomfield M, Ozturk C, Soni A, Charity R, Acornley A (2017) A comparison of short term radiological alignment outcomes of the patient specific and standard instrumentation for primary total knee arthroplasty: a systematic review and meta-analysis. Acta Orthop Traumatol Turc 51(3):215–222PubMedPubMedCentralCrossRef
16.
Zurück zum Zitat An VV, Sivakumar BS, Phan K, Levy YD, Bruce WJ (2017) Accuracy of MRI-based vs. CT-based patient-specific instrumentation in total knee arthroplasty: a meta-analysis. J Orthop Sci 22(1):116–120PubMedCrossRef An VV, Sivakumar BS, Phan K, Levy YD, Bruce WJ (2017) Accuracy of MRI-based vs. CT-based patient-specific instrumentation in total knee arthroplasty: a meta-analysis. J Orthop Sci 22(1):116–120PubMedCrossRef
17.
Zurück zum Zitat Lee GC (2016) Patient-specific cutting blocks: of unproven value. Bone Joint J 98-B(1 Suppl A):78–80PubMedCrossRef Lee GC (2016) Patient-specific cutting blocks: of unproven value. Bone Joint J 98-B(1 Suppl A):78–80PubMedCrossRef
18.
Zurück zum Zitat Mannan A, Akinyooye D, Hossain F (2017) A meta-analysis of functional outcomes in patient-specific instrumented knee arthroplasty. J Knee Surg 30(7):668–674PubMedCrossRef Mannan A, Akinyooye D, Hossain F (2017) A meta-analysis of functional outcomes in patient-specific instrumented knee arthroplasty. J Knee Surg 30(7):668–674PubMedCrossRef
19.
Zurück zum Zitat Mannan A, Smith TO (2016) Favourable rotational alignment outcomes in PSI knee arthroplasty: a level 1 systematic review and meta-analysis. Knee 23(2):186–190PubMedCrossRef Mannan A, Smith TO (2016) Favourable rotational alignment outcomes in PSI knee arthroplasty: a level 1 systematic review and meta-analysis. Knee 23(2):186–190PubMedCrossRef
20.
Zurück zum Zitat Kizaki K, Shanmugaraj A, Yamashita F, Simunovic N, Duong A, Khanna V et al (2019) Total knee arthroplasty using patient-specific instrumentation for osteoarthritis of the knee: a meta-analysis. BMC Musculoskelet Disord 20(1):561PubMedPubMedCentralCrossRef Kizaki K, Shanmugaraj A, Yamashita F, Simunovic N, Duong A, Khanna V et al (2019) Total knee arthroplasty using patient-specific instrumentation for osteoarthritis of the knee: a meta-analysis. BMC Musculoskelet Disord 20(1):561PubMedPubMedCentralCrossRef
21.
Zurück zum Zitat Woon JTK, Zeng ISL, Calliess T, Windhagen H, Ettinger M, Waterson HB et al (2018) Outcome of kinematic alignment using patient-specific instrumentation versus mechanical alignment in TKA: a meta-analysis and subgroup analysis of randomised trials. Arch Orthop Trauma Surg 138(9):1293–1303PubMedCrossRef Woon JTK, Zeng ISL, Calliess T, Windhagen H, Ettinger M, Waterson HB et al (2018) Outcome of kinematic alignment using patient-specific instrumentation versus mechanical alignment in TKA: a meta-analysis and subgroup analysis of randomised trials. Arch Orthop Trauma Surg 138(9):1293–1303PubMedCrossRef
22.
Zurück zum Zitat Thienpont E, Schwab PE, Fennema P (2017) Efficacy of patient-specific instruments in total knee arthroplasty: a systematic review and meta-analysis. J Bone Joint Surg Am 99(6):521–530PubMedCrossRef Thienpont E, Schwab PE, Fennema P (2017) Efficacy of patient-specific instruments in total knee arthroplasty: a systematic review and meta-analysis. J Bone Joint Surg Am 99(6):521–530PubMedCrossRef
23.
Zurück zum Zitat Abane L, Anract P, Boisgard S, Descamps S, Courpied JP, Hamadouche M (2015) A comparison of patient-specific and conventional instrumentation for total knee arthroplasty: a multicentre randomised controlled trial. Bone Joint J 97-B(1):56–63PubMedCrossRef Abane L, Anract P, Boisgard S, Descamps S, Courpied JP, Hamadouche M (2015) A comparison of patient-specific and conventional instrumentation for total knee arthroplasty: a multicentre randomised controlled trial. Bone Joint J 97-B(1):56–63PubMedCrossRef
24.
Zurück zum Zitat Boonen B, Schotanus MG, Kerens B, van der Weegen W, Hoekstra HJ, Kort NP (2016) No difference in clinical outcome between patient-matched positioning guides and conventional instrumented total knee arthroplasty two years post-operatively: a multicentre, double-blind, randomised controlled trial. Bone Joint J 98-B(7):939–944PubMedCrossRef Boonen B, Schotanus MG, Kerens B, van der Weegen W, Hoekstra HJ, Kort NP (2016) No difference in clinical outcome between patient-matched positioning guides and conventional instrumented total knee arthroplasty two years post-operatively: a multicentre, double-blind, randomised controlled trial. Bone Joint J 98-B(7):939–944PubMedCrossRef
25.
Zurück zum Zitat Nam D, Park A, Stambough JB, Johnson SR, Nunley RM, Barrack RL (2016) The Mark Coventry Award: custom cutting guides do not improve total knee arthroplasty clinical outcomes at 2 years followup. Clin Orthop Relat Res 474(1):40–46PubMedCrossRef Nam D, Park A, Stambough JB, Johnson SR, Nunley RM, Barrack RL (2016) The Mark Coventry Award: custom cutting guides do not improve total knee arthroplasty clinical outcomes at 2 years followup. Clin Orthop Relat Res 474(1):40–46PubMedCrossRef
26.
Zurück zum Zitat Ollivier M, Parratte S, Lunebourg A, Viehweger E, Argenson JN (2016) The John Insall Award: no functional benefit after unicompartmental knee arthroplasty performed with patient-specific instrumentation: a randomized trial. Clin Orthop Relat Res 474(1):60–68PubMedCrossRef Ollivier M, Parratte S, Lunebourg A, Viehweger E, Argenson JN (2016) The John Insall Award: no functional benefit after unicompartmental knee arthroplasty performed with patient-specific instrumentation: a randomized trial. Clin Orthop Relat Res 474(1):60–68PubMedCrossRef
27.
Zurück zum Zitat Schoenmakers DAL, Schotanus MGM, Boonen B, Kort NP (2018) Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases. Knee Surg Sports Traumatol Arthrosc 26(6):1800–1804PubMedCrossRef Schoenmakers DAL, Schotanus MGM, Boonen B, Kort NP (2018) Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases. Knee Surg Sports Traumatol Arthrosc 26(6):1800–1804PubMedCrossRef
28.
Zurück zum Zitat Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the knee society clinical rating system. Clin Orthop Relat Res 248:13–14CrossRef Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the knee society clinical rating system. Clin Orthop Relat Res 248:13–14CrossRef
29.
Zurück zum Zitat Dawson J, Fitzpatrick R, Murray D, Carr A (1998) Questionnaire on the perceptions of patients about total knee replacement. J Bone Joint Surg Br 80(1):63–69PubMedCrossRef Dawson J, Fitzpatrick R, Murray D, Carr A (1998) Questionnaire on the perceptions of patients about total knee replacement. J Bone Joint Surg Br 80(1):63–69PubMedCrossRef
30.
Zurück zum Zitat Ware JE Jr., Sherbourne CD (1992) The MOS 36-item short-form health survey (SF-36). I. Conceptual framework and item selection. Med Care 30(6):473–483PubMedCrossRef Ware JE Jr., Sherbourne CD (1992) The MOS 36-item short-form health survey (SF-36). I. Conceptual framework and item selection. Med Care 30(6):473–483PubMedCrossRef
31.
Zurück zum Zitat Ware JE, Kosinski M, Keller SD (1994) SF-36 physical and mental summary scales: a user’s manual. Health Institute, New England Medical Center, Boston Ware JE, Kosinski M, Keller SD (1994) SF-36 physical and mental summary scales: a user’s manual. Health Institute, New England Medical Center, Boston
32.
Zurück zum Zitat Jenkinson C (1998) The SF-36 physical and mental health summary measures: an example of how to interpret scores. J Health Serv Res Policy 3(2):92–96PubMedCrossRef Jenkinson C (1998) The SF-36 physical and mental health summary measures: an example of how to interpret scores. J Health Serv Res Policy 3(2):92–96PubMedCrossRef
34.
Zurück zum Zitat Lee WC, Kwan YH, Chong HC, Yeo SJ (2017) The minimal clinically important difference for Knee Society Clinical Rating System after total knee arthroplasty for primary osteoarthritis. Knee Surg Sports Traumatol Arthrosc 25(11):3354–3359PubMedCrossRef Lee WC, Kwan YH, Chong HC, Yeo SJ (2017) The minimal clinically important difference for Knee Society Clinical Rating System after total knee arthroplasty for primary osteoarthritis. Knee Surg Sports Traumatol Arthrosc 25(11):3354–3359PubMedCrossRef
35.
Zurück zum Zitat Harvie P, Sloan K, Beaver RJ (2012) Computer navigation vs conventional total knee arthroplasty: five-year functional results of a prospective randomized trial. J Arthroplasty 27(5):667–72e1CrossRef Harvie P, Sloan K, Beaver RJ (2012) Computer navigation vs conventional total knee arthroplasty: five-year functional results of a prospective randomized trial. J Arthroplasty 27(5):667–72e1CrossRef
36.
Zurück zum Zitat Hossain FS, Konan S, Patel S, Rodriguez-Merchan EC, Haddad FS (2015) The assessment of outcome after total knee arthroplasty: are we there yet? Bone Joint J 97-B(1):3–9PubMedCrossRef Hossain FS, Konan S, Patel S, Rodriguez-Merchan EC, Haddad FS (2015) The assessment of outcome after total knee arthroplasty: are we there yet? Bone Joint J 97-B(1):3–9PubMedCrossRef
37.
Zurück zum Zitat Mizner RL, Petterson SC, Clements KE, Zeni JA Jr., Irrgang JJ, Snyder-Mackler L (2011) Measuring functional improvement after total knee arthroplasty requires both performance-based and patient-report assessments: a longitudinal analysis of outcomes. J Arthroplasty 26(5):728–737PubMedCrossRef Mizner RL, Petterson SC, Clements KE, Zeni JA Jr., Irrgang JJ, Snyder-Mackler L (2011) Measuring functional improvement after total knee arthroplasty requires both performance-based and patient-report assessments: a longitudinal analysis of outcomes. J Arthroplasty 26(5):728–737PubMedCrossRef
38.
Zurück zum Zitat Leon-Munoz VJ, Martinez-Martinez F, Lopez-Lopez M, Santonja-Medina F (2019) Patient-specific instrumentation in total knee arthroplasty. Expert Rev Med Devices 16(7):555–567PubMedCrossRef Leon-Munoz VJ, Martinez-Martinez F, Lopez-Lopez M, Santonja-Medina F (2019) Patient-specific instrumentation in total knee arthroplasty. Expert Rev Med Devices 16(7):555–567PubMedCrossRef
39.
Zurück zum Zitat Chen JY, Yeo SJ, Yew AK, Tay DK, Chia SL, Lo NN et al (2014) The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22(3):630–635PubMedCrossRef Chen JY, Yeo SJ, Yew AK, Tay DK, Chia SL, Lo NN et al (2014) The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22(3):630–635PubMedCrossRef
40.
Zurück zum Zitat Wu XD, Xiang BY, Schotanus MGM, Liu ZH, Chen Y, Huang W (2017) CT- versus MRI-based patient-specific instrumentation for total knee arthroplasty: a systematic review and meta-analysis. Surgeon 15(6):336–348PubMedCrossRef Wu XD, Xiang BY, Schotanus MGM, Liu ZH, Chen Y, Huang W (2017) CT- versus MRI-based patient-specific instrumentation for total knee arthroplasty: a systematic review and meta-analysis. Surgeon 15(6):336–348PubMedCrossRef
41.
Zurück zum Zitat Abdel MP, Parratte S, Blanc G, Ollivier M, Pomero V, Viehweger E et al (2014) No benefit of patient-specific instrumentation in TKA on functional and gait outcomes: a randomized clinical trial. Clin Orthop Relat Res 472(8):2468–2476PubMedPubMedCentralCrossRef Abdel MP, Parratte S, Blanc G, Ollivier M, Pomero V, Viehweger E et al (2014) No benefit of patient-specific instrumentation in TKA on functional and gait outcomes: a randomized clinical trial. Clin Orthop Relat Res 472(8):2468–2476PubMedPubMedCentralCrossRef
42.
Zurück zum Zitat Pietsch M, Djahani O, Zweiger C, Plattner F, Radl R, Tschauner C et al (2013) Custom-fit minimally invasive total knee arthroplasty: effect on blood loss and early clinical outcomes. Knee Surg Sports Traumatol Arthrosc 21(10):2234–2240PubMedCrossRef Pietsch M, Djahani O, Zweiger C, Plattner F, Radl R, Tschauner C et al (2013) Custom-fit minimally invasive total knee arthroplasty: effect on blood loss and early clinical outcomes. Knee Surg Sports Traumatol Arthrosc 21(10):2234–2240PubMedCrossRef
43.
Zurück zum Zitat Zhu M, Chen JY, Chong HC, Yew AKS, Foo LSS, Chia SL et al (2017) Outcomes following total knee arthroplasty with CT-based patient-specific instrumentation. Knee Surg Sports Traumatol Arthrosc 25(8):2567–2572PubMedCrossRef Zhu M, Chen JY, Chong HC, Yew AKS, Foo LSS, Chia SL et al (2017) Outcomes following total knee arthroplasty with CT-based patient-specific instrumentation. Knee Surg Sports Traumatol Arthrosc 25(8):2567–2572PubMedCrossRef
Metadaten
Titel
Mid-term functional outcomes of patient-specific versus conventional instrumentation total knee arthroplasty: a prospective study
verfasst von
Vikaesh Moorthy
Jerry Yongqiang Chen
Ming Han Lincoln Liow
Pak Lin Chin
Shi-Lu Chia
Ngai Nung Lo
Seng Jin Yeo
Publikationsdatum
02.01.2021
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 4/2021
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-020-03729-4

Weitere Artikel der Ausgabe 4/2021

Archives of Orthopaedic and Trauma Surgery 4/2021 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Lever-Sign-Test hilft beim Verdacht auf Kreuzbandriss

15.05.2024 Vordere Kreuzbandruptur Nachrichten

Mit dem Hebelzeichen-Test lässt sich offenbar recht zuverlässig feststellen, ob ein vorderes Kreuzband gerissen ist. In einer Metaanalyse war die Vorhersagekraft vor allem bei positivem Testergebnis hoch.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.