Congenital hip dysplasia treated by total hip arthroplasty using cementless tapered stem in patients younger than 50 years old: results after 12-years follow-up

verfasst von: Cesare Faldini, Maria Teresa Miscione, Mohammadreza Chehrassan, Francesco Acri, Camilla Pungetti, Michele d’Amato, Deianira Luciani, Sandro Giannini

Erschienen in: Journal of Orthopaedics and Traumatology | Ausgabe 4/2011

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN

Abstract

Background

Congenital hip dysplasia may lead to severe acetabular and femoral abnormalities that can make total hip arthroplasty a challenging procedure. We assessed a series of patients affected by developmental hip dysplasia treated with total hip arthroplasty using cementless tapered stem and here we report the outcomes at long-term follow-up.

Materials and methods

Twenty-eight patients (24 women and 4 men) aged between 44 and 50 years (mean 47 years) were observed. Clinical evaluation was rated with the Harris Hip Score. Radiographic evaluation consisted in standard anteroposterior and axial view radiographs of the hip. According to Crowe’s classification, 16 hips presented dysplasia grade 1, 14 grade 2, and 4 grade 3. All patients were treated with total hip arthroplasty using a cementless tapered stem (Wagner Cone Prosthesis). Six patients were operated bilaterally, with a totally of 34 hips operated. After surgery, the patients were clinically and radiographically checked at 3, 6, and 12 months and yearly thereafter until an average follow-up of 12 years (range 10–14 years).

Results

Average Harris Hip Score was 56 ± 9 (range 45–69) preoperatively, 90 ± 9 (range 81–100) 12 months after surgery, and 91 ± 8 (range 83–100) at last follow-up. Radiographic evaluation demonstrated excellent osteointegration of the implants. Signs of bone resorption were present in 6 hips, nevertheless no evidence of loosening was observed and none of the implants has been revised.

Conclusions

Even in dysplasic femur, the tapered stem allowed adequate stability and orientation of the implant. We consider tapered stem a suitable option for total hip arthroplasty in developmental hip dysplasia, also in case of young patients, thanks to the favourable long-term results.

Introduction

Congenital hip dysplasia (or developmental hip dysplasia) consists of an abnormal development of the hip joint characterized by anatomical alterations involving both the acetabulum and the femur. If not diagnosed and adequately treated during childhood, congenital hip dysplasia may lead to early functional impairment in young adults: the acetabulum typically presents reduced depth with superior deficiency; the femur usually presents deformed head, short neck with excessive anteversion, small and unusually shaped medullary canal, with a smaller medio–lateral diameter respect to its antero-posterior, and more often a greater trochanter located more posteriorly [1, 2]. The consequent mismatch of the articular surfaces, associated with the shortening of the lower limb and the unbalanced abductor muscle strength, produces overtime pain, limping and finally secondary arthritis of the hip joint [2] (Figs. 1, 2).
The characteristic pathological anatomy, the early onset of symptoms and degenerative joint changes, and the relatively young age of the patients make the treatment of developmental hip dysplasia in adults a challenge for surgery [36]: many surgical strategies, including acetabular reconstruction, femoral osteotomies and joint arthroplasty, have been proposed over the years. Regarding total hip arthroplasty in developmental hip dysplasia, the treatment of choice is still widely debated [725]. The anatomical alterations make the selection of the prosthesis complex and the implant technically demanding. Moreover, previous surgery (e.g. femoral osteotomies, acetabuloplasty) can highly increase the difficulty of joint replacement. Finally, the relatively young age of the patients highlights the problem of the long-term survival of the implants [8, 1115].
Most part of literature suggests to place the acetabular cup in the anatomical position in order to equalize lower limb length and to achieve adequate abductor muscle strength [7, 21, 22, 26]. However, this procedure requires an adequate coverage of the acetabulum, otherwise reconstruction of the superior deficiency or medialization of a smaller prosthetic component is necessary [16, 22, 26, 27]. Many authors report longer duration of uncemented implants compared to cemented ones, and a simpler revision surgery in case of implant loosening; thus, the use of cementless stems in young patients is suggested [8, 14, 15, 20, 24, 25]. Anyway, the implant of anatomical cementless stems appears difficult in case of severe femoral deformity, exposing the patient to greater risks of intraoperative fractures and incorrect placement of the implant [28, 29]. Moreover, the anteversion of the implanted acetabular component influences how much anteversion can be accepted on the femoral side without compromising hip stability [19, 27]. We believe that these problems could be avoided using tapered stems, which enable the use of a femoral cementless implant even in case of developmental hip dysplasia. The aim of this study is to review the results of a series of patients younger then 50 years old affected by developmental hip dysplasia treated by total hip arthroplasty using a cementless tapered stem, at long-term follow-up.

Materials and methods

Forty-six patients affected by developmental hip dysplasia were treated between 1995 and 1998 with total hip arthroplasty. Inclusion criteria were mono- or bilateral congenital hip dysplasia, with pain. Exclusion criteria were any previous surgery and patients older than 50 years old. Eighteen patients had been previously treated by femoral osteotomy, so they were excluded. Twenty-eight patients (24 females and 4 males) were included in the study. Six of them underwent surgery bilaterally, for a total of 34 hips observed. Average age at time of surgery was 47 years (range 44–50 years). This study conforms to the Declaration of Helsinki as revised in 2008 and was authorized by the ethical committee of authors’ institution. All patients gave the informed consent to this study.
Preoperatively, all patients were evaluated clinically and radiographically. For each patient, the complete medical history was collected and pain and grade of disability were assessed in terms of limitation of the hip range of motion, limb length discrepancy, and restrictions on walking and daily activities. Clinical evaluation was rated with the Harris Hip Score [31]. For all patients, standard radiographs of the pelvis in anteroposterior view and of the affected hip in axial view were obtained (Figs. 1, 2). On radiographs, the degree of dysplasia was determined using the system of Crowe [32], and according to this, 16 hips presented dysplasia grade 1, 14 grade 2, and 4 grade 3. The transverse diameter of the medullary canal and the thickness of the cortex of the femur were also assessed. The appropriate implant was chosen by preoperative templating.
Surgery was performed under general or spinal anaesthesia. In all cases, postero-lateral approach was used, with the patient placed on the contralateral side. One cm posteriorly from the tip of the greater trochanter, a skin incision, extended straight for approximately 15 cm, was performed. The subcutaneous tissue and the gluteal fascia were incised and retracted medially together with the gluteus maximus. The gluteus medius was retracted and the short extrarotators were isolated and detached. The insertion of the quadratus was spared if possible. Capsulotomy was performed, and the hip was dislocated by pulling, flexing, and internally rotating the lower limb. The femoral neck was resected at its base and the femoral head was removed.
The primitive acetabulum was reamed, and a small, uncemented, press-fit cup was applied in or close to the anatomical position. Metal-polyethylene coupling was used in 27 cases, while in 7 cases ceramic–ceramic coupling was used.
Since the dysplastic femur presents abnormal neck anteversion, in this series we did not consider the femoral neck to be a suitable reference for stem placement, therefore the correct orientation of the stem was determined referring to the condylar plane. With the hip 45° flexed and 90° internally rotated and the knee 90° flexed, the condylar plane is almost perpendicular to the longitudinal tibial axis: anteversion was determined by using the tibial axis as a reference point. A Steinmann pin was inserted into the tip of the greater trochanter, parallel to the longitudinal tibial axis.
The medullary canal was reamed using tapered reamers of progressively increasing size until the planned size was achieved and until resistance of the reamer against the femur cortex was felt. The depth of the reamer was determined by the Steinmann pin, which should correspond to the notch on the reamer. Then a Wagner Cone Prosthesis uncemented stem was inserted by guiding it with its appropriate device, aiming to obtain about 10–20° of anteversion.
After the hip has been reduced, stability and range of motion were assessed, and limb length checked in comparison to the contralateral limb.
A drainage was applied, the extrarotators were reinserted, and the gluteal fascia, the subcutaneous tissue, and the skin were sutured.
The first day of postoperative care, the drainage was removed and physiotherapy was begun. The physical therapy was aided by a physiotherapist to make passive and active movements of the operated limb, to stand up and walk with the use of a walking frame. Initially a dragged load on the operated limb was allowed, then partial weight-bearing was allowed with the use of two crutches. All patients were discharged from 6 to 9 days (mean 7 days) after surgery, and then they were checked in the outpatient department after 1 month, when they were invited to dismiss one of the two crutches. Afterwards, all patients were checked at 2 months from surgery, when they were asked to progressively abandon the other crutch and total weight-bearing was allowed. The patients were checked clinically and radiographically 3, 6 and 12 months after surgery (Fig. 3) and yearly thereafter until an average follow-up of 12 years (range 10–14 years) (Figs. 4, 5). Twelve months after surgery and at last available follow-up, the clinical outcome was rated using the Harris Hip Score. On radiographs, the presence of osteolysis, defined as radiolucent lines surrounding the stem (according to Gruen [33]) was carefully evaluated. Moreover, stress shielding (as described by Engh [34]) was assessed.
All continuous data were expressed as mean and standard deviation of the mean, and the paired T test was performed to compare preoperative and postoperative scores; p < 0.05 was considered significant.

Results

One intraoperative complication was reported: one intraoperative proximal femur fracture occurred, involving the greater trochanter, and treated by cerclage wiring and dragged load on the operated limb the first 5 weeks after surgery. No early infection or wound healing problems occurred. One patient underwent a deep venous thrombosis that was adequately managed on postoperative care and resolved without sequelae. One dislocation occurred, treated with close reduction and a hip brace, without the need for further surgery, and no recurrence was observed. No septic or aseptic loosening of the implants was observed.
Average Harris Hip Score was 56 ± 9 (range 45–69) preoperatively, 90 ± 9 (range 81–100) at 12 months after surgery, and 91 ± 8 (range 83–100) at last follow-up.
All patients showed clinical improvement after surgery. All patients walked normally without any help at 3 months after surgery. Only 2 patients with a limb length discrepancy of about 2 cm required the use of a shoe lift; however, it was well tolerated. This device satisfactorily solved the problem and allowed the patients to walk normally without limping. All patients declared that they were satisfied with the results of surgery in terms of hip function and relief from pain.
Radiographic evaluation demonstrated excellent osteointegration of the implants in most cases.
At last follow-up, bone resorption and stress shielding were noticeable in 6 hips (grade 1 in 4 hips, grade 2 in 2 hips, as described by Engh [34]), nevertheless in these cases no definite clinical or radiographic evidence of implant loosening was observed. None of the implants has been revised. Clinic, limb length discrepancy and radiographic resorption were not related to the grade of dysplasia.

Discussion

Congenital hip dysplasia can lead to severe anatomical alterations of the hip joint. These alterations increase the difficulty of joint replacement, and may also threaten the long-term survival of the prosthetic implant. Appropriate selection of the prosthesis and a carefully conducted surgical procedure are thus essential to ensure the best result and the longevity of the implant. Total hip arthroplasty using a cementless tapered stem demonstrated to be effective for the treatment of developmental hip dysplasia, allowing relief from symptoms and improvement of hip function, with durable outcomes at long-term follow-up [30].
The disadvantages of cementless anatomical stems are reduced thanks to the characteristics of the tapered stem, allowing to obtain adequate stability and good orientation of the implant, even in a displastic femur. In our series, radiographic evaluation at follow-up showed in most cases osteointegration of the stem in the proximal region of the femur. We believe this phenomenon is due to the conical geometry of the prosthesis. In fact, in the tapered stem, the surface per unit of length increases with the diameter, and the surface area is greater in the proximal part of the stem than in the distal part. With a continuous surface contact between the stem and the bony interface, a uniform load transfer per unit of area can be assumed; therefore, since the load is distributed per surface unit, in a conical prosthesis the load is greater in the proximal region compared to the distal one. We believe that this feature may prevent stress-shielding and load by-pass in a proximal–distal direction, avoiding bone resorption of the proximal portion of the femur with subsequent secondary instability of the implant, even if the role of stress-shielding (and particularly its influence on clinical outcome) is still not clearly demonstrated [20, 3442]. Besides, by avoiding greater and abnormal loads on the distal portion of the stem and the resulting pedestal formation, the onset of thigh pain is prevented; which conversely is reported after cementless total hip arthroplasty, especially in patients treated with long prosthetic stems [23, 43, 44]. We are also aware that the tapered prosthesis should not be used in cylindrical femurs with thin cortices, because we believe it would be inappropriate to weaken the cortex by conically reaming the canal.
In case of anatomical stems with prismatic cross-sections, the altered shape of the medullary canal could force the implant to rotate, and the surgeon might be unable to control the anteversion angle [45]. This feature accounts for the higher rate of intraoperative fracture and incorrect placement and fitting reported with the use of cementless anatomical stems, which sometimes lead to implant an undersized prosthesis [22, 23, 28, 29]. On the other hand, the position of the tapered stem with regards to rotation (anteversion or retroversion) is not determined by the anatomical characteristics of the dysplastic femoral epiphysis: the circular section of the tapered stem, provided with 8 longitudinal sharp ribs, allows the surgeon to choose the degree of anteversion that he considers as better.
The stem used in this series presented a fixed neck–diaphysis angle of 135°, which is rather similar to the coxa valga angle. However, in some cases, this was unfavourable for reconstructing the correct offset in hips with a reduced neck shaft angle. Therefore, we believe that it would be useful to have a range of stems with more varus deviation to be able to place the gluteal muscles under adequate tension without lengthening the limb.
In conclusion, by the using of tapered cementless stems, it is possible to achieve adequate press-fit and correct placement of the implant, especially in terms of anteversion, even in case of severe anatomical anomalies. This makes the tapered stem a suitable option for total hip arthroplasty in congenital hip dysplasia, also in case of young patients, with a low grade of complications and an optimal implant survival rate at long-term.

Acknowledgments

The authors thank Professor Alessandro Faldini, University of Pisa, for sharing his experience.

Conflict of interest

None.

Open Access

This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution and reproduction in any medium, provided the original author(s) and source are credited.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 2.0 International License (https://​creativecommons.​org/​licenses/​by/​2.​0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Literatur
1.
Zurück zum Zitat Sugano N, Noble PC, Kamaric E, Salama JK, Ochi T, Tullos HS (1998) The morphology of the femur in developmental dysplasia of the hip. J Bone Joint Surg Br 80:711–719PubMedCrossRef Sugano N, Noble PC, Kamaric E, Salama JK, Ochi T, Tullos HS (1998) The morphology of the femur in developmental dysplasia of the hip. J Bone Joint Surg Br 80:711–719PubMedCrossRef
2.
Zurück zum Zitat Noble PC, Kamaric E, Sugano N, Matsubara M, Harada Y, Ohzono K, Paravic V (2003) Three-dimensional shape of the dysplastic femur: implications for THR. Clin Orthop Relat Res 417:27–40PubMed Noble PC, Kamaric E, Sugano N, Matsubara M, Harada Y, Ohzono K, Paravic V (2003) Three-dimensional shape of the dysplastic femur: implications for THR. Clin Orthop Relat Res 417:27–40PubMed
3.
Zurück zum Zitat Sanchez-Sotelo J, Trousdale RT, Berry DJ, Cabanela ME (2002) Surgical treatment of developmental dysplasia of the hip in adults: I. Nonarthroplasty options. J Am Acad Orthop Surg 10:321–333PubMed Sanchez-Sotelo J, Trousdale RT, Berry DJ, Cabanela ME (2002) Surgical treatment of developmental dysplasia of the hip in adults: I. Nonarthroplasty options. J Am Acad Orthop Surg 10:321–333PubMed
4.
Zurück zum Zitat Flecher X, Aubaniac JM, Parratte S, Argenson JN (2007) Is there a need for conservative surgery in DDH adult patients? Lessons learned after 30 years experience. Hip Int 17:83–90 Flecher X, Aubaniac JM, Parratte S, Argenson JN (2007) Is there a need for conservative surgery in DDH adult patients? Lessons learned after 30 years experience. Hip Int 17:83–90
5.
Zurück zum Zitat Parmar V, Kumar AJS (2009) The importance of surgical education in the accuracy of implant placement during hip fracture fixation. J Orthopaed Traumatol 10(2):59–61CrossRef Parmar V, Kumar AJS (2009) The importance of surgical education in the accuracy of implant placement during hip fracture fixation. J Orthopaed Traumatol 10(2):59–61CrossRef
6.
Zurück zum Zitat D’Arrigo C, Speranza A, Monaco E, Carcangiu A, Ferretti A (2009) Learning curve in tissue sparing total hip replacement: comparison between different approaches. J Orthopaed Traumatol 10(1):47–54CrossRef D’Arrigo C, Speranza A, Monaco E, Carcangiu A, Ferretti A (2009) Learning curve in tissue sparing total hip replacement: comparison between different approaches. J Orthopaed Traumatol 10(1):47–54CrossRef
7.
Zurück zum Zitat Dunn HK, Hess WE (1976) Total hip reconstruction in chronically dislocated hips. J Bone Joint Surg Am 58:838–845PubMed Dunn HK, Hess WE (1976) Total hip reconstruction in chronically dislocated hips. J Bone Joint Surg Am 58:838–845PubMed
8.
Zurück zum Zitat Collis DK (1991) Long-term (twelve to eighteen-year) follow-up of cemented total hip replacements in patients who were less than fifty years old. A follow- up note. J Bone Joint Surg Am 73:593–597PubMed Collis DK (1991) Long-term (twelve to eighteen-year) follow-up of cemented total hip replacements in patients who were less than fifty years old. A follow- up note. J Bone Joint Surg Am 73:593–597PubMed
9.
Zurück zum Zitat Jasty M, Anderson MJ, Harris WH (1995) Total hip replacement for developmental dysplasia of the hip. Clin Orthop Rel Res 311:40–45 Jasty M, Anderson MJ, Harris WH (1995) Total hip replacement for developmental dysplasia of the hip. Clin Orthop Rel Res 311:40–45
10.
Zurück zum Zitat MacKenzie JR, Kelley SS, Johnston RC (1996) Total hip replacement for coxarthrosis secondary to congenital dysplasia and dislocation of the hip. Long-term results. J Bone Joint Surg Am 78:55–61PubMed MacKenzie JR, Kelley SS, Johnston RC (1996) Total hip replacement for coxarthrosis secondary to congenital dysplasia and dislocation of the hip. Long-term results. J Bone Joint Surg Am 78:55–61PubMed
11.
Zurück zum Zitat Bjerkholt H, Høvik Ø, Reikerås O (2010) Direct comparison of polyethylene wear in cemented and uncemented acetabular cups. J Orthopaed Traumatol 11(3):155–158CrossRef Bjerkholt H, Høvik Ø, Reikerås O (2010) Direct comparison of polyethylene wear in cemented and uncemented acetabular cups. J Orthopaed Traumatol 11(3):155–158CrossRef
12.
Zurück zum Zitat Bjørgu Kl, Novicoff WM, Andersen ST, Brevig K, Thu F, Wiig M, Åhlund O (2010) No differences in outcomes between cemented and uncemented acetabular components after 12–14 years: results from a randomized controlled trial comparing Duraloc with Charnley cups. J Orthopaed Traumatol 11(1):37–45CrossRef Bjørgu Kl, Novicoff WM, Andersen ST, Brevig K, Thu F, Wiig M, Åhlund O (2010) No differences in outcomes between cemented and uncemented acetabular components after 12–14 years: results from a randomized controlled trial comparing Duraloc with Charnley cups. J Orthopaed Traumatol 11(1):37–45CrossRef
13.
Zurück zum Zitat Randhawa K, Hossain FS, Smith B, Mauffrey C, Lawrence T (2009) A prospective study of hip revision surgery using the Exeter long-stem prosthesis: function, subsidence, and complications for 57 patients. J Orthopaed Traumatol 10(4):159–165CrossRef Randhawa K, Hossain FS, Smith B, Mauffrey C, Lawrence T (2009) A prospective study of hip revision surgery using the Exeter long-stem prosthesis: function, subsidence, and complications for 57 patients. J Orthopaed Traumatol 10(4):159–165CrossRef
14.
Zurück zum Zitat Capello WN, D’Antonio JA, Feinberg JR, Manley MT (1997) Hydroxyapatite-coated total hip femoral components in patients less than fifty years old. Clinical and radiographic results after five to eight years of follow-up. J Bone Joint Surg Am 79:1023–1029PubMed Capello WN, D’Antonio JA, Feinberg JR, Manley MT (1997) Hydroxyapatite-coated total hip femoral components in patients less than fifty years old. Clinical and radiographic results after five to eight years of follow-up. J Bone Joint Surg Am 79:1023–1029PubMed
15.
Zurück zum Zitat Sporer SM, Callaghan JJ, Olejniczak JP, Goetz DD, Johnston RC (1998) Hybrid total hip arthroplasty in patients under the age of fifty: a five- to ten-year follow-up. J Arthroplasty 13:485–491PubMedCrossRef Sporer SM, Callaghan JJ, Olejniczak JP, Goetz DD, Johnston RC (1998) Hybrid total hip arthroplasty in patients under the age of fifty: a five- to ten-year follow-up. J Arthroplasty 13:485–491PubMedCrossRef
16.
Zurück zum Zitat Stans AA, Pagnano MW, Shaughnessy WJ, Hanssen AD (1998) Results of total hip arthroplasty for Crowe type III developmental hip dysplasia. Clin Orthop Rel Res 348:149–157CrossRef Stans AA, Pagnano MW, Shaughnessy WJ, Hanssen AD (1998) Results of total hip arthroplasty for Crowe type III developmental hip dysplasia. Clin Orthop Rel Res 348:149–157CrossRef
17.
Zurück zum Zitat Chareancholvanich K, Becker DA, Gustilo RB (1999) Treatment of congenital dislocated hip by arthroplasty with femoral shortening. Clin Orthop Rel Res 360:127–135CrossRef Chareancholvanich K, Becker DA, Gustilo RB (1999) Treatment of congenital dislocated hip by arthroplasty with femoral shortening. Clin Orthop Rel Res 360:127–135CrossRef
18.
Zurück zum Zitat Kerboull M, Hamadouche M, Kerboull L (2001) Total hip arthroplasty for Crowe type IV developmental hip dysplasia: a long term follow-up study. J Arthroplasty 16:170–176PubMedCrossRef Kerboull M, Hamadouche M, Kerboull L (2001) Total hip arthroplasty for Crowe type IV developmental hip dysplasia: a long term follow-up study. J Arthroplasty 16:170–176PubMedCrossRef
19.
Zurück zum Zitat Sanchez-Sotelo J, Berry DJ, Trousdale RT, Cabanela ME (2002) Surgical treatment of developmental dysplasia of the hip in adults: II. Arthroplasty options. J Am Acad Orthop Surg 10:334–344PubMed Sanchez-Sotelo J, Berry DJ, Trousdale RT, Cabanela ME (2002) Surgical treatment of developmental dysplasia of the hip in adults: II. Arthroplasty options. J Am Acad Orthop Surg 10:334–344PubMed
20.
Zurück zum Zitat Teloken MA, Bissett G, Hozack WJ, Sharkey PF, Rothman RH (2002) Ten to fifteen-year follow-up after total hip arthroplasty with a tapered cobalt-chromium femoral component (tri-lock) inserted without cement. J Bone Joint Surg Am 84:2140–2144PubMed Teloken MA, Bissett G, Hozack WJ, Sharkey PF, Rothman RH (2002) Ten to fifteen-year follow-up after total hip arthroplasty with a tapered cobalt-chromium femoral component (tri-lock) inserted without cement. J Bone Joint Surg Am 84:2140–2144PubMed
21.
Zurück zum Zitat Hartofilakidis G, Karachalios T (2004) Total hip arthroplasty for congenital hip disease. J Bone Joint Surg Am 86:242–250PubMed Hartofilakidis G, Karachalios T (2004) Total hip arthroplasty for congenital hip disease. J Bone Joint Surg Am 86:242–250PubMed
22.
Zurück zum Zitat Perka C, Fischer U, Taylor WR, Matziolis G (2004) Developmental hip dysplasia treated with total hip arthroplasty with a straight stem and a threaded cup. J Bone Joint Surg Am 86:312–319PubMed Perka C, Fischer U, Taylor WR, Matziolis G (2004) Developmental hip dysplasia treated with total hip arthroplasty with a straight stem and a threaded cup. J Bone Joint Surg Am 86:312–319PubMed
23.
Zurück zum Zitat Kim YH, Kim JS (2005) Total hip arthroplasty in adult patients who had developmental dysplasia of the hip. J Arthroplasty 20:1029–1036PubMedCrossRef Kim YH, Kim JS (2005) Total hip arthroplasty in adult patients who had developmental dysplasia of the hip. J Arthroplasty 20:1029–1036PubMedCrossRef
24.
Zurück zum Zitat Eskelinen A, Helenius I, Remes V, Ylinen P, Tallroth K, Paavilainen T (2006) Cementless total hip arthroplasty in patients with high congenital hip dislocation. J Bone Joint Surg Am 88:80–91PubMedCrossRef Eskelinen A, Helenius I, Remes V, Ylinen P, Tallroth K, Paavilainen T (2006) Cementless total hip arthroplasty in patients with high congenital hip dislocation. J Bone Joint Surg Am 88:80–91PubMedCrossRef
25.
Zurück zum Zitat Biant LC, Bruce WJ, Assini JB, Walker PM, Walsh WR (2009) Primary total hip arthroplasty in severe developmental dysplasia of the hip. Ten-year results using a cementless modular stem. J Arthroplasty 24:27–32PubMedCrossRef Biant LC, Bruce WJ, Assini JB, Walker PM, Walsh WR (2009) Primary total hip arthroplasty in severe developmental dysplasia of the hip. Ten-year results using a cementless modular stem. J Arthroplasty 24:27–32PubMedCrossRef
26.
Zurück zum Zitat Karachalios T, Hartofilakidis G (2010) Congenital hip disease in adults: terminology, classification, pre-operative planning and management. J Bone Joint Surg Br 92:914–921PubMedCrossRef Karachalios T, Hartofilakidis G (2010) Congenital hip disease in adults: terminology, classification, pre-operative planning and management. J Bone Joint Surg Br 92:914–921PubMedCrossRef
27.
Zurück zum Zitat Hirakawa K, Mitsugi N, Koshino T, Saito T, Hirasawa Y, Kubo T (1998) Effect of acetabular cup position and orientation in cemented total hip arthroplasty. Clin Orthop Rel Res 348:149–157 Hirakawa K, Mitsugi N, Koshino T, Saito T, Hirasawa Y, Kubo T (1998) Effect of acetabular cup position and orientation in cemented total hip arthroplasty. Clin Orthop Rel Res 348:149–157
28.
Zurück zum Zitat Fitzgerald RH Jr, Brindley GW, Kavanagh BF (1998) The uncemented total hip arthroplasty. Intraoperative femoral fractures. Clin Orthop Rel Res 235:61–66 Fitzgerald RH Jr, Brindley GW, Kavanagh BF (1998) The uncemented total hip arthroplasty. Intraoperative femoral fractures. Clin Orthop Rel Res 235:61–66
29.
Zurück zum Zitat Moroni A, Faldini C, Piras F, Giannini S (2000) Risk factors for intraoperative femoral fractures during total hip replacement. Ann Chir Gynaecol 89:113–118PubMed Moroni A, Faldini C, Piras F, Giannini S (2000) Risk factors for intraoperative femoral fractures during total hip replacement. Ann Chir Gynaecol 89:113–118PubMed
30.
Zurück zum Zitat Faldini C, Nanni M, Leonetti D, Miscione MT, Acri F, Giannini S (2011) Total hip arthroplasty in developmental hip dysplasia using cementless tapered stem. Results after a minimum 10-year follow-up. Hip Int 21(4):415–420PubMedCrossRef Faldini C, Nanni M, Leonetti D, Miscione MT, Acri F, Giannini S (2011) Total hip arthroplasty in developmental hip dysplasia using cementless tapered stem. Results after a minimum 10-year follow-up. Hip Int 21(4):415–420PubMedCrossRef
31.
Zurück zum Zitat Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51:737–755PubMed Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51:737–755PubMed
32.
Zurück zum Zitat Crowe JF, Mani VJ, Ranawat CS (1979) Total hip replacement in congenital dislocation and dysplasia of the hip. J Bone Joint Surg Am 61:15–23PubMed Crowe JF, Mani VJ, Ranawat CS (1979) Total hip replacement in congenital dislocation and dysplasia of the hip. J Bone Joint Surg Am 61:15–23PubMed
33.
Zurück zum Zitat Gruen TA, McNelce GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Rel Res 141:17–27 Gruen TA, McNelce GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Rel Res 141:17–27
34.
Zurück zum Zitat Engh CA, Bobyn JD, Glassman AH (1987) Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br 69:45–55PubMed Engh CA, Bobyn JD, Glassman AH (1987) Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br 69:45–55PubMed
35.
Zurück zum Zitat McCarthy CK, Steinberg GG, Agren M, Leahey D, Wyman E, Baran DT (1991) Quantifying bone loss from the proximal femur after total hip arthroplasty. J Bone Joint Surg Br 73:774–778PubMed McCarthy CK, Steinberg GG, Agren M, Leahey D, Wyman E, Baran DT (1991) Quantifying bone loss from the proximal femur after total hip arthroplasty. J Bone Joint Surg Br 73:774–778PubMed
36.
Zurück zum Zitat Huiskes R (1993) Stress shielding and bone resorption in THA: clinical versus computer-simulation studies. Acta Orthop Belg 59(Suppl 1):118–129PubMed Huiskes R (1993) Stress shielding and bone resorption in THA: clinical versus computer-simulation studies. Acta Orthop Belg 59(Suppl 1):118–129PubMed
37.
Zurück zum Zitat Bugbee WD, Culpepper WJ 2nd, Engh CA Jr, Engh CA Sr (1997) Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement. J Bone Joint Surg Am 79:1007–1012PubMed Bugbee WD, Culpepper WJ 2nd, Engh CA Jr, Engh CA Sr (1997) Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement. J Bone Joint Surg Am 79:1007–1012PubMed
38.
Zurück zum Zitat Knox D, Hamilton SW, Wardlaw D, Gibson PH (2009) Early catastrophic acetabular failure in Furlong total hip replacements. J Orthopaed Traumatol 10(1):39–42CrossRef Knox D, Hamilton SW, Wardlaw D, Gibson PH (2009) Early catastrophic acetabular failure in Furlong total hip replacements. J Orthopaed Traumatol 10(1):39–42CrossRef
39.
Zurück zum Zitat Engh CA, Hopper RH Jr (2002) The odyssey of porous-coated fixation. J Arthroplasty 17(4 Suppl 1):102–107PubMedCrossRef Engh CA, Hopper RH Jr (2002) The odyssey of porous-coated fixation. J Arthroplasty 17(4 Suppl 1):102–107PubMedCrossRef
40.
Zurück zum Zitat Engh CA Jr, Young AM, Engh CA Sr, Hopper RH Jr (2003) Clinical consequences of stress shielding after porous-coated total hip arthroplasty. Clin Orthop Relat Res 417:157–163PubMed Engh CA Jr, Young AM, Engh CA Sr, Hopper RH Jr (2003) Clinical consequences of stress shielding after porous-coated total hip arthroplasty. Clin Orthop Relat Res 417:157–163PubMed
41.
Zurück zum Zitat Goosen JH, Swieringa AJ, Keet JG, Verheyen CC (2005) Excellent results from proximally HA-coated femoral stems with a minimum of 6 years follow-up: a prospective evaluation of 100 patients. Acta Orthop 76:190–197PubMedCrossRef Goosen JH, Swieringa AJ, Keet JG, Verheyen CC (2005) Excellent results from proximally HA-coated femoral stems with a minimum of 6 years follow-up: a prospective evaluation of 100 patients. Acta Orthop 76:190–197PubMedCrossRef
42.
Zurück zum Zitat Pitto RP, Hayward A, Walker C, Shim VB (2010) Femoral bone density changes after total hip arthroplasty with uncemented taper-design stem: a five year follow-up study. Int Orthop 34:783–787PubMedCentralPubMedCrossRef Pitto RP, Hayward A, Walker C, Shim VB (2010) Femoral bone density changes after total hip arthroplasty with uncemented taper-design stem: a five year follow-up study. Int Orthop 34:783–787PubMedCentralPubMedCrossRef
43.
Zurück zum Zitat Furlong RJ, Osborn JF (1991) Fixation of hip prostheses by hydroxyapatite ceramic coatings. J Bone Joint Surg Br 73:741–745PubMed Furlong RJ, Osborn JF (1991) Fixation of hip prostheses by hydroxyapatite ceramic coatings. J Bone Joint Surg Br 73:741–745PubMed
44.
Zurück zum Zitat Vresilovic EJ, Hozack WJ, Rothman RH (1996) Incidence of thigh pain after uncemented total hip arthroplasty as a function of femoral stem size. J Arthroplasty 11:304–311PubMedCrossRef Vresilovic EJ, Hozack WJ, Rothman RH (1996) Incidence of thigh pain after uncemented total hip arthroplasty as a function of femoral stem size. J Arthroplasty 11:304–311PubMedCrossRef
45.
Zurück zum Zitat Wagner H, Wagner M (2000) Cone prosthesis for the hip joint. Arch Orthop Trauma Surg 120:88–95PubMed Wagner H, Wagner M (2000) Cone prosthesis for the hip joint. Arch Orthop Trauma Surg 120:88–95PubMed
Metadaten
Titel
Congenital hip dysplasia treated by total hip arthroplasty using cementless tapered stem in patients younger than 50 years old: results after 12-years follow-up
verfasst von
Cesare Faldini
Maria Teresa Miscione
Mohammadreza Chehrassan
Francesco Acri
Camilla Pungetti
Michele d’Amato
Deianira Luciani
Sandro Giannini
Publikationsdatum
01.12.2011
Verlag
Springer International Publishing
Erschienen in
Journal of Orthopaedics and Traumatology / Ausgabe 4/2011
Print ISSN: 1590-9921
Elektronische ISSN: 1590-9999
DOI
https://doi.org/10.1007/s10195-011-0170-y

Weitere Artikel der Ausgabe 4/2011

Journal of Orthopaedics and Traumatology 4/2011 Zur Ausgabe

Acknowledgement to Referees

2011 Scientific Referees

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Lever-Sign-Test hilft beim Verdacht auf Kreuzbandriss

15.05.2024 Vordere Kreuzbandruptur Nachrichten

Mit dem Hebelzeichen-Test lässt sich offenbar recht zuverlässig feststellen, ob ein vorderes Kreuzband gerissen ist. In einer Metaanalyse war die Vorhersagekraft vor allem bei positivem Testergebnis hoch.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.