Soft Copy Display Requirements for Digital Mammography

verfasst von: Bradley M. Hemminger Ph.D.

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 3/2003

Einloggen, um Zugang zu erhalten

Abstract

One of the advantages of digital mammography is to display mammograms on softcopy (electronic displays). Softcopy display of mammography is challenging because of the spatial and contrast resolution demands present in mammograms. We have designed and developed a softcopy mammography display application, Mammoview, which is capable of allowing radiologists to read mammograms as quickly and as accurately as they can on film alternators. We review the studies using Mammoview to elucidate the requirements of a successful softcopy display station. The design and development of the Mammoview softcopy display station are described in this article, and results of several studies using Mammoview are reported, including subjective feedback from Radiological Society of North America (RSNA) conference demonstrations, and clinical studies measuring performance in terms of speed and accuracy. Additional analysis of user interactions and user feedback is used to study the successes and shortcomings of mammography display stations like Mammoview. Overall, radiologist readings using Mammoview have been shown to be as fast and as accurate as readings using mammography film alternators. However, certain parts of the softcopy interface were more successful than their film counterparts, whereas others were less successful. Data analysis of the recorded human–computer interactions for the softcopy component of the clinical trial indicate statistically significant correlations between the difference in review time of softcopy versus alternator readings and three factors: the number of interactions, the reader, and the size of the image being reviewed. The first factor (number of interactions) suggests that simpler interfaces require less time to use; the second factor, the reader, supports previous findings that radiologists vary in how fast they read screening mammography studies; the third, size of image, suggests that the speed of softcopy review is increased relative to film readings when images are significantly larger than the display size. Feedback from radiologists using the system in clinical trials and at demonstration exhibits at RSNA indicated good acceptance of the interface and easy adaptation. Radiologists indicated that they felt comfortable using the interface, and that they would use such a softcopy interface in clinical practice. Finally, preliminary work suggests that the addition of a simple interaction to incorporate computer-aided detection (CAD) results would improve reading accuracy without significantly increasing reader times.
Literatur
1.
Zurück zum Zitat Baker, LH 1982Breast Cancer Detection Demonstration Project: five-year summary report.CA Cancer J Clin32194225PubMed Baker, LH 1982Breast Cancer Detection Demonstration Project: five-year summary report.CA Cancer J Clin32194225PubMed
2.
Zurück zum Zitat Beard, DV, Bream, P, Pisano, ED, et al. 1997A pilot study of eye movement during mammography interpretation: eyetracker results and workstation design implications.J Digit Imaging101420 Beard, DV, Bream, P, Pisano, ED,  et al. 1997A pilot study of eye movement during mammography interpretation: eyetracker results and workstation design implications.J Digit Imaging101420
3.
Zurück zum Zitat Beard, DV, Hemminger, BM, Perry, JR, et al. 1993Interpretation of CT studies: single-screen workstation versus film alternator.Radiology187565569PubMed Beard, DV, Hemminger, BM, Perry, JR,  et al. 1993Interpretation of CT studies: single-screen workstation versus film alternator.Radiology187565569PubMed
4.
Zurück zum Zitat Birdwell, RL, Ikeda, DM, O’Shaughnessy, KF, et al. 2001Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection.Radiology219192202PubMed Birdwell, RL, Ikeda, DM, O’Shaughnessy, KF,  et al. 2001Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection.Radiology219192202PubMed
5.
Zurück zum Zitat Chan, HP, Sahiner, B, Helvie, MA, et al. 1999Improvement of radiologists’ characterization of mammographic masses by using computer-aided diagnosis: an ROC study.Radiology212817827PubMed Chan, HP, Sahiner, B, Helvie, MA,  et al. 1999Improvement of radiologists’ characterization of mammographic masses by using computer-aided diagnosis: an ROC study.Radiology212817827PubMed
6.
Zurück zum Zitat Feig, SA, Yaffe, MJ 1996Current status of digital mammography.Semin Ultrasound CT MR17424443PubMed Feig, SA, Yaffe, MJ 1996Current status of digital mammography.Semin Ultrasound CT MR17424443PubMed
7.
Zurück zum Zitat Freer, TW, Ulissey, MJ 2001Screening mammography with computer-aided detection: prospective study of 12,860 patients in a community breast center.Radiology220781786PubMed Freer, TW, Ulissey, MJ 2001Screening mammography with computer-aided detection: prospective study of 12,860 patients in a community breast center.Radiology220781786PubMed
8.
Zurück zum Zitat Hemminger BM: Softcopy Display Requirements for Digital Mammography. Medical Imaging 2002: Visualization, Image-Guided Procedures, and Display 4681, 2002 Hemminger BM: Softcopy Display Requirements for Digital Mammography. Medical Imaging 2002: Visualization, Image-Guided Procedures, and Display 4681, 2002
9.
Zurück zum Zitat Hemminger, BM, Zong, S, Muller, KE, et al. 2001Improving the detection of simulated masses in mammograms through two different image-processing techniques.Acad Radiol8845855CrossRefPubMed Hemminger, BM, Zong, S, Muller, KE,  et al. 2001Improving the detection of simulated masses in mammograms through two different image-processing techniques.Acad Radiol8845855CrossRefPubMed
10.
Zurück zum Zitat Hollingsworth, AB, Taylor, LD, Rhodes, DC 1993Establishing a histologic basis for false-negative mammograms.Am J Surg166643648PubMed Hollingsworth, AB, Taylor, LD, Rhodes, DC 1993Establishing a histologic basis for false-negative mammograms.Am J Surg166643648PubMed
11.
Zurück zum Zitat Krupinski, E, Roehrig, H, Furukawa, T 1999Influence of film and monitor display luminance on observer performance and visual search.Acad Radiol6411448PubMed Krupinski, E, Roehrig, H, Furukawa, T 1999Influence of film and monitor display luminance on observer performance and visual search.Acad Radiol6411448PubMed
12.
Zurück zum Zitat Leichter, I, Fields, S, Nirel, R, et al. 2000Improved mammographic interpretation of masses using computer-aided diagnosis.Eur Radiol10377383CrossRefPubMed Leichter, I, Fields, S, Nirel, R,  et al. 2000Improved mammographic interpretation of masses using computer-aided diagnosis.Eur Radiol10377383CrossRefPubMed
13.
Zurück zum Zitat National Electrical Manufacturers Association2001Digital Imaging and Communications in Medicine (DICOM) International Standard. http://medical.nema.orgNational Electrical Manufacturers AssociationRosslyn, VA National Electrical Manufacturers Association2001Digital Imaging and Communications in Medicine (DICOM) International Standard. http://medical.nema.orgNational Electrical Manufacturers AssociationRosslyn, VA
14.
Zurück zum Zitat Pisano, ED, Chandramouli, J, Hemminger, BM, et al. 1997Does intensity windowing improve the detection of simulated calcifications in dense mammograms?J Digit Imaging107984,PubMed Pisano, ED, Chandramouli, J, Hemminger, BM,  et al. 1997Does intensity windowing improve the detection of simulated calcifications in dense mammograms?J Digit Imaging107984,PubMed
15.
Zurück zum Zitat Pisano, ED, Chandramouli, J, Hemminger, BM, et al. 1997The effect of intensity windowing on the detection of simulated masses embedded in dense portions of digitized mammograms in a laboratory setting.J Digit Imaging10174182PubMed Pisano, ED, Chandramouli, J, Hemminger, BM,  et al. 1997The effect of intensity windowing on the detection of simulated masses embedded in dense portions of digitized mammograms in a laboratory setting.J Digit Imaging10174182PubMed
16.
Zurück zum Zitat Pisano, ED, Cole, EB, Hemminger, BM, et al. 2000Image processing algorithms for digital mammography: a pictorial essay.Radiographics2014791491PubMed Pisano, ED, Cole, EB, Hemminger, BM,  et al. 2000Image processing algorithms for digital mammography: a pictorial essay.Radiographics2014791491PubMed
17.
Zurück zum Zitat Pisano, ED, Cole, EB, Kistner, EO, et al. 2002Interpretation of digital mammograms: comparison of speed and accuracy of soft-copy versus printed-film display.Radiology223483488PubMed Pisano, ED, Cole, EB, Kistner, EO,  et al. 2002Interpretation of digital mammograms: comparison of speed and accuracy of soft-copy versus printed-film display.Radiology223483488PubMed
18.
Zurück zum Zitat Pisano, ED, Cole, EB, Major, S, et al. 2000Radiologists’ preferences for digital mammographic display. The International Digital Mammography Development Group.Radiology216820830PubMed Pisano, ED, Cole, EB, Major, S,  et al. 2000Radiologists’ preferences for digital mammographic display. The International Digital Mammography Development Group.Radiology216820830PubMed
19.
Zurück zum Zitat Pisano, ED, Yaffe, M 1998Digital mammography.Breast Disease10127136 Pisano, ED, Yaffe, M 1998Digital mammography.Breast Disease10127136
20.
Zurück zum Zitat Pisano, ED, Zong, S, Hemminger, BM, et al. 1998Contrast limited adaptive histogram equalization image processing to improve the detection of simulated spiculations in dense mammograms.J Digit Imaging11193200PubMed Pisano, ED, Zong, S, Hemminger, BM,  et al. 1998Contrast limited adaptive histogram equalization image processing to improve the detection of simulated spiculations in dense mammograms.J Digit Imaging11193200PubMed
21.
Zurück zum Zitat Puff, DT, Cromartie, R, Pisano, ED 1992Evaluation and optimization of contrast enhancement methods for medical images.Proc SPIE: Visualization in Biomedical Computing Conference1808336346 Puff, DT, Cromartie, R, Pisano, ED 1992Evaluation and optimization of contrast enhancement methods for medical images.Proc SPIE: Visualization in Biomedical Computing Conference1808336346
22.
Zurück zum Zitat Puff, DT, Pisano, ED, Muller, KE, et al. 1994A method for determination of optimal image enhancement for the detection of mammographic abnormalities.J Digit Imaging7161171PubMed Puff, DT, Pisano, ED, Muller, KE,  et al. 1994A method for determination of optimal image enhancement for the detection of mammographic abnormalities.J Digit Imaging7161171PubMed
23.
Zurück zum Zitat Rosenman, J, Roe, CA, Cromartie, R, et al. 1993Portal film enhancement: technique and clinical utility.Int J Radiat Oncol Biol Phys25333338PubMed Rosenman, J, Roe, CA, Cromartie, R,  et al. 1993Portal film enhancement: technique and clinical utility.Int J Radiat Oncol Biol Phys25333338PubMed
24.
Zurück zum Zitat Shtern, F 1992Digital mammography and related technologies: a perspective from the National Cancer Institute.Radiology183629630PubMed Shtern, F 1992Digital mammography and related technologies: a perspective from the National Cancer Institute.Radiology183629630PubMed
25.
Zurück zum Zitat Shtern, F, Winfield, DW, Behlen, F, et al. 1999Report of Working Group on Digital Mammography: Digital Displays and Workstation Design.Academic Radiology6197218 Shtern, F, Winfield, DW, Behlen, F,  et al. 1999Report of Working Group on Digital Mammography: Digital Displays and Workstation Design.Academic Radiology6197218
26.
Zurück zum Zitat Weibrecht, M, Spekowius, G, Quadflieg, P, et al. 1997Image quality assessment of monochrome monitors for medical softcopy display.Proc SPIE3031232244 Weibrecht, M, Spekowius, G, Quadflieg, P,  et al. 1997Image quality assessment of monochrome monitors for medical softcopy display.Proc SPIE3031232244
Metadaten
Titel
Soft Copy Display Requirements for Digital Mammography
verfasst von
Bradley M. Hemminger Ph.D.
Publikationsdatum
01.12.2003
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 3/2003
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-003-1659-6

Weitere Artikel der Ausgabe 3/2003

Journal of Digital Imaging 3/2003 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.