Skip to main content
Erschienen in: Journal of Digital Imaging 2/2006

01.06.2006

A HIPAA-Compliant Architecture for Securing Clinical Images

verfasst von: Brent J. Liu, Zheng Zhou, H. K. Huang

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 2/2006

Einloggen, um Zugang zu erhalten

Abstract

The Health Insurance Portability and Accountability Act (HIPAA, instituted April 2003) Security Standards mandate health institutions to protect health information against unauthorized use or disclosure. One approach to addressing this mandate is by utilizing user access control and generating audit trails of the various authorized as well as unauthorized user access of health data. Although most current clinical image systems [e.g., picture archiving and communication system (PACS)] have components that generate log files for application debugging purposes, there is a lack of methodology to obtain and synthesize the pertinent data from the large volumes of log data generated by these multiple components within a PACS. We have designed a HIPAA-compliant architecture specifically for tracking and auditing the image workflow of clinical imaging systems such as PACS. As an initial first step, we developed HIPAA-compliant auditing system (H-CAS) based on parts of this HIPAA-compliant architecture. H-CAS was implemented within a test-bed PACS simulator located in the Image Processing and Informatics lab at the University of Southern California. Evaluation scenarios were developed where different user types performed legal and illegal access of PACS image data within each of the different components in the PACS simulator. Results were based on whether the scenarios of unauthorized access were correctly identified and documented as well as on normal operational activity. Integration and implementation pitfalls were also noted and included.
Literatur
4.
Zurück zum Zitat Cao, F, Huang, HK, Zhou, XQ 2003Medical image security in a HIPAA mandated PACS environmentComput Med Imaging Graph27185196PubMedCrossRef Cao, F, Huang, HK, Zhou, XQ 2003Medical image security in a HIPAA mandated PACS environmentComput Med Imaging Graph27185196PubMedCrossRef
8.
Zurück zum Zitat Huang HK: PACS: Basic Principles and Applications. Wiley-Liss, p. 291, 1999 Huang HK: PACS: Basic Principles and Applications. Wiley-Liss, p. 291, 1999
9.
Zurück zum Zitat Zhou Z: Lossless Digital Signature Embedding for Medical Image Integrity Assurance, Ph.D. Dissertation, Chap. 5–6, July 2005 Zhou Z: Lossless Digital Signature Embedding for Medical Image Integrity Assurance, Ph.D. Dissertation, Chap. 5–6, July 2005
10.
Zurück zum Zitat Zhou, Z, Huang, HK, Liu, B 2005Digital signature embedding for medical image integrity in a data grid off-site backup archiveSPIE Med Imaging6306317 Zhou, Z, Huang, HK, Liu, B 2005Digital signature embedding for medical image integrity in a data grid off-site backup archiveSPIE Med Imaging6306317
12.
Zurück zum Zitat White, GB, Fisch, EA, Pooch, UW 1996Computer System and Network SecurityCRC PressBoca Raton, FL White, GB, Fisch, EA, Pooch, UW 1996Computer System and Network SecurityCRC PressBoca Raton, FL
13.
Zurück zum Zitat Law, MYY, Zhou, Z 2003New direction in PACS education and trainingComput Med Imaging Graph27147156PubMedCrossRef Law, MYY, Zhou, Z 2003New direction in PACS education and trainingComput Med Imaging Graph27147156PubMedCrossRef
14.
Zurück zum Zitat Zhou, Z, Huang, HK, Cao, F, Liu, BJ, Zhang, J, Mogel, GT 2003Educational RIS/PACS simulatorSPIE Med Imaging4139147 Zhou, Z, Huang, HK, Cao, F, Liu, BJ, Zhang, J, Mogel, GT 2003Educational RIS/PACS simulatorSPIE Med Imaging4139147
Metadaten
Titel
A HIPAA-Compliant Architecture for Securing Clinical Images
verfasst von
Brent J. Liu
Zheng Zhou
H. K. Huang
Publikationsdatum
01.06.2006
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 2/2006
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-005-9248-5

Weitere Artikel der Ausgabe 2/2006

Journal of Digital Imaging 2/2006 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.