Abstract

Thin-slice CT data, useful for clinical diagnosis and research, is now widely available but is typically discarded in many institutions, after a short period of time due to data storage capacity limitations. We designed and built a low-cost high-capacity Digital Imaging and COmmunication in Medicine (DICOM) storage system able to store thin-slice image data for years, using off-the-shelf consumer hardware components, such as a Macintosh computer, a Windows PC, and network-attached storage units. “Ordinary” hierarchical file systems, instead of a centralized data management system such as relational database, were adopted to manage patient DICOM files by arranging them in directories enabling quick and easy access to the DICOM files of each study by following the directory trees with Windows Explorer via study date and patient ID. Software used for this system was open-source OsiriX and additional programs we developed ourselves, both of which were freely available via the Internet. The initial cost of this system was about $3,600 with an incremental storage cost of about $900 per 1 terabyte (TB). This system has been running since 7th Feb 2008 with the data stored increasing at the rate of about 1.3 TB per month. Total data stored was 21.3 TB on 23rd June 2009. The maintenance workload was found to be about 30 to 60 min once every 2 weeks. In conclusion, this newly developed DICOM storage system is useful for research due to its cost-effectiveness, enormous capacity, high scalability, sufficient reliability, and easy data access.
Literatur
1.
Zurück zum Zitat Meenman C, Daly B, Toland C, Nagy P: Use of a thin-section archive and enterprise 3D software for long-term storage of thin-slice CT data sets. J Digit Imaging 19(suppl 1):84–88, 2006CrossRef Meenman C, Daly B, Toland C, Nagy P: Use of a thin-section archive and enterprise 3D software for long-term storage of thin-slice CT data sets. J Digit Imaging 19(suppl 1):84–88, 2006CrossRef
2.
Zurück zum Zitat Ooijen P, Broekema A, Oudkerk M: Use of a thin-section archive and enterprise 3D software for long-term storage of thin-slice CT data sets — A Reviewers’ Response. J Digit Imaging 21(2):188–192, 2008PubMedCrossRef Ooijen P, Broekema A, Oudkerk M: Use of a thin-section archive and enterprise 3D software for long-term storage of thin-slice CT data sets — A Reviewers’ Response. J Digit Imaging 21(2):188–192, 2008PubMedCrossRef
3.
Zurück zum Zitat Voellmy DR, Handgratinger O, Wildermuth S, Frohlich B,Marincek B: Total cost of high volume multi-detector CT data management. Computer Assisted Radiology and Surgery (CARS) 2004. Int Congr Ser 1268:249Y253, 2004CrossRef Voellmy DR, Handgratinger O, Wildermuth S, Frohlich B,Marincek B: Total cost of high volume multi-detector CT data management. Computer Assisted Radiology and Surgery (CARS) 2004. Int Congr Ser 1268:249Y253, 2004CrossRef
5.
Zurück zum Zitat Rosset A, Spadola L, Ratib O: OsiriX: An open-source software for navigating in multidimensional DICOM images. J Digit Imaging 17(3):205–216, 2004PubMedCrossRef Rosset A, Spadola L, Ratib O: OsiriX: An open-source software for navigating in multidimensional DICOM images. J Digit Imaging 17(3):205–216, 2004PubMedCrossRef
Metadaten
Titel
Development and Evaluation of a Low-Cost and High-Capacity DICOM Image Data Storage System for Research
verfasst von
Masahiro Yakami
Koichi Ishizu
Takeshi Kubo
Tomohisa Okada
Kaori Togashi
Publikationsdatum
01.04.2011
Verlag
Springer-Verlag
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 2/2011
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-009-9267-8

Weitere Artikel der Ausgabe 2/2011

Journal of Digital Imaging 2/2011 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.