Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 6/2016

19.02.2016 | Original Paper

Highly accelerated cardiac MRI using iterative SENSE reconstruction: initial clinical experience

verfasst von: Bradley D. Allen, Maria Carr, Marcos P. F. Botelho, Amir Ali Rahsepar, Michael Markl, Michael O. Zenge, Michaela Schmidt, Mariappan S. Nadar, Bruce Spottiswoode, Jeremy D. Collins, James C. Carr

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 6/2016

Einloggen, um Zugang zu erhalten

Abstract

To evaluate the qualitative and quantitative performance of an accelerated cardiovascular MRI (CMR) protocol that features iterative SENSE reconstruction and spatio-temporal L1-regularization (IS SENSE). Twenty consecutively recruited patients and 9 healthy volunteers were included. 2D steady state free precession cine images including 3-chamber, 4-chamber, and short axis slices were acquired using standard parallel imaging (GRAPPA, acceleration factor = 2), spatio-temporal undersampled TSENSE (acceleration factor = 4), and IS SENSE techniques (acceleration factor = 4). Acquisition times, quantitative cardiac functional parameters, wall motion abnormalities (WMA), and qualitative performance (scale: 1-poor to 5-excellent for overall image quality, noise, and artifact) were compared. Breath-hold times for IS SENSE (3.0 ± 0.6 s) and TSENSE (3.3 ± 0.6) were both reduced relative to GRAPPA (8.4 ± 1.7 s, p < 0.001). No difference in quantitative cardiac function was present between the three techniques (p = 0.89 for ejection fraction). GRAPPA and IS SENSE had similar image quality (4.7 ± 0.4 vs. 4.5 ± 0.6, p = 0.09) while, both techniques were superior to TSENSE (quality: 4.1 ± 0.7, p < 0.001). GRAPPA WMA agreement with IS SENSE was good (κ > 0.60, p < 0.001), while agreement with TSENSE was poor (κ < 0.40, p < 0.001). IS SENSE is a viable clinical CMR acceleration approach to reduce acquisition times while maintaining satisfactory qualitative and quantitative performance.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Grothues F, Smith GC, Moon JC, Bellenger NG, Collins P, Klein HU, Pennell DJ (2002) Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. Am J Cardiol 90(1):29–34CrossRefPubMed Grothues F, Smith GC, Moon JC, Bellenger NG, Collins P, Klein HU, Pennell DJ (2002) Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. Am J Cardiol 90(1):29–34CrossRefPubMed
2.
Zurück zum Zitat Chuang ML, Hibberd MG, Salton CJ, Beaudin RA, Riley MF, Parker RA, Douglas PS, Manning WJ (2000) Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fraction: assessment by two- and three-dimensional echocardiography and magnetic resonance imaging. J Am Coll Cardiol 35(2):477–484CrossRefPubMed Chuang ML, Hibberd MG, Salton CJ, Beaudin RA, Riley MF, Parker RA, Douglas PS, Manning WJ (2000) Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fraction: assessment by two- and three-dimensional echocardiography and magnetic resonance imaging. J Am Coll Cardiol 35(2):477–484CrossRefPubMed
3.
Zurück zum Zitat Scharf M, Brem MH, Wilhelm M, Schoepf UJ, Uder M, Lell MM (2010) Atrial and ventricular functional and structural adaptations of the heart in elite triathletes assessed with cardiac MR imaging. Radiology 257(1):71–79CrossRefPubMed Scharf M, Brem MH, Wilhelm M, Schoepf UJ, Uder M, Lell MM (2010) Atrial and ventricular functional and structural adaptations of the heart in elite triathletes assessed with cardiac MR imaging. Radiology 257(1):71–79CrossRefPubMed
6.
Zurück zum Zitat Wang Y, Grimm RC, Rossman PJ, Debbins JP, Riederer SJ, Ehman RL (1995) 3D coronary MR angiography in multiple breath-holds using a respiratory feedback monitor. Magn Reson Med 34(1):11–16CrossRefPubMed Wang Y, Grimm RC, Rossman PJ, Debbins JP, Riederer SJ, Ehman RL (1995) 3D coronary MR angiography in multiple breath-holds using a respiratory feedback monitor. Magn Reson Med 34(1):11–16CrossRefPubMed
7.
Zurück zum Zitat Slomka PJ, Fieno D, Ramesh A, Goyal V, Nishina H, Thompson LE, Saouaf R, Berman DS, Germano G (2007) Patient motion correction for multiplanar, multi-breath-hold cardiac cine MR imaging. J Magn Reson Imaging 25(5):965–973. doi:10.1002/jmri.20909 CrossRefPubMed Slomka PJ, Fieno D, Ramesh A, Goyal V, Nishina H, Thompson LE, Saouaf R, Berman DS, Germano G (2007) Patient motion correction for multiplanar, multi-breath-hold cardiac cine MR imaging. J Magn Reson Imaging 25(5):965–973. doi:10.​1002/​jmri.​20909 CrossRefPubMed
10.
Zurück zum Zitat Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P (1999) SENSE: sensitivity encoding for fast MRI. Magn Reson Med 42(5):952–962CrossRefPubMed Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P (1999) SENSE: sensitivity encoding for fast MRI. Magn Reson Med 42(5):952–962CrossRefPubMed
11.
Zurück zum Zitat Griswold MA, Jakob PM, Heidemann RM, Nittka M, Jellus V, Wang J, Kiefer B, Haase A (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47(6):1202–1210. doi:10.1002/mrm.10171 CrossRefPubMed Griswold MA, Jakob PM, Heidemann RM, Nittka M, Jellus V, Wang J, Kiefer B, Haase A (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47(6):1202–1210. doi:10.​1002/​mrm.​10171 CrossRefPubMed
12.
Zurück zum Zitat Kellman P, Epstein FH, McVeigh ER (2001) Adaptive sensitivity encoding incorporating temporal filtering (TSENSE). Magn Reson Med 45(5):846–852CrossRefPubMed Kellman P, Epstein FH, McVeigh ER (2001) Adaptive sensitivity encoding incorporating temporal filtering (TSENSE). Magn Reson Med 45(5):846–852CrossRefPubMed
14.
Zurück zum Zitat Tsao J, Boesiger P, Pruessmann KP (2003) k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 50(5):1031–1042CrossRefPubMed Tsao J, Boesiger P, Pruessmann KP (2003) k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 50(5):1031–1042CrossRefPubMed
19.
Zurück zum Zitat Kannengiesser SAR, Brenner A, Noll TG (2000) Accelerated image reconstruction for sensitivity encoded imaging with arbitrary k–space trajectories. In: Proceedings of 8th annual meeting of ISMRM, Denver, p 155 Kannengiesser SAR, Brenner A, Noll TG (2000) Accelerated image reconstruction for sensitivity encoded imaging with arbitrary k–space trajectories. In: Proceedings of 8th annual meeting of ISMRM, Denver, p 155
20.
Zurück zum Zitat Liu J, Rapin J, Chang T-C, Lefebvre A, Zenge M, Mueller E, Nadar MS (2012) Dynamic cardiac MRI reconstruction with weighted redundant Haar wavelets. In: ISMRM 20th annual meeting, Melbourne, Australia, p 4249 Liu J, Rapin J, Chang T-C, Lefebvre A, Zenge M, Mueller E, Nadar MS (2012) Dynamic cardiac MRI reconstruction with weighted redundant Haar wavelets. In: ISMRM 20th annual meeting, Melbourne, Australia, p 4249
21.
Zurück zum Zitat Kaji S, Yang PC, Kerr AB, Tang WH, Meyer CH, Macovski A, Pauly JM, Nishimura DG, Hu BS (2001) Rapid evaluation of left ventricular volume and mass without breath-holding using real-time interactive cardiac magnetic resonance imaging system. J Am Coll Cardiol 38(2):527–533CrossRefPubMed Kaji S, Yang PC, Kerr AB, Tang WH, Meyer CH, Macovski A, Pauly JM, Nishimura DG, Hu BS (2001) Rapid evaluation of left ventricular volume and mass without breath-holding using real-time interactive cardiac magnetic resonance imaging system. J Am Coll Cardiol 38(2):527–533CrossRefPubMed
22.
Zurück zum Zitat Schnell S, Markl M, Entezari P, Mahadewia RJ, Semaan E, Stankovic Z, Collins J, Carr J, Jung B (2013) k-t GRAPPA accelerated four-dimensional flow MRI in the aorta: effect on scan time, image quality, and quantification of flow and wall shear stress. Magn Reson Med. doi:10.1002/mrm.24925 PubMedPubMedCentral Schnell S, Markl M, Entezari P, Mahadewia RJ, Semaan E, Stankovic Z, Collins J, Carr J, Jung B (2013) k-t GRAPPA accelerated four-dimensional flow MRI in the aorta: effect on scan time, image quality, and quantification of flow and wall shear stress. Magn Reson Med. doi:10.​1002/​mrm.​24925 PubMedPubMedCentral
23.
24.
Zurück zum Zitat Gabriel RS, Kerr AJ, Raffel OC, Stewart RA, Cowan BR, Occleshaw CJ (2008) Mapping of mitral regurgitant defects by cardiovascular magnetic resonance in moderate or severe mitral regurgitation secondary to mitral valve prolapse. J Cardiovasc Magn Reson 10:16. doi:10.1186/1532-429x-10-16 CrossRefPubMedPubMedCentral Gabriel RS, Kerr AJ, Raffel OC, Stewart RA, Cowan BR, Occleshaw CJ (2008) Mapping of mitral regurgitant defects by cardiovascular magnetic resonance in moderate or severe mitral regurgitation secondary to mitral valve prolapse. J Cardiovasc Magn Reson 10:16. doi:10.​1186/​1532-429x-10-16 CrossRefPubMedPubMedCentral
Metadaten
Titel
Highly accelerated cardiac MRI using iterative SENSE reconstruction: initial clinical experience
verfasst von
Bradley D. Allen
Maria Carr
Marcos P. F. Botelho
Amir Ali Rahsepar
Michael Markl
Michael O. Zenge
Michaela Schmidt
Mariappan S. Nadar
Bruce Spottiswoode
Jeremy D. Collins
James C. Carr
Publikationsdatum
19.02.2016
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 6/2016
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-016-0859-3

Weitere Artikel der Ausgabe 6/2016

The International Journal of Cardiovascular Imaging 6/2016 Zur Ausgabe

Schadet Ärger den Gefäßen?

14.05.2024 Arteriosklerose Nachrichten

In einer Studie aus New York wirkte sich Ärger kurzfristig deutlich negativ auf die Endothelfunktion gesunder Probanden aus. Möglicherweise hat dies Einfluss auf die kardiovaskuläre Gesundheit.

Intervallfasten zur Regeneration des Herzmuskels?

14.05.2024 Herzinfarkt Nachrichten

Die Nahrungsaufnahme auf wenige Stunden am Tag zu beschränken, hat möglicherweise einen günstigen Einfluss auf die Prognose nach akutem ST-Hebungsinfarkt. Darauf deutet eine Studie an der Uniklinik in Halle an der Saale hin.

Shunt-Therapie bei Herzinsuffizienz: Kein Anzug, der allen passt

13.05.2024 Chronische Herzinsuffizienz Nachrichten

Die Anlage eines interatrialen Shunts zur Reduktion des linksatrialen Drucks ist ein neuer Therapieansatz bei Herzinsuffizienz. Viele Patienten sprechen darauf an, andere jedoch nicht. 

Vorsicht, erhöhte Blutungsgefahr nach PCI!

10.05.2024 Koronare Herzerkrankung Nachrichten

Nach PCI besteht ein erhöhtes Blutungsrisiko, wenn die Behandelten eine verminderte linksventrikuläre Ejektionsfraktion aufweisen. Das Risiko ist umso höher, je stärker die Pumpfunktion eingeschränkt ist.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.