Purpose

Acuity-VEP approaches basically all use the information obtained across a number of check sizes (or spatial frequencies) to derive a measure of acuity. Amplitude is always used, sometimes combined with phase or a noise measure. In our approach, we employ steady-state brief-onset low-contrast checkerboard stimulation and obtain amplitude and significance for six different check sizes, yielding 12 numbers. The rule-based “heuristic algorithm” (Bach et al. in Br J Ophthalmol 92:396–403, 2008. https://​doi.​org/​10.​1136/​bjo.​2007.​130245) is successful in over 95% with a limit of agreement (LoA) of ± 0.3LogMAR between behavioral and objective acuity for 109 cases. We here aimed to test whether machine learning techniques with this relatively small dataset could achieve a similar LoA.

Methods

Given recent advances in machine learning (ML), we applied a wide class of ML algorithms to this dataset. This was done within the “caret” framework of R using altogether 89 methods, of which rule-based and multiple regression approaches performed best. For cross-validation, using a jackknife (leave-one-out) approach, we predicted each case based on an ML model having been trained on all remaining 108 cases.

Results

The ML approach predicted visual acuity well across many different types of ML algorithms. Using amplitude values only (discarding the p values) improved the outcome. Nearly half of the tested ML algorithms achieved an LoA better than the heuristic algorithm; several “Random Forest”- or “multiple regression”-type algorithms achieved an LoA of below ± 0.3. In the cases where the heuristic approach failed, acuity was predicted successfully. We then applied the ML model trained with the Bach et al. [1] dataset to a new dataset from 2018 (78 cases) and found both for the heuristic algorithm and for the ML approach an LoA of ± 0.259, a nearly one-line improvement.

Conclusions

The ML approach appears to be a useful alternative to rule-based analysis of acuity-VEP data. The achieved accuracy is comparable or better (in no case the ML-based acuity differed more than ± 0.29 LogMAR from behavioral acuity), and testability is higher, nearly 100%. Possible pitfalls are examined.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
2.
Zurück zum Zitat Strasburger H, Scheidler W, Rentschler I (1988) Amplitude and phase characteristics of the steady-state visual evoked potential. Appl Opt 27:1069–1088CrossRefPubMed Strasburger H, Scheidler W, Rentschler I (1988) Amplitude and phase characteristics of the steady-state visual evoked potential. Appl Opt 27:1069–1088CrossRefPubMed
3.
Zurück zum Zitat Joost W, Bach M (1990) Variability of the steady-state visually evoked potential: interindividual variance and intraindividual reproducibility of spatial frequency tuning. Doc Ophthalmol 75:59–66CrossRefPubMed Joost W, Bach M (1990) Variability of the steady-state visually evoked potential: interindividual variance and intraindividual reproducibility of spatial frequency tuning. Doc Ophthalmol 75:59–66CrossRefPubMed
4.
Zurück zum Zitat Bach M, Meigen T (1999) Do’s and don’ts in Fourier analysis of steady-state potentials. Doc Ophthalmol 99:69–82CrossRefPubMed Bach M, Meigen T (1999) Do’s and don’ts in Fourier analysis of steady-state potentials. Doc Ophthalmol 99:69–82CrossRefPubMed
5.
Zurück zum Zitat Meigen T, Bach M (1999) On the statistical significance of electrophysiological steady-state responses. Doc Ophthalmol 98:207–232CrossRefPubMed Meigen T, Bach M (1999) On the statistical significance of electrophysiological steady-state responses. Doc Ophthalmol 98:207–232CrossRefPubMed
8.
Zurück zum Zitat Kuhn M (2018) caret (Classification and Regression Training) R package that contains misc functions for training and plotting classification and regression models: topepo/caret. https://github.com/topepo/caret. Accessed 21 Oct 2018 Kuhn M (2018) caret (Classification and Regression Training) R package that contains misc functions for training and plotting classification and regression models: topepo/caret. https://​github.​com/​topepo/​caret. Accessed 21 Oct 2018
15.
Zurück zum Zitat Kushner BJ, Lucchese NJ, Morton GV (1995) Grating visual acuity with Teller cards compared with Snellen visual acuity in literate patients. Arch Ophthalmol 113:485–493CrossRefPubMed Kushner BJ, Lucchese NJ, Morton GV (1995) Grating visual acuity with Teller cards compared with Snellen visual acuity in literate patients. Arch Ophthalmol 113:485–493CrossRefPubMed
Metadaten
Titel
Acuity VEP: improved with machine learning
verfasst von
Michael Bach
Sven P. Heinrich
Publikationsdatum
11.06.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
Documenta Ophthalmologica / Ausgabe 2/2019
Print ISSN: 0012-4486
Elektronische ISSN: 1573-2622
DOI
https://doi.org/10.1007/s10633-019-09701-x

Weitere Artikel der Ausgabe 2/2019

Documenta Ophthalmologica 2/2019 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Ophthalmika in der Schwangerschaft

Die Verwendung von Ophthalmika in der Schwangerschaft und Stillzeit stellt immer eine Off-label-Anwendung dar. Ein Einsatz von Arzneimitteln muss daher besonders sorgfältig auf sein Risiko-Nutzen-Verhältnis bewertet werden. In der vorliegenden …

Operative Therapie und Keimnachweis bei endogener Endophthalmitis

Vitrektomie Originalie

Die endogene Endophthalmitis ist eine hämatogen fortgeleitete, bakterielle oder fungale Infektion, die über choroidale oder retinale Gefäße in den Augapfel eingeschwemmt wird [ 1 – 3 ]. Von dort infiltrieren die Keime in die Netzhaut, den …

Bakterielle endogene Endophthalmitis

Vitrektomie Leitthema

Eine endogene Endophthalmitis stellt einen ophthalmologischen Notfall dar, der umgehender Diagnostik und Therapie bedarf. Es sollte mit geeigneten Methoden, wie beispielsweise dem Freiburger Endophthalmitis-Set, ein Keimnachweis erfolgen. Bei der …

So erreichen Sie eine bestmögliche Wundheilung der Kornea

Die bestmögliche Wundheilung der Kornea, insbesondere ohne die Ausbildung von lichtstreuenden Narben, ist oberstes Gebot, um einer dauerhaften Schädigung der Hornhaut frühzeitig entgegenzuwirken und die Funktion des Auges zu erhalten.   

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.