Purpose   

Wireless capsule endoscopy (WCE) is commonly used for noninvasive gastrointestinal tract evaluation, including the detection of mucosal polyps. A new embeddable method for polyp detection in wireless capsule endoscopic images was developed and tested.

Methods   

First, possible polyps within the image were extracted using geometric shape features. Next, the candidate regions of interest were evaluated with a boosting based method using textural features. Each step was carefully chosen to accommodate hardware implementation constraints. The method’s performance was evaluated on WCE datasets including 300 images with polyps and 1,200 images without polyps. Hardware implementation of the proposed approach was evaluated to quantitatively demonstrate the feasibility of such integration into the WCE itself.

Results   

The boosting based polyp classification demonstrated a sensitivity of 91.0 %, a specificity of 95.2 % and a false detection rate of 4.8 %. This performance is close to that reported recently in systems developed for an online analysis of video colonoscopy images.

Conclusion   

A new method for polyp detection in videoendoscopic WCE examinations was developed using boosting based approach. This method achieved good classification performance and can be implemented in situ with embedded hardware.
Literatur
1.
Zurück zum Zitat Parkin MC, Shin FJ, Forman BF (2008) Globocan 2008 v1.2, cancer incidence and mortality worldwide: Iarc cancerbase no. 10. International Agency for Research on Cancer Parkin MC, Shin FJ, Forman BF (2008) Globocan 2008 v1.2, cancer incidence and mortality worldwide: Iarc cancerbase no. 10. International Agency for Research on Cancer
2.
Zurück zum Zitat Moglia A, Menciassi A, Dario A, Cuschieri A (2009) Capsule endoscopy: progress update and challenges ahead. Nat Rev Gastroenterol Hepatol (6):352–362 Moglia A, Menciassi A, Dario A, Cuschieri A (2009) Capsule endoscopy: progress update and challenges ahead. Nat Rev Gastroenterol Hepatol (6):352–362
3.
Zurück zum Zitat Spada C, Hassan C, Munoz-Navas M, Sacher-Huvelin S, Delvaux M et al (2011) Second-generation colon capsule endoscopy compared with colonoscopy. Gastrointest Endosc 74(3):581–589 Spada C, Hassan C, Munoz-Navas M, Sacher-Huvelin S, Delvaux M et al (2011) Second-generation colon capsule endoscopy compared with colonoscopy. Gastrointest Endosc 74(3):581–589
4.
Zurück zum Zitat Bergwerk A, Fleischer D, Gerber J (2007) A capsule endoscopy guide for the practising clinician: technology and troubleshooting. Medline 66(6):1188–1195 Bergwerk A, Fleischer D, Gerber J (2007) A capsule endoscopy guide for the practising clinician: technology and troubleshooting. Medline 66(6):1188–1195
5.
Zurück zum Zitat Eliakim R et al (2009) Prospective multi center performance evaluation of the second generation colon capsule compared with colonoscopy. Endoscopy 41:1026–1031PubMedCrossRef Eliakim R et al (2009) Prospective multi center performance evaluation of the second generation colon capsule compared with colonoscopy. Endoscopy 41:1026–1031PubMedCrossRef
6.
Zurück zum Zitat Kolar A, Romain O, Ayoub J, Viateur S, Granado B (2010) Prototype of video endoscopic capsule With 3-D imaging capabilities. IEEE Trans Biomed Circuits Syst 4(4):239–249PubMedCrossRef Kolar A, Romain O, Ayoub J, Viateur S, Granado B (2010) Prototype of video endoscopic capsule With 3-D imaging capabilities. IEEE Trans Biomed Circuits Syst 4(4):239–249PubMedCrossRef
7.
Zurück zum Zitat Ayoub J, Granado B, Mhanna Y, Romain O (2010) SVM based colon polyps classifier in a wireless active stereo endoscope. In: 2010 IEEE EMBC, pp 5585–5588 Ayoub J, Granado B, Mhanna Y, Romain O (2010) SVM based colon polyps classifier in a wireless active stereo endoscope. In: 2010 IEEE EMBC, pp 5585–5588
8.
Zurück zum Zitat Liu M, Lu L, Bi J, Raykar V, Wolf M, Salganicoff M, (2011) Robust large scale prone-supine polyp matching using local features: a metric learning approach. In: Fichtinger G, Martel A, Peters T (eds) Medical image computing and computer-assisted intervention MICCAI 2011, vol. 6893 of Lecture Notes in Computer Science. Springer, Berlin, pp 75–82 Liu M, Lu L, Bi J, Raykar V, Wolf M, Salganicoff M, (2011) Robust large scale prone-supine polyp matching using local features: a metric learning approach. In: Fichtinger G, Martel A, Peters T (eds) Medical image computing and computer-assisted intervention MICCAI 2011, vol. 6893 of Lecture Notes in Computer Science. Springer, Berlin, pp 75–82
9.
Zurück zum Zitat Bernal J, Sanchez J, Vilariño F (2012) Towards automatic polyp detection with a polyp appearance model. Pattern Recogn 45(9):3166–3182CrossRef Bernal J, Sanchez J, Vilariño F (2012) Towards automatic polyp detection with a polyp appearance model. Pattern Recogn 45(9):3166–3182CrossRef
10.
Zurück zum Zitat Figueiredo PN, Figueiredo IN, Prasath S, Tsai R (2011) Automatic polyp detection in pillcam colon 2 capsule images and videos: preliminary feasibility report. Diagn Ther Endosc. doi:10.1155/2011/182435 Figueiredo PN, Figueiredo IN, Prasath S, Tsai R (2011) Automatic polyp detection in pillcam colon 2 capsule images and videos: preliminary feasibility report. Diagn Ther Endosc. doi:10.​1155/​2011/​182435
11.
Zurück zum Zitat Karargyris A, Bourbakis N (2009) Identification of polyps in wireless capsule endoscopy videos using log gabor filters. In: IEEE workshop LiSSA, pp 143–147 Karargyris A, Bourbakis N (2009) Identification of polyps in wireless capsule endoscopy videos using log gabor filters. In: IEEE workshop LiSSA, pp 143–147
12.
Zurück zum Zitat Kodogiannis V, Boulougoura M (2007) An adaptive neurofuzzy approach for the diagnosis in wireless capsule endoscopy imaging. Int J Inf Technol 13:46–56 Kodogiannis V, Boulougoura M (2007) An adaptive neurofuzzy approach for the diagnosis in wireless capsule endoscopy imaging. Int J Inf Technol 13:46–56
13.
Zurück zum Zitat Tagzout S, Achour K, Djekoune O (2001) Hough transform algorithm for fpga implementation. Signal Process 81(6):1295–1301CrossRef Tagzout S, Achour K, Djekoune O (2001) Hough transform algorithm for fpga implementation. Signal Process 81(6):1295–1301CrossRef
14.
Zurück zum Zitat Davis LS, Johns SA, Aggarwal JK (1979) Texture analysis using generalized co-occurrence matrices. IEEE Trans Pattern Anal Mach Intell PAMI–1(3):251–259CrossRef Davis LS, Johns SA, Aggarwal JK (1979) Texture analysis using generalized co-occurrence matrices. IEEE Trans Pattern Anal Mach Intell PAMI–1(3):251–259CrossRef
15.
Zurück zum Zitat Haralick RM (1979) Statistical and structural approaches to texture. Proc IEEE 67(5):786–804CrossRef Haralick RM (1979) Statistical and structural approaches to texture. Proc IEEE 67(5):786–804CrossRef
16.
Zurück zum Zitat Iakovidis DK, Maroulis DE, Bariamis DG (2007) Fpga architecture for fast parallel computation of co-occurrence matrices. Microprocess Microsyst 31(2):160–165CrossRef Iakovidis DK, Maroulis DE, Bariamis DG (2007) Fpga architecture for fast parallel computation of co-occurrence matrices. Microprocess Microsyst 31(2):160–165CrossRef
17.
Zurück zum Zitat Schapire RE, Singer Y (1999) Improved boosting algorithms using confidence-rated predictions. Mach Learn 37(3):297–336CrossRef Schapire RE, Singer Y (1999) Improved boosting algorithms using confidence-rated predictions. Mach Learn 37(3):297–336CrossRef
18.
Zurück zum Zitat Viola S, Jones M (2001) Rapid object detection using a boosted cascade of simple features. In: Proceedings of the 2001 IEEE CVPR conference, pp 511–518 Viola S, Jones M (2001) Rapid object detection using a boosted cascade of simple features. In: Proceedings of the 2001 IEEE CVPR conference, pp 511–518
19.
Zurück zum Zitat Kohonen T (1995) The handbook of brain theory and neural networks, chapter learning vector quantization. MIT Press, Cambridge Kohonen T (1995) The handbook of brain theory and neural networks, chapter learning vector quantization. MIT Press, Cambridge
20.
Zurück zum Zitat Liu M, Lu L, Ye X, Yu S, Salganicoff M (2011) Sparse classification for computer aided diagnosis using learned dictionaries. In: Fichtinger G, Martel A, Peters T (eds) Medical image computing and computer-assisted intervention MICCAI 2011, vol 6893 of Lecture Notes in Computer Science. Springer, Berlin, pp 41–48 Liu M, Lu L, Ye X, Yu S, Salganicoff M (2011) Sparse classification for computer aided diagnosis using learned dictionaries. In: Fichtinger G, Martel A, Peters T (eds) Medical image computing and computer-assisted intervention MICCAI 2011, vol 6893 of Lecture Notes in Computer Science. Springer, Berlin, pp 41–48
21.
Zurück zum Zitat Elhossini A, Moussa M (2012) Memory efficient fpga implementation of Hough transform for line and circle detection. In: CCECE, pp 1–5 Elhossini A, Moussa M (2012) Memory efficient fpga implementation of Hough transform for line and circle detection. In: CCECE, pp 1–5
22.
Zurück zum Zitat Ruen JJ, Shie MS, Chen C (2006) A circular hough transform hardware for industrial circle detection applications. In: Industrial Electronics and Applications, 2006 1st IEEE conference, pp 1–6 Ruen JJ, Shie MS, Chen C (2006) A circular hough transform hardware for industrial circle detection applications. In: Industrial Electronics and Applications, 2006 1st IEEE conference, pp 1–6
23.
Zurück zum Zitat Souki MA, Boussaid L, Abid M (2008) An embedded system for real-time traffic sign recognizing. In: Proceedings—2008 3rd international design and test workshop, IDT 2008, pp 273–276 Souki MA, Boussaid L, Abid M (2008) An embedded system for real-time traffic sign recognizing. In: Proceedings—2008 3rd international design and test workshop, IDT 2008, pp 273–276
24.
Zurück zum Zitat Geninatti SR, Benavidez-Benitez SR, Hernandez-Calvino M, Guil-Mata N, Gomez-Luna J Fpga implementation of the generalized hough transform. In: Proceedings—2009, international conference ReConFigurable computing and FPGAs, pp 172–177 Geninatti SR, Benavidez-Benitez SR, Hernandez-Calvino M, Guil-Mata N, Gomez-Luna J Fpga implementation of the generalized hough transform. In: Proceedings—2009, international conference ReConFigurable computing and FPGAs, pp 172–177
25.
Zurück zum Zitat Hardzeyeu V, Klefenz F (2008) On using the hough transform for driving assistance applications. In: 2008 International conference on intelligent computer communication and processing, pp 91–98 Hardzeyeu V, Klefenz F (2008) On using the hough transform for driving assistance applications. In: 2008 International conference on intelligent computer communication and processing, pp 91–98
26.
Zurück zum Zitat Sieler L, Tanougast C, Bouridane A (2010) A scalable and embedded FPGA architecture for efficient computation of grey level co-occurrence matrices and haralick textures features. Microprocess Microsyst 34(1):14–24CrossRef Sieler L, Tanougast C, Bouridane A (2010) A scalable and embedded FPGA architecture for efficient computation of grey level co-occurrence matrices and haralick textures features. Microprocess Microsyst 34(1):14–24CrossRef
27.
Zurück zum Zitat Tahir MA, Bouridane A, Kurugollu F (2004) An FPGA based coprocessor for the classification of tissue patterns in prostatic cancer. In: Becker J, Platzner M, Vernalde S (eds) Field programmable logic and application, vol. 3203 of Lecture Notes in Computer Science. Springer, Berlin, pp 771–780 Tahir MA, Bouridane A, Kurugollu F (2004) An FPGA based coprocessor for the classification of tissue patterns in prostatic cancer. In: Becker J, Platzner M, Vernalde S (eds) Field programmable logic and application, vol. 3203 of Lecture Notes in Computer Science. Springer, Berlin, pp 771–780
28.
Zurück zum Zitat Mitéran J, Matas J, Bourennane E, Paindavoine M, Dubois J (2005) Automatic hardware implementation tool for a discrete adaboost-based decision algorithm. EURASIP J Appl Signal Process 2005:1035–1046CrossRef Mitéran J, Matas J, Bourennane E, Paindavoine M, Dubois J (2005) Automatic hardware implementation tool for a discrete adaboost-based decision algorithm. EURASIP J Appl Signal Process 2005:1035–1046CrossRef
29.
Zurück zum Zitat Suissa A, Romain O, Denoulet J, Hachicha K, Garda P (2010) Empirical method based on neural networks for analog power modeling. Trans Comp Aided Des Intell Circuits Syst 29(5):839–844CrossRef Suissa A, Romain O, Denoulet J, Hachicha K, Garda P (2010) Empirical method based on neural networks for analog power modeling. Trans Comp Aided Des Intell Circuits Syst 29(5):839–844CrossRef
30.
Zurück zum Zitat Wang AY, Sodini CG (2006) On the energy efficiency of wireless transceivers. In: IEEE International Conference on Communications, 2006 (ICC ’06), vol 8, pp 3783–3788 Wang AY, Sodini CG (2006) On the energy efficiency of wireless transceivers. In: IEEE International Conference on Communications, 2006 (ICC ’06), vol 8, pp 3783–3788
31.
Zurück zum Zitat Kuon I, Rose J (2007) Measuring the gap between fpgas and asics. Trans Comp Aided Des Intell Circuits Syst 26(2):203–215CrossRef Kuon I, Rose J (2007) Measuring the gap between fpgas and asics. Trans Comp Aided Des Intell Circuits Syst 26(2):203–215CrossRef
Metadaten
Titel
Toward embedded detection of polyps in WCE images for early diagnosis of colorectal cancer
verfasst von
Juan Silva
Aymeric Histace
Olivier Romain
Xavier Dray
Bertrand Granado
Publikationsdatum
01.03.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 2/2014
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-013-0926-3

Weitere Artikel der Ausgabe 2/2014

International Journal of Computer Assisted Radiology and Surgery 2/2014 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.