Skip to main content
Erschienen in: International Journal of Computer Assisted Radiology and Surgery 8/2015

01.08.2015 | Original Article

Automatic segmentation of the nasal cavity and paranasal sinuses from cone-beam CT images

verfasst von: Nhat Linh Bui, Sim Heng Ong, Kelvin Weng Chiong Foong

Erschienen in: International Journal of Computer Assisted Radiology and Surgery | Ausgabe 8/2015

Einloggen, um Zugang zu erhalten

Abstract

Purpose

A patient-specific upper airway model is important for clinical, education, and research applications. Cone-beam computed tomography (CBCT) is used for imaging the upper airway but automatic segmentation is limited by noise and the complex anatomy. A multi-step level set segmentation scheme was developed for CBCT volumetric head scans to create a 3D model of the nasal cavity and paranasal sinuses.

Methods

Gaussian mixture model thresholding and morphological operators are first employed to automatically locate the region of interest and to initialize the active contour. Second, the active contour driven by the Kullback–Leibler (K–L) divergence energy in a level set framework to segment the upper airway. The K–L divergence asymmetry is used to directly minimize the K–L divergence energy on the probability density function of the image intensity. Finally, to refine the segmentation result, an anisotropic localized active contour is employed which defines the local area based on shape prior information. The method was tested on ten CBCT data sets. The results were evaluated by the Dice coefficient, the volumetric overlap error (VOE), precision, recall, and \(F\)-score and compared with expert manual segmentation and existing methods.

Results

The nasal cavity and paranasal sinuses were segmented in CBCT images with a median accuracy of 95.72 % [93.82–96.72 interquartile range] by Dice, 8.73 % [6.79–12.20] by VOE, 94.69 % [93.80–94.97] by precision, 97.73 % [92.70–98.79] by recall, and 95.72 % [93.82–96.69] by \(F\)-score.

Conclusion

Automated CBCT segmentation of the airway and paranasal sinuses was highly accurate in a test sample of clinical scans. The method may be useful in a variety of clinical, education, and research applications.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Jia W-H, Qin H-D (2012) Non-viral environmental risk factors for nasopharyngeal carcinoma: a systematic review. Semin Cancer Biol 22(2):117–126PubMedCrossRef Jia W-H, Qin H-D (2012) Non-viral environmental risk factors for nasopharyngeal carcinoma: a systematic review. Semin Cancer Biol 22(2):117–126PubMedCrossRef
2.
Zurück zum Zitat Young T, Peppard PE, Gottlieb DJ (2002) Epidemiology of obstructive sleep apnea: a population health perspective. Am J Respir Crit Care Med 165(9):1217–1239PubMedCrossRef Young T, Peppard PE, Gottlieb DJ (2002) Epidemiology of obstructive sleep apnea: a population health perspective. Am J Respir Crit Care Med 165(9):1217–1239PubMedCrossRef
3.
Zurück zum Zitat Lethbridge M, Schiller JS, Bernadel L (2004) Summary health statistics for U.S. adults: National Health Interview Survey, National Center for Health Statistics. Vital Health Stat 10:222 Lethbridge M, Schiller JS, Bernadel L (2004) Summary health statistics for U.S. adults: National Health Interview Survey, National Center for Health Statistics. Vital Health Stat 10:222
4.
Zurück zum Zitat Guijarro-Martinez R, Swennen GR (2011) Cone-beam computerized tomography imaging and analysis of the upper airway: a systematic review of the literature. Int J Oral Maxillofac Surg 40(11):1227–1237PubMedCrossRef Guijarro-Martinez R, Swennen GR (2011) Cone-beam computerized tomography imaging and analysis of the upper airway: a systematic review of the literature. Int J Oral Maxillofac Surg 40(11):1227–1237PubMedCrossRef
5.
Zurück zum Zitat Pauwels R, Beinsberger J, Collaert B, Theodorakou C, Rogers J, Walker A, Cockmartin L, Bosmans H, Jacobs R, Bogaerts R, Horner K (2012) Effective dose range for dental cone beam computed tomography scanners. Eur J Radiol 81(2):267–271PubMedCrossRef Pauwels R, Beinsberger J, Collaert B, Theodorakou C, Rogers J, Walker A, Cockmartin L, Bosmans H, Jacobs R, Bogaerts R, Horner K (2012) Effective dose range for dental cone beam computed tomography scanners. Eur J Radiol 81(2):267–271PubMedCrossRef
6.
Zurück zum Zitat Loubele M, Bogaerts R, Dijck EV, Pauwels R, Vanheusden S, Suetens P, Marchal G, Sanderink G, Jacobs R (2009) Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications. Eur J Radiol 71(3):461–468 osteoporosisPubMedCrossRef Loubele M, Bogaerts R, Dijck EV, Pauwels R, Vanheusden S, Suetens P, Marchal G, Sanderink G, Jacobs R (2009) Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications. Eur J Radiol 71(3):461–468 osteoporosisPubMedCrossRef
7.
Zurück zum Zitat Sutthiprapaporn P, Tanimoto K, Ohtsuka M, Nagasaki T, Konishi M, Iida Y, Katsumata A (2008) Improved inspection of the lateral pharyngeal recess using cone-beam computed tomography in the upright position. Oral Radiol 24:71–75CrossRef Sutthiprapaporn P, Tanimoto K, Ohtsuka M, Nagasaki T, Konishi M, Iida Y, Katsumata A (2008) Improved inspection of the lateral pharyngeal recess using cone-beam computed tomography in the upright position. Oral Radiol 24:71–75CrossRef
8.
Zurück zum Zitat Katsumata A, Hirukawa A, Noujeim M, Okumura S, Naitoh M, Fujishita M, Ariji E, Langlais RP (2006) Image artifact in dental cone-beam CT. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 101:652–657PubMedCrossRef Katsumata A, Hirukawa A, Noujeim M, Okumura S, Naitoh M, Fujishita M, Ariji E, Langlais RP (2006) Image artifact in dental cone-beam CT. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 101:652–657PubMedCrossRef
9.
Zurück zum Zitat Alsufyani NA, Flores-Mir C, Major PW (2012) Three-dimensional segmentation of the upper airway using cone beam CT: a systematic review. Dentomaxillofac Radiol 41(4):276–284PubMedCentralPubMedCrossRef Alsufyani NA, Flores-Mir C, Major PW (2012) Three-dimensional segmentation of the upper airway using cone beam CT: a systematic review. Dentomaxillofac Radiol 41(4):276–284PubMedCentralPubMedCrossRef
10.
Zurück zum Zitat Ogawa T, Enciso R, Shintaku WH, Clark GT (2007) Evaluation of cross-section airway configuration of obstructive sleep apnea. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 103:102–108PubMedCentralPubMedCrossRef Ogawa T, Enciso R, Shintaku WH, Clark GT (2007) Evaluation of cross-section airway configuration of obstructive sleep apnea. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 103:102–108PubMedCentralPubMedCrossRef
11.
Zurück zum Zitat Celenk M, Farrell ML, Eren H, Kumar K, Singh GD, Lozanoff S (2010) Upper airway detection and visualization from cone beam image slices. J Xray Sci Technol 18:121–135PubMed Celenk M, Farrell ML, Eren H, Kumar K, Singh GD, Lozanoff S (2010) Upper airway detection and visualization from cone beam image slices. J Xray Sci Technol 18:121–135PubMed
12.
Zurück zum Zitat Weissheimer A, de Menezes LM, Sameshima GT, Enciso R, Pham J, Grauer D (2012) Imaging software accuracy for 3-dimensional analysis of the upper airway. Am J Orthod Dentofacial Orthop 142(6):801–813PubMedCrossRef Weissheimer A, de Menezes LM, Sameshima GT, Enciso R, Pham J, Grauer D (2012) Imaging software accuracy for 3-dimensional analysis of the upper airway. Am J Orthod Dentofacial Orthop 142(6):801–813PubMedCrossRef
13.
Zurück zum Zitat El H, Palomo JM (2010) Measuring the airway in 3 dimensions: A reliability and accuracy study. Am J Orthod Dentofacial Orthop 137:S50.e1–S50.e9 El H, Palomo JM (2010) Measuring the airway in 3 dimensions: A reliability and accuracy study. Am J Orthod Dentofacial Orthop 137:S50.e1–S50.e9
14.
Zurück zum Zitat Stratemann S, Huang JC, Maki K, Hatcher D, Millere AJ (2011) Three-dimensional analysis of the airway with cone-beam computed tomography. Am J Orthod Dentofacial Orthop 140:607–615PubMedCrossRef Stratemann S, Huang JC, Maki K, Hatcher D, Millere AJ (2011) Three-dimensional analysis of the airway with cone-beam computed tomography. Am J Orthod Dentofacial Orthop 140:607–615PubMedCrossRef
15.
Zurück zum Zitat Shi H, Scarfe WC, Farman AG (2006) Upper airway segmentation and dimensions estimation from cone-beam CT image datasets. Int J Comput Assist Radiol Surg 1:177–186CrossRef Shi H, Scarfe WC, Farman AG (2006) Upper airway segmentation and dimensions estimation from cone-beam CT image datasets. Int J Comput Assist Radiol Surg 1:177–186CrossRef
16.
Zurück zum Zitat Cheng I, Nilufar S, Flores-Mir C, Basu A (2007) Airway segmentation and measurement in CT images. In: 29th annual international conference of the IEEE engineering in medicine and biology society’2007. IEEE EMBC, Lyon, France Cheng I, Nilufar S, Flores-Mir C, Basu A (2007) Airway segmentation and measurement in CT images. In: 29th annual international conference of the IEEE engineering in medicine and biology society’2007. IEEE EMBC, Lyon, France
17.
Zurück zum Zitat Osher S, Fedkiw R (2003) Level set methods and dynamic implicit surfaces. Springer, BerlinCrossRef Osher S, Fedkiw R (2003) Level set methods and dynamic implicit surfaces. Springer, BerlinCrossRef
18.
Zurück zum Zitat Kullback S, Leibler RA (1951) On information and sufficiency. Ann Math Stat 22(1):79–86CrossRef Kullback S, Leibler RA (1951) On information and sufficiency. Ann Math Stat 22(1):79–86CrossRef
19.
Zurück zum Zitat Lankton S, Tannenbaum A (2008) Localizing region-based active contours. IEEE Trans Image Process 17(11):1–11CrossRef Lankton S, Tannenbaum A (2008) Localizing region-based active contours. IEEE Trans Image Process 17(11):1–11CrossRef
20.
Zurück zum Zitat Serra JP (1982) Image analysis and mathematical morphology. Academic Press Inc, London Serra JP (1982) Image analysis and mathematical morphology. Academic Press Inc, London
21.
Zurück zum Zitat Michailovich O, Rathi Y, Tannenbaum A (2007) Image segmentation using active contours driven by the Bhattacharyya gradient flow. IEEE Trans Image Process 16(11):2787–2801 Michailovich O, Rathi Y, Tannenbaum A (2007) Image segmentation using active contours driven by the Bhattacharyya gradient flow. IEEE Trans Image Process 16(11):2787–2801
22.
Zurück zum Zitat Lorensen WE, Cline HE (1987) Marching cubes: a high resolution 3D surface construction algorithm. Comput Graph 21(4):163–169CrossRef Lorensen WE, Cline HE (1987) Marching cubes: a high resolution 3D surface construction algorithm. Comput Graph 21(4):163–169CrossRef
23.
Zurück zum Zitat Chan TF, Vese LA (2001) Active contours without edges. IEEE Trans Image Process 10(2):266–277PubMedCrossRef Chan TF, Vese LA (2001) Active contours without edges. IEEE Trans Image Process 10(2):266–277PubMedCrossRef
24.
Zurück zum Zitat Trvillot V, Sobral R, Dombre E, Poignet P, Herman B, Crampette L (2013) Innovative endoscopic sino-nasal and anterior skull base robotics. Int J Comput Assist Radiol Surg 8(6):977–987CrossRef Trvillot V, Sobral R, Dombre E, Poignet P, Herman B, Crampette L (2013) Innovative endoscopic sino-nasal and anterior skull base robotics. Int J Comput Assist Radiol Surg 8(6):977–987CrossRef
Metadaten
Titel
Automatic segmentation of the nasal cavity and paranasal sinuses from cone-beam CT images
verfasst von
Nhat Linh Bui
Sim Heng Ong
Kelvin Weng Chiong Foong
Publikationsdatum
01.08.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 8/2015
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-014-1134-5

Weitere Artikel der Ausgabe 8/2015

International Journal of Computer Assisted Radiology and Surgery 8/2015 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.