Abstract

Purpose

Our purpose is to develop a system based on image processing methods that can inform users of the angular relationship between the needle and the forceps. The user thereby adjusts their needle grasping posture according to the angle information, which leads to an improvement in suturing accuracy.

Methods

The system prototype consists of a camera and an image processing computer. The image captured by the camera is input to the computer, and then, the angular relationship between the forceps and needle is calculated via image processing. Then, the system informs the user of the calculated angular relationship between the needle and forceps in real time. To evaluate whether the system improves suturing accuracy, we invited 12 participants to enroll in an experiment based on a suturing task.

Results

The experimental results illustrate that the system allows participants to easily adjust the positional relationship between the needle and the forceps and that this adjusted angular relationship leads to higher suturing accuracy.

Conclusions

Adjustment to holding the needle at a right angle before insertion has a critical effect on suturing quality. Therefore, we developed a system that informs the user of the angular relationship between the needle and the forceps. The results of the evaluation show that the system significantly improves the suturing accuracy of participants via informing them of the angle.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Rassweiler J, Gözen AS, Frede T, Teber D (2011) Laparoscopy vs. robotics: ergonomics–Does it matter? In: Hemal AK, Menon M (eds) Robotics in genitourinary surgery. Springer, London, pp 63–78. doi:10.1007/978-1-84882-114-9_5 CrossRef Rassweiler J, Gözen AS, Frede T, Teber D (2011) Laparoscopy vs. robotics: ergonomics–Does it matter? In: Hemal AK, Menon M (eds) Robotics in genitourinary surgery. Springer, London, pp 63–78. doi:10.​1007/​978-1-84882-114-9_​5 CrossRef
2.
Zurück zum Zitat Vilos GA, Ternamian A, Dempster J, Laberge PY (2007) Laparoscopic entry: a review of techniques, technologies, and complications. J Obstet Gynaecol Can 29:433–447CrossRefPubMed Vilos GA, Ternamian A, Dempster J, Laberge PY (2007) Laparoscopic entry: a review of techniques, technologies, and complications. J Obstet Gynaecol Can 29:433–447CrossRefPubMed
3.
Zurück zum Zitat Dorsey JH, Tabb CR, Zucker KA (2001) Laparoscopic suturing and knot tying. In: Zucker KA (ed) Surgical laparoscopy. Lippincott Williams & Williams, Philadelphia, pp 77–95 Dorsey JH, Tabb CR, Zucker KA (2001) Laparoscopic suturing and knot tying. In: Zucker KA (ed) Surgical laparoscopy. Lippincott Williams & Williams, Philadelphia, pp 77–95
4.
Zurück zum Zitat Jain N (2006) Laparoscopic needle holders and knot pushers. In: Zucker KA (ed) State of the art atlas and textbook of laparoscopic suturing. Jaypee Brothers Publishers, New Delhi, pp 18–20CrossRef Jain N (2006) Laparoscopic needle holders and knot pushers. In: Zucker KA (ed) State of the art atlas and textbook of laparoscopic suturing. Jaypee Brothers Publishers, New Delhi, pp 18–20CrossRef
5.
Zurück zum Zitat Joice P, Hanna G, Cuschieri A (1998) Ergonomic evaluation of laparoscopic bowel suturing. Am J Surg 176:373–378CrossRefPubMed Joice P, Hanna G, Cuschieri A (1998) Ergonomic evaluation of laparoscopic bowel suturing. Am J Surg 176:373–378CrossRefPubMed
6.
Zurück zum Zitat Allan M, Chang PL, Ourselin S, Hawkes DJ, Sridhar A, Kelly J, Stoyanov D (2015) Image based surgical instrument pose estimation with multi-class labelling and optical flow. Medical image computing and computer-assisted intervention - MICCAI 2015, pp 331–338 Allan M, Chang PL, Ourselin S, Hawkes DJ, Sridhar A, Kelly J, Stoyanov D (2015) Image based surgical instrument pose estimation with multi-class labelling and optical flow. Medical image computing and computer-assisted intervention - MICCAI 2015, pp 331–338
7.
Zurück zum Zitat Wengert C, Bossard L, Häberling A, Baur C, Székely G, Cattin PC (2007) Endoscopic navigation for minimally invasive suturing. In: International conference on medical image computing and computer-assisted intervention. Springer, Berlin, pp 620–627 Wengert C, Bossard L, Häberling A, Baur C, Székely G, Cattin PC (2007) Endoscopic navigation for minimally invasive suturing. In: International conference on medical image computing and computer-assisted intervention. Springer, Berlin, pp 620–627
8.
Zurück zum Zitat Koreeda Y, Kobayashi Y, Ieiri S, Nishio Y, Kawamura K, Obata S, Souzaki R, Hashizume M, Fujie MG (2016) Virtually transparent surgical instruments in endoscopic surgery with augmentation of obscured regions. Int J Comput Assist Radiol Surg 11:1927–1936. doi:10.1007/s11548-016-1384-5 CrossRefPubMed Koreeda Y, Kobayashi Y, Ieiri S, Nishio Y, Kawamura K, Obata S, Souzaki R, Hashizume M, Fujie MG (2016) Virtually transparent surgical instruments in endoscopic surgery with augmentation of obscured regions. Int J Comput Assist Radiol Surg 11:1927–1936. doi:10.​1007/​s11548-016-1384-5 CrossRefPubMed
9.
Zurück zum Zitat Cucchiara R, Grana C, Piccardi M, Prati A, Sirotti S (2001) Improving shadow suppression in moving object detection with HSV color information. In: 2001 IEEE Intelligent Transportation Systems Proceedings, pp 334–339 Cucchiara R, Grana C, Piccardi M, Prati A, Sirotti S (2001) Improving shadow suppression in moving object detection with HSV color information. In: 2001 IEEE Intelligent Transportation Systems Proceedings, pp 334–339
12.
Zurück zum Zitat Beland LJ, Mourou W (2009) Image segmentation: a watershed transformation algorithm. Image Anal Stereol 28:93–102 Beland LJ, Mourou W (2009) Image segmentation: a watershed transformation algorithm. Image Anal Stereol 28:93–102
13.
Zurück zum Zitat Miall RC, Wolpert DM (1996) Forward models for physiological motor control. Neural Netw 9:1265–1279CrossRefPubMed Miall RC, Wolpert DM (1996) Forward models for physiological motor control. Neural Netw 9:1265–1279CrossRefPubMed
14.
Zurück zum Zitat Enomoto M (1978) The experimental studies on the anastomotic technic of one-layer colonic anastomosis. Jpn J Gastroenterol Surg 11:737–747CrossRef Enomoto M (1978) The experimental studies on the anastomotic technic of one-layer colonic anastomosis. Jpn J Gastroenterol Surg 11:737–747CrossRef
Metadaten
Titel
Development of angle information system to facilitate the adjustment of needle-holding posture
verfasst von
Yang Cao
Li Liu
Satoshi Miura
Masaki Seki
Yo Kobayashi
Kazuya Kawamura
Masakatsu G. Fujie
Publikationsdatum
29.05.2017
Verlag
Springer International Publishing
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 11/2017
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-017-1617-2

Weitere Artikel der Ausgabe 11/2017

International Journal of Computer Assisted Radiology and Surgery 11/2017 Zur Ausgabe

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Wie toxische Männlichkeit der Gesundheit von Männern schadet

08.04.2024 Andrologie Nachrichten

Stark, erfolgreich, allzeit belastbar – das sind Erwartungen, die Jungen und Männer von der Gesellschaft spüren. Das kann sie „toxisch“ werden lassen – und letztlich sogar der Gesundheit schaden, mahnt Dr. Dirk Sander von der Deutschen Aidshilfe.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.