Skip to main content
Erschienen in: Journal of Nuclear Cardiology 3/2021

31.05.2019 | Original Article

Comparative analysis between myocardial perfusion reserve and maximal ischemia score at single photon emission computed tomography with new-generation cadmium-zinc-telluride cameras

verfasst von: Francesco Nudi, MD, Giuseppe Biondi-Zoccai, MD, MStat, Alessandro Nudi, MD, Giandomenico Neri, MD, Enrica Procaccini, MD, Orazio Schilllaci, MD

Erschienen in: Journal of Nuclear Cardiology | Ausgabe 3/2021

Einloggen, um Zugang zu erhalten

Abstract

Background

Whether estimates of myocardial perfusion reserve (MPR) stemming from new-generation cadmium-zinc-telluride (CZT) cameras are accurate remains unclear.

Methods

We queried our institutional database for patients undergoing MPR with CZT cameras. The primary goal was appraising the incremental diagnostic yield of MPR on top or at odds of maximal ischemia score (MIS).

Results

A total of 66 subjects were included. When distinguishing patients according to normal vs abnormal MPR (cut-off 2.1 mL/min/g) and normal vs abnormal MIS, 4 groups could be identified: 12 (18.1%) individuals with normal MPR and MIS, 12 (18.1%) with normal MPR and abnormal MIS, 16 (24.2%) with abnormal MPR and normal MIS, and 26 (39.4%) with abnormal MPR and MIS. MIS was significantly associated with several baseline features, whereas MPR did not. There was no significant association between MPR and MIS, nor with regional perfusion. Clinical outcomes were uncommon and not significantly associated with MPR or MIS, whereas angiographically significant coronary artery disease (CAD) was associated solely with MIS (P < 0.05), and not with MPR.

Conclusions

There is limited agreement between CZT-derived MPR and baseline risk, perfusion and angiography results. Whether such discrepancies may still prove incrementally beneficial for the diagnosis or prognosis of CAD remains unclear.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Iskandrian AE, Garcia EV. Nuclear cardiac imaging: Principles and applications. Oxford: Oxford University Press; 2008. Iskandrian AE, Garcia EV. Nuclear cardiac imaging: Principles and applications. Oxford: Oxford University Press; 2008.
3.
Zurück zum Zitat Nudi F, Biondi-Zoccai G. Cadmium-zinc-telluride myocardial perfusion imaging: The dream of a single test gets nearer. J Nucl Cardiol 2018;25:550-4.CrossRef Nudi F, Biondi-Zoccai G. Cadmium-zinc-telluride myocardial perfusion imaging: The dream of a single test gets nearer. J Nucl Cardiol 2018;25:550-4.CrossRef
4.
Zurück zum Zitat Nudi F, Iskandrian AE, Schillaci O, Peruzzi M, Frati G, Biondi-Zoccai G. Diagnostic accuracy of myocardial perfusion imaging with CZT technology: Systemic review and meta-analysis of comparison with invasive coronary angiography. JACC Cardiovasc Imaging 2017;10:787-94.CrossRef Nudi F, Iskandrian AE, Schillaci O, Peruzzi M, Frati G, Biondi-Zoccai G. Diagnostic accuracy of myocardial perfusion imaging with CZT technology: Systemic review and meta-analysis of comparison with invasive coronary angiography. JACC Cardiovasc Imaging 2017;10:787-94.CrossRef
5.
Zurück zum Zitat Nkoulou R, Fuchs TA, Pazhenkottil AP, Kuest SM, Ghadri JR, Stehli J, Fiechter M, Herzog BA, Gaemperli O, Buechel RR, Kaufmann PA. Absolute myocardial blood flow and flow reserve assessed by gated SPECT with cadmium-zinc-telluride detectors using 99mTc-tetrofosmin: Head-to-head comparison with 13 N-ammonia PET. J Nucl Med 2016;57:1887-92.CrossRef Nkoulou R, Fuchs TA, Pazhenkottil AP, Kuest SM, Ghadri JR, Stehli J, Fiechter M, Herzog BA, Gaemperli O, Buechel RR, Kaufmann PA. Absolute myocardial blood flow and flow reserve assessed by gated SPECT with cadmium-zinc-telluride detectors using 99mTc-tetrofosmin: Head-to-head comparison with 13 N-ammonia PET. J Nucl Med 2016;57:1887-92.CrossRef
6.
Zurück zum Zitat Wells RG, Marvin B, Poirier M, Renaud J, deKemp RA, Ruddy TD. Optimization of SPECT measurement of myocardial blood flow with corrections for attenuation, motion, and blood binding compared with PET. J Nucl Med 2017;58:2013-9.CrossRef Wells RG, Marvin B, Poirier M, Renaud J, deKemp RA, Ruddy TD. Optimization of SPECT measurement of myocardial blood flow with corrections for attenuation, motion, and blood binding compared with PET. J Nucl Med 2017;58:2013-9.CrossRef
7.
Zurück zum Zitat Shiraishi S, Sakamoto F, Tsuda N, Yoshida M, Tomiguchi S, Utsunomiya D, Ogawa H, Yamashita Y. Prediction of left main or 3-vessel disease using myocardial perfusion reserve on dynamic thallium-201 single-photon emission computed tomography with a semiconductor gamma camera. Circ J 2015;79:623-31.CrossRef Shiraishi S, Sakamoto F, Tsuda N, Yoshida M, Tomiguchi S, Utsunomiya D, Ogawa H, Yamashita Y. Prediction of left main or 3-vessel disease using myocardial perfusion reserve on dynamic thallium-201 single-photon emission computed tomography with a semiconductor gamma camera. Circ J 2015;79:623-31.CrossRef
8.
Zurück zum Zitat Tsuda N, Shiraishi S, Sakamoto F, Yuki H, Ogasawara K, Yoshida M, Tomiguchi S, Tsujita K, Yamashita Y. Quantification of myocardial perfusion reserve using dynamic SPECT images of patients with chronic kidney disease. J Cardiol 2018;71:174-80.CrossRef Tsuda N, Shiraishi S, Sakamoto F, Yuki H, Ogasawara K, Yoshida M, Tomiguchi S, Tsujita K, Yamashita Y. Quantification of myocardial perfusion reserve using dynamic SPECT images of patients with chronic kidney disease. J Cardiol 2018;71:174-80.CrossRef
9.
Zurück zum Zitat Giubbini R, Peli A, Milan E, Sciagrà R, Camoni L, Albano D, Bertoli M, Bonacina M, Motta F, Statuto M, Rodella CA, De Agostini A, Calabretta R, Bertagna F, Italian Nuclear Cardiology Group (GICN). Comparison between the summed difference score and myocardial blood flow measured by 13 N-ammonia. J Nucl Cardiol 2018;25:1621-8.CrossRef Giubbini R, Peli A, Milan E, Sciagrà R, Camoni L, Albano D, Bertoli M, Bonacina M, Motta F, Statuto M, Rodella CA, De Agostini A, Calabretta R, Bertagna F, Italian Nuclear Cardiology Group (GICN). Comparison between the summed difference score and myocardial blood flow measured by 13 N-ammonia. J Nucl Cardiol 2018;25:1621-8.CrossRef
10.
Zurück zum Zitat Nudi F, Pinto A, Procaccini E, Neri G, Vetere M, Tomai F, Gaspardone A, Biondi-Zoccai G, Schillaci O. A novel clinically relevant segmentation method and corresponding maximal ischemia score to risk-stratify patients undergoing myocardial perfusion scintigraphy. J Nucl Cardiol 2014;21:807-18.CrossRef Nudi F, Pinto A, Procaccini E, Neri G, Vetere M, Tomai F, Gaspardone A, Biondi-Zoccai G, Schillaci O. A novel clinically relevant segmentation method and corresponding maximal ischemia score to risk-stratify patients undergoing myocardial perfusion scintigraphy. J Nucl Cardiol 2014;21:807-18.CrossRef
11.
Zurück zum Zitat Nudi F, Schillaci O, Neri G, Pinto A, Procaccini E, Vetere M, Frati G, Tomai F, Biondi-Zoccai G. Prognostic impact of location and extent of vessel-related ischemia at myocardial perfusion scintigraphy in patients with or at risk for coronary artery disease. J Nucl Cardiol 2016;23:274-84.CrossRef Nudi F, Schillaci O, Neri G, Pinto A, Procaccini E, Vetere M, Frati G, Tomai F, Biondi-Zoccai G. Prognostic impact of location and extent of vessel-related ischemia at myocardial perfusion scintigraphy in patients with or at risk for coronary artery disease. J Nucl Cardiol 2016;23:274-84.CrossRef
12.
Zurück zum Zitat Fang YD, Liu YC, Ho KC, Kuo FC, Yang CF, Yen TC, Hsieh IC. Single-scan rest/stress imaging with 99mTc-sestamibi and cadmium zinc telluride-based SPECT for hyperemic flow quantification: A feasibility study evaluated with cardiac magnetic resonance imaging. PLoS ONE 2017;12:e0183402.CrossRef Fang YD, Liu YC, Ho KC, Kuo FC, Yang CF, Yen TC, Hsieh IC. Single-scan rest/stress imaging with 99mTc-sestamibi and cadmium zinc telluride-based SPECT for hyperemic flow quantification: A feasibility study evaluated with cardiac magnetic resonance imaging. PLoS ONE 2017;12:e0183402.CrossRef
13.
Zurück zum Zitat Ben Bouallègue F, Roubille F, Lattuca B, Cung TT, Macia JC, Gervasoni R, Leclercq F, Mariano-Goulart D. SPECT myocardial perfusion reserve in patients with multivessel coronary disease: Correlation with angiographic findings and invasive fractional flow reserve measurements. J Nucl Med 2015;56:1712-7.CrossRef Ben Bouallègue F, Roubille F, Lattuca B, Cung TT, Macia JC, Gervasoni R, Leclercq F, Mariano-Goulart D. SPECT myocardial perfusion reserve in patients with multivessel coronary disease: Correlation with angiographic findings and invasive fractional flow reserve measurements. J Nucl Med 2015;56:1712-7.CrossRef
14.
Zurück zum Zitat Piccinelli M, Votaw JR, Garcia EV. Motion correction and its impact on absolute myocardial blood flow measures with PET. Curr Cardiol Rep 2018;20:34.CrossRef Piccinelli M, Votaw JR, Garcia EV. Motion correction and its impact on absolute myocardial blood flow measures with PET. Curr Cardiol Rep 2018;20:34.CrossRef
15.
Zurück zum Zitat Agostini D, Roule V, Nganoa C, Roth N, Baavour R, Parienti JJ, Beygui F, Manrique A. First validation of myocardial flow reserve assessed by dynamic 99mTc-sestamibi CZT-SPECT camera: head to head comparison with 15O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study. Eur J Nucl Med Mol Imaging 2018;45:1079-90.CrossRef Agostini D, Roule V, Nganoa C, Roth N, Baavour R, Parienti JJ, Beygui F, Manrique A. First validation of myocardial flow reserve assessed by dynamic 99mTc-sestamibi CZT-SPECT camera: head to head comparison with 15O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study. Eur J Nucl Med Mol Imaging 2018;45:1079-90.CrossRef
19.
Zurück zum Zitat Mangiacapra F, Bressi E, Sticchi A, Morisco C, Barbato E. Fractional flow reserve (FFR) as a guide to treat coronary artery disease. Expert Rev Cardiovasc Ther 2018;16:465-77.CrossRef Mangiacapra F, Bressi E, Sticchi A, Morisco C, Barbato E. Fractional flow reserve (FFR) as a guide to treat coronary artery disease. Expert Rev Cardiovasc Ther 2018;16:465-77.CrossRef
20.
Zurück zum Zitat Nudi F, Di Belardino N, Pinto A, Procaccini E, Neri G, Schillaci O, Tomai F, Frati G, Biondi-Zoccai G. Assessment of the fate of myocardial necrosis by serial myocardial perfusion imaging. J Nucl Cardiol 2018;25:496-505.CrossRef Nudi F, Di Belardino N, Pinto A, Procaccini E, Neri G, Schillaci O, Tomai F, Frati G, Biondi-Zoccai G. Assessment of the fate of myocardial necrosis by serial myocardial perfusion imaging. J Nucl Cardiol 2018;25:496-505.CrossRef
21.
Zurück zum Zitat Nudi F, Procaccini E, Versaci F, Giordano A, Pinto A, Neri G, Frati G, Schillaci O, Nudi A, Tomai F, Biondi-Zoccai G. Impact of coronary revascularization on the clinical and scintigraphic outlook of patients with myocardial ischemia. J Cardiovasc Med 2017;18:404-9.CrossRef Nudi F, Procaccini E, Versaci F, Giordano A, Pinto A, Neri G, Frati G, Schillaci O, Nudi A, Tomai F, Biondi-Zoccai G. Impact of coronary revascularization on the clinical and scintigraphic outlook of patients with myocardial ischemia. J Cardiovasc Med 2017;18:404-9.CrossRef
Metadaten
Titel
Comparative analysis between myocardial perfusion reserve and maximal ischemia score at single photon emission computed tomography with new-generation cadmium-zinc-telluride cameras
verfasst von
Francesco Nudi, MD
Giuseppe Biondi-Zoccai, MD, MStat
Alessandro Nudi, MD
Giandomenico Neri, MD
Enrica Procaccini, MD
Orazio Schilllaci, MD
Publikationsdatum
31.05.2019
Verlag
Springer International Publishing
Erschienen in
Journal of Nuclear Cardiology / Ausgabe 3/2021
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-019-01764-2

Weitere Artikel der Ausgabe 3/2021

Journal of Nuclear Cardiology 3/2021 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.