Skip to main content
Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology 11/2018

02.08.2018 | Glaucoma

Low iris and anterior chamber volume is associated with deepening after laser peripheral iridotomy in primary angle closure suspects

verfasst von: Hamed Esfandiari, Mohammad Pakravan, Nassim Amouhashemi, Mehdi Yaseri, Pooya Torkian, Khosrow Jadidi, Nils A Loewen

Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology | Ausgabe 11/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To evaluate the association between baseline ocular variables and the widening of the anterior chamber angle by laser peripheral iridotomy (LPI) in primary angle closure suspects (PACS) using a new Fourier-domain swept-source anterior segment optical coherence tomography (FD-ASOCT).

Method

Sixty-six PACS eyes of 41 individuals were enrolled in this prospective interventional case series. An FD-ASOCT (Casia SS-1000 OCT; Tomey, Nagoya, Japan) was used to measure biometric baseline variables and at 1 month after the LPI. Paired t test was used to compare the difference between pre-and post-LPI measurements. Multivariate regression analysis was used to test for an association between baseline iris thickness and volume, anterior chamber depth and volume, and lens vault with a widening of the angle after an LPI. Changes in trabecular iris space area and angle opening distance after the LPI were main outcome measures.

Results

The mean age of participants was 58.6 ± 8.7 years, 68.2% of whom were female. The angle opening distance, recess area, and trabecular iris surface area at 500 μm increased by 48 to 73% (all P < 0.001). Lens vault and iris volume did not change. A low anterior chamber volume and low iris volume were associated with angle greater deepening by LPI.

Conclusion

Eyes with a shallow anterior chamber and thinner irises are more likely to experience angle opening from an LPI.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Sun X, Dai Y, Chen Y et al (2017) Primary angle closure glaucoma: what we know and what we don’t know. Prog Retin Eye Res 57:26–45CrossRef Sun X, Dai Y, Chen Y et al (2017) Primary angle closure glaucoma: what we know and what we don’t know. Prog Retin Eye Res 57:26–45CrossRef
2.
Zurück zum Zitat Tham Y-C, Li X, Wong TY et al (2014) Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis. Ophthalmology 121:2081–2090CrossRef Tham Y-C, Li X, Wong TY et al (2014) Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis. Ophthalmology 121:2081–2090CrossRef
3.
Zurück zum Zitat Pakravan M, Yazdani S, Javadi M-A et al (2013) A population-based survey of the prevalence and types of glaucoma in Central Iran: the Yazd eye study. Ophthalmology 120:1977–1984CrossRef Pakravan M, Yazdani S, Javadi M-A et al (2013) A population-based survey of the prevalence and types of glaucoma in Central Iran: the Yazd eye study. Ophthalmology 120:1977–1984CrossRef
4.
Zurück zum Zitat Lowe RF (1970) Aetiology of the anatomical basis for primary angle-closure glaucoma. Biometrical comparisons between normal eyes and eyes with primary angle-closure glaucoma. Br J Ophthalmol 54:161–169CrossRef Lowe RF (1970) Aetiology of the anatomical basis for primary angle-closure glaucoma. Biometrical comparisons between normal eyes and eyes with primary angle-closure glaucoma. Br J Ophthalmol 54:161–169CrossRef
5.
Zurück zum Zitat Lee DA, Brubaker RF, Ilstrup DM (1984) Anterior chamber dimensions in patients with narrow angles and angle-closure glaucoma. Arch Ophthalmol 102:46–50CrossRef Lee DA, Brubaker RF, Ilstrup DM (1984) Anterior chamber dimensions in patients with narrow angles and angle-closure glaucoma. Arch Ophthalmol 102:46–50CrossRef
6.
Zurück zum Zitat Marchini G, Pagliarusco A, Toscano A et al (1998) Ultrasound biomicroscopic and conventional ultrasonographic study of ocular dimensions in primary angle-closure glaucoma. Ophthalmology 105:2091–2098CrossRef Marchini G, Pagliarusco A, Toscano A et al (1998) Ultrasound biomicroscopic and conventional ultrasonographic study of ocular dimensions in primary angle-closure glaucoma. Ophthalmology 105:2091–2098CrossRef
7.
Zurück zum Zitat Tarongoy P, Ho CL, Walton DS (2009) Angle-closure glaucoma: the role of the lens in the pathogenesis, prevention, and treatment. Surv Ophthalmol 54:211–225CrossRef Tarongoy P, Ho CL, Walton DS (2009) Angle-closure glaucoma: the role of the lens in the pathogenesis, prevention, and treatment. Surv Ophthalmol 54:211–225CrossRef
8.
Zurück zum Zitat Wang N, Ouyang J, Zhou W et al (2000) [Multiple patterns of angle closure mechanisms in primary angle closure glaucoma in Chinese]. Zhonghua Yan Ke Za Zhi 36:46–51 5, 6PubMed Wang N, Ouyang J, Zhou W et al (2000) [Multiple patterns of angle closure mechanisms in primary angle closure glaucoma in Chinese]. Zhonghua Yan Ke Za Zhi 36:46–51 5, 6PubMed
9.
Zurück zum Zitat Congdon NG, Youlin Q, Quigley H et al (1997) Biometry and primary angle-closure glaucoma among Chinese, white, and black populations. Ophthalmology 104:1489–1495CrossRef Congdon NG, Youlin Q, Quigley H et al (1997) Biometry and primary angle-closure glaucoma among Chinese, white, and black populations. Ophthalmology 104:1489–1495CrossRef
10.
Zurück zum Zitat Nongpiur ME, He M, Amerasinghe N et al (2011) Lens vault, thickness, and position in Chinese subjects with angle closure. Ophthalmology 118:474–479CrossRef Nongpiur ME, He M, Amerasinghe N et al (2011) Lens vault, thickness, and position in Chinese subjects with angle closure. Ophthalmology 118:474–479CrossRef
11.
Zurück zum Zitat Thomas R, George R, Parikh R et al (2003) Five year risk of progression of primary angle closure suspects to primary angle closure: a population based study. Br J Ophthalmol 87:450–454CrossRef Thomas R, George R, Parikh R et al (2003) Five year risk of progression of primary angle closure suspects to primary angle closure: a population based study. Br J Ophthalmol 87:450–454CrossRef
12.
Zurück zum Zitat Schwartz LW, Rodrigues MM, Spaeth GL et al (1978) Argon laser iridotomy in the treatment of patients with primary angle-closure or pupillary block glaucoma: a clinicopathologic study. Ophthalmology 85:294–309CrossRef Schwartz LW, Rodrigues MM, Spaeth GL et al (1978) Argon laser iridotomy in the treatment of patients with primary angle-closure or pupillary block glaucoma: a clinicopathologic study. Ophthalmology 85:294–309CrossRef
13.
Zurück zum Zitat Lei K, Wang N, Wang L, Wang B (2007) Morphological changes of the anterior segment after laser peripheral iridotomy in primary angle closure. Eye 23:345–350CrossRef Lei K, Wang N, Wang L, Wang B (2007) Morphological changes of the anterior segment after laser peripheral iridotomy in primary angle closure. Eye 23:345–350CrossRef
14.
Zurück zum Zitat McGalliard JN, Wishart PK (1990) The effect of Nd:YAG iridotomy on intraocular pressure in hypertensive eyes with shallow anterior chambers. Eye 4(Pt 6):823–829CrossRef McGalliard JN, Wishart PK (1990) The effect of Nd:YAG iridotomy on intraocular pressure in hypertensive eyes with shallow anterior chambers. Eye 4(Pt 6):823–829CrossRef
15.
Zurück zum Zitat Dada T, Mohan S, Sihota R et al (2007) Comparison of ultrasound biomicroscopic parameters after laser iridotomy in eyes with primary angle closure and primary angle closure glaucoma. Eye 21:956–961CrossRef Dada T, Mohan S, Sihota R et al (2007) Comparison of ultrasound biomicroscopic parameters after laser iridotomy in eyes with primary angle closure and primary angle closure glaucoma. Eye 21:956–961CrossRef
16.
Zurück zum Zitat He M, Friedman DS, Ge J et al (2007) Laser peripheral iridotomy in eyes with narrow drainage angles: ultrasound biomicroscopy outcomes. The Liwan Eye Study. Ophthalmology 114:1513–1519CrossRef He M, Friedman DS, Ge J et al (2007) Laser peripheral iridotomy in eyes with narrow drainage angles: ultrasound biomicroscopy outcomes. The Liwan Eye Study. Ophthalmology 114:1513–1519CrossRef
17.
Zurück zum Zitat Yao B-Q, Wu L-L, Zhang C, Wang X (2009) Ultrasound biomicroscopic features associated with angle closure in fellow eyes of acute primary angle closure after laser iridotomy. Ophthalmology 116:444–448.e2CrossRef Yao B-Q, Wu L-L, Zhang C, Wang X (2009) Ultrasound biomicroscopic features associated with angle closure in fellow eyes of acute primary angle closure after laser iridotomy. Ophthalmology 116:444–448.e2CrossRef
18.
Zurück zum Zitat Gazzard G, Friedman DS, Devereux JG et al (2003) A prospective ultrasound biomicroscopy evaluation of changes in anterior segment morphology after laser iridotomy in Asian eyes. Ophthalmology 110:630–638CrossRef Gazzard G, Friedman DS, Devereux JG et al (2003) A prospective ultrasound biomicroscopy evaluation of changes in anterior segment morphology after laser iridotomy in Asian eyes. Ophthalmology 110:630–638CrossRef
19.
Zurück zum Zitat Lee KS, Sung KR, Kang SY et al (2011) Residual anterior chamber angle closure in narrow-angle eyes following laser peripheral iridotomy: anterior segment optical coherence tomography quantitative study. Jpn J Ophthalmol 55:213–219CrossRef Lee KS, Sung KR, Kang SY et al (2011) Residual anterior chamber angle closure in narrow-angle eyes following laser peripheral iridotomy: anterior segment optical coherence tomography quantitative study. Jpn J Ophthalmol 55:213–219CrossRef
20.
Zurück zum Zitat Quigley HA (1981) Long-term follow-up of laser iridotomy. Ophthalmology 88:218–224CrossRef Quigley HA (1981) Long-term follow-up of laser iridotomy. Ophthalmology 88:218–224CrossRef
21.
Zurück zum Zitat Pollack IP (1981) Laser iridotomy in the treatment of angle-closure glaucoma. Ann Ophthalmol 13:549–550PubMed Pollack IP (1981) Laser iridotomy in the treatment of angle-closure glaucoma. Ann Ophthalmol 13:549–550PubMed
22.
Zurück zum Zitat Friedman DS (2001) Who needs an iridotomy? Br J Ophthalmol 85:1019–1021CrossRef Friedman DS (2001) Who needs an iridotomy? Br J Ophthalmol 85:1019–1021CrossRef
23.
Zurück zum Zitat How AC, Baskaran M, Kumar RS et al (2012) Changes in anterior segment morphology after laser peripheral iridotomy: an anterior segment optical coherence tomography study. Ophthalmology 119:1383–1387CrossRef How AC, Baskaran M, Kumar RS et al (2012) Changes in anterior segment morphology after laser peripheral iridotomy: an anterior segment optical coherence tomography study. Ophthalmology 119:1383–1387CrossRef
24.
Zurück zum Zitat Lee RY, Kasuga T, Cui QN et al (2014) Association between baseline iris thickness and prophylactic laser peripheral iridotomy outcomes in primary angle-closure suspects. Ophthalmology 121:1194–1202CrossRef Lee RY, Kasuga T, Cui QN et al (2014) Association between baseline iris thickness and prophylactic laser peripheral iridotomy outcomes in primary angle-closure suspects. Ophthalmology 121:1194–1202CrossRef
25.
Zurück zum Zitat Foster PJ, Buhrmann R, Quigley HA, Johnson GJ (2002) The definition and classification of glaucoma in prevalence surveys. Br J Ophthalmol 86:238–242CrossRef Foster PJ, Buhrmann R, Quigley HA, Johnson GJ (2002) The definition and classification of glaucoma in prevalence surveys. Br J Ophthalmol 86:238–242CrossRef
26.
Zurück zum Zitat Shaffer RN (1960) Primary glaucomas. Gonioscopy, ophthalmoscopy and perimetry. Trans Am Acad Ophthalmol Otolaryngol 64:112–127PubMed Shaffer RN (1960) Primary glaucomas. Gonioscopy, ophthalmoscopy and perimetry. Trans Am Acad Ophthalmol Otolaryngol 64:112–127PubMed
27.
Zurück zum Zitat Liu S, Li H, Dorairaj S et al (2010) Assessment of scleral spur visibility with anterior segment optical coherence tomography. J Glaucoma 19:132–135CrossRef Liu S, Li H, Dorairaj S et al (2010) Assessment of scleral spur visibility with anterior segment optical coherence tomography. J Glaucoma 19:132–135CrossRef
28.
Zurück zum Zitat Mak H, Xu G, Leung CK-S (2013) Imaging the iris with swept-source optical coherence tomography: relationship between iris volume and primary angle closure. Ophthalmology 120:2517–2524CrossRef Mak H, Xu G, Leung CK-S (2013) Imaging the iris with swept-source optical coherence tomography: relationship between iris volume and primary angle closure. Ophthalmology 120:2517–2524CrossRef
29.
Zurück zum Zitat Liu S, Yu M, Ye C et al (2011) Anterior chamber angle imaging with swept-source optical coherence tomography: an investigation on variability of angle measurement. Invest Ophthalmol Vis Sci 52:8598–8603CrossRef Liu S, Yu M, Ye C et al (2011) Anterior chamber angle imaging with swept-source optical coherence tomography: an investigation on variability of angle measurement. Invest Ophthalmol Vis Sci 52:8598–8603CrossRef
30.
Zurück zum Zitat Lee RY, Kasuga T, Cui QN et al (2013) Association between baseline angle width and induced angle opening following prophylactic laser peripheral iridotomy. Invest Ophthalmol Vis Sci 54:3763–3770CrossRef Lee RY, Kasuga T, Cui QN et al (2013) Association between baseline angle width and induced angle opening following prophylactic laser peripheral iridotomy. Invest Ophthalmol Vis Sci 54:3763–3770CrossRef
31.
Zurück zum Zitat Yoong Leong JC, O’Connor J, Soon Ang G, Wells AP (2014) Anterior segment optical coherence tomography changes to the anterior chamber angle in the short-term following laser peripheral iridoplasty. J Curr Glaucoma Pract 8:1–6CrossRef Yoong Leong JC, O’Connor J, Soon Ang G, Wells AP (2014) Anterior segment optical coherence tomography changes to the anterior chamber angle in the short-term following laser peripheral iridoplasty. J Curr Glaucoma Pract 8:1–6CrossRef
32.
Zurück zum Zitat Ang BCH, Nongpiur ME, Aung T et al (2016) Changes in Japanese eyes after laser peripheral iridotomy: an anterior segment optical coherence tomography study. Clin Exp Ophthalmol 44:159–165CrossRef Ang BCH, Nongpiur ME, Aung T et al (2016) Changes in Japanese eyes after laser peripheral iridotomy: an anterior segment optical coherence tomography study. Clin Exp Ophthalmol 44:159–165CrossRef
33.
Zurück zum Zitat Ng WT, Morgan W (2012) Mechanisms and treatment of primary angle closure: a review. Clin Exp Ophthalmol 40:e218–e228CrossRef Ng WT, Morgan W (2012) Mechanisms and treatment of primary angle closure: a review. Clin Exp Ophthalmol 40:e218–e228CrossRef
34.
Zurück zum Zitat He M, Lu Y, Liu X et al (2008) Histologic changes of the iris in the development of angle closure in Chinese eyes. J Glaucoma 17:386–392CrossRef He M, Lu Y, Liu X et al (2008) Histologic changes of the iris in the development of angle closure in Chinese eyes. J Glaucoma 17:386–392CrossRef
35.
Zurück zum Zitat Oka N, Otori Y, Okada M et al (2006) Clinical study of anterior ocular segment topography in angle-closure glaucoma using the three-dimensional anterior segment analyzer Pentacam. Nippon Ganka Gakkai Zasshi 110(5):398–403PubMed Oka N, Otori Y, Okada M et al (2006) Clinical study of anterior ocular segment topography in angle-closure glaucoma using the three-dimensional anterior segment analyzer Pentacam. Nippon Ganka Gakkai Zasshi 110(5):398–403PubMed
36.
Zurück zum Zitat Coakes RL, Lloyd-Jones D, Hitchings RA (1979) Anterior chamber volume. Its measurement and clinical application. Trans Ophthalmol Soc U K 99:78–81PubMed Coakes RL, Lloyd-Jones D, Hitchings RA (1979) Anterior chamber volume. Its measurement and clinical application. Trans Ophthalmol Soc U K 99:78–81PubMed
37.
Zurück zum Zitat Dorairaj S, Liebmann JM, Ritch R (2007) Quantitative evaluation of anterior segment parameters in the era of imaging. Trans Am Ophthalmol Soc 105:99–108 discussion 108–10PubMedPubMedCentral Dorairaj S, Liebmann JM, Ritch R (2007) Quantitative evaluation of anterior segment parameters in the era of imaging. Trans Am Ophthalmol Soc 105:99–108 discussion 108–10PubMedPubMedCentral
38.
Zurück zum Zitat Radhakrishnan S, Goldsmith J, Huang D et al (2005) Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles. Arch Ophthalmol 123:1053–1059CrossRef Radhakrishnan S, Goldsmith J, Huang D et al (2005) Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles. Arch Ophthalmol 123:1053–1059CrossRef
Metadaten
Titel
Low iris and anterior chamber volume is associated with deepening after laser peripheral iridotomy in primary angle closure suspects
verfasst von
Hamed Esfandiari
Mohammad Pakravan
Nassim Amouhashemi
Mehdi Yaseri
Pooya Torkian
Khosrow Jadidi
Nils A Loewen
Publikationsdatum
02.08.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 11/2018
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-018-4092-8

Weitere Artikel der Ausgabe 11/2018

Graefe's Archive for Clinical and Experimental Ophthalmology 11/2018 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.