Skip to main content
Erschienen in: Clinical and Experimental Nephrology 3/2012

01.06.2012 | Review Article

Luminex and antibody detection in kidney transplantation

verfasst von: Antonietta Picascia, Teresa Infante, Claudio Napoli

Erschienen in: Clinical and Experimental Nephrology | Ausgabe 3/2012

Einloggen, um Zugang zu erhalten

Abstract

Preformed anti-human leukocyte antigen (HLA) antibodies have a negative effect on kidney transplantation outcome with an increased rejection rate and reduction in survival. Posttransplantation production of donor-specific anti-HLA antibodies is indicative of an active immune response and risk of transplantation rejection. For many years the primary technique for anti-HLA antibody detection was complement-dependent cytotoxicity (CDC), which has been integrated by solid-phase assays as HLA antigen-coated bead methods (Luminex). This new technological approach has allowed identification of anti-HLA antibodies, not detectable using conventional CDC method, in patients awaiting kidney transplantation. Moreover, use of Luminex technology has enabled better definition of acceptable or unacceptable antigens favoring transplantation in highly immunized patients. However, there are still many unresolved issues, including the clinical relevance of antibodies detected with this system.
Literatur
1.
Zurück zum Zitat Patel R, Terasaki PI. Significance of the positive crossmatch test in kidney transplantation. New Engl J Med. 1969;280:735–9.PubMedCrossRef Patel R, Terasaki PI. Significance of the positive crossmatch test in kidney transplantation. New Engl J Med. 1969;280:735–9.PubMedCrossRef
2.
Zurück zum Zitat Terasaki PI. Humoral theory of transplantation. Am J Transpl. 2003;3:665–73.CrossRef Terasaki PI. Humoral theory of transplantation. Am J Transpl. 2003;3:665–73.CrossRef
3.
Zurück zum Zitat Lefaucheur C, Loupy A, Hill GS, Andrade J, Nochy D, Antoine C, et al. Preexisting donor-specific HLA antibodies predict outcome in kidney transplantation. J Am Soc Nephrol. 2010;218:1398–406.CrossRef Lefaucheur C, Loupy A, Hill GS, Andrade J, Nochy D, Antoine C, et al. Preexisting donor-specific HLA antibodies predict outcome in kidney transplantation. J Am Soc Nephrol. 2010;218:1398–406.CrossRef
4.
Zurück zum Zitat Kaneku H. Impact of donor-specific HLA antibodies in transplantation, a review of the literature published in the last three years. Clin Transpl. 2010;283–306. Kaneku H. Impact of donor-specific HLA antibodies in transplantation, a review of the literature published in the last three years. Clin Transpl. 2010;283–306.
5.
Zurück zum Zitat Loupy A, Suberbielle-Boissel C, Hill GS, Lefaucheur C, Anglicheau D, Zuber J, et al. Outcome of subclinical antibody-mediated rejection in kidney transplant recipients with preformed donor-specific antibodies. Am J Transpl. 2009;9:2561–70.CrossRef Loupy A, Suberbielle-Boissel C, Hill GS, Lefaucheur C, Anglicheau D, Zuber J, et al. Outcome of subclinical antibody-mediated rejection in kidney transplant recipients with preformed donor-specific antibodies. Am J Transpl. 2009;9:2561–70.CrossRef
6.
Zurück zum Zitat Lachmann N, Terasaki PI, Budde K, Liefeldt L, Kahl A, Reinke P, et al. Anti-human leukocyte antigen and donor-specific antibodies detected by luminex posttransplant serve as biomarkers for chronic rejection of renal allografts. Transplantation. 2009;87:1505–13.PubMedCrossRef Lachmann N, Terasaki PI, Budde K, Liefeldt L, Kahl A, Reinke P, et al. Anti-human leukocyte antigen and donor-specific antibodies detected by luminex posttransplant serve as biomarkers for chronic rejection of renal allografts. Transplantation. 2009;87:1505–13.PubMedCrossRef
7.
Zurück zum Zitat Lee PC, Zhu L, Terasaki PI, Everly MJ. HLA-specific antibodies developed in the first year posttransplant are predictive of chronic rejection and renal graft loss. Transplantation. 2009;88:568–74.PubMedCrossRef Lee PC, Zhu L, Terasaki PI, Everly MJ. HLA-specific antibodies developed in the first year posttransplant are predictive of chronic rejection and renal graft loss. Transplantation. 2009;88:568–74.PubMedCrossRef
8.
Zurück zum Zitat Zhu L, Lee PC, Everly MJ, Terasaki PI. Detailed examination of HLA antibody development on renal allograft failure and function. Clin Transpl. 2008;171–87. Zhu L, Lee PC, Everly MJ, Terasaki PI. Detailed examination of HLA antibody development on renal allograft failure and function. Clin Transpl. 2008;171–87.
9.
Zurück zum Zitat Gloor JM. The utility of comprehensive assessment of donor specific anti-HLA antibodies in the clinical management of pediatric kidney transplant recipients. Pediatr Transpl. 2011;15:557–63. Gloor JM. The utility of comprehensive assessment of donor specific anti-HLA antibodies in the clinical management of pediatric kidney transplant recipients. Pediatr Transpl. 2011;15:557–63.
10.
Zurück zum Zitat Kao KJ, Scornik JC, Small SJ. Enzyme-linked immunoassay for anti-HLA antibodies—an alternative to panel studies by lymphocytotoxicity. Transplantation. 1993;55:192–6.PubMedCrossRef Kao KJ, Scornik JC, Small SJ. Enzyme-linked immunoassay for anti-HLA antibodies—an alternative to panel studies by lymphocytotoxicity. Transplantation. 1993;55:192–6.PubMedCrossRef
11.
Zurück zum Zitat Monien S, Salama A, Schönemann C. ELISA methods detect HLA antibodies with variable sensitivity. Int J Immunogenet. 2006;33:163–6.PubMedCrossRef Monien S, Salama A, Schönemann C. ELISA methods detect HLA antibodies with variable sensitivity. Int J Immunogenet. 2006;33:163–6.PubMedCrossRef
12.
Zurück zum Zitat Pajaro OE, George JF. On solid-phase antibody assays. J Heart Lung Transpl. 2010;29:1207–9.CrossRef Pajaro OE, George JF. On solid-phase antibody assays. J Heart Lung Transpl. 2010;29:1207–9.CrossRef
13.
Zurück zum Zitat Colombo MB, Haworth SE, Poli F, Nocco A, Puglisi G, Innocente A, et al. Luminex technology for anti-HLA antibody screening: evaluation of performance and of impact on laboratory routine. Cytometry B ClinCytom. 2007;72:465–71.CrossRef Colombo MB, Haworth SE, Poli F, Nocco A, Puglisi G, Innocente A, et al. Luminex technology for anti-HLA antibody screening: evaluation of performance and of impact on laboratory routine. Cytometry B ClinCytom. 2007;72:465–71.CrossRef
14.
Zurück zum Zitat Ozawa M, Verbanac KM, Catrou P, Haisch CE, Terasaki PI. Clinical and anti-HLA antibody profile of nine renal transplant recipients with failed grafts: donor-specific and non-donor-specific antibody development. Clin Transpl. 2006;241–53. Ozawa M, Verbanac KM, Catrou P, Haisch CE, Terasaki PI. Clinical and anti-HLA antibody profile of nine renal transplant recipients with failed grafts: donor-specific and non-donor-specific antibody development. Clin Transpl. 2006;241–53.
15.
Zurück zum Zitat El-Awar N, Lee J, Terasaki PI. HLA antibody identification with single antigen beads compared to conventional methods. Hum Immunol. 2005;66:989–97.PubMedCrossRef El-Awar N, Lee J, Terasaki PI. HLA antibody identification with single antigen beads compared to conventional methods. Hum Immunol. 2005;66:989–97.PubMedCrossRef
16.
Zurück zum Zitat Arnold ML, Zacher T, Dechant M, Kalden JR, Doxiadis II, Spriewald BM. Detection and specification of noncomplement binding anti-HLA alloantibodies. Hum Immunol. 2004;65:1288–96.PubMedCrossRef Arnold ML, Zacher T, Dechant M, Kalden JR, Doxiadis II, Spriewald BM. Detection and specification of noncomplement binding anti-HLA alloantibodies. Hum Immunol. 2004;65:1288–96.PubMedCrossRef
17.
Zurück zum Zitat Zeevi A, Girnita A, Duquesnoy R. HLA antibody analysis: sensitivity, specificity, and clinical significance in solid organ transplantation. Immunol Res. 2006;36:255–64.PubMedCrossRef Zeevi A, Girnita A, Duquesnoy R. HLA antibody analysis: sensitivity, specificity, and clinical significance in solid organ transplantation. Immunol Res. 2006;36:255–64.PubMedCrossRef
18.
Zurück zum Zitat Zachary AA, Klingman L, Thorne N, Smerglia AR, Teresi GA. Variations of the lymphocytotoxicity test. An evaluation of sensitivity and specificity. Transplantation. 1995;60:498–503.PubMedCrossRef Zachary AA, Klingman L, Thorne N, Smerglia AR, Teresi GA. Variations of the lymphocytotoxicity test. An evaluation of sensitivity and specificity. Transplantation. 1995;60:498–503.PubMedCrossRef
19.
Zurück zum Zitat Tait BD. Solid phase assays for HLA antibody detection in clinical transplantation. Curr Opin Immunol. 2009;21:573–7.PubMedCrossRef Tait BD. Solid phase assays for HLA antibody detection in clinical transplantation. Curr Opin Immunol. 2009;21:573–7.PubMedCrossRef
20.
Zurück zum Zitat Tait BD, Hudson F, Cantwell L, Brewin G, Holdsworth R, Bennett G, et al. Review article: luminex technology for HLA antibody detection in organ transplantation. Nephrology (Carlton). 2009;14:247–54.CrossRef Tait BD, Hudson F, Cantwell L, Brewin G, Holdsworth R, Bennett G, et al. Review article: luminex technology for HLA antibody detection in organ transplantation. Nephrology (Carlton). 2009;14:247–54.CrossRef
21.
Zurück zum Zitat Pei R, Wang G, Tarsitani C, Rojo S, Chen T, Takemura S, et al. Simultaneous HLA Class I and Class II antibodies screening with flow cytometry. Hum Immunol. 1998;59:313–22.PubMedCrossRef Pei R, Wang G, Tarsitani C, Rojo S, Chen T, Takemura S, et al. Simultaneous HLA Class I and Class II antibodies screening with flow cytometry. Hum Immunol. 1998;59:313–22.PubMedCrossRef
22.
Zurück zum Zitat Pei R, Lee JH, Shih NJ, Chen M, Terasaki PI. Single human leukocyte antigen flow cytometry beads for accurate identification of human leukocyte antigen antibody specificities. Transplantation. 2003;75:43–9.PubMedCrossRef Pei R, Lee JH, Shih NJ, Chen M, Terasaki PI. Single human leukocyte antigen flow cytometry beads for accurate identification of human leukocyte antigen antibody specificities. Transplantation. 2003;75:43–9.PubMedCrossRef
23.
Zurück zum Zitat Van den Berg-Loonen EM, Billen EV, Voorter CE, van Heurn LW, Claas FH, van Hooff JP, et al. Clinical relevance of pretransplant donor-directed antibodies detected by single antigen beads in highly sensitized renal transplant patients. Transplantation. 2008;85:1086–90.PubMedCrossRef Van den Berg-Loonen EM, Billen EV, Voorter CE, van Heurn LW, Claas FH, van Hooff JP, et al. Clinical relevance of pretransplant donor-directed antibodies detected by single antigen beads in highly sensitized renal transplant patients. Transplantation. 2008;85:1086–90.PubMedCrossRef
24.
Zurück zum Zitat Cecka JM. Current methodologies for detecting sensitization to HLA antigens. Curr Opin Organ Transpl. 2011;16:398–403.CrossRef Cecka JM. Current methodologies for detecting sensitization to HLA antigens. Curr Opin Organ Transpl. 2011;16:398–403.CrossRef
25.
Zurück zum Zitat Cai J, Terasaki PI. Post-transplantation antibody monitoring and HLA antibody epitope identification. Curr Opin Immunol. 2008;20:602–6.PubMedCrossRef Cai J, Terasaki PI. Post-transplantation antibody monitoring and HLA antibody epitope identification. Curr Opin Immunol. 2008;20:602–6.PubMedCrossRef
26.
Zurück zum Zitat El-Awar N, Terasaki PI, Cai J, Deng CT, Ozawa M, Nguyen A. Epitopes of the HLA-A, B, C, DR, DQ and MICA antigens. Clin Transpl. 2009;295–321. El-Awar N, Terasaki PI, Cai J, Deng CT, Ozawa M, Nguyen A. Epitopes of the HLA-A, B, C, DR, DQ and MICA antigens. Clin Transpl. 2009;295–321.
27.
Zurück zum Zitat Deng CT, El-Awar N, Ozawa M, Cai J, Lachmann N, Terasaki PI. Human leukocyte antigen class II DQ alpha and beta epitopes identified from sera of kidney allograft recipients. Transplantation. 2008;86:452–9.PubMedCrossRef Deng CT, El-Awar N, Ozawa M, Cai J, Lachmann N, Terasaki PI. Human leukocyte antigen class II DQ alpha and beta epitopes identified from sera of kidney allograft recipients. Transplantation. 2008;86:452–9.PubMedCrossRef
28.
Zurück zum Zitat Qiu J, Cai J, Terasaki PI, El-Awar N, Lee JH. Detection of antibodies to HLA-DP in renal transplant recipients using single antigen beads. Transplantation. 2005;80:1511–3.PubMedCrossRef Qiu J, Cai J, Terasaki PI, El-Awar N, Lee JH. Detection of antibodies to HLA-DP in renal transplant recipients using single antigen beads. Transplantation. 2005;80:1511–3.PubMedCrossRef
29.
Zurück zum Zitat Singh P, Colombe BW, Francos GC, Martinez Cantarin MP, Frank AM. Acute humoral rejection in a zero mismatch deceased donor renal transplant due to an antibody to an HLA-DP alpha. Transplantation. 2010;90:220–1. Singh P, Colombe BW, Francos GC, Martinez Cantarin MP, Frank AM. Acute humoral rejection in a zero mismatch deceased donor renal transplant due to an antibody to an HLA-DP alpha. Transplantation. 2010;90:220–1.
30.
Zurück zum Zitat Gilbert M, Paul S, Perrat G, Giannoli C. Pouteil Noble C, Morelon E et al. Impact of pretransplant human leukocyte antigen-C and -DP antibodies on kidney graft outcome. Transpl Proc. 2011;43:3412–4.CrossRef Gilbert M, Paul S, Perrat G, Giannoli C. Pouteil Noble C, Morelon E et al. Impact of pretransplant human leukocyte antigen-C and -DP antibodies on kidney graft outcome. Transpl Proc. 2011;43:3412–4.CrossRef
31.
Zurück zum Zitat Vaidya S, Hilson B, Sheldon S, Cano P, Fernandez-Vina M. DP reactive antibody in a zero mismatch renal transplant pair. Hum Immunol. 2007;68:947–9.PubMedCrossRef Vaidya S, Hilson B, Sheldon S, Cano P, Fernandez-Vina M. DP reactive antibody in a zero mismatch renal transplant pair. Hum Immunol. 2007;68:947–9.PubMedCrossRef
32.
Zurück zum Zitat Thaunat O, Hanf W, Dubois V, McGregor B, Perrat G, Chauvet C, et al. Chronic humoral rejection mediated by anti-HLA-DP alloantibodies: insights into the role of epitope sharing in donor-specific and non-donor specific alloantibodies generation. Transpl Immunol. 2009;20:209–11.PubMedCrossRef Thaunat O, Hanf W, Dubois V, McGregor B, Perrat G, Chauvet C, et al. Chronic humoral rejection mediated by anti-HLA-DP alloantibodies: insights into the role of epitope sharing in donor-specific and non-donor specific alloantibodies generation. Transpl Immunol. 2009;20:209–11.PubMedCrossRef
33.
Zurück zum Zitat Billen EV, Christiaans MH, Doxiadis II, Voorter CE, van den Berg-Loonen EM. HLA-DP antibodies before and after renal transplantation. Tissue Antigens. 2010;75:278–85.PubMedCrossRef Billen EV, Christiaans MH, Doxiadis II, Voorter CE, van den Berg-Loonen EM. HLA-DP antibodies before and after renal transplantation. Tissue Antigens. 2010;75:278–85.PubMedCrossRef
34.
Zurück zum Zitat Duquesnoy RJ, Marrari M. Detection of antibodies against HLA-C epitopes in patients with rejected kidney transplants. Transpl Immunol. 2011;24:164–71.PubMedCrossRef Duquesnoy RJ, Marrari M. Detection of antibodies against HLA-C epitopes in patients with rejected kidney transplants. Transpl Immunol. 2011;24:164–71.PubMedCrossRef
35.
Zurück zum Zitat Barabanova Y, Ramon DS, Tambur AR. Antibodies against HLA-DQ alpha-chain and their role in organ transplantation. Hum Immunol. 2009;70:410–2.PubMedCrossRef Barabanova Y, Ramon DS, Tambur AR. Antibodies against HLA-DQ alpha-chain and their role in organ transplantation. Hum Immunol. 2009;70:410–2.PubMedCrossRef
36.
Zurück zum Zitat Bryan CF, Luger AM, Smith JL, Warady BA, Wakefield M, Schadde E, et al. Sharing kidneys across donor-service area boundaries with sensitized candidates can be influenced by HLA C. Clin Transpl. 2010;24:56–61.CrossRef Bryan CF, Luger AM, Smith JL, Warady BA, Wakefield M, Schadde E, et al. Sharing kidneys across donor-service area boundaries with sensitized candidates can be influenced by HLA C. Clin Transpl. 2010;24:56–61.CrossRef
37.
Zurück zum Zitat Proust B, Kennel A, Ladrière M, Kessler M, Perrier P. Unexpected anti-HLA-DR and -DQ alloantibodies after nephrectomy of an HLA-DR and -DQ identical first renal transplant. Transpl Immunol. 2009;21:166–8.PubMedCrossRef Proust B, Kennel A, Ladrière M, Kessler M, Perrier P. Unexpected anti-HLA-DR and -DQ alloantibodies after nephrectomy of an HLA-DR and -DQ identical first renal transplant. Transpl Immunol. 2009;21:166–8.PubMedCrossRef
38.
Zurück zum Zitat Muro M, González-Soriano MJ, Salgado G, López R, Boix F, López M, et al. Specific “intra-allele” and “intra-broad antigen” human leukocyte antigen alloantibodies in kidney graft transplantation. Hum Immunol. 2010;71:857–60.PubMedCrossRef Muro M, González-Soriano MJ, Salgado G, López R, Boix F, López M, et al. Specific “intra-allele” and “intra-broad antigen” human leukocyte antigen alloantibodies in kidney graft transplantation. Hum Immunol. 2010;71:857–60.PubMedCrossRef
39.
Zurück zum Zitat Cox ST, Stephens HA, Fernando R, Karasu A, Harber M, Howie AJ, et al. Major histocompatibility complex class I-related chain A allele mismatching, antibodies, and rejection in renal transplantation. Hum Immunol. 2011;72:827–34.PubMedCrossRef Cox ST, Stephens HA, Fernando R, Karasu A, Harber M, Howie AJ, et al. Major histocompatibility complex class I-related chain A allele mismatching, antibodies, and rejection in renal transplantation. Hum Immunol. 2011;72:827–34.PubMedCrossRef
40.
Zurück zum Zitat Narayan S, Tsai EW, Zhang Q, Wallace WD, Reed EF, Ettenger RB. Acute rejection associated with donor-specific anti-MICA antibody in a highly sensitized pediatric renal transplant recipient. Pediatr Transpl. 2011;15:E1–7.CrossRef Narayan S, Tsai EW, Zhang Q, Wallace WD, Reed EF, Ettenger RB. Acute rejection associated with donor-specific anti-MICA antibody in a highly sensitized pediatric renal transplant recipient. Pediatr Transpl. 2011;15:E1–7.CrossRef
41.
Zurück zum Zitat Zachary AA, Montgomery RA, Leffell MS. Defining unacceptable HLA antigens. Curr Opin Organ Transpl. 2008;13:405–10.CrossRef Zachary AA, Montgomery RA, Leffell MS. Defining unacceptable HLA antigens. Curr Opin Organ Transpl. 2008;13:405–10.CrossRef
42.
Zurück zum Zitat Zachary AA, Sholander JT, Houp JA, Leffell MS. Using real data for a virtualcrossmatch. Hum Immunol. 2009;70:574–9.PubMedCrossRef Zachary AA, Sholander JT, Houp JA, Leffell MS. Using real data for a virtualcrossmatch. Hum Immunol. 2009;70:574–9.PubMedCrossRef
43.
Zurück zum Zitat Batal I, Zeevi A, Lunz JG 3rd, Aggarwal N, Shapiro R, Randhawa P, et al. Antihuman leukocyte antigen–specific antibody strength determined by complement-dependent or solid-phase assays can predict positive donor-specific crossmatches. Arch Pathol Lab Med. 2010;134:1534–40.PubMed Batal I, Zeevi A, Lunz JG 3rd, Aggarwal N, Shapiro R, Randhawa P, et al. Antihuman leukocyte antigen–specific antibody strength determined by complement-dependent or solid-phase assays can predict positive donor-specific crossmatches. Arch Pathol Lab Med. 2010;134:1534–40.PubMed
44.
Zurück zum Zitat Billen EV, Christiaans MH, van den Berg-Loonen EM. Clinical relevance of Luminex donor-specific crossmatches: data from 165 renal transplants. Tissue Antigens. 2009;74:205–12.PubMedCrossRef Billen EV, Christiaans MH, van den Berg-Loonen EM. Clinical relevance of Luminex donor-specific crossmatches: data from 165 renal transplants. Tissue Antigens. 2009;74:205–12.PubMedCrossRef
45.
Zurück zum Zitat Gandhi MJ, Degoey SR, Bundy K, Kremers WK, Knauer R, Pereira N, et al. Effect of pretransplant human leukocyte antigen antibodies detected by solid-phase assay on heart transplant outcomes. Transplant Proc. 2011;43(10):3840–6.PubMedCrossRef Gandhi MJ, Degoey SR, Bundy K, Kremers WK, Knauer R, Pereira N, et al. Effect of pretransplant human leukocyte antigen antibodies detected by solid-phase assay on heart transplant outcomes. Transplant Proc. 2011;43(10):3840–6.PubMedCrossRef
46.
Zurück zum Zitat Billen EV, Voorter CE, Christiaans MH, van den Berg-Loonen EM. Luminex donor-specific crossmatches. Tissue Antigens. 2008;71:507–13.PubMedCrossRef Billen EV, Voorter CE, Christiaans MH, van den Berg-Loonen EM. Luminex donor-specific crossmatches. Tissue Antigens. 2008;71:507–13.PubMedCrossRef
47.
Zurück zum Zitat Caro-Oleas JL, González-Escribano MF, Toro-Llamas S, Acevedo MJ, Martinez-Bravo MJ, Aguilera I, et al. Donor-specific antibody detection: comparison of single antigen assay and Luminex crossmatches. Tissue Antigens. 2010;76:398–403.PubMedCrossRef Caro-Oleas JL, González-Escribano MF, Toro-Llamas S, Acevedo MJ, Martinez-Bravo MJ, Aguilera I, et al. Donor-specific antibody detection: comparison of single antigen assay and Luminex crossmatches. Tissue Antigens. 2010;76:398–403.PubMedCrossRef
48.
Zurück zum Zitat Caro-Oleas JL, González-Escribano MF, González-Roncero FM, Acevedo-Calado MJ,Cabello-Chaves V, Gentil-Govantes MA et al. Clinical relevance of HLA donor-specific antibodies detected by single antigen assay in kidney transplantation. Nephrol Dial Transpl. 2011 [Epub ahead of print]. Caro-Oleas JL, González-Escribano MF, González-Roncero FM, Acevedo-Calado MJ,Cabello-Chaves V, Gentil-Govantes MA et al. Clinical relevance of HLA donor-specific antibodies detected by single antigen assay in kidney transplantation. Nephrol Dial Transpl. 2011 [Epub ahead of print].
49.
Zurück zum Zitat Riethmüller S, Ferrari-Lacraz S, Müller MK, Raptis DA, Hadaya K, Rüsi B, et al. Donor-specific antibody levels and three generations of crossmatches to predict antibody-mediated rejection in kidney transplantation. Transplantation. 2010;90:160–7.PubMedCrossRef Riethmüller S, Ferrari-Lacraz S, Müller MK, Raptis DA, Hadaya K, Rüsi B, et al. Donor-specific antibody levels and three generations of crossmatches to predict antibody-mediated rejection in kidney transplantation. Transplantation. 2010;90:160–7.PubMedCrossRef
50.
Zurück zum Zitat Leffell MS, Zachary AA. Antiallograft antibodies: relevance, detection, and monitoring. Curr Opin Organ Transpl. 2010;15:2–7.CrossRef Leffell MS, Zachary AA. Antiallograft antibodies: relevance, detection, and monitoring. Curr Opin Organ Transpl. 2010;15:2–7.CrossRef
51.
Zurück zum Zitat Minucci PB, Grimaldi V, Casamassimi A, Cacciatore F, Sommese L, Picascia A, et al. Methodologies for Anti-HLA antibody screening in patients awaiting kidney transplant: a comparative study. Exp Clin Transpl. 2011;9(6):381–6. Minucci PB, Grimaldi V, Casamassimi A, Cacciatore F, Sommese L, Picascia A, et al. Methodologies for Anti-HLA antibody screening in patients awaiting kidney transplant: a comparative study. Exp Clin Transpl. 2011;9(6):381–6.
52.
Zurück zum Zitat Poli F, Cardillo M, Scalamogna M. Clinical relevance of human leukocyte antigen antibodies in kidney transplantation from deceased donors: the North Italy Transplant program approach. Hum Immunol. 2009;70:631–5.PubMedCrossRef Poli F, Cardillo M, Scalamogna M. Clinical relevance of human leukocyte antigen antibodies in kidney transplantation from deceased donors: the North Italy Transplant program approach. Hum Immunol. 2009;70:631–5.PubMedCrossRef
53.
Zurück zum Zitat Gupta A, Sinnott P. Clinical relevance of pretransplant human leukocyte antigen donor-specific antibodies in renal patients waiting for a transplant: a risk factor. Hum Immunol. 2009;70:618–22.PubMedCrossRef Gupta A, Sinnott P. Clinical relevance of pretransplant human leukocyte antigen donor-specific antibodies in renal patients waiting for a transplant: a risk factor. Hum Immunol. 2009;70:618–22.PubMedCrossRef
54.
Zurück zum Zitat Gupta A, Iveson V, Varagunam M, Bodger S, Sinnott P, Thuraisingham RC. Pretransplant donor-specific antibodies in cytotoxic negative crossmatch kidney transplants: are they relevant? Transplantation. 2008;85:1200–4.PubMedCrossRef Gupta A, Iveson V, Varagunam M, Bodger S, Sinnott P, Thuraisingham RC. Pretransplant donor-specific antibodies in cytotoxic negative crossmatch kidney transplants: are they relevant? Transplantation. 2008;85:1200–4.PubMedCrossRef
55.
Zurück zum Zitat Eng HS, Bennett G, Bardy P, Coghlan P, Russ GR, Coates PT. Clinical significance of anti-HLA antibodies detected by Luminex: enhancing the interpretation of CDC-BXM and important post-transplantation monitoring tools. Hum Immunol. 2009;70:595–9.PubMedCrossRef Eng HS, Bennett G, Bardy P, Coghlan P, Russ GR, Coates PT. Clinical significance of anti-HLA antibodies detected by Luminex: enhancing the interpretation of CDC-BXM and important post-transplantation monitoring tools. Hum Immunol. 2009;70:595–9.PubMedCrossRef
56.
Zurück zum Zitat Aubert V, Venetz JP, Pantaleo G, Pascual M. Low levels of human leukocyte antigen donor-specific antibodies detected by solid phase assay before transplantation are frequently clinically irrelevant. Hum Immunol. 2009;70:580–3.PubMedCrossRef Aubert V, Venetz JP, Pantaleo G, Pascual M. Low levels of human leukocyte antigen donor-specific antibodies detected by solid phase assay before transplantation are frequently clinically irrelevant. Hum Immunol. 2009;70:580–3.PubMedCrossRef
57.
Zurück zum Zitat Opelz G, Claas FH. Which human leukocyte antigen antibodies are really clinically relevant? Hum Immunol. 2009;70:561–2.PubMedCrossRef Opelz G, Claas FH. Which human leukocyte antigen antibodies are really clinically relevant? Hum Immunol. 2009;70:561–2.PubMedCrossRef
58.
Zurück zum Zitat Zoet YM, Brand-Schaaf SH, Roelen DL, Mulder A, Claas FH, Doxiadis II. Challenging the golden standard in defining donor-specific antibodies: does the solid phase assay meet the expectations? Tissue Antigens. 2011;77:225–8.PubMedCrossRef Zoet YM, Brand-Schaaf SH, Roelen DL, Mulder A, Claas FH, Doxiadis II. Challenging the golden standard in defining donor-specific antibodies: does the solid phase assay meet the expectations? Tissue Antigens. 2011;77:225–8.PubMedCrossRef
59.
Zurück zum Zitat Vlad G, Ho EK, Vasilescu ER, Colovai AI, Stokes MB, Markowitz GS, et al. Relevance of different antibody detection methods for the prediction of antibody-mediated rejection and deceased-donor kidney allograft survival. Hum Immunol. 2009;70:589–94.PubMedCrossRef Vlad G, Ho EK, Vasilescu ER, Colovai AI, Stokes MB, Markowitz GS, et al. Relevance of different antibody detection methods for the prediction of antibody-mediated rejection and deceased-donor kidney allograft survival. Hum Immunol. 2009;70:589–94.PubMedCrossRef
60.
Zurück zum Zitat Pereira S, Perkins S, Lee JH, Shumway W, LeFor W, Lopez-Cepero M et al. Donor-specific antibody against denatured HLA-A1: clinically nonsignificant? Hum Immunol. 2011;72:492–8. Pereira S, Perkins S, Lee JH, Shumway W, LeFor W, Lopez-Cepero M et al. Donor-specific antibody against denatured HLA-A1: clinically nonsignificant? Hum Immunol. 2011;72:492–8.
61.
Zurück zum Zitat Taylor CJ, Kosmoliaptsis V, Summers DM, Bradley JA. Back to the future: application of contemporary technology to long-standing questions about the clinical relevance of human leukocyte antigen-specific alloantibodies in renal transplantation. Hum Immunol. 2009;70:563–8.PubMedCrossRef Taylor CJ, Kosmoliaptsis V, Summers DM, Bradley JA. Back to the future: application of contemporary technology to long-standing questions about the clinical relevance of human leukocyte antigen-specific alloantibodies in renal transplantation. Hum Immunol. 2009;70:563–8.PubMedCrossRef
62.
Zurück zum Zitat Mizutani K, Terasaki P, Hamdani E, Esquenazi V, Rosen A, Miller J, et al. The importance of anti-HLA-specific antibody strength in monitoring kidney transplant patients. Am J Transpl. 2007;7:1027–31.CrossRef Mizutani K, Terasaki P, Hamdani E, Esquenazi V, Rosen A, Miller J, et al. The importance of anti-HLA-specific antibody strength in monitoring kidney transplant patients. Am J Transpl. 2007;7:1027–31.CrossRef
63.
Zurück zum Zitat Vaidya S, Partlow D, Susskind B, Noor M, Barnes T, Gugliuzza K. Prediction of crossmatch outcome of highly sensitized patients by single and/or multiple antigen bead luminex assay. Transplantation. 2006;82:1524–8.PubMedCrossRef Vaidya S, Partlow D, Susskind B, Noor M, Barnes T, Gugliuzza K. Prediction of crossmatch outcome of highly sensitized patients by single and/or multiple antigen bead luminex assay. Transplantation. 2006;82:1524–8.PubMedCrossRef
64.
Zurück zum Zitat Wahrmann M, Exner M, Schillinger M, Haidbauer B, Regele H, Körmöczi GF, et al. Pivotal role of complement-fixing HLA alloantibodies in presensitized kidney allograft recipients. Am J Transpl. 2006;6:1033–41.CrossRef Wahrmann M, Exner M, Schillinger M, Haidbauer B, Regele H, Körmöczi GF, et al. Pivotal role of complement-fixing HLA alloantibodies in presensitized kidney allograft recipients. Am J Transpl. 2006;6:1033–41.CrossRef
65.
Zurück zum Zitat Wahrmann M, Exner M, Haidbauer B, Schillinger M, Regele H, Körmöczi G, et al. [C4d]FlowPRA screening–a specific assay for selective detection of complement-activating anti-HLA alloantibodies. Hum Immunol. 2005;66:526–34.PubMedCrossRef Wahrmann M, Exner M, Haidbauer B, Schillinger M, Regele H, Körmöczi G, et al. [C4d]FlowPRA screening–a specific assay for selective detection of complement-activating anti-HLA alloantibodies. Hum Immunol. 2005;66:526–34.PubMedCrossRef
66.
Zurück zum Zitat Smith JD, Hamour IM, Banner NR, Rose ML. C4d fixing, luminex binding antibodies—a new tool for prediction of graft failure after heart transplantation. Am J Transpl. 2007;7:2809–15.CrossRef Smith JD, Hamour IM, Banner NR, Rose ML. C4d fixing, luminex binding antibodies—a new tool for prediction of graft failure after heart transplantation. Am J Transpl. 2007;7:2809–15.CrossRef
67.
Zurück zum Zitat Heinemann FM, Roth I, Rebmann V, Arnold ML, Witzke O, Wilde B, et al. Immunoglobulin isotype-specific characterization of anti-human leukocyte antigen antibodies eluted from explanted renal allografts. Hum Immunol. 2007;68:500–6.PubMedCrossRef Heinemann FM, Roth I, Rebmann V, Arnold ML, Witzke O, Wilde B, et al. Immunoglobulin isotype-specific characterization of anti-human leukocyte antigen antibodies eluted from explanted renal allografts. Hum Immunol. 2007;68:500–6.PubMedCrossRef
68.
Zurück zum Zitat Arnold ML, Dechant M, Doxiadis II, Spriewald BM. Prevalence and specificity of immunoglobulin G and immunoglobulin A non-complement-binding anti-HLA alloantibodies in retransplant candidates. Tissue Antigens. 2008;72:60–6.PubMedCrossRef Arnold ML, Dechant M, Doxiadis II, Spriewald BM. Prevalence and specificity of immunoglobulin G and immunoglobulin A non-complement-binding anti-HLA alloantibodies in retransplant candidates. Tissue Antigens. 2008;72:60–6.PubMedCrossRef
69.
Zurück zum Zitat Bartel G, Wahrmann M, Exner M, Regele H, Huttary N, Schillinger M, et al. In vitro detection of C4d-fixing HLA alloantibodies: associations with capillary C4d deposition in kidney allografts. Am J Transpl. 2008;8:41–9.CrossRef Bartel G, Wahrmann M, Exner M, Regele H, Huttary N, Schillinger M, et al. In vitro detection of C4d-fixing HLA alloantibodies: associations with capillary C4d deposition in kidney allografts. Am J Transpl. 2008;8:41–9.CrossRef
70.
Zurück zum Zitat Chin C, Chen G, Sequeria F, Berry G, Siehr S, Bernstein D, et al. Clinical usefulness of a novel C1q assay to detect immunoglobulin G antibodies capable of fixing complement in sensitized pediatric heart transplant patients. J Heart Lung Transpl. 2011;30:158–63.CrossRef Chin C, Chen G, Sequeria F, Berry G, Siehr S, Bernstein D, et al. Clinical usefulness of a novel C1q assay to detect immunoglobulin G antibodies capable of fixing complement in sensitized pediatric heart transplant patients. J Heart Lung Transpl. 2011;30:158–63.CrossRef
71.
Zurück zum Zitat Hönger G, Wahrmann M, Amico P, Hopfer H, Böhmig GA, Schaub S. C4d-fixing capability of low-level donor-specific HLA antibodies is not predictive for early antibody-mediated rejection. Transplantation. 2010;89:1471–5.PubMedCrossRef Hönger G, Wahrmann M, Amico P, Hopfer H, Böhmig GA, Schaub S. C4d-fixing capability of low-level donor-specific HLA antibodies is not predictive for early antibody-mediated rejection. Transplantation. 2010;89:1471–5.PubMedCrossRef
72.
Zurück zum Zitat Chen G, Sequeira F, Tyan DB. Novel C1q assay reveals a clinically relevant subset of human leukocyte antigen antibodies independent of immunoglobulin G strength on single antigen beads. Hum Immunol. 2011;72:849–58.PubMedCrossRef Chen G, Sequeira F, Tyan DB. Novel C1q assay reveals a clinically relevant subset of human leukocyte antigen antibodies independent of immunoglobulin G strength on single antigen beads. Hum Immunol. 2011;72:849–58.PubMedCrossRef
Metadaten
Titel
Luminex and antibody detection in kidney transplantation
verfasst von
Antonietta Picascia
Teresa Infante
Claudio Napoli
Publikationsdatum
01.06.2012
Verlag
Springer Japan
Erschienen in
Clinical and Experimental Nephrology / Ausgabe 3/2012
Print ISSN: 1342-1751
Elektronische ISSN: 1437-7799
DOI
https://doi.org/10.1007/s10157-012-0635-1

Weitere Artikel der Ausgabe 3/2012

Clinical and Experimental Nephrology 3/2012 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Auf Antibiotika verzichten? Was bei unkomplizierter Zystitis hilft

15.05.2024 Harnwegsinfektionen Nachrichten

Welche Antibiotika darf man bei unkomplizierter Zystitis verwenden und wovon sollte man die Finger lassen? Welche pflanzlichen Präparate können helfen? Was taugt der zugelassene Impfstoff? Antworten vom Koordinator der frisch überarbeiteten S3-Leitlinie, Prof. Florian Wagenlehner.

Schadet Ärger den Gefäßen?

14.05.2024 Arteriosklerose Nachrichten

In einer Studie aus New York wirkte sich Ärger kurzfristig deutlich negativ auf die Endothelfunktion gesunder Probanden aus. Möglicherweise hat dies Einfluss auf die kardiovaskuläre Gesundheit.

Intervallfasten zur Regeneration des Herzmuskels?

14.05.2024 Herzinfarkt Nachrichten

Die Nahrungsaufnahme auf wenige Stunden am Tag zu beschränken, hat möglicherweise einen günstigen Einfluss auf die Prognose nach akutem ST-Hebungsinfarkt. Darauf deutet eine Studie an der Uniklinik in Halle an der Saale hin.

Klimaschutz beginnt bei der Wahl des Inhalators

14.05.2024 Klimawandel Podcast

Auch kleine Entscheidungen im Alltag einer Praxis können einen großen Beitrag zum Klimaschutz leisten. Die neue Leitlinie zur "klimabewussten Verordnung von Inhalativa" geht mit gutem Beispiel voran, denn der Wechsel vom klimaschädlichen Dosieraerosol zum Pulverinhalator spart viele Tonnen CO2. Leitlinienautor PD Dr. Guido Schmiemann erklärt, warum nicht nur die Umwelt, sondern auch Patientinnen und Patienten davon profitieren.

Zeitschrift für Allgemeinmedizin, DEGAM

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.