MDCT of the proximal anastomoses created by nitinol implants in coronary artery bypass grafting: a retrospective two-observer evaluation

verfasst von: M. Fawad Khan, Christopher Herzog, Kai Landenberger, Sven Martens, Adel Maataoui, Hanns Ackermann, Markus Dietrich, Anton Moritz, Thomas J. Vogl

Erschienen in: European Radiology | Ausgabe 2/2005

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to investigate the proximal anastomosis of CABG grafts created by a nitinol aortic connector. After receiving CABG, 33 patients underwent CT examination of the heart. On the same patients, CT was performed on postoperative day 5 (4-row CT, group A) and again 1 year thereafter (16-row CT, group B). Twenty-three ACVB to RCX and 27 ACVB to RCA grafts were included. Every anastomosis was reviewed under different reformations (MIP, MPR and VRT). Interobserver correlation was determined. Five days postoperatively, 48/50 anastomoses were classified as patent. One year postoperatively, 42/50 anastomoses were classified as patent. In both groups, the aortic connector could be visualized with good quality: 1.82±1.10 (group A) and 1.93±1.22 (group B) for ACVB to RCA, similar results for ACVB to RCX grafts (MPR). Image quality at the aortic connector site did not display a significant difference for any reformation between groups (P>0.05). Within groups, MPR displayed better visualization than MIP and VRT (P<0.05). In the presence of metal implants, CT provides reliable data in evaluation of the proximal anastomosis. Sixteen-row CT does not bring a significant benefit to image quality. MPR displayed the best visualization within both groups.
Literatur
1.
Zurück zum Zitat von Smekal A, Lachat M, Wildermuth S, Khan G, Turina M, Marincek B (2000) Proximal anastomoses of aortocoronary bypasses. Evaluation with ECG-triggered single-slice computerized tomography. Radiologe 40:130–135CrossRefPubMed von Smekal A, Lachat M, Wildermuth S, Khan G, Turina M, Marincek B (2000) Proximal anastomoses of aortocoronary bypasses. Evaluation with ECG-triggered single-slice computerized tomography. Radiologe 40:130–135CrossRefPubMed
2.
Zurück zum Zitat Bruckenberger E (2001) Bericht der Arbeitsgruppe Krankenhauswesen der Arbeitsgemeinschaft der obersten Landesgesundheitsbehörden der Länder (AOLG). Herzbericht 14:2001 Bruckenberger E (2001) Bericht der Arbeitsgruppe Krankenhauswesen der Arbeitsgemeinschaft der obersten Landesgesundheitsbehörden der Länder (AOLG). Herzbericht 14:2001
3.
Zurück zum Zitat Tan ES, van der Meer J, Jan de Kam P et al (1999) Worse clinical outcome but similar graft patency in women versus men one year after coronary artery bypass graft surgery owing to an excess of exposed risk factors in women. CABADAS. Research Group of the Interuniversity Cardiology Institute of The Netherlands. Coronary Artery Bypass graft occlusion by Aspirin, Dipyridamole and Acenocoumarol/phenoprocoumon Study. J Am Coll Cardiol 34:1760–1768CrossRefPubMed Tan ES, van der Meer J, Jan de Kam P et al (1999) Worse clinical outcome but similar graft patency in women versus men one year after coronary artery bypass graft surgery owing to an excess of exposed risk factors in women. CABADAS. Research Group of the Interuniversity Cardiology Institute of The Netherlands. Coronary Artery Bypass graft occlusion by Aspirin, Dipyridamole and Acenocoumarol/phenoprocoumon Study. J Am Coll Cardiol 34:1760–1768CrossRefPubMed
4.
Zurück zum Zitat Martens S, Herzog C, Dietrich M, Doss M, Wimmer-Greinecker G, Moritz A (2003) Ultrafast computed tomography for quality control of automated proximal anastomoses. Heart Surg Forum 6:E170–E173PubMed Martens S, Herzog C, Dietrich M, Doss M, Wimmer-Greinecker G, Moritz A (2003) Ultrafast computed tomography for quality control of automated proximal anastomoses. Heart Surg Forum 6:E170–E173PubMed
5.
Zurück zum Zitat Stein H, Ikeda M, Jacobs S et al (2003) Telemanipulatory application of a magnetic coupler on the beating heart with the daVinci surgical system. Biomed Tech (Berl) 48:230–234 Stein H, Ikeda M, Jacobs S et al (2003) Telemanipulatory application of a magnetic coupler on the beating heart with the daVinci surgical system. Biomed Tech (Berl) 48:230–234
6.
Zurück zum Zitat Dogan S, Aybek T, Khan MF et al (2002) Computer-enhanced telemanipulation enables a variety of totally endoscopic cardiac procedures. Thorac Cardiovasc Surg 50:281–286CrossRefPubMed Dogan S, Aybek T, Khan MF et al (2002) Computer-enhanced telemanipulation enables a variety of totally endoscopic cardiac procedures. Thorac Cardiovasc Surg 50:281–286CrossRefPubMed
7.
Zurück zum Zitat Maintz D, Juergens KU, Wichter T, Grude M, Heindel W, Fischbach R (2003) Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation. Eur Radiol 13:830–835PubMed Maintz D, Juergens KU, Wichter T, Grude M, Heindel W, Fischbach R (2003) Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation. Eur Radiol 13:830–835PubMed
8.
Zurück zum Zitat Knollmann FD, Moller J, Gebert A, Bethge C, Felix R (2004) Assessment of coronary artery stent patency by electron-beam CT. Eur Radiol 14:1341–1347CrossRefPubMed Knollmann FD, Moller J, Gebert A, Bethge C, Felix R (2004) Assessment of coronary artery stent patency by electron-beam CT. Eur Radiol 14:1341–1347CrossRefPubMed
9.
Zurück zum Zitat Amano Y, Ishihara M, Hayashi H et al (1999) Metallic artifacts of coronary and iliac arteries stents in MR angiography and contrast-enhanced CT. Clin Imaging 23:85–89CrossRefPubMed Amano Y, Ishihara M, Hayashi H et al (1999) Metallic artifacts of coronary and iliac arteries stents in MR angiography and contrast-enhanced CT. Clin Imaging 23:85–89CrossRefPubMed
10.
Zurück zum Zitat Sutherland CJ, Gayou DE (1996) Artifacts and thresholding in X-ray CT of a cortical bone and titanium composite. J Comput Assist Tomogr 20:496–503CrossRefPubMed Sutherland CJ, Gayou DE (1996) Artifacts and thresholding in X-ray CT of a cortical bone and titanium composite. J Comput Assist Tomogr 20:496–503CrossRefPubMed
11.
Zurück zum Zitat Rodenwaldt J (2003) Multislice computed tomography of the coronary arteries. Eur Radiol 13:748–757PubMed Rodenwaldt J (2003) Multislice computed tomography of the coronary arteries. Eur Radiol 13:748–757PubMed
12.
Zurück zum Zitat Fleischmann D (2003) High-concentration contrast media in MDCT angiography: principles and rationale. Eur Radiol 13(Suppl 3):39–43 Fleischmann D (2003) High-concentration contrast media in MDCT angiography: principles and rationale. Eur Radiol 13(Suppl 3):39–43
13.
Zurück zum Zitat Flohr T, Ohnesorge B (2001) Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923CrossRefPubMed Flohr T, Ohnesorge B (2001) Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923CrossRefPubMed
14.
15.
Zurück zum Zitat Herzog C, Dogan S, Diebold T et al (2003) Multi-detector row CT versus coronary angiography: preoperative evaluation before totally endoscopic coronary artery bypass grafting. Radiology 229:200–208PubMed Herzog C, Dogan S, Diebold T et al (2003) Multi-detector row CT versus coronary angiography: preoperative evaluation before totally endoscopic coronary artery bypass grafting. Radiology 229:200–208PubMed
16.
Zurück zum Zitat Achenbach S, Ropers D, Holle J, Muschiol G, Daniel WG, Moshage W (2000) In-plane coronary arterial motion velocity: measurement with electron-beam CT. Radiology 216:457–463PubMed Achenbach S, Ropers D, Holle J, Muschiol G, Daniel WG, Moshage W (2000) In-plane coronary arterial motion velocity: measurement with electron-beam CT. Radiology 216:457–463PubMed
17.
Zurück zum Zitat Hong C, Becker CR, Huber A et al (2001) ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 220:712–717PubMed Hong C, Becker CR, Huber A et al (2001) ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 220:712–717PubMed
18.
Zurück zum Zitat Kopp AF, Ohnesorge B, Flohr T et al (2000) Cardiac multidetector-row CT: first clinical results of retrospectively ECG-gated spiral with optimized temporal and spatial resolution. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 172:429–435CrossRefPubMed Kopp AF, Ohnesorge B, Flohr T et al (2000) Cardiac multidetector-row CT: first clinical results of retrospectively ECG-gated spiral with optimized temporal and spatial resolution. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 172:429–435CrossRefPubMed
19.
Zurück zum Zitat Georg C, Kopp A, Schroder S et al (2001) Optimizing image reconstruction timing for the RR interval in imaging coronary arteries with multi-slice computerized tomography. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:536–541CrossRefPubMed Georg C, Kopp A, Schroder S et al (2001) Optimizing image reconstruction timing for the RR interval in imaging coronary arteries with multi-slice computerized tomography. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:536–541CrossRefPubMed
20.
Zurück zum Zitat Enzweiler CN, Kivelitz DE, Wiese TH et al (2000) Coronary artery bypass grafts: improved electron-beam tomography by prolonging breath holds with preoxygenation. Radiology 217:278–283PubMed Enzweiler CN, Kivelitz DE, Wiese TH et al (2000) Coronary artery bypass grafts: improved electron-beam tomography by prolonging breath holds with preoxygenation. Radiology 217:278–283PubMed
21.
Zurück zum Zitat Carrel TP, Eckstein FS, Englberger L, Windecker S, Meier B (2003) Pitfalls and key lessons with the symmetry proximal anastomotic device in coronary artery bypass surgery. Ann Thorac Surg 75:1434–1436CrossRefPubMed Carrel TP, Eckstein FS, Englberger L, Windecker S, Meier B (2003) Pitfalls and key lessons with the symmetry proximal anastomotic device in coronary artery bypass surgery. Ann Thorac Surg 75:1434–1436CrossRefPubMed
22.
Zurück zum Zitat Fitzgibbon GM, Kafka HP, Leach AJ, Keon WJ, Hooper GD, Burton JR (1996) Coronary bypass graft fate and patient outcome: angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years. J Am Coll Cardiol 28:616–626CrossRefPubMed Fitzgibbon GM, Kafka HP, Leach AJ, Keon WJ, Hooper GD, Burton JR (1996) Coronary bypass graft fate and patient outcome: angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years. J Am Coll Cardiol 28:616–626CrossRefPubMed
23.
Zurück zum Zitat Nieman K, Pattynama PM, Rensing BJ, Van Geuns RJ, De Feyter PJ (2003) Evaluation of patients after coronary artery bypass surgery: CT angiographic assessment of grafts and coronary arteries. Radiology 229:749–756PubMed Nieman K, Pattynama PM, Rensing BJ, Van Geuns RJ, De Feyter PJ (2003) Evaluation of patients after coronary artery bypass surgery: CT angiographic assessment of grafts and coronary arteries. Radiology 229:749–756PubMed
Metadaten
Titel
MDCT of the proximal anastomoses created by nitinol implants in coronary artery bypass grafting: a retrospective two-observer evaluation
verfasst von
M. Fawad Khan
Christopher Herzog
Kai Landenberger
Sven Martens
Adel Maataoui
Hanns Ackermann
Markus Dietrich
Anton Moritz
Thomas J. Vogl
Publikationsdatum
01.02.2005
Erschienen in
European Radiology / Ausgabe 2/2005
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2542-7

Weitere Artikel der Ausgabe 2/2005

European Radiology 2/2005 Zur Ausgabe

Letter to the Editor

The fibrocartilage sesamoid

Letter to the Editor

The fibrocartilage sesamoid

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.