Abstract

This is a rare case report of a foreign metallic body found in the middle ear. During the use of an electric welding by a metalworker, a glowing drop of dissolved metal overrun, burning the skin of his external auditory meatus, perforated the tympanic membrane and finally was implanted around the ossicles as a foreign body. Due to difficulty of the physical examination and the moderate symptoms (hearing loss and sense of fullness), the foreign body was detected six months after the incident, by CT scanning and it was removed by a transcanal approach under general anesthesia. A successful ossiculoplasty-tympanoplasty was followed four weeks later.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​1746-160X-3-23) contains supplementary material, which is available to authorized users.

Background

Foreign bodies of the external ear canal are relatively common in medicine. They have been usually reported in children. On the contrary, foreign bodies in the middle ear are rare. They usually are found as a result of a violent perforation of the tympanic membrane and transfer of the foreign body through the external auditory canal to the middle ear space. Incidents with welding bead injuries are not common in welders in comparison with eye injuries. Nevertheless, it is recommended to wear earplugs for protection. There are some publications available, which describe such incidents. [13]

Case presentation

A 36-year-old metalworker presented at the emergency department with severe otalgia and bleeding from his right ear. He referred that he had an occupational accident when he was operating an electric welding, above his head; a glowing metallic drop of liquified metal was fallen in his right external meatus.
On inspection, the entrance of the external auditory canal was obstructed by massive edema while severe skin erythema with some blood clots were also revealed. Otomicroscopy of the external auditory meatus and eardrum were unfeasible because of the severe obstruction and sharp pain. The tuning forks tests were compatible with conductive hearing loss on the right side. No sensation of vertigo was reported. The rest of head and neck examination was unremarkable. Lesions were treated as severe burn. That included broad-spectrum systemic antibiotics, local applications of antiseptic solutions and creams, analgesics and corticosteroids orally. Three months later, the external auditory meatus appeared dry, atrophied, with scars resulting to a relative stenosis. The tympanic membrane appeared shrunken and thickened bearing a moderate in size perforation at the pars tensa without any secretion. Patient did not complain of pain any more. He only reported a deterioration of the fullness and hearing loss.
Six months later, during a follow up visit, patient was still complaining of the same symptoms. Audiometric evaluation revealed moderate conductive hearing loss on the right ear.
The patient had undergone a CT scan, where a metallic foreign body was depicted in the middle ear cavity, wedged around the ossicles. The diameter of the foreign body was estimated about 2.2 mm (Figure 1). This small piece of metal was apparently the glowing drop, which had caused the injury few months ago.
An exploration of the middle ear and the ossicular chain under general anesthesia was deemed necessary. Using a transcanal approach, scaring tissue of the external auditory canal was removed using the CO2 laser. A fracture of malleus' manubrium was found as well as adhesions around the remnants of the manubrium, the long process of incus and the head of the stapes. The foreign body was revealed among the adhesions and was removed (Figure 2). An ossiculoplasty- tympanoplasty was followed, four weeks later. Six months after the incident, the perforation was healed and the air-bone gap was disappeared. One year later, the tympanic membrane was still whole and intact and the pure tone audiogram was normal.

Discussion

In the current literature, very few cases of foreign bodies in middle ear are reported. Syms and Nelson [4] presened 4 cases of impression-material foreign bodies in middle ear induced chronic otitis media. Shimanski [5] reported a case of silicone foreign body in the middle ear caused by auditory canal impression in hearing aid fitting. Patient was complaining of acute otalgia. Kohan et al. [6] performed a retrospective analysis of complications after hearing aid fitting and they described six cases of patients suffered from severe complications due to improper ear mold fitting, requiring surgical intervention.
Foreign bodies, particularly from metal, of the middle ear are not often reported but they can induce symptoms like hearing loss, fullness, tinnitus and vertigo. Simons and Eibling [3]described the unique finding of retained slag in the context of a persistent tympanic membrane perforation from a welding injury that occurred more than 30 years ago. Panosian et al [2]reported transtympanic facial nerve injury in welders. Similarly, facial paralysis and hearing loss is presented by Stage and Vinding [7] due to metal spark perforation of the tympanic membrane. In our case the conductive hearing loss was more severe than could be expected in accordance with the perforation's size. CT was very helpful to reveal the cause of the patient's symptoms. In the literature, it is recommended that welding bead injuries tend to heal very badly [8] and recurrent perforations after tympanoplasty are often [1]. In our case, the speedy course of the healing process after the surgical intervention was probably due to the young age of the patient and the relatively early reparation after the injury.
In conclusion a foreign metal body in the middle ear is a rare event but in welders who do not use ear plugs for protection, a penetrated metallic foreign body of the middle ear can cause severe damage. If the anamnesis and the clinical symptoms lead to the suspicion of having a metallic foreign body into the middle ear, we have to recommend X-ray or CT imaging to verify the diagnosis before surgery. Although ocular injuries from welding are more frequent, physicians have to emphasize ear protection, too.
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://​creativecommons.​org/​licenses/​by/​2.​0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
download
DOWNLOAD
print
DRUCKEN
Anhänge

Authors’ original submitted files for images

Literatur
1.
Zurück zum Zitat Frenkel S, Alberti M: Tympanic thermal injuries of the middle ear. J Otolaryng. 1977, 6 (1): 17-22. Frenkel S, Alberti M: Tympanic thermal injuries of the middle ear. J Otolaryng. 1977, 6 (1): 17-22.
2.
Zurück zum Zitat Panosian M, Dutcher J: Transtympanic facial nerve injury in welders. Occup Med. 1994, 44: 99-101. 10.1093/occmed/44.2.99.CrossRef Panosian M, Dutcher J: Transtympanic facial nerve injury in welders. Occup Med. 1994, 44: 99-101. 10.1093/occmed/44.2.99.CrossRef
3.
Zurück zum Zitat Simons J, Eibling D: Tympanic Membrane Perforation and Retained Metal Slag after a Welding Injury. Otolaryngol Head Neck Surg. 2005, 133: 635-636. 10.1016/j.otohns.2005.05.007.CrossRefPubMed Simons J, Eibling D: Tympanic Membrane Perforation and Retained Metal Slag after a Welding Injury. Otolaryngol Head Neck Surg. 2005, 133: 635-636. 10.1016/j.otohns.2005.05.007.CrossRefPubMed
4.
Zurück zum Zitat Syms C, Nelson R: Impression-material foreign bodies of the middle ear and external auditory canal. Otolaryngology Head and Neck Surgery. 1998, 119: 406-407. 10.1016/S0194-5998(98)70090-7.CrossRefPubMed Syms C, Nelson R: Impression-material foreign bodies of the middle ear and external auditory canal. Otolaryngology Head and Neck Surgery. 1998, 119: 406-407. 10.1016/S0194-5998(98)70090-7.CrossRefPubMed
5.
Zurück zum Zitat Schimanski G: Silicone foreign body in the middle ear caused by auditory canal impression in hearing aid fitting. HNO. 1992, 40: 67-68.PubMed Schimanski G: Silicone foreign body in the middle ear caused by auditory canal impression in hearing aid fitting. HNO. 1992, 40: 67-68.PubMed
6.
Zurück zum Zitat Kohan D, Sorin A, Marra S, Gottlieb M, Hoffman R: Surgical managment of complications after hearing aid fitting. Laryngoscope. 2004, 114: 317-322. 10.1097/00005537-200402000-00026.CrossRefPubMed Kohan D, Sorin A, Marra S, Gottlieb M, Hoffman R: Surgical managment of complications after hearing aid fitting. Laryngoscope. 2004, 114: 317-322. 10.1097/00005537-200402000-00026.CrossRefPubMed
7.
Zurück zum Zitat Stage J, Vinding T: Metal spark perforation of the tympanic membrane with deafness and facial paralysis. J Laryng Otol. 1986, 100 (6): 699-700.CrossRef Stage J, Vinding T: Metal spark perforation of the tympanic membrane with deafness and facial paralysis. J Laryng Otol. 1986, 100 (6): 699-700.CrossRef
8.
Zurück zum Zitat Mertens J, Bubmann M, Reker U: Schweissperleverletzungen des Ohres:Beobachtungen am eigenen Krankengut.(German). Laryngo-Rhino-Otologie. 1991, 70 (8): 405-408.CrossRefPubMed Mertens J, Bubmann M, Reker U: Schweissperleverletzungen des Ohres:Beobachtungen am eigenen Krankengut.(German). Laryngo-Rhino-Otologie. 1991, 70 (8): 405-408.CrossRefPubMed
Metadaten
Titel
Metallic foreign body in middle ear: an unusual cause of hearing loss
verfasst von
Anna Eleftheriadou
Thomas Chalastras
Dionysios Kyrmizakis
Sotirios Sfetsos
Konstantinos Dagalakis
Dimitrios Kandiloros
Publikationsdatum
01.12.2007
Verlag
BioMed Central
Erschienen in
Head & Face Medicine / Ausgabe 1/2007
Elektronische ISSN: 1746-160X
DOI
https://doi.org/10.1186/1746-160X-3-23

Weitere Artikel der Ausgabe 1/2007

Head & Face Medicine 1/2007 Zur Ausgabe

Betalaktam-Allergie: praxisnahes Vorgehen beim Delabeling

16.05.2024 Pädiatrische Allergologie Nachrichten

Die große Mehrheit der vermeintlichen Penicillinallergien sind keine. Da das „Etikett“ Betalaktam-Allergie oft schon in der Kindheit erworben wird, kann ein frühzeitiges Delabeling lebenslange Vorteile bringen. Ein Team von Pädiaterinnen und Pädiatern aus Kanada stellt vor, wie sie dabei vorgehen.

Eingreifen von Umstehenden rettet vor Erstickungstod

15.05.2024 Fremdkörperaspiration Nachrichten

Wer sich an einem Essensrest verschluckt und um Luft ringt, benötigt vor allem rasche Hilfe. Dass Umstehende nur in jedem zweiten Erstickungsnotfall bereit waren, diese zu leisten, ist das ernüchternde Ergebnis einer Beobachtungsstudie aus Japan. Doch es gibt auch eine gute Nachricht.

Real-World-Daten sprechen eher für Dupilumab als für Op.

14.05.2024 Rhinosinusitis Nachrichten

Zur Behandlung schwerer Formen der chronischen Rhinosinusitis mit Nasenpolypen (CRSwNP) stehen seit Kurzem verschiedene Behandlungsmethoden zur Verfügung, darunter Biologika, wie Dupilumab, und die endoskopische Sinuschirurgie (ESS). Beim Vergleich der beiden Therapieoptionen war Dupilumab leicht im Vorteil.

Schwindelursache: Massagepistole lässt Otholiten tanzen

14.05.2024 Benigner Lagerungsschwindel Nachrichten

Wenn jüngere Menschen über ständig rezidivierenden Lagerungsschwindel klagen, könnte eine Massagepistole der Auslöser sein. In JAMA Otolaryngology warnt ein Team vor der Anwendung hochpotenter Geräte im Bereich des Nackens.

Update HNO

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.