Skip to main content
Erschienen in: European Radiology 6/2019

12.11.2018 | Cardiac

Minimizing individual variations in arterial enhancement on coronary CT angiographs using “contrast enhancement optimizer”: a prospective randomized single-center study

verfasst von: Yoriaki Matsumoto, Toru Higaki, Takanori Masuda, Tomoyasu Sato, Yuko Nakamura, Fuminari Tatsugami, Kazuo Awai

Erschienen in: European Radiology | Ausgabe 6/2019

Einloggen, um Zugang zu erhalten

Abstract

Objectives

To investigate the clinical utility of our newly developed contrast enhancement optimizer (CEO) software for coronary CT angiography (CCTA).

Methods

We randomly assigned 295 patients (168 males, 127 females, median age 71 years) undergoing CCTA to one of two contrast media injection protocols. Group A (n = 150) was injected with a CEO-selected iodine dose based on patient factors. In group B (n = 145), we used our standard protocol (245 mg I/kg). We recorded the CT number in the ascending aorta and determined whether the CT number was equivalent in groups A and B. For the equivalence test, we adopted 75 Hounsfield units (HU) as the equivalence margin. The standard deviation in the CT number and the rate of patients with an acceptable CT number were compared using the F test and the chi-square test, respectively.

Results

The iodine dose in group A was significantly smaller than that in group B (235.7 vs. 253.6 mg I/kg, p < 0.001). The CT number of the ascending aorta was 428.6 ± 55.5 HU in group A and 436.1 ± 68.7 HU in group B; the 95% confidence interval for the difference between the groups was -4.3 HU to 16.9 HU and within the range of the predetermined equivalence margins. In group A, the variance was significantly smaller than that in group B (p = 0.009). The number of patients with an acceptable CT number was significantly higher in group A than in group B (84.7% vs. 71.7%, p = 0.007).

Conclusions

The use of our CEO for CCTA studies yielded optimal aortic contrast enhancement in significantly more patients than the standard protocol based on the body weight.

Key Points

With our contrast enhancement optimizer (CEO) software, optimal and stable aortic enhancement can be obtained on coronary CT angiography scans irrespective of patient factors.
• Management of contrast media becomes more appropriate by the CEO software.
• The CEO software can control contrast enhancement at different tube voltage levels.
Literatur
1.
Zurück zum Zitat Mowatt G, Cook JA, Hillis GS et al (2008) 64-slice computed tomography angiography in the diagnosis and assessment of coronary artery disease: systematic review and meta-analysis. Heart 94:1386–1393CrossRefPubMed Mowatt G, Cook JA, Hillis GS et al (2008) 64-slice computed tomography angiography in the diagnosis and assessment of coronary artery disease: systematic review and meta-analysis. Heart 94:1386–1393CrossRefPubMed
2.
Zurück zum Zitat Sun Z, Ng KH (2012) Diagnostic value of coronary CT angiography with prospective ECG-gating in the diagnosis of coronary artery disease: a systematic review and meta-analysis. Int J Cardiovasc Imaging 28:2109–2119CrossRefPubMed Sun Z, Ng KH (2012) Diagnostic value of coronary CT angiography with prospective ECG-gating in the diagnosis of coronary artery disease: a systematic review and meta-analysis. Int J Cardiovasc Imaging 28:2109–2119CrossRefPubMed
3.
Zurück zum Zitat Cademartiri F, Mollet NR, Lemos PA et al (2006) Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography. AJR Am J Roentgenol 187:W430–W433CrossRefPubMed Cademartiri F, Mollet NR, Lemos PA et al (2006) Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography. AJR Am J Roentgenol 187:W430–W433CrossRefPubMed
4.
Zurück zum Zitat Cademartiri F, Maffei E, Palumbo AA et al (2008) Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography. Eur Radiol 18:576–583CrossRefPubMed Cademartiri F, Maffei E, Palumbo AA et al (2008) Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography. Eur Radiol 18:576–583CrossRefPubMed
5.
Zurück zum Zitat Fei X, Du X, Yang Q et al (2008) 64-MDCT coronary angiography: phantom study of effects of vascular attenuation on detection of coronary stenosis. AJR Am J Roentgenol 191:43–49CrossRefPubMed Fei X, Du X, Yang Q et al (2008) 64-MDCT coronary angiography: phantom study of effects of vascular attenuation on detection of coronary stenosis. AJR Am J Roentgenol 191:43–49CrossRefPubMed
6.
Zurück zum Zitat Bae KT (2010) Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 256:32–61CrossRef Bae KT (2010) Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 256:32–61CrossRef
7.
Zurück zum Zitat Fleischmann D (2003) Use of high-concentration contrast media in multiple-detector-row CT: principles and rationale. Eur Radiol 13(Suppl 5):M14–M20CrossRefPubMed Fleischmann D (2003) Use of high-concentration contrast media in multiple-detector-row CT: principles and rationale. Eur Radiol 13(Suppl 5):M14–M20CrossRefPubMed
8.
Zurück zum Zitat Rist C, Becker CR, Kirchin MA et al (2008) Optimization of cardiac MSCT contrast injection protocols: dependency of the main bolus contrast density on test bolus parameters and patients’ body weight. Acad Radiol 15:49–57CrossRefPubMed Rist C, Becker CR, Kirchin MA et al (2008) Optimization of cardiac MSCT contrast injection protocols: dependency of the main bolus contrast density on test bolus parameters and patients’ body weight. Acad Radiol 15:49–57CrossRefPubMed
9.
Zurück zum Zitat Seifarth H, Puesken M, Kalafut JF et al (2009) Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiography. Eur Radiol 19:2373–2382CrossRefPubMed Seifarth H, Puesken M, Kalafut JF et al (2009) Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiography. Eur Radiol 19:2373–2382CrossRefPubMed
10.
Zurück zum Zitat Nakaura T, Awai K, Yauaga Y et al (2008) Contrast injection protocols for coronary computed tomography angiography using a 64-detector scanner: comparison between patient weight-adjusted- and fixed iodine-dose protocols. Invest Radiol 43:512–519CrossRefPubMed Nakaura T, Awai K, Yauaga Y et al (2008) Contrast injection protocols for coronary computed tomography angiography using a 64-detector scanner: comparison between patient weight-adjusted- and fixed iodine-dose protocols. Invest Radiol 43:512–519CrossRefPubMed
11.
Zurück zum Zitat Bae KT, Tran HQ, Heiken JP (2004) Uniform vascular contrast enhancement and reduced contrast medium volume achieved by using exponentially decelerated contrast material injection method. Radiology 231:732–736CrossRefPubMed Bae KT, Tran HQ, Heiken JP (2004) Uniform vascular contrast enhancement and reduced contrast medium volume achieved by using exponentially decelerated contrast material injection method. Radiology 231:732–736CrossRefPubMed
12.
Zurück zum Zitat Fleischmann D, Rubin GD, Bankier AA, Hittmair K (2000) Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography. Radiology 214:363–371CrossRefPubMed Fleischmann D, Rubin GD, Bankier AA, Hittmair K (2000) Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography. Radiology 214:363–371CrossRefPubMed
13.
Zurück zum Zitat Higaki T, Nakaura T, Kidoh M et al (2018) Effect of contrast material injection duration on arterial enhancement at CT in patients with various cardiac indices: analysis using computer simulation. PLoS One 13:e0191347CrossRefPubMedPubMedCentral Higaki T, Nakaura T, Kidoh M et al (2018) Effect of contrast material injection duration on arterial enhancement at CT in patients with various cardiac indices: analysis using computer simulation. PLoS One 13:e0191347CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate—pharmacokinetic analysis and experimental porcine model. Radiology 206:455–464CrossRefPubMed Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate—pharmacokinetic analysis and experimental porcine model. Radiology 206:455–464CrossRefPubMed
15.
Zurück zum Zitat Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model. Radiology 207:647–655CrossRefPubMed Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model. Radiology 207:647–655CrossRefPubMed
16.
Zurück zum Zitat Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model. Radiology 207:657–662CrossRefPubMed Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model. Radiology 207:657–662CrossRefPubMed
17.
Zurück zum Zitat Blohm ME, Obrecht D, Hartwich J et al (2014) Impedance cardiography (electrical velocimetry) and transthoracic echocardiography for non-invasive cardiac output monitoring in pediatric intensive care patients: a prospective single-center observational study. Crit Care 18:603CrossRefPubMedPubMedCentral Blohm ME, Obrecht D, Hartwich J et al (2014) Impedance cardiography (electrical velocimetry) and transthoracic echocardiography for non-invasive cardiac output monitoring in pediatric intensive care patients: a prospective single-center observational study. Crit Care 18:603CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Hsu KH, Wu TW, Wang YC, Lim WH, Lee CC, Lien R (2016) Hemodynamic reference for neonates of different age and weight: a pilot study with electrical cardiometry. J Perinatol 36:481–485CrossRefPubMed Hsu KH, Wu TW, Wang YC, Lim WH, Lee CC, Lien R (2016) Hemodynamic reference for neonates of different age and weight: a pilot study with electrical cardiometry. J Perinatol 36:481–485CrossRefPubMed
19.
Zurück zum Zitat Nakaura T, Awai K, Yanaga Y et al (2011) Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography. Jpn J Radiol 29:457–465CrossRefPubMed Nakaura T, Awai K, Yanaga Y et al (2011) Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography. Jpn J Radiol 29:457–465CrossRefPubMed
20.
Zurück zum Zitat Yamamuro M, Tadamura E, Kanao S et al (2007) Coronary angiography by 64-detector row computed tomography using low dose of contrast material with saline chaser: influence of total injection volume on vessel attenuation. J Comput Assist Tomogr 31:272–280CrossRefPubMed Yamamuro M, Tadamura E, Kanao S et al (2007) Coronary angiography by 64-detector row computed tomography using low dose of contrast material with saline chaser: influence of total injection volume on vessel attenuation. J Comput Assist Tomogr 31:272–280CrossRefPubMed
21.
Zurück zum Zitat Cademartiri F, Nieman K, van der Lugt A et al (2004) Intravenous contrast material administration at 16-detector row helical CT coronary angiography: test bolus versus bolus-tracking technique. Radiology 233:817–823CrossRefPubMed Cademartiri F, Nieman K, van der Lugt A et al (2004) Intravenous contrast material administration at 16-detector row helical CT coronary angiography: test bolus versus bolus-tracking technique. Radiology 233:817–823CrossRefPubMed
23.
Zurück zum Zitat Cademartiri F, Mollet N, van der Lugt A et al (2004) Non-invasive 16-row multislice CT coronary angiography: usefulness of saline chaser. Eur Radiol 14:178–183CrossRefPubMed Cademartiri F, Mollet N, van der Lugt A et al (2004) Non-invasive 16-row multislice CT coronary angiography: usefulness of saline chaser. Eur Radiol 14:178–183CrossRefPubMed
24.
Zurück zum Zitat Abbara S, Blanke P, Maroules CD et al (2016) SCCT guidelines for the performance and acquisition of coronary computed tomographic angiography: a report of the Society of Cardiovascular Computed Tomography Guidelines Committee: endorsed by the North American Society for Cardiovascular Imaging (NASCI). J Cardiovasc Comput Tomogr 10:435–449CrossRef Abbara S, Blanke P, Maroules CD et al (2016) SCCT guidelines for the performance and acquisition of coronary computed tomographic angiography: a report of the Society of Cardiovascular Computed Tomography Guidelines Committee: endorsed by the North American Society for Cardiovascular Imaging (NASCI). J Cardiovasc Comput Tomogr 10:435–449CrossRef
25.
Zurück zum Zitat Piaggio G, Elbourne DR, Pocock SJ, Evans SJ, Altman DG; CONSORT Group (2012) Reporting of noninferiority and equivalence randomized trials: extension of the CONSORT 2010 statement. JAMA 308:2594–2604 Piaggio G, Elbourne DR, Pocock SJ, Evans SJ, Altman DG; CONSORT Group (2012) Reporting of noninferiority and equivalence randomized trials: extension of the CONSORT 2010 statement. JAMA 308:2594–2604
26.
Zurück zum Zitat Gönen M, Panageas K, Larson S (2001) Statistical issues in analysis of diagnostic imaging experiments with multiple observations per patient. Radiology 221:763–767 Gönen M, Panageas K, Larson S (2001) Statistical issues in analysis of diagnostic imaging experiments with multiple observations per patient. Radiology 221:763–767
27.
Zurück zum Zitat Bae KT, Heiken JP (2005) Scan and contrast administration principles of MDCT. Eur Radiol 15(Suppl 5):E46–E59CrossRefPubMed Bae KT, Heiken JP (2005) Scan and contrast administration principles of MDCT. Eur Radiol 15(Suppl 5):E46–E59CrossRefPubMed
28.
Zurück zum Zitat Bae KT (2010) Optimization of contrast enhancement in thoracic MDCT. Radiol Clin North Am 48:9–29CrossRefPubMed Bae KT (2010) Optimization of contrast enhancement in thoracic MDCT. Radiol Clin North Am 48:9–29CrossRefPubMed
29.
Zurück zum Zitat Fleischmann D (2005) How to design injection protocols for multiple detector-row CT angiography (MDCTA). Eur Radiol 15(Suppl 5):E60–E65CrossRefPubMed Fleischmann D (2005) How to design injection protocols for multiple detector-row CT angiography (MDCTA). Eur Radiol 15(Suppl 5):E60–E65CrossRefPubMed
30.
Zurück zum Zitat Fleischmann D (2010) CT angiography: injection and acquisition technique. Radiol Clin North Am 48:237–247 viiCrossRefPubMed Fleischmann D (2010) CT angiography: injection and acquisition technique. Radiol Clin North Am 48:237–247 viiCrossRefPubMed
31.
Zurück zum Zitat Awai K, Hiraishi K, Hori S (2004) Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight. Radiology 230:142–150CrossRefPubMed Awai K, Hiraishi K, Hori S (2004) Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight. Radiology 230:142–150CrossRefPubMed
32.
Zurück zum Zitat Yanaga Y, Awai K, Nakayama Y et al (2007) Pancreas: patient body weight tailored contrast material injection protocol versus fixed dose protocol at dynamic CT. Radiology 245:475–482CrossRefPubMed Yanaga Y, Awai K, Nakayama Y et al (2007) Pancreas: patient body weight tailored contrast material injection protocol versus fixed dose protocol at dynamic CT. Radiology 245:475–482CrossRefPubMed
33.
Zurück zum Zitat Masuda T, Nakaura T, Funama Y et al (2017) Aortic and hepatic contrast enhancement during hepatic-arterial and portal venous phase computed tomography scanning: multivariate linear regression analysis using age, sex, total body weight, height, and cardiac output. J Comput Assist Tomogr 41:309–314CrossRefPubMed Masuda T, Nakaura T, Funama Y et al (2017) Aortic and hepatic contrast enhancement during hepatic-arterial and portal venous phase computed tomography scanning: multivariate linear regression analysis using age, sex, total body weight, height, and cardiac output. J Comput Assist Tomogr 41:309–314CrossRefPubMed
34.
Zurück zum Zitat Yanaga Y, Awai K, Nakayama Y et al (2007) Optimal dose and injection duration (injection rate) of contrast material for depiction of hypervascular hepatocellular carcinomas by multidetector CT. Radiat Med 25:278–288CrossRefPubMed Yanaga Y, Awai K, Nakayama Y et al (2007) Optimal dose and injection duration (injection rate) of contrast material for depiction of hypervascular hepatocellular carcinomas by multidetector CT. Radiat Med 25:278–288CrossRefPubMed
Metadaten
Titel
Minimizing individual variations in arterial enhancement on coronary CT angiographs using “contrast enhancement optimizer”: a prospective randomized single-center study
verfasst von
Yoriaki Matsumoto
Toru Higaki
Takanori Masuda
Tomoyasu Sato
Yuko Nakamura
Fuminari Tatsugami
Kazuo Awai
Publikationsdatum
12.11.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 6/2019
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-018-5823-2

Weitere Artikel der Ausgabe 6/2019

European Radiology 6/2019 Zur Ausgabe

Update Radiologie