Skip to main content
Erschienen in: Japanese Journal of Radiology 9/2012

01.11.2012 | Original article

MR imaging of meniscal tears: comparison of intermediate-weighted FRFSE imaging with intermediate-weighted FSE imaging

verfasst von: Osamu Tokuda, Yuko Harada, Takaaki Ueda, Etsushi Iida, Gen Shiraishi, Tetsuhisa Motomura, Kouji Fukuda, Naofumi Matsunaga

Erschienen in: Japanese Journal of Radiology | Ausgabe 9/2012

Einloggen, um Zugang zu erhalten

Abstract

Purpose

We compared intermediate-weighted fast spin-echo (IW-FSE) images with intermediate-weighted fast-recovery FSE (IW-FRFSE) images in the diagnosis of meniscal tears.

Materials and methods

First, 64 patients were recruited, and the arthroscopic findings (n = 40) and image analysis (n = 19) identified 59 torn menisci with 36 patients. Both the diagnostic performance and image quality in assessing meniscal tears was evaluated for IW-FSE and IW-FRFSE images using a four-point scale. Signal-to-noise ratio (SNR) calculation was performed for both sets of images.

Results

IW-FRFSE image specificity (100 %) for diagnosing the posterior horn of the medial meniscus (MM) tear with reader 1 was significantly higher than that of IW-FSE images (90 %). Mean ratings of the contrast between the lesion and normal signal intensity within the meniscus were significantly higher for the IW-FRFSE image ratings than the IW-FSE images in most meniscal tears. Mean SNRs were significantly higher for IW-FSE images than for IW-FRFSE images (P < 0.05).

Conclusions

IW-FRFSE imaging can be used as an alternative to the IW-FSE imaging to evaluate meniscal tears.
Literatur
1.
Zurück zum Zitat Subhas N, Kao A, Friere M, Polster JM, Obuchowski NA, Winalski CS. MRI of the knee ligaments and menisci: comparison of isotropic resolution 3D and conventional 2D fast spin-echo sequences at 3T. AJR Am J Roentgenol. 2011;197:442–50.PubMedCrossRef Subhas N, Kao A, Friere M, Polster JM, Obuchowski NA, Winalski CS. MRI of the knee ligaments and menisci: comparison of isotropic resolution 3D and conventional 2D fast spin-echo sequences at 3T. AJR Am J Roentgenol. 2011;197:442–50.PubMedCrossRef
2.
Zurück zum Zitat Gold GE, Busse RF, Beehler C, Han E, Brau AC, Beatty PJ, et al. Isotropic MRI of the knee with 3D fast spin-echo extended echo-train acquisition (XETA): initial experience. AJR Am J Roentgenol. 2007;188:1287–93.PubMedCrossRef Gold GE, Busse RF, Beehler C, Han E, Brau AC, Beatty PJ, et al. Isotropic MRI of the knee with 3D fast spin-echo extended echo-train acquisition (XETA): initial experience. AJR Am J Roentgenol. 2007;188:1287–93.PubMedCrossRef
3.
Zurück zum Zitat Notohampiprodjo M, Horng A, Pietschmann MF, Muller PE, Horger W, Park J, et al. MRI of the knee at 3T. Investig Radiol. 2009;44:585–97.CrossRef Notohampiprodjo M, Horng A, Pietschmann MF, Muller PE, Horger W, Park J, et al. MRI of the knee at 3T. Investig Radiol. 2009;44:585–97.CrossRef
4.
Zurück zum Zitat Park J, Mugler JP III, Horger W, Kiefer B. Optimized T1-weighted contrast for single-slab 3D turbo spin-echo imaging with long echo trains: application to whole-brain imaging. Magn Reson Med. 2007;58:982–92.PubMedCrossRef Park J, Mugler JP III, Horger W, Kiefer B. Optimized T1-weighted contrast for single-slab 3D turbo spin-echo imaging with long echo trains: application to whole-brain imaging. Magn Reson Med. 2007;58:982–92.PubMedCrossRef
5.
Zurück zum Zitat Jung JY, Yoon YC, Kwon JW, Kwon JW, Ahn JH, Choe BK. Diagnosis of internal derangement of the knee at 3.0-T MR imaging: 3D isotropic intermediate-weighted versus 2D sequences. Radiology. 2009;253:780–7.PubMedCrossRef Jung JY, Yoon YC, Kwon JW, Kwon JW, Ahn JH, Choe BK. Diagnosis of internal derangement of the knee at 3.0-T MR imaging: 3D isotropic intermediate-weighted versus 2D sequences. Radiology. 2009;253:780–7.PubMedCrossRef
6.
Zurück zum Zitat Woertler K, Rummeny EJ, Settles M. A fast high-resolution multislice T1-weighted turbo spin-echo (TSE) sequence with a DRIVen equilibrium (DRIVE) pulse for native arthrographic contrast. AJR Am J Roentgenol. 2005;185:1468–70.PubMedCrossRef Woertler K, Rummeny EJ, Settles M. A fast high-resolution multislice T1-weighted turbo spin-echo (TSE) sequence with a DRIVen equilibrium (DRIVE) pulse for native arthrographic contrast. AJR Am J Roentgenol. 2005;185:1468–70.PubMedCrossRef
7.
Zurück zum Zitat Radlbauer R, Lomoschitz F, Salomonowitz E, Salpmonowitz E, Eberhardt KE, Stadlbauer A. MR imaging of the knee: improvement of signal and contrast efficiency of T1-weighted turbo spin echo sequences by applying a driven equilibrium (DRIVE) pulse. Eur J Radiol. 2010;75:e82–7.PubMedCrossRef Radlbauer R, Lomoschitz F, Salomonowitz E, Salpmonowitz E, Eberhardt KE, Stadlbauer A. MR imaging of the knee: improvement of signal and contrast efficiency of T1-weighted turbo spin echo sequences by applying a driven equilibrium (DRIVE) pulse. Eur J Radiol. 2010;75:e82–7.PubMedCrossRef
8.
Zurück zum Zitat Hargreaves BA, Gold GE, Lang PK, Conolly SM, Pauly JM, Bergman G, et al. MR imaging of articular cartilage using driven equilibrium. Magn Reson Med. 1999;42:695–703.PubMedCrossRef Hargreaves BA, Gold GE, Lang PK, Conolly SM, Pauly JM, Bergman G, et al. MR imaging of articular cartilage using driven equilibrium. Magn Reson Med. 1999;42:695–703.PubMedCrossRef
9.
Zurück zum Zitat Gold GE, Fuller SE, Hargreaves BA, Stevens KJ, Beaulieu CF. Driven equilibrium magnetic resonance imaging of articular cartilage: initial clinical experience. J Magn Reson Imaging. 2005;21:476–81.PubMedCrossRef Gold GE, Fuller SE, Hargreaves BA, Stevens KJ, Beaulieu CF. Driven equilibrium magnetic resonance imaging of articular cartilage: initial clinical experience. J Magn Reson Imaging. 2005;21:476–81.PubMedCrossRef
10.
Zurück zum Zitat Melhem ER, Itoh R, Folkers PJM. Cervical spine: three dimensional fast spin-echo MR imaging—improved recovery of longitudinal magnetization with driven equilibrium pulse. Radiology. 2001;218:283–8.PubMed Melhem ER, Itoh R, Folkers PJM. Cervical spine: three dimensional fast spin-echo MR imaging—improved recovery of longitudinal magnetization with driven equilibrium pulse. Radiology. 2001;218:283–8.PubMed
11.
Zurück zum Zitat De Smet AA, Norris MA, Yandow DR, Quintana FA, Graf BK, Keene JS. MR diagnosis of meniscal tears of the knee: importance of high signal in the meniscus that extends to the surface. AJR Am J Roentgenol. 1993;161:101–7.PubMed De Smet AA, Norris MA, Yandow DR, Quintana FA, Graf BK, Keene JS. MR diagnosis of meniscal tears of the knee: importance of high signal in the meniscus that extends to the surface. AJR Am J Roentgenol. 1993;161:101–7.PubMed
12.
Zurück zum Zitat Crues JV 3rd, Mink J, Levy TL, Lotysch M, Stoller DW. Meniscal tears of the knee: accuracy of MR imaging. Radiology. 1987;164:445–8.PubMed Crues JV 3rd, Mink J, Levy TL, Lotysch M, Stoller DW. Meniscal tears of the knee: accuracy of MR imaging. Radiology. 1987;164:445–8.PubMed
13.
Zurück zum Zitat Stoller D, Tirman P, Bredella M, Branstetter R, Blease S, Beltran S, et al. Diagnostic imaging: orthopedics, vol 5. 1st ed. Amsterdam: Elsevier; 2003. p. 18–41. Stoller D, Tirman P, Bredella M, Branstetter R, Blease S, Beltran S, et al. Diagnostic imaging: orthopedics, vol 5. 1st ed. Amsterdam: Elsevier; 2003. p. 18–41.
Metadaten
Titel
MR imaging of meniscal tears: comparison of intermediate-weighted FRFSE imaging with intermediate-weighted FSE imaging
verfasst von
Osamu Tokuda
Yuko Harada
Takaaki Ueda
Etsushi Iida
Gen Shiraishi
Tetsuhisa Motomura
Kouji Fukuda
Naofumi Matsunaga
Publikationsdatum
01.11.2012
Verlag
Springer Japan
Erschienen in
Japanese Journal of Radiology / Ausgabe 9/2012
Print ISSN: 1867-1071
Elektronische ISSN: 1867-108X
DOI
https://doi.org/10.1007/s11604-012-0108-1

Weitere Artikel der Ausgabe 9/2012

Japanese Journal of Radiology 9/2012 Zur Ausgabe

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.