Skip to main content
Erschienen in: Abdominal Radiology 3/2005

01.06.2005

MR peritoneography in complications of continuous ambulatory peritoneal dialysis

verfasst von: K. Yavuz, A. Erden, K. Ateş, I. Erden

Erschienen in: Abdominal Radiology | Ausgabe 3/2005

Einloggen, um Zugang zu erhalten

Abstract

Background

We evaluated the usefulness of magnetic resonance (MR) peritoneography for the examination of complications from continuous ambulatory peritoneal dialysis (CAPD).

Methods

MR peritoneography was performed in 20 patients who had suspected CAPD-related complications. Patients who had active peritonitis were not included in the study. Before MR imaging, a mixture of 2000 mL of peritoneal dialysis solution and 20 mL of gadopentetate dimeglumine was instilled into the peritoneal cavity. MR imaging was performed on a 1.0-Tesla system using a body coil. Axial, coronal, and sagittal fat-saturated fast spoiled gradient echo (repetition/echo times, 100/6.3 ms; flip angle, 90 degrees), axial fat-saturated T2-weighted fast spin echo (repetition/echo times, 6000/107 ms), and coronal fat-saturated T2-weighted fast spin echo (repetition/echo times, 3000/96.2 ms) images of the abdomen and the pelvis were obtained. After drain-age, triplanar fat-saturated fast spoiled gradient echo images were repeated with the same parameters.

Results

Homogeneous distribution of the dialysate in the peritoneal cavity was detected in 18 patients (90%). In 12 patients (60%), fluid leaks were discovered peripheral to the exit site, tunnel, and site of peritoneal entrance of the catheter. Fluid leaks through the abdominal wall in five patients (25%), retroperitoneum in one patient (5%), and a previous operation site in one patient (5%) were demonstrated. No abnormal finding was detected in three patients (15%) who had clinically suspected complications, whereas a dialysate leak was found in two patients (10%) who had no significant finding at physical examination.

Conclusions

MR peritoneography provides detailed information about the anatomic distribution of dialysate leaks in patients treated with CAPD and poses no risks associated with ionizing radiation and nephrotoxic contrast medium.
Literatur
1.
Zurück zum Zitat Yost, L 1997Baxter worldwide overviewDeerfieldIL Yost, L 1997Baxter worldwide overviewDeerfieldIL
2.
Zurück zum Zitat Lameire, N, Biesen, W, Dombros, N, et al. 1997The referral pattern of patients with ESRD is a determinant choice of dialysis modalityPerit Dial Int17S161S166PubMed Lameire, N, Biesen, W, Dombros, N,  et al. 1997The referral pattern of patients with ESRD is a determinant choice of dialysis modalityPerit Dial Int17S161S166PubMed
3.
Zurück zum Zitat Nissenson, AR, Prichard, SS, Cheng, IKP, et al. 1993Non-medical factors that impact on ESRD modality selectionKidney Int43120 Nissenson, AR, Prichard, SS, Cheng, IKP,  et al. 1993Non-medical factors that impact on ESRD modality selectionKidney Int43120
4.
Zurück zum Zitat Ganter, G 1923Uber die beseitigun giftiger stoffe aus dem blute durch dialyseMunch Med Wochenschr701478 Ganter, G 1923Uber die beseitigun giftiger stoffe aus dem blute durch dialyseMunch Med Wochenschr701478
5.
Zurück zum Zitat Popovich, RP, Moncrief, JW, Decherd, JF, et al. 1976The definition of a novel portable-wearable equilibrium peritoneal techniqueASAIO J564 Popovich, RP, Moncrief, JW, Decherd, JF,  et al. 1976The definition of a novel portable-wearable equilibrium peritoneal techniqueASAIO J564
6.
Zurück zum Zitat Holley, HL, Piraino, BM 1990Complications of peritoneal dialysis: diagnosis and managementSemin Dial3245 Holley, HL, Piraino, BM 1990Complications of peritoneal dialysis: diagnosis and managementSemin Dial3245
7.
Zurück zum Zitat Burkart, JM 2000Peritoneal dialysisBrenner, BMRector, FC eds. The kidney6WB SaundersPhiladelphia24542502 Burkart, JM 2000Peritoneal dialysisBrenner, BMRector, FC eds. The kidney6WB SaundersPhiladelphia24542502
8.
Zurück zum Zitat Ducassou, D, Vuillemin, L, Wone, C, et al. 1984Intraperitoneal injection of technetium−99m sulfur colloid in visualization of a peritoneo-vaginalis connectionsJ Nucl Med256869PubMed Ducassou, D, Vuillemin, L, Wone, C,  et al. 1984Intraperitoneal injection of technetium−99m sulfur colloid in visualization of a peritoneo-vaginalis connectionsJ Nucl Med256869PubMed
9.
Zurück zum Zitat Hollett, MD, Marn, CS, Ellis, JH, et al. 1992Complications of continuous ambulatory peritoneal dialysis: evaluation with CT peritoneographyAJR159983989PubMed Hollett, MD, Marn, CS, Ellis, JH,  et al. 1992Complications of continuous ambulatory peritoneal dialysis: evaluation with CT peritoneographyAJR159983989PubMed
10.
Zurück zum Zitat Twardowski, ZJ, Tully, RJ, Nichols, WK, Sunderrajan, S 1984Computerized tomography in the diagnosis of subcutaneous leak sites during continuous ambulatory peritoneal dialysis (CAPD)Perit Dial Int4163166 Twardowski, ZJ, Tully, RJ, Nichols, WK, Sunderrajan, S 1984Computerized tomography in the diagnosis of subcutaneous leak sites during continuous ambulatory peritoneal dialysis (CAPD)Perit Dial Int4163166
11.
Zurück zum Zitat Singal, K, Segel, DP, Bruns, FJ, et al. 1986Genital edema in patients on continuous ambulatory peritoneal dialysisAm J Nephrol6471475PubMed Singal, K, Segel, DP, Bruns, FJ,  et al. 1986Genital edema in patients on continuous ambulatory peritoneal dialysisAm J Nephrol6471475PubMed
12.
Zurück zum Zitat Prokesch, RW, Schima, W, Schober, E, et al. 2000Complications of continuous ambulatory peritoneal dialysis: findings on MR peritoneographyAJR174987991PubMed Prokesch, RW, Schima, W, Schober, E,  et al. 2000Complications of continuous ambulatory peritoneal dialysis: findings on MR peritoneographyAJR174987991PubMed
13.
Zurück zum Zitat Arbeiter, KM, Aufricht, C, Mueller, T, et al. 2001MRI in the diagnosis of a peritoneal leak in continous ambulatory peritoneal dialysisPediatr Radiol31745747CrossRefPubMed Arbeiter, KM, Aufricht, C, Mueller, T,  et al. 2001MRI in the diagnosis of a peritoneal leak in continous ambulatory peritoneal dialysisPediatr Radiol31745747CrossRefPubMed
14.
Zurück zum Zitat Gokal, R, Jakubowski, C, King, J, et al. 1987Outcome in patients on continuous ambulatory peritoneal dialysis and hemodialysis: 4-year analysis of a prospective multicentre studyLancet11105CrossRefPubMed Gokal, R, Jakubowski, C, King, J,  et al. 1987Outcome in patients on continuous ambulatory peritoneal dialysis and hemodialysis: 4-year analysis of a prospective multicentre studyLancet11105CrossRefPubMed
15.
Zurück zum Zitat Kopecky, RT, Funk, MM, Kreitzer, PR 1985Localized genital edema in patients undergoing continuous ambulatory peritoneal dialysisJ Urol134880PubMed Kopecky, RT, Funk, MM, Kreitzer, PR 1985Localized genital edema in patients undergoing continuous ambulatory peritoneal dialysisJ Urol134880PubMed
16.
Zurück zum Zitat Capelouto, CC, DeWolf, WC 1993Genital swelling secondary to leakage from continuous ambulatory peritoneal dialysis: computerized tomography diagnosisJ Urol150196198PubMed Capelouto, CC, DeWolf, WC 1993Genital swelling secondary to leakage from continuous ambulatory peritoneal dialysis: computerized tomography diagnosisJ Urol150196198PubMed
17.
Zurück zum Zitat Winchester, JF, Kriger, FL 1994Fluid leaks: prevention and treatmentPerit Dial Int144348 Winchester, JF, Kriger, FL 1994Fluid leaks: prevention and treatmentPerit Dial Int144348
18.
Zurück zum Zitat Rubin, J, Adair, CM, Raju, S, Bower, JD 1982The Tenckhoff catheter for peritoneal dialysis-an appraisalNephron32370374PubMed Rubin, J, Adair, CM, Raju, S, Bower, JD 1982The Tenckhoff catheter for peritoneal dialysis-an appraisalNephron32370374PubMed
19.
Zurück zum Zitat Davis, AS, Reed, WP 1983A leak free technique for open insertion of peritoneal dialysis cathetersSurg Gynecol Obstet157579580PubMed Davis, AS, Reed, WP 1983A leak free technique for open insertion of peritoneal dialysis cathetersSurg Gynecol Obstet157579580PubMed
20.
Zurück zum Zitat Engeset, J, Youngson, GG 1984Ambulatory peritoneal dialysis and hernial complicationsSurg Clin North Am64385392PubMed Engeset, J, Youngson, GG 1984Ambulatory peritoneal dialysis and hernial complicationsSurg Clin North Am64385392PubMed
21.
Zurück zum Zitat Prince, MR, Arnoldus, C, Frisoli, JK 1996Nephrotoxicity of high-dose gadolinium compared with iodinated contrastJ Magn Reson Imaging6162166PubMed Prince, MR, Arnoldus, C, Frisoli, JK 1996Nephrotoxicity of high-dose gadolinium compared with iodinated contrastJ Magn Reson Imaging6162166PubMed
22.
Zurück zum Zitat Dörsam, J, Knopp, MV, Schad, L, et al. 1995Elimination of gadolinium-DTPA by peritoneal dialysisNephrol Dial Transpl1012281230 Dörsam, J, Knopp, MV, Schad, L,  et al. 1995Elimination of gadolinium-DTPA by peritoneal dialysisNephrol Dial Transpl1012281230
Metadaten
Titel
MR peritoneography in complications of continuous ambulatory peritoneal dialysis
verfasst von
K. Yavuz
A. Erden
K. Ateş
I. Erden
Publikationsdatum
01.06.2005
Erschienen in
Abdominal Radiology / Ausgabe 3/2005
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-004-0271-7

Weitere Artikel der Ausgabe 3/2005

Abdominal Radiology 3/2005 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.