Medicine is evolving toward personalized care and this development entails the integration, amalgamation, and synchronized analysis of data from multiple sources. Multimodality fusion imaging refers to the simultaneous visualization of spatially aligned and juxtaposed medical images obtained by two or more image modalities. PET/MRI scanners and MMFI platforms are able to improve the diagnostic workflow in oncologic patients and provide exquisite images that aid physicians in the molecular profiling and characterization of tissues. Advanced navigation platforms involving real-time ultrasound are promising tools for guiding personalized and tailored mini-invasive interventional procedures on technically challenging targets. The main objective of the present essay was to describe the current applications and future perspectives of multimodality fusion imaging for both diagnostic and interventional purposes in the field of abdominal and pelvic malignancies. We also outlined the technical differences between fusion imaging achieved by means of simultaneous bimodal acquisition (i.e., integrated PET/MRI scanners), retrospective co-registration, and multimodality fusion imaging involving ultrafast or real-time imaging modalities.
Literatur
1.
Zurück zum Zitat Beyer T, Freudenberg LS, Townsend DW, Czernin J (2011) The future of hybrid imaging-part 1: hybrid imaging technologies and SPECT/CT. Insights Imaging 2:161–169PubMedCentralCrossRefPubMed Beyer T, Freudenberg LS, Townsend DW, Czernin J (2011) The future of hybrid imaging-part 1: hybrid imaging technologies and SPECT/CT. Insights Imaging 2:161–169PubMedCentralCrossRefPubMed
3.
Zurück zum Zitat Ewertsen C, Săftoiu A, Gruionu LG, Karstrup S, Nielsen MB (2013) Real-time image fusion involving diagnostic ultrasound. AJR Am J Roentgenol 200:249–255CrossRef Ewertsen C, Săftoiu A, Gruionu LG, Karstrup S, Nielsen MB (2013) Real-time image fusion involving diagnostic ultrasound. AJR Am J Roentgenol 200:249–255CrossRef
4.
Zurück zum Zitat Piccardo A, Paparo F, Picazzo R, et al. (2014) Value of fused 18F-Choline-PET/MRI to evaluate prostate cancer relapse in patients showing biochemical recurrence after EBRT: preliminary results. Biomed Res Int 2014:103718PubMedCentralCrossRefPubMed Piccardo A, Paparo F, Picazzo R, et al. (2014) Value of fused 18F-Choline-PET/MRI to evaluate prostate cancer relapse in patients showing biochemical recurrence after EBRT: preliminary results. Biomed Res Int 2014:103718PubMedCentralCrossRefPubMed
5.
Zurück zum Zitat Abi-Jaoudeh N, Kruecker J, Kadoury S, et al. (2012) Multimodality image fusion-guided procedures: technique, accuracy, and applications. Cardiovasc Intervent Radiol 35:986–998PubMedCentralCrossRefPubMed Abi-Jaoudeh N, Kruecker J, Kadoury S, et al. (2012) Multimodality image fusion-guided procedures: technique, accuracy, and applications. Cardiovasc Intervent Radiol 35:986–998PubMedCentralCrossRefPubMed
6.
Zurück zum Zitat Slomka PJ, Baum RP (2009) Multimodality image registration with software: state-of-the-art. Eur J Nucl Med Mol Imaging 36(1):44–55CrossRef Slomka PJ, Baum RP (2009) Multimodality image registration with software: state-of-the-art. Eur J Nucl Med Mol Imaging 36(1):44–55CrossRef
7.
Zurück zum Zitat Appelbaum L, Mahgerefteh SY, Sosna J, Goldberg SN (2013) Image-guided fusion and navigation: applications in tumor ablation. Tech Vasc Interv Radiol 16:287–295CrossRefPubMed Appelbaum L, Mahgerefteh SY, Sosna J, Goldberg SN (2013) Image-guided fusion and navigation: applications in tumor ablation. Tech Vasc Interv Radiol 16:287–295CrossRefPubMed
8.
Zurück zum Zitat Mauri G, Cova L, De Beni S, et al. (2015) Real-time US-CT/MRI image fusion for guidance of thermal ablation of liver tumors undetectable with US: results in 295 cases. Cardiovasc Intervent Radiol 38:143–151CrossRefPubMed Mauri G, Cova L, De Beni S, et al. (2015) Real-time US-CT/MRI image fusion for guidance of thermal ablation of liver tumors undetectable with US: results in 295 cases. Cardiovasc Intervent Radiol 38:143–151CrossRefPubMed
9.
Zurück zum Zitat Paparo F, Piccazzo R, Cevasco L, et al. (2014) Advantages of percutaneous abdominal biopsy under PET-CT/ultrasound fusion imaging guidance: a pictorial essay. Abdom Imaging 39:1102–1113CrossRefPubMed Paparo F, Piccazzo R, Cevasco L, et al. (2014) Advantages of percutaneous abdominal biopsy under PET-CT/ultrasound fusion imaging guidance: a pictorial essay. Abdom Imaging 39:1102–1113CrossRefPubMed
10.
Zurück zum Zitat James PA, Dasarathy BV (2014) Medical image fusion: a survey of the state of the art. Inf Fusion 19:4–19CrossRef James PA, Dasarathy BV (2014) Medical image fusion: a survey of the state of the art. Inf Fusion 19:4–19CrossRef
11.
Zurück zum Zitat Woods RP, Grafton ST, Holmes CJ, Cherry SR, Mazziotta JC (1998) Automated image registration: I. General methods and intrasubject, intramodality validation. J Comput Assist Tomogrv 22:139–152CrossRef Woods RP, Grafton ST, Holmes CJ, Cherry SR, Mazziotta JC (1998) Automated image registration: I. General methods and intrasubject, intramodality validation. J Comput Assist Tomogrv 22:139–152CrossRef
12.
Zurück zum Zitat Giesel FL, Mehndiratta A, Locklin J, et al. (2009) Image fusion using CT, MRI and PET for treatment planning, navigation and follow up in percutaneous RFA. Exp Oncol 31:106–114PubMedCentralPubMed Giesel FL, Mehndiratta A, Locklin J, et al. (2009) Image fusion using CT, MRI and PET for treatment planning, navigation and follow up in percutaneous RFA. Exp Oncol 31:106–114PubMedCentralPubMed
13.
Zurück zum Zitat Zitova Barbara, Flusser Jan (2003) Image registration methods: a survey. Image Vis Comput 21:977–1000CrossRef Zitova Barbara, Flusser Jan (2003) Image registration methods: a survey. Image Vis Comput 21:977–1000CrossRef
14.
Zurück zum Zitat Wood BJ, Kruecker J, Abi-Jaoudeh N, et al. (2010) Navigation systems for ablation. J Vasc Interv Radiol 21(8):257–263CrossRef Wood BJ, Kruecker J, Abi-Jaoudeh N, et al. (2010) Navigation systems for ablation. J Vasc Interv Radiol 21(8):257–263CrossRef
15.
Zurück zum Zitat Maccioni F, Patak MA, Signore A, Laghi A (2012) New frontiers of MRI in Crohn’s disease: motility imaging, diffusion-weighted imaging, perfusion MRI, MR spectroscopy, molecular imaging, and hybrid imaging (PET/MRI). Abdom Imaging 37:974–982CrossRefPubMed Maccioni F, Patak MA, Signore A, Laghi A (2012) New frontiers of MRI in Crohn’s disease: motility imaging, diffusion-weighted imaging, perfusion MRI, MR spectroscopy, molecular imaging, and hybrid imaging (PET/MRI). Abdom Imaging 37:974–982CrossRefPubMed
16.
Zurück zum Zitat Appelbaum L, Solbiati L, Sosna J, et al. (2013) Evaluation of an electromagnetic image-fusion navigation system for biopsy of small lesions: assessment of accuracy in an in vivo swine model. Acad Radiol 20:209–217CrossRefPubMed Appelbaum L, Solbiati L, Sosna J, et al. (2013) Evaluation of an electromagnetic image-fusion navigation system for biopsy of small lesions: assessment of accuracy in an in vivo swine model. Acad Radiol 20:209–217CrossRefPubMed
18.
Zurück zum Zitat Beyer T, Freudenberg LS, Czernin J, Townsend DW (2011) The future of hybrid imaging-part 3: PET/MR, small-animal imaging and beyond. Insights Imaging 2:235–246PubMedCentralCrossRefPubMed Beyer T, Freudenberg LS, Czernin J, Townsend DW (2011) The future of hybrid imaging-part 3: PET/MR, small-animal imaging and beyond. Insights Imaging 2:235–246PubMedCentralCrossRefPubMed
19.
Zurück zum Zitat von Schulthess GK, Kuhn FP, Kaufmann P, Veit-Haibach P (2013) Clinical positron emission tomography/magnetic resonance imaging applications. Semin Nucl Med 43:3–10CrossRef von Schulthess GK, Kuhn FP, Kaufmann P, Veit-Haibach P (2013) Clinical positron emission tomography/magnetic resonance imaging applications. Semin Nucl Med 43:3–10CrossRef
20.
Zurück zum Zitat Hofmann M, Steinke F, Scheel V, et al. (2008) MRI-based attenuation correction for PET/MRI: a novel approach combining pattern recognition and atlas registration. J Nucl Med 49:1875–1883CrossRefPubMed Hofmann M, Steinke F, Scheel V, et al. (2008) MRI-based attenuation correction for PET/MRI: a novel approach combining pattern recognition and atlas registration. J Nucl Med 49:1875–1883CrossRefPubMed
22.
Zurück zum Zitat Teixera SR, Kohan AA, Paspulati RM, Rong R, Herrmann KA (2014) Potential role of positron emission tomography/magnetic resonance imaging in gastrointestinal and abdominal malignancies: preliminary experience. Semin Roentgenol 49:321–333CrossRefPubMed Teixera SR, Kohan AA, Paspulati RM, Rong R, Herrmann KA (2014) Potential role of positron emission tomography/magnetic resonance imaging in gastrointestinal and abdominal malignancies: preliminary experience. Semin Roentgenol 49:321–333CrossRefPubMed
23.
Zurück zum Zitat Nensa F, Beiderwellen K, Heusch P, Wetter A (2014) Clinical applications of PET/MRI: current status and future perspectives. Diagn Interv Radiol 20:438–447PubMedCentralCrossRefPubMed Nensa F, Beiderwellen K, Heusch P, Wetter A (2014) Clinical applications of PET/MRI: current status and future perspectives. Diagn Interv Radiol 20:438–447PubMedCentralCrossRefPubMed
24.
Zurück zum Zitat Crocetti L, Lencioni R, Debeni S, et al. (2008) Targeting liver lesions for radiofrequency ablation: an experimental feasibility study using a CT-US fusion imaging system. Invest Radiol 43:33–39CrossRefPubMed Crocetti L, Lencioni R, Debeni S, et al. (2008) Targeting liver lesions for radiofrequency ablation: an experimental feasibility study using a CT-US fusion imaging system. Invest Radiol 43:33–39CrossRefPubMed
25.
Zurück zum Zitat Di Mauro E, Solbiati M, De Beni S, et al. (2013) Virtual navigator real-time ultrasound fusion imaging with positron emission tomography for liver interventions. Conf Proc IEEE Eng Med Biol Soc 2013:1406–1409PubMed Di Mauro E, Solbiati M, De Beni S, et al. (2013) Virtual navigator real-time ultrasound fusion imaging with positron emission tomography for liver interventions. Conf Proc IEEE Eng Med Biol Soc 2013:1406–1409PubMed
26.
Zurück zum Zitat Wood BJ, Zhang H, Durrani A, et al. (2005) Navigation with electromagnetic tracking for interventional radiology procedures: a feasibility study. J Vasc Interv Radiol 6:493–505CrossRef Wood BJ, Zhang H, Durrani A, et al. (2005) Navigation with electromagnetic tracking for interventional radiology procedures: a feasibility study. J Vasc Interv Radiol 6:493–505CrossRef
27.
Zurück zum Zitat Racadio JM, Babic D, Homan R, et al. (2007) Live 3D guidance in the interventional radiology suite. AJR Am J Roentgenol 189:357–364CrossRef Racadio JM, Babic D, Homan R, et al. (2007) Live 3D guidance in the interventional radiology suite. AJR Am J Roentgenol 189:357–364CrossRef
28.
Zurück zum Zitat Tam A, Mohamed A, Pfister M, Rohm E, Wallace MJ (2009) C-arm cone beam computed tomographic needle path overlay for fluoroscopic-guided placement of translumbar central venous catheters. Cardiovasc Intervent Radiol 32:820–824CrossRefPubMed Tam A, Mohamed A, Pfister M, Rohm E, Wallace MJ (2009) C-arm cone beam computed tomographic needle path overlay for fluoroscopic-guided placement of translumbar central venous catheters. Cardiovasc Intervent Radiol 32:820–824CrossRefPubMed
29.
Zurück zum Zitat Kim SK, Choi HJ, Park SY, et al. (2009) Additional value of MR/PET fusion compared with PET/CT in the detection of lymph node metastases in cervical cancer patients. Eur J Cancer 45:2103–2109CrossRefPubMed Kim SK, Choi HJ, Park SY, et al. (2009) Additional value of MR/PET fusion compared with PET/CT in the detection of lymph node metastases in cervical cancer patients. Eur J Cancer 45:2103–2109CrossRefPubMed
30.
Zurück zum Zitat Kitajima K, Suenaga Y, Ueno Y, et al. (2014) Fusion of PET and MRI for staging of uterine cervical cancer: comparison with contrast-enhanced (18)F-FDG PET/CT and pelvic MRI. Clin Imaging 38:464–469CrossRefPubMed Kitajima K, Suenaga Y, Ueno Y, et al. (2014) Fusion of PET and MRI for staging of uterine cervical cancer: comparison with contrast-enhanced (18)F-FDG PET/CT and pelvic MRI. Clin Imaging 38:464–469CrossRefPubMed
31.
Zurück zum Zitat Beer AJ, Eiber M, Souvatzoglou M, et al. (2011) Restricted water diffusibility as measured by diffusion-weighted MR imaging and choline uptake in (11)C-choline PET/CT are correlated in pelvic lymph nodes in patients with prostate cancer. Mol Imaging Biol 13:352–361CrossRefPubMed Beer AJ, Eiber M, Souvatzoglou M, et al. (2011) Restricted water diffusibility as measured by diffusion-weighted MR imaging and choline uptake in (11)C-choline PET/CT are correlated in pelvic lymph nodes in patients with prostate cancer. Mol Imaging Biol 13:352–361CrossRefPubMed
32.
Zurück zum Zitat Schreiter NF, Nogami M, Steffen I, et al. (2012) Evaluation of the potential of PET-MRI fusion for detection of liver metastases in patients with neuroendocrine tumours. Eur Radiol 22:458–467CrossRefPubMed Schreiter NF, Nogami M, Steffen I, et al. (2012) Evaluation of the potential of PET-MRI fusion for detection of liver metastases in patients with neuroendocrine tumours. Eur Radiol 22:458–467CrossRefPubMed
33.
Zurück zum Zitat Beiderwellen K, Gomez B, Buchbender C, et al. (2013) Depiction and characterization of liver lesions in whole body [18F]-FDG PET/MRI. Eur J Radiol 82:669–675CrossRef Beiderwellen K, Gomez B, Buchbender C, et al. (2013) Depiction and characterization of liver lesions in whole body [18F]-FDG PET/MRI. Eur J Radiol 82:669–675CrossRef
34.
Zurück zum Zitat Reiner CS, Stolzmann P, Husmann L, et al. (2014) Protocol requirements and diagnostic value of PET/MR imaging for liver metastasis detection. Eur J Nucl Med Mol Imaging 41:649–658CrossRefPubMed Reiner CS, Stolzmann P, Husmann L, et al. (2014) Protocol requirements and diagnostic value of PET/MR imaging for liver metastasis detection. Eur J Nucl Med Mol Imaging 41:649–658CrossRefPubMed
35.
Zurück zum Zitat Wetter A, Nensa F, Schenck M, et al. (2014) Combined PET imaging and diffusion-weighted imaging of intermediate and high-risk primary prostate carcinomas with simultaneous [18F] choline PET/MRI. PLoS One 9:101571CrossRef Wetter A, Nensa F, Schenck M, et al. (2014) Combined PET imaging and diffusion-weighted imaging of intermediate and high-risk primary prostate carcinomas with simultaneous [18F] choline PET/MRI. PLoS One 9:101571CrossRef
36.
Zurück zum Zitat Hartenbach M, Hartenbach S, Bechtloff W, et al. (2014) Combined PET/MRI improves diagnostic accuracy in patients with prostate cancer: a prospective diagnostic trial. Clin Cancer Res 20:3244–3253CrossRefPubMed Hartenbach M, Hartenbach S, Bechtloff W, et al. (2014) Combined PET/MRI improves diagnostic accuracy in patients with prostate cancer: a prospective diagnostic trial. Clin Cancer Res 20:3244–3253CrossRefPubMed
37.
Zurück zum Zitat Wetter A, Lipponer C, Nensa F, et al. (2014) Quantitative evaluation of bone metastases from prostate cancer with simultaneous [18F] choline PET/MRI: combined SUV and ADC analysis. Ann Nucl Med 28:405–410CrossRefPubMed Wetter A, Lipponer C, Nensa F, et al. (2014) Quantitative evaluation of bone metastases from prostate cancer with simultaneous [18F] choline PET/MRI: combined SUV and ADC analysis. Ann Nucl Med 28:405–410CrossRefPubMed
38.
Zurück zum Zitat Wetter A, Lipponer C, Nensa F, et al. (2014) Evaluation of the PET component of simultaneous [(18)F]choline PET/MRI in prostate cancer: comparison with [(18)F]choline PET/CT. Eur J Nucl Med Mol Imaging 41:79–88CrossRefPubMed Wetter A, Lipponer C, Nensa F, et al. (2014) Evaluation of the PET component of simultaneous [(18)F]choline PET/MRI in prostate cancer: comparison with [(18)F]choline PET/CT. Eur J Nucl Med Mol Imaging 41:79–88CrossRefPubMed
39.
Zurück zum Zitat Wetter A, Lipponer C, Nensa F, et al. (2013) Simultaneous 18F choline positron emission tomography/magnetic resonance imaging of the prostate: initial results. Invest Radiol 48:256–262CrossRefPubMed Wetter A, Lipponer C, Nensa F, et al. (2013) Simultaneous 18F choline positron emission tomography/magnetic resonance imaging of the prostate: initial results. Invest Radiol 48:256–262CrossRefPubMed
40.
Zurück zum Zitat Arce-Calisaya P, Souvatzoglou M, Eiber M, et al. (2013) Sensitivity of PET/MRI to detect recurrence of prostate cancer. Eur J Nucl Med Mol Imaging 40:799CrossRefPubMed Arce-Calisaya P, Souvatzoglou M, Eiber M, et al. (2013) Sensitivity of PET/MRI to detect recurrence of prostate cancer. Eur J Nucl Med Mol Imaging 40:799CrossRefPubMed
41.
Zurück zum Zitat Paparo F, Piccardo A, Bacigalupo L, et al. (2015) Value of bimodal (18)F-choline-PET/MRI and trimodal (18)F-choline-PET/MRI/TRUS for the assessment of prostate cancer recurrence after radiation therapy and radical prostatectomy. Abdom Imaging. doi:10.1007/s00261-014-0345-0 Paparo F, Piccardo A, Bacigalupo L, et al. (2015) Value of bimodal (18)F-choline-PET/MRI and trimodal (18)F-choline-PET/MRI/TRUS for the assessment of prostate cancer recurrence after radiation therapy and radical prostatectomy. Abdom Imaging. doi:10.​1007/​s00261-014-0345-0
42.
Zurück zum Zitat Kitajima K, Suenaga Y, Ueno Y, et al. (2014) Value of fusion of PET and MRI in the detection of intra-pelvic recurrence of gynecological tumor: comparison with 18F-FDG contrast-enhanced PET/CT and pelvic MRI. Ann Nucl Med. 28:25–32PubMedCentralCrossRefPubMed Kitajima K, Suenaga Y, Ueno Y, et al. (2014) Value of fusion of PET and MRI in the detection of intra-pelvic recurrence of gynecological tumor: comparison with 18F-FDG contrast-enhanced PET/CT and pelvic MRI. Ann Nucl Med. 28:25–32PubMedCentralCrossRefPubMed
43.
44.
Zurück zum Zitat Carlson SK, Bender CE, Classic KL, et al. (2001) Benefits and safety of CT fluoroscopy in interventional radiologic procedures. Radiology 219:515–520CrossRefPubMed Carlson SK, Bender CE, Classic KL, et al. (2001) Benefits and safety of CT fluoroscopy in interventional radiologic procedures. Radiology 219:515–520CrossRefPubMed
45.
Zurück zum Zitat Liu FY, Yu XL, Liang P, et al. (2012) Microwave ablation assisted by a real-time virtual navigation system for hepatocellular carcinoma undetectable by conventional ultrasonography. Eur J Radiol 81:1455–1459CrossRefPubMed Liu FY, Yu XL, Liang P, et al. (2012) Microwave ablation assisted by a real-time virtual navigation system for hepatocellular carcinoma undetectable by conventional ultrasonography. Eur J Radiol 81:1455–1459CrossRefPubMed
46.
Zurück zum Zitat Kobayashi K, Bhargava P, Raja S, et al. (2012) Image-guided biopsy: what the interventional radiologist needs to know about PET/CT. Radiographics 32:1483–1501CrossRefPubMed Kobayashi K, Bhargava P, Raja S, et al. (2012) Image-guided biopsy: what the interventional radiologist needs to know about PET/CT. Radiographics 32:1483–1501CrossRefPubMed
47.
Zurück zum Zitat Tatli S, Gerbaudo VH, Mamede M, et al. (2010) Abdominal masses sampled at PET/CT-guided percutaneous biopsy: initial experience with registration of prior PET/CT images. Radiology 256:305–311CrossRefPubMed Tatli S, Gerbaudo VH, Mamede M, et al. (2010) Abdominal masses sampled at PET/CT-guided percutaneous biopsy: initial experience with registration of prior PET/CT images. Radiology 256:305–311CrossRefPubMed
48.
Zurück zum Zitat Tatli S, Gerbaudo VH, Feeley CM, et al. (2011) PET/CT-guided percutaneous biopsy of abdominal masses: initial experience. J Vasc Interv Radiol 22:507–514CrossRefPubMed Tatli S, Gerbaudo VH, Feeley CM, et al. (2011) PET/CT-guided percutaneous biopsy of abdominal masses: initial experience. J Vasc Interv Radiol 22:507–514CrossRefPubMed
49.
Zurück zum Zitat Gupta S, Madoff DC (2007) Image-guided percutaneous needle biopsy in cancer diagnosis and staging. Tech Vasc Interv Radiol 10:88–101CrossRefPubMed Gupta S, Madoff DC (2007) Image-guided percutaneous needle biopsy in cancer diagnosis and staging. Tech Vasc Interv Radiol 10:88–101CrossRefPubMed
50.
Zurück zum Zitat Ewertsen C (2010) Image fusion between ultrasonography and CT, MRI or PET/CT for image guidance and intervention - a theoretical and clinical study. Dan Med Bull 57:4172 Ewertsen C (2010) Image fusion between ultrasonography and CT, MRI or PET/CT for image guidance and intervention - a theoretical and clinical study. Dan Med Bull 57:4172
51.
Zurück zum Zitat Ewertsen C, Henriksen BM, Torp-Pedersen S, Bachmann Nielsen M (2011) Characterization by biopsy or CEUS of liver lesions guided by image fusion between ultrasonography and CT, PET/CT or MRI. Ultraschall Med 32:191–197CrossRefPubMed Ewertsen C, Henriksen BM, Torp-Pedersen S, Bachmann Nielsen M (2011) Characterization by biopsy or CEUS of liver lesions guided by image fusion between ultrasonography and CT, PET/CT or MRI. Ultraschall Med 32:191–197CrossRefPubMed
52.
Zurück zum Zitat Venkatesan AM, Kadoury S, Abi-Jaoudeh N, et al. (2011) Real-time FDG PET guidance during biopsies and radiofrequency ablation using multimodality fusion with electromagnetic navigation. Radiology 260:848–856PubMedCentralCrossRefPubMed Venkatesan AM, Kadoury S, Abi-Jaoudeh N, et al. (2011) Real-time FDG PET guidance during biopsies and radiofrequency ablation using multimodality fusion with electromagnetic navigation. Radiology 260:848–856PubMedCentralCrossRefPubMed
53.
Zurück zum Zitat Krücker J, Xu S, Venkatesan A, et al. (2011) Clinical utility of real-time fusion guidance for biopsy and ablation. J Vasc Interv Radiol 22:515–524PubMedCentralCrossRefPubMed Krücker J, Xu S, Venkatesan A, et al. (2011) Clinical utility of real-time fusion guidance for biopsy and ablation. J Vasc Interv Radiol 22:515–524PubMedCentralCrossRefPubMed
54.
Zurück zum Zitat de Rooij M, Hamoen EH, Fütterer JJ, Barentsz JO, Rovers MM (2014) Accuracy of multiparametric MRI for prostate cancer detection: a meta-analysis. AJR Am J Roentgenol 202:343–351CrossRefPubMed de Rooij M, Hamoen EH, Fütterer JJ, Barentsz JO, Rovers MM (2014) Accuracy of multiparametric MRI for prostate cancer detection: a meta-analysis. AJR Am J Roentgenol 202:343–351CrossRefPubMed
55.
Zurück zum Zitat Logan JK, Rais-Bahrami S, Turkbey B, et al. (2014) Current status of magnetic resonance imaging (MRI) and ultrasonography fusion software platforms for guidance of prostate biopsies. BJU Int 114:641–652CrossRefPubMed Logan JK, Rais-Bahrami S, Turkbey B, et al. (2014) Current status of magnetic resonance imaging (MRI) and ultrasonography fusion software platforms for guidance of prostate biopsies. BJU Int 114:641–652CrossRefPubMed
57.
Zurück zum Zitat Siddiqui MM, Rais-Bahrami S, Turkbey B, et al. (2015) Comparison of MR/ultrasound fusion-guided biopsy with ultrasound-guided biopsy for the diagnosis of prostate cancer. JAMA 313:390–397PubMedCentralCrossRefPubMed Siddiqui MM, Rais-Bahrami S, Turkbey B, et al. (2015) Comparison of MR/ultrasound fusion-guided biopsy with ultrasound-guided biopsy for the diagnosis of prostate cancer. JAMA 313:390–397PubMedCentralCrossRefPubMed
Metadaten
Titel
Multimodality fusion imaging in abdominal and pelvic malignancies: current applications and future perspectives
verfasst von
Francesco Paparo
Arnoldo Piccardo
Lorenzo Bacigalupo
Riccardo Piccazzo
Ludovica Rollandi
Athena Galletto Pregliasco
Marco Filauro
Andrea DeCensi
Gian Andrea Rollandi
Publikationsdatum
01.10.2015
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 7/2015
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-015-0435-7

Weitere Artikel der Ausgabe 7/2015

Abdominal Radiology 7/2015 Zur Ausgabe

Classics in Abdominal Imaging

The “bunch of grapes” sign

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.