Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 6/2012

01.08.2012 | Original paper

Optical coherence tomographic comparison of neointimal coverage between sirolimus- and resolute zotarolimus-eluting stents at 9 months after stent implantation

verfasst von: Jung-Sun Kim, Jin-Sun Kim, Dong-Ho Shin, Byeong-Keuk Kim, Young-Guk Ko, Donghoon Choi, Yangsoo Jang, Myeong-Ki Hong

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 6/2012

Einloggen, um Zugang zu erhalten

Abstract

The Resolute zotarolimus-eluting stent (ZES-R) has a thinner stent strut with biocompatible polymer than first generation drug-eluting stents. However, minimal optical coherence tomography (OCT) data exists about vascular responses after ZES-R implantation. This study investigated OCT findings in ZES-R implantation and compared them to those in sirolimus-eluting stent (SES) implantation. A total of 123 lesions (43 ZES-R and 80 SES) in 111 patients were evaluated with OCT at 9 months after stent implantation. Strut apposition, neointimal hyperplasia (NIH) thickness, and stent coverage on each stent strut were evaluated. Mean NIH thickness was significantly greater in ZES-R-treated lesions than in SES-treated lesions (166 ± 73 μm vs. 96 ± 63 μm, respectively, P < 0.001). The percentage of uncovered strut was significantly lower in ZES-R-treated lesions than in SES-treated lesions (4.4 ± 4.8% vs. 10.3 ± 13.2%, respectively, P = 0.05). The percentage of malapposed struts was also significantly lower in ZES-R-treated than in SES-treated lesions (0.1 ± 0.4% vs. 1.5 ± 4.2%, respectively, P = 0.002). Intracoronary thrombus was less frequently detected in ZES-R-treated lesions (4.7% vs. 30.0%, respectively, P = 0.001). ZES-R showed a lower incidence of uncovered or malapposed stent struts and intracoronary thrombus than SES at 9-month follow-up OCT examination. Compared with SES, ZES-R may elicit more favorable vascular responses at the expense of an increased neointimal proliferation.
Literatur
1.
Zurück zum Zitat Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O’Shaughnessy C, Caputo RP, Kereiakes DJ, Williams DO, Teirstein PS, Jaeger JL, Kuntz RE, for the SIRIUS investigators (2003) Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 349:1315–1323 Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O’Shaughnessy C, Caputo RP, Kereiakes DJ, Williams DO, Teirstein PS, Jaeger JL, Kuntz RE, for the SIRIUS investigators (2003) Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 349:1315–1323
2.
Zurück zum Zitat Stone GW, Ellis SG, Cox DA, Hermiller J, O’Shaughnessy C, Mann JT, Turco M, Caputo R, Bergin P, Greenberg J, Popma JJ, Russell ME, TAXUS-IV investigators (2004) A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 350:221–231 Stone GW, Ellis SG, Cox DA, Hermiller J, O’Shaughnessy C, Mann JT, Turco M, Caputo R, Bergin P, Greenberg J, Popma JJ, Russell ME, TAXUS-IV investigators (2004) A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 350:221–231
3.
Zurück zum Zitat Iakovou I, Schmidt T, Bonizzoni E, Ge L, Sangiorgi GM, Stankovic G, Airoldi F, Chieffo A, Montorfano M, Carlino M, Michev I, Corvaja N, Briguori C, Gerckens U, Grube E, Colombo A (2005) Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 293:2126–2130PubMedCrossRef Iakovou I, Schmidt T, Bonizzoni E, Ge L, Sangiorgi GM, Stankovic G, Airoldi F, Chieffo A, Montorfano M, Carlino M, Michev I, Corvaja N, Briguori C, Gerckens U, Grube E, Colombo A (2005) Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 293:2126–2130PubMedCrossRef
4.
Zurück zum Zitat Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Gold HK, Virmani R (2007) Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115:2435–2441PubMedCrossRef Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Gold HK, Virmani R (2007) Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115:2435–2441PubMedCrossRef
5.
Zurück zum Zitat Meredith IT, Worthley S, Whitbourn R, Walters DL, McClean D, Horrigan M, Popma JJ, Cutlip DE, DePaoli A, Negoita M, Fitzgerald PJ, RESOLUTE investigators (2009) Clinical and angiographic results with the next-generation resolute stent system: a prospective, multicenter, first-in-human trial. JACC Cardiovasc Interv 2:977–985PubMedCrossRef Meredith IT, Worthley S, Whitbourn R, Walters DL, McClean D, Horrigan M, Popma JJ, Cutlip DE, DePaoli A, Negoita M, Fitzgerald PJ, RESOLUTE investigators (2009) Clinical and angiographic results with the next-generation resolute stent system: a prospective, multicenter, first-in-human trial. JACC Cardiovasc Interv 2:977–985PubMedCrossRef
6.
Zurück zum Zitat Serruys PW, Silber S, Garg S, van Geuns RJ, Richardt G, Buszman PE, Kelbaek H, van Boven AJ, Hofma SH, Linke A, Klauss V, Wijns W, Macaya C, Garot P, DiMario C, Manoharan G, Kornowski R, Ischinger T, Bartorelli A, Ronden J, Bressers M, Gobbens P, Negoita M, van Leeuwen F, Windecker S (2010) Comparison of zotarolimus-eluting and everolimus-eluting coronary stents. N Engl J Med 363:136–146PubMedCrossRef Serruys PW, Silber S, Garg S, van Geuns RJ, Richardt G, Buszman PE, Kelbaek H, van Boven AJ, Hofma SH, Linke A, Klauss V, Wijns W, Macaya C, Garot P, DiMario C, Manoharan G, Kornowski R, Ischinger T, Bartorelli A, Ronden J, Bressers M, Gobbens P, Negoita M, van Leeuwen F, Windecker S (2010) Comparison of zotarolimus-eluting and everolimus-eluting coronary stents. N Engl J Med 363:136–146PubMedCrossRef
7.
Zurück zum Zitat Kim U, Kim JS, Lee JM, Son JW, Kim J, Ko YG, Choi D, Jang Y (2010) The initial extent of malposition in ST-elevation myocardial infarction treated with drug-eluting stent: the usefulness of optical coherence tomography. Yonsei Med J 51:332–338PubMedCrossRef Kim U, Kim JS, Lee JM, Son JW, Kim J, Ko YG, Choi D, Jang Y (2010) The initial extent of malposition in ST-elevation myocardial infarction treated with drug-eluting stent: the usefulness of optical coherence tomography. Yonsei Med J 51:332–338PubMedCrossRef
8.
Zurück zum Zitat Kim JS, Hong MK, Fan C, Kim TH, Shim JM, Park SM, Ko YG, Choi D, Jang Y (2010) Intracoronary thrombus formation after drug-eluting stents implantation: optical coherence tomographic study. Am Heart J 159:278–283PubMedCrossRef Kim JS, Hong MK, Fan C, Kim TH, Shim JM, Park SM, Ko YG, Choi D, Jang Y (2010) Intracoronary thrombus formation after drug-eluting stents implantation: optical coherence tomographic study. Am Heart J 159:278–283PubMedCrossRef
9.
Zurück zum Zitat Takano M, Inami S, Jang IK, Yamamoto M, Murakami D, Seimiya K, Ohba T, Mizuno K (2007) Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. Am J Cardiol 99:1033–1038PubMedCrossRef Takano M, Inami S, Jang IK, Yamamoto M, Murakami D, Seimiya K, Ohba T, Mizuno K (2007) Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. Am J Cardiol 99:1033–1038PubMedCrossRef
10.
Zurück zum Zitat Tanigawa J, Barlis P, De Mario C (2007) Intravascular optical coherence tomography: optimisation of image acquisition and quantitative assessment of stent strut apposition. EuroInterv 3:127–136 Tanigawa J, Barlis P, De Mario C (2007) Intravascular optical coherence tomography: optimisation of image acquisition and quantitative assessment of stent strut apposition. EuroInterv 3:127–136
11.
Zurück zum Zitat Kim JS, Jang IK, Kim JS, Kim TH, Takano M, Kume T, Hur NW, Ko YG, Choi D, Hong MK, Jang Y (2009) Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents. Heart 95:1907–1912PubMedCrossRef Kim JS, Jang IK, Kim JS, Kim TH, Takano M, Kume T, Hur NW, Ko YG, Choi D, Hong MK, Jang Y (2009) Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents. Heart 95:1907–1912PubMedCrossRef
12.
Zurück zum Zitat Kume T, Akasaka T, Kawamoto T, Ogasawara Y, Watanabe N, Toyota E, Neishi Y, Sukmawan R, Sadahira Y, Yoshida K (2006) Assessment of coronary arterial thrombus by optical coherence tomography. Am J Cardiol 97:1713–1717PubMedCrossRef Kume T, Akasaka T, Kawamoto T, Ogasawara Y, Watanabe N, Toyota E, Neishi Y, Sukmawan R, Sadahira Y, Yoshida K (2006) Assessment of coronary arterial thrombus by optical coherence tomography. Am J Cardiol 97:1713–1717PubMedCrossRef
13.
Zurück zum Zitat Kim JS, Kim TH, Fan C, Lee JM, Kim W, Ko YG, Choi DH, Hong MK, Jang Y (2010) Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxel-eluting stents using optical coherence tomography at 9 months after implantation. Circ J 74:320–326PubMedCrossRef Kim JS, Kim TH, Fan C, Lee JM, Kim W, Ko YG, Choi DH, Hong MK, Jang Y (2010) Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxel-eluting stents using optical coherence tomography at 9 months after implantation. Circ J 74:320–326PubMedCrossRef
14.
Zurück zum Zitat Kim JS, Jang IK, Fan C, Kim TH, Kim JS, Park SM, Choi EY, Lee SH, Ko YG, Choi D, Hong MK, Jang Y (2009) Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial. JACC Cardiovasc Interv 2:1240–1247PubMedCrossRef Kim JS, Jang IK, Fan C, Kim TH, Kim JS, Park SM, Choi EY, Lee SH, Ko YG, Choi D, Hong MK, Jang Y (2009) Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial. JACC Cardiovasc Interv 2:1240–1247PubMedCrossRef
15.
Zurück zum Zitat Udipi K, Melder RJ, Chen M, Cheng P, Hezi-Yamit A, Sullivan C, Wong J, Wilcox J (2007) The next generation endeavor resolute stent: role of the BioLinx Polymer System. EuroInterv 3:137–139 Udipi K, Melder RJ, Chen M, Cheng P, Hezi-Yamit A, Sullivan C, Wong J, Wilcox J (2007) The next generation endeavor resolute stent: role of the BioLinx Polymer System. EuroInterv 3:137–139
16.
Zurück zum Zitat Miyazawa A, Ako J, Hongo Y, Hur SH, Tsujino I, Courtney BK, Hassan AH, Kandzari DE, Honda Y, Fitzgerald PJ, ENDEAVOR III investigators (2008) Comparison of vascular response to zotarolimus-eluting stent versus sirolimus-eluting stent: intravascular ultrasound results from ENDEAVOR III. Am Heart J 155:108–113PubMedCrossRef Miyazawa A, Ako J, Hongo Y, Hur SH, Tsujino I, Courtney BK, Hassan AH, Kandzari DE, Honda Y, Fitzgerald PJ, ENDEAVOR III investigators (2008) Comparison of vascular response to zotarolimus-eluting stent versus sirolimus-eluting stent: intravascular ultrasound results from ENDEAVOR III. Am Heart J 155:108–113PubMedCrossRef
17.
Zurück zum Zitat Waseda K, Miyazawa A, Ako J, Hasegawa T, Tsujino I, Sakurai R, Yock PG, Honda Y, Kandzari DE, Leon MB, Fitzgerald PJ, ENDEAVOR IV trial investigators (2009) Intravascular ultrasound results from the ENDEAVOR IV trial: randomized comparison between zotarolimus- and paclitaxel-eluting stents in patients with coronary artery disease. JACC Cardiovasc Interv 2:779–784PubMedCrossRef Waseda K, Miyazawa A, Ako J, Hasegawa T, Tsujino I, Sakurai R, Yock PG, Honda Y, Kandzari DE, Leon MB, Fitzgerald PJ, ENDEAVOR IV trial investigators (2009) Intravascular ultrasound results from the ENDEAVOR IV trial: randomized comparison between zotarolimus- and paclitaxel-eluting stents in patients with coronary artery disease. JACC Cardiovasc Interv 2:779–784PubMedCrossRef
18.
Zurück zum Zitat Waseda K, Ako J, Yamasaki M, Koizumi T, Ormiston J, Worthley SG, Whitbourn RJ, Walters DL, Honda Y, Meredith IT, Fitzgerald PJ; RESOLUTE trial investigators (2010) Short- and mid-term intravascular ultrasound analysis of the new zotarolimus-eluting stent with durable polymer - results from the RESOLUTE trial. Circ J 74:2097–2102 Waseda K, Ako J, Yamasaki M, Koizumi T, Ormiston J, Worthley SG, Whitbourn RJ, Walters DL, Honda Y, Meredith IT, Fitzgerald PJ; RESOLUTE trial investigators (2010) Short- and mid-term intravascular ultrasound analysis of the new zotarolimus-eluting stent with durable polymer - results from the RESOLUTE trial. Circ J 74:2097–2102
19.
Zurück zum Zitat Choi HH, Kim JS, Ko YG, Hong KS, Kim TH, Kim BK, Ko YG, Choi D, Jang Y, Hong MK. Favorable neointimal coverage in everolimus-eluting stent at 9 month after stent implantation: comparison with sirolimus-eluting stent using optical coherence tomography. Int J Cardiovasc Imag (in press) Choi HH, Kim JS, Ko YG, Hong KS, Kim TH, Kim BK, Ko YG, Choi D, Jang Y, Hong MK. Favorable neointimal coverage in everolimus-eluting stent at 9 month after stent implantation: comparison with sirolimus-eluting stent using optical coherence tomography. Int J Cardiovasc Imag (in press)
20.
Zurück zum Zitat Inoue T, Shite J, Yoon J, Shinke T, Otake H, Sawada T, Kawamori H, Katoh H, Miyoshi N, Yoshino N, Kozuki A, Hariki H, Hirata KI (2011) Optical coherence evaluation for everolimus-eluting stents at 8 months after implantation (Cooperative Study with Korea). Heart 97:1379–1384 Inoue T, Shite J, Yoon J, Shinke T, Otake H, Sawada T, Kawamori H, Katoh H, Miyoshi N, Yoshino N, Kozuki A, Hariki H, Hirata KI (2011) Optical coherence evaluation for everolimus-eluting stents at 8 months after implantation (Cooperative Study with Korea). Heart 97:1379–1384
21.
Zurück zum Zitat Guagliumi G, Costa MA, Sirbu V, Musumeci G, Bezerra HG, Suzuki N, Matiashvili A, Lortkipanidze N, Mihalcsik L, Trivisonno A, Valsecchi O, Mintz GS, Dressler O, Parise H, Maehara A, Cristea E, Lansky AJ, Mehran R, Stone GW (2011) Strut coverage and late malposition with paclitaxel-eluting stents compared with bare metal stents in acute myocardial infarction: optical coherence tomography substudy of the Harmonizing outcomes with revascularization and stents in acute myocardial infarction (HORIZONS-AMI) trial. Circulation 123:274–281PubMedCrossRef Guagliumi G, Costa MA, Sirbu V, Musumeci G, Bezerra HG, Suzuki N, Matiashvili A, Lortkipanidze N, Mihalcsik L, Trivisonno A, Valsecchi O, Mintz GS, Dressler O, Parise H, Maehara A, Cristea E, Lansky AJ, Mehran R, Stone GW (2011) Strut coverage and late malposition with paclitaxel-eluting stents compared with bare metal stents in acute myocardial infarction: optical coherence tomography substudy of the Harmonizing outcomes with revascularization and stents in acute myocardial infarction (HORIZONS-AMI) trial. Circulation 123:274–281PubMedCrossRef
Metadaten
Titel
Optical coherence tomographic comparison of neointimal coverage between sirolimus- and resolute zotarolimus-eluting stents at 9 months after stent implantation
verfasst von
Jung-Sun Kim
Jin-Sun Kim
Dong-Ho Shin
Byeong-Keuk Kim
Young-Guk Ko
Donghoon Choi
Yangsoo Jang
Myeong-Ki Hong
Publikationsdatum
01.08.2012
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 6/2012
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-011-9943-x

Weitere Artikel der Ausgabe 6/2012

The International Journal of Cardiovascular Imaging 6/2012 Zur Ausgabe

„Jeder Fall von plötzlichem Tod muss obduziert werden!“

17.05.2024 Plötzlicher Herztod Nachrichten

Ein signifikanter Anteil der Fälle von plötzlichem Herztod ist genetisch bedingt. Um ihre Verwandten vor diesem Schicksal zu bewahren, sollten jüngere Personen, die plötzlich unerwartet versterben, ausnahmslos einer Autopsie unterzogen werden.

Hirnblutung unter DOAK und VKA ähnlich bedrohlich

17.05.2024 Direkte orale Antikoagulanzien Nachrichten

Kommt es zu einer nichttraumatischen Hirnblutung, spielt es keine große Rolle, ob die Betroffenen zuvor direkt wirksame orale Antikoagulanzien oder Marcumar bekommen haben: Die Prognose ist ähnlich schlecht.

Schlechtere Vorhofflimmern-Prognose bei kleinem linken Ventrikel

17.05.2024 Vorhofflimmern Nachrichten

Nicht nur ein vergrößerter, sondern auch ein kleiner linker Ventrikel ist bei Vorhofflimmern mit einer erhöhten Komplikationsrate assoziiert. Der Zusammenhang besteht nach Daten aus China unabhängig von anderen Risikofaktoren.

Semaglutid bei Herzinsuffizienz: Wie erklärt sich die Wirksamkeit?

17.05.2024 Herzinsuffizienz Nachrichten

Bei adipösen Patienten mit Herzinsuffizienz des HFpEF-Phänotyps ist Semaglutid von symptomatischem Nutzen. Resultiert dieser Benefit allein aus der Gewichtsreduktion oder auch aus spezifischen Effekten auf die Herzinsuffizienz-Pathogenese? Eine neue Analyse gibt Aufschluss.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.