Skip to main content
Erschienen in: Journal of Digital Imaging 4/2004

01.12.2004

Quality Assurance of Clinical MRI Scanners Using ACR MRI Phantom: Preliminary Results

verfasst von: Chien-Chuan Chen, MS, Yung-Liang Wan, MD, Yau-Yau Wai, MD, Ho-Ling Liu, PhD

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 4/2004

Einloggen, um Zugang zu erhalten

Abstract

Clinical magnetic resonance imaging (MRI) scanners play an important role in the diagnosis of diseases and management of patient treatment. Quality assurance (QA) of the clinical MRI scanners is mandatory to obtain optimal images in a modern hospital. In this report, the phantom test for the American College of Radiology (ACR) MRI accreditation is used as the essential part of the MRI QA protocols. Seven important assessments of MR image quality are included as follows: geometric accuracy, high-contrast resolution, slice thickness accuracy, slice position accuracy, image intensity uniformity, percent signal ghosting, and low-contrast object detectability. In addition, signal-to-noise ratio and central frequency are monitored as well. The MRI QA procedures were applied to four clinical MRI scanners in our institute twice within 3 months. According to the QA results, the service engineers were more efficient in solving scanners problems when the ACR phantom test was run.
Literatur
Zurück zum Zitat Covell, MM, Gerashen, DO, Caroson, PL, et al. 1986Automated analysis of multiple performance characteristics in magnetic resonance imaging systemsMed Phys13815823PubMed Covell, MM, Gerashen, DO, Caroson, PL,  et al. 1986Automated analysis of multiple performance characteristics in magnetic resonance imaging systemsMed Phys13815823PubMed
Zurück zum Zitat Kjaer, L, Thomsen, C, Henriksen, O, et al. 1987Evaluation of relaxation time measurements by magnetic resonance imagingA phantom study. Acta Radiol28345351 Kjaer, L, Thomsen, C, Henriksen, O,  et al. 1987Evaluation of relaxation time measurements by magnetic resonance imagingA phantom study. Acta Radiol28345351
Zurück zum Zitat Steudel, A, Traber, F, Krahe, T, et al. 1990Qualitative control over quantitative MR tomography: in vitro and in vivo checks on relaxation time measurementsRofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr152673676CrossRefPubMed Steudel, A, Traber, F, Krahe, T,  et al. 1990Qualitative control over quantitative MR tomography: in vitro and in vivo checks on relaxation time measurementsRofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr152673676CrossRefPubMed
Zurück zum Zitat Duina, A, Mascaro, L, Moretti, R, et al. 1992Results of the quality control of magnetic resonance imagesRadiol Med83276281PubMed Duina, A, Mascaro, L, Moretti, R,  et al. 1992Results of the quality control of magnetic resonance imagesRadiol Med83276281PubMed
Zurück zum Zitat Miller, AJ, Joseph, PM 1993The use of power images to perform quantitative analysis on SNR MR imagesMagn Reson Imaging1110511056PubMed Miller, AJ, Joseph, PM 1993The use of power images to perform quantitative analysis on SNR MR imagesMagn Reson Imaging1110511056PubMed
Zurück zum Zitat Podo, F 1994Quality control in magnetic resonance for clinical useAnn Ist Super Sanita30123137PubMed Podo, F 1994Quality control in magnetic resonance for clinical useAnn Ist Super Sanita30123137PubMed
Zurück zum Zitat Hyde, RJ, Ellis, JH, Gardner, EA, et al. 1994MRI scanner variability studies using a semi-automated analysis systemMagn Reson Imaging1210891097PubMed Hyde, RJ, Ellis, JH, Gardner, EA,  et al. 1994MRI scanner variability studies using a semi-automated analysis systemMagn Reson Imaging1210891097PubMed
Zurück zum Zitat Mascaro, L, Strocchi, S, Colombo, P, et al. 1999Definition criteria for a magnetic resonance quality assurance program: multicenter studyRadiol Med (Torino)97389397 Mascaro, L, Strocchi, S, Colombo, P,  et al. 1999Definition criteria for a magnetic resonance quality assurance program: multicenter studyRadiol Med (Torino)97389397
Zurück zum Zitat Bourel, P, Gibon, D, Coste, E, et al. 1999Automatic quality assessment protocol for MRI equipmentMed Phys2626932700PubMed Bourel, P, Gibon, D, Coste, E,  et al. 1999Automatic quality assessment protocol for MRI equipmentMed Phys2626932700PubMed
Zurück zum Zitat Redpath, TW, Wiggins, CJ 2000Estimating achievable signal-to-noise ratios of MRI transmit-receive coils from radiofrequency power measurements: applications in quality controlPhys Med Biol45217227PubMed Redpath, TW, Wiggins, CJ 2000Estimating achievable signal-to-noise ratios of MRI transmit-receive coils from radiofrequency power measurements: applications in quality controlPhys Med Biol45217227PubMed
Zurück zum Zitat Firbank, MJ, Harrison, RM, Williams, ED 2000Quality assurance for MRI: practical experienceBr J Radiol73376383PubMed Firbank, MJ, Harrison, RM, Williams, ED 2000Quality assurance for MRI: practical experienceBr J Radiol73376383PubMed
Zurück zum Zitat Phantom test guidance for the ACR MRI accreditation program. American College of Radiology, Reston, 1998 Phantom test guidance for the ACR MRI accreditation program. American College of Radiology, Reston, 1998
Zurück zum Zitat MRI quality control manual. American College of Radiology, Reston, 2000 MRI quality control manual. American College of Radiology, Reston, 2000
Metadaten
Titel
Quality Assurance of Clinical MRI Scanners Using ACR MRI Phantom: Preliminary Results
verfasst von
Chien-Chuan Chen, MS
Yung-Liang Wan, MD
Yau-Yau Wai, MD
Ho-Ling Liu, PhD
Publikationsdatum
01.12.2004
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 4/2004
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-004-1023-5

Weitere Artikel der Ausgabe 4/2004

Journal of Digital Imaging 4/2004 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.