Skip to main content
Erschienen in: European Radiology 2/2017

28.05.2016 | Musculoskeletal

Quantitative ultrasound mapping of regional variations in shear wave speeds of the aging Achilles tendon

verfasst von: Laura Chernak Slane, Jack Martin, Ryan DeWall, Darryl Thelen, Kenneth Lee

Erschienen in: European Radiology | Ausgabe 2/2017

Einloggen, um Zugang zu erhalten

Abstract

Objectives

Evaluate the effects of aging on healthy Achilles tendon and aponeurosis shear wave speed (SWS), a quantitative metric which reflects tissue elasticity.

Methods

Shear wave elastography was used to measure spatial variations in Achilles tendon SWS in healthy young (n = 15, 25 ± 4 years), middle-aged (n = 10, 49 ± 4 years) and older (n = 10, 68 ± 5 years) adults. SWS was separately measured in the free Achilles tendon, soleus aponeurosis and gastrocnemius aponeurosis in resting (R), stretched (dorsiflexed 15° from R) and slack (plantarflexed 15° from R) postures.

Results

SWS significantly increased with stretch and varied with age in all tendon regions. Slack free tendon SWS was significantly higher in older adults than young adults (p = 0.025). However, stretched soleus aponeurosis SWS was significantly lower in older adults than young adults (p = 0.01). Stretched gastrocnemius aponeurosis SWS was significantly lower in both middle-aged (p = 0.003) and older (p = 0.001) adults, relative to younger adults.

Conclusion

These results suggest that aging alters spatial variations in Achilles tendon elasticity, which could alter deformations within the triceps surae muscle–tendon units, thus affecting injury potential. The observed location- and posture-dependent variations highlight the importance of controlling ankle posture and imaging location when using shear wave approaches clinically to evaluate tendon disorders.

Key Points

Shear wave elastography shows promise as a clinical quantitative ultrasound-based technique.
Aging induces location-dependent changes in Achilles tendon shear wave speed.
Spatial and postural dependence necessitates careful integration of this approach clinically.
Literatur
1.
Zurück zum Zitat Alfredson H (2003) Chronic midportion Achilles tendinopathy: an update on research and treatment. Clin Sports Med 22:727–741CrossRefPubMed Alfredson H (2003) Chronic midportion Achilles tendinopathy: an update on research and treatment. Clin Sports Med 22:727–741CrossRefPubMed
2.
Zurück zum Zitat Thorpe CT, Udeze CP, Birch HL et al (2013) Capacity for sliding between tendon fascicles decreases with ageing in injury prone equine tendons: a possible mechanism for age-related tendinopathy? Eur Cell Mater 25:48–60CrossRefPubMed Thorpe CT, Udeze CP, Birch HL et al (2013) Capacity for sliding between tendon fascicles decreases with ageing in injury prone equine tendons: a possible mechanism for age-related tendinopathy? Eur Cell Mater 25:48–60CrossRefPubMed
3.
Zurück zum Zitat Couppe C, Hansen P, Kongsgaard M et al (2009) Mechanical properties and collagen cross-linking of the patellar tendon in old and young men. J Appl Physiol 107:880–886CrossRefPubMed Couppe C, Hansen P, Kongsgaard M et al (2009) Mechanical properties and collagen cross-linking of the patellar tendon in old and young men. J Appl Physiol 107:880–886CrossRefPubMed
4.
Zurück zum Zitat Viidik A (1979) Connective tissues - possible implications of the temporal changes for the aging process. Mech Ageing Dev 9:267–285CrossRefPubMed Viidik A (1979) Connective tissues - possible implications of the temporal changes for the aging process. Mech Ageing Dev 9:267–285CrossRefPubMed
5.
Zurück zum Zitat Patterson-Kane JC, Parry DA, Birch HL et al (1997) An age-related study of morphology and cross-link composition of collagen fibrils in the digital flexor tendons of young thoroughbred horses. Connect Tissue Res 36:253–260CrossRefPubMed Patterson-Kane JC, Parry DA, Birch HL et al (1997) An age-related study of morphology and cross-link composition of collagen fibrils in the digital flexor tendons of young thoroughbred horses. Connect Tissue Res 36:253–260CrossRefPubMed
6.
Zurück zum Zitat Csapo R, Malis V, Hodgson J, Sinha S (2014) Age-related greater Achilles tendon compliance is not associated with larger plantar flexor muscle fascicle strains in senior women. J Appl Physiol 116:961–969CrossRefPubMedPubMedCentral Csapo R, Malis V, Hodgson J, Sinha S (2014) Age-related greater Achilles tendon compliance is not associated with larger plantar flexor muscle fascicle strains in senior women. J Appl Physiol 116:961–969CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Onambele GL, Narici MV, Maganaris CN (2006) Calf muscle-tendon properties and postural balance in old age. J Appl Physiol 100:2048–2056CrossRefPubMed Onambele GL, Narici MV, Maganaris CN (2006) Calf muscle-tendon properties and postural balance in old age. J Appl Physiol 100:2048–2056CrossRefPubMed
8.
Zurück zum Zitat Stenroth L, Peltonen J, Cronin NJ et al (2012) Age-related differences in Achilles tendon properties and triceps surae muscle architecture in vivo. J Appl Physiol 113:1537–1544CrossRefPubMed Stenroth L, Peltonen J, Cronin NJ et al (2012) Age-related differences in Achilles tendon properties and triceps surae muscle architecture in vivo. J Appl Physiol 113:1537–1544CrossRefPubMed
9.
Zurück zum Zitat Kubo K, Morimoto M, Komuro T et al (2007) Age-related differences in the properties of the plantar flexor muscles and tendons. Med Sci Sports Exerc 39:541–547CrossRefPubMed Kubo K, Morimoto M, Komuro T et al (2007) Age-related differences in the properties of the plantar flexor muscles and tendons. Med Sci Sports Exerc 39:541–547CrossRefPubMed
10.
Zurück zum Zitat Wood LK, Arruda EM, Brooks SV (2011) Regional stiffening with aging in tibialis anterior tendons of mice occurs independent of changes in collagen fibril morphology. J Appl Physiol 111:999–1006CrossRefPubMedPubMedCentral Wood LK, Arruda EM, Brooks SV (2011) Regional stiffening with aging in tibialis anterior tendons of mice occurs independent of changes in collagen fibril morphology. J Appl Physiol 111:999–1006CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Slane LC, DeWall RJ, Martin JA, Lee KS, Thelen DG (2015) Middle-aged adults exhibit altered spatial variations in Achilles tendon wave speed. Physiol Meas 36:1485–1496 Slane LC, DeWall RJ, Martin JA, Lee KS, Thelen DG (2015) Middle-aged adults exhibit altered spatial variations in Achilles tendon wave speed. Physiol Meas 36:1485–1496
12.
Zurück zum Zitat DeWall RJ, Slane L, Lee KS, Thelen DG (2014) Spatial variations in Achilles tendon shear wave speed. J Biomech 47:2685–2692 DeWall RJ, Slane L, Lee KS, Thelen DG (2014) Spatial variations in Achilles tendon shear wave speed. J Biomech 47:2685–2692
13.
Zurück zum Zitat Arruda EM, Calve S, Dennis RG et al (2006) Regional variation of tibialis anterior tendon mechanics is lost following denervation. J Appl Physiol 101:1113–1117CrossRefPubMed Arruda EM, Calve S, Dennis RG et al (2006) Regional variation of tibialis anterior tendon mechanics is lost following denervation. J Appl Physiol 101:1113–1117CrossRefPubMed
14.
Zurück zum Zitat Pearson SJ, Ritchings T, Mohamed ASA (2014) Regional strain variations in the human patellar tendon. Med Sci Sports Exerc 46:1343–1351CrossRefPubMed Pearson SJ, Ritchings T, Mohamed ASA (2014) Regional strain variations in the human patellar tendon. Med Sci Sports Exerc 46:1343–1351CrossRefPubMed
15.
Zurück zum Zitat De Zordo T, Fink C, Feuchtner GM et al (2009) Real-time sonoelastography findings in healthy Achilles tendons. AJR Am J Roentgenol 193:W134–W138CrossRefPubMed De Zordo T, Fink C, Feuchtner GM et al (2009) Real-time sonoelastography findings in healthy Achilles tendons. AJR Am J Roentgenol 193:W134–W138CrossRefPubMed
16.
Zurück zum Zitat Thorpe CT, Udeze CP, Birch HL et al (2012) Specialization of tendon mechanical properties results from interfascicular differences. J R Soc Interface 9:3108–3117CrossRefPubMedPubMedCentral Thorpe CT, Udeze CP, Birch HL et al (2012) Specialization of tendon mechanical properties results from interfascicular differences. J R Soc Interface 9:3108–3117CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Ooi CC, Richards PJ, Maffulli N et al (2015) A soft patellar tendon on ultrasound elastography is associated with pain and functional deficit in volleyball players. J Sci Med Sport. doi:10.1016/j.jsams.2015.06.003 Ooi CC, Richards PJ, Maffulli N et al (2015) A soft patellar tendon on ultrasound elastography is associated with pain and functional deficit in volleyball players. J Sci Med Sport. doi:10.​1016/​j.​jsams.​2015.​06.​003
18.
Zurück zum Zitat Klauser AS, Miyamoto H, Tamegger M et al (2013) Achilles tendon assessed with sonoelastography: histologic agreement. Radiology 267:837–842CrossRefPubMed Klauser AS, Miyamoto H, Tamegger M et al (2013) Achilles tendon assessed with sonoelastography: histologic agreement. Radiology 267:837–842CrossRefPubMed
19.
Zurück zum Zitat De Zordo T, Lill SR, Fink C et al (2009) Real-time sonoelastography of lateral epicondylitis: comparison of findings between patients and healthy volunteers. Am J Roentgenol 193:180–185CrossRef De Zordo T, Lill SR, Fink C et al (2009) Real-time sonoelastography of lateral epicondylitis: comparison of findings between patients and healthy volunteers. Am J Roentgenol 193:180–185CrossRef
20.
Zurück zum Zitat De Zordo T, Chhem R, Smekal V et al (2010) Real-time sonoelastography: findings in patients with symptomatic Achilles tendons and comparison to healthy volunteers. Ultraschall der Medizin 31:394–400CrossRef De Zordo T, Chhem R, Smekal V et al (2010) Real-time sonoelastography: findings in patients with symptomatic Achilles tendons and comparison to healthy volunteers. Ultraschall der Medizin 31:394–400CrossRef
21.
Zurück zum Zitat Ooi CC, Malliaras P, Schneider ME, Connell DA (2014) “Soft, hard, or just right?” Applications and limitations of axial-strain sonoelastography and shear-wave elastography in the assessment of tendon injuries. Skelet Radiol 43:1–12CrossRef Ooi CC, Malliaras P, Schneider ME, Connell DA (2014) “Soft, hard, or just right?” Applications and limitations of axial-strain sonoelastography and shear-wave elastography in the assessment of tendon injuries. Skelet Radiol 43:1–12CrossRef
22.
Zurück zum Zitat Lacourpaille L, Hug F, Bouillard K et al (2012) Supersonic shear imaging provides a reliable measurement of resting muscle shear elastic modulus. Physiol Meas 33:N19–N28CrossRefPubMed Lacourpaille L, Hug F, Bouillard K et al (2012) Supersonic shear imaging provides a reliable measurement of resting muscle shear elastic modulus. Physiol Meas 33:N19–N28CrossRefPubMed
23.
Zurück zum Zitat Bercoff J, Tanter M, Fink M (2004) Supersonic shear imaging: a new technique for soft tissue elasticity mapping. IEEE Trans Ultrason Ferroelectr Freq Control 51:396–409CrossRefPubMed Bercoff J, Tanter M, Fink M (2004) Supersonic shear imaging: a new technique for soft tissue elasticity mapping. IEEE Trans Ultrason Ferroelectr Freq Control 51:396–409CrossRefPubMed
24.
Zurück zum Zitat Brum J, Bernal M, Gennisson JL, Tanter M (2014) In vivo evaluation of the elastic anisotropy of the human Achilles tendon using shear wave dispersion analysis. Phys Med Biol 59:505–523CrossRefPubMed Brum J, Bernal M, Gennisson JL, Tanter M (2014) In vivo evaluation of the elastic anisotropy of the human Achilles tendon using shear wave dispersion analysis. Phys Med Biol 59:505–523CrossRefPubMed
25.
Zurück zum Zitat Eby SF, Song P, Chen S et al (2013) Validation of shear wave elastography in skeletal muscle. J Biomech 46:2381–2387CrossRefPubMed Eby SF, Song P, Chen S et al (2013) Validation of shear wave elastography in skeletal muscle. J Biomech 46:2381–2387CrossRefPubMed
26.
Zurück zum Zitat Bavu E, Gennisson JL, Couade M et al (2011) Noninvasive in vivo liver fibrosis evaluation using supersonic shear imaging: a clinical study on 113 hepatitis C virus patients. Ultrasound Med Biol 37:1361–1373CrossRefPubMed Bavu E, Gennisson JL, Couade M et al (2011) Noninvasive in vivo liver fibrosis evaluation using supersonic shear imaging: a clinical study on 113 hepatitis C virus patients. Ultrasound Med Biol 37:1361–1373CrossRefPubMed
27.
Zurück zum Zitat Arda K, Ciledag N, Aktas E et al (2011) Quantitative assessment of normal soft-tissue elasticity using shear-wave ultrasound elastography. Am J Roentgenol 197:532–536CrossRef Arda K, Ciledag N, Aktas E et al (2011) Quantitative assessment of normal soft-tissue elasticity using shear-wave ultrasound elastography. Am J Roentgenol 197:532–536CrossRef
28.
29.
Zurück zum Zitat Aubry S, Risson JR, Kastler A et al (2013) Biomechanical properties of the calcaneal tendon in vivo assessed by transient shear wave elastography. Skelet Radiol 42:1143–1150CrossRef Aubry S, Risson JR, Kastler A et al (2013) Biomechanical properties of the calcaneal tendon in vivo assessed by transient shear wave elastography. Skelet Radiol 42:1143–1150CrossRef
30.
Zurück zum Zitat Hug F, Lacourpaille L, Maisetti O, Nordez A (2013) Slack length of gastrocnemius medialis and Achilles tendon occurs at different ankle angles. J Biomech 46:2534–2538CrossRefPubMed Hug F, Lacourpaille L, Maisetti O, Nordez A (2013) Slack length of gastrocnemius medialis and Achilles tendon occurs at different ankle angles. J Biomech 46:2534–2538CrossRefPubMed
31.
Zurück zum Zitat Hawkins D, Lum C, Gaydos D, Dunning R (2009) Dynamic creep and pre-conditioning of the Achilles tendon in-vivo. J Biomech 42:2813–2817CrossRefPubMed Hawkins D, Lum C, Gaydos D, Dunning R (2009) Dynamic creep and pre-conditioning of the Achilles tendon in-vivo. J Biomech 42:2813–2817CrossRefPubMed
32.
Zurück zum Zitat Kuo P-L, Li P-C, Li M-L (2001) Elastic properties of tendon measured by two different approaches. Ultrasound Med Biol 27:1275–1284CrossRefPubMed Kuo P-L, Li P-C, Li M-L (2001) Elastic properties of tendon measured by two different approaches. Ultrasound Med Biol 27:1275–1284CrossRefPubMed
33.
Zurück zum Zitat Royer D, Gennisson JL, Deffieux T, Tanter M (2011) On the elasticity of transverse isotropic soft tissues. J Acoust Soc Am 129:2757–2760CrossRefPubMed Royer D, Gennisson JL, Deffieux T, Tanter M (2011) On the elasticity of transverse isotropic soft tissues. J Acoust Soc Am 129:2757–2760CrossRefPubMed
34.
Zurück zum Zitat Patterson-Kane JC, Firth EC, Goodship AE, Parry DA (1997) Age-related differences in collagen crimp patterns in the superficial digital flexor tendon core region of untrained horses. Aust Vet J 75:39–44CrossRefPubMed Patterson-Kane JC, Firth EC, Goodship AE, Parry DA (1997) Age-related differences in collagen crimp patterns in the superficial digital flexor tendon core region of untrained horses. Aust Vet J 75:39–44CrossRefPubMed
35.
Zurück zum Zitat Turan A, Teber MA, Yakut ZI et al (2015) Sonoelastographıc assessment of the age-related changes of the Achilles tendon. Med Ultrason 17:58–61CrossRefPubMed Turan A, Teber MA, Yakut ZI et al (2015) Sonoelastographıc assessment of the age-related changes of the Achilles tendon. Med Ultrason 17:58–61CrossRefPubMed
36.
Zurück zum Zitat Karamanidis K, Arampatzis A (2005) Mechanical and morphological properties of different muscle-tendon units in the lower extremity and running mechanics: effect of aging and physical activity. J Exp Biol 208:3907–3923CrossRefPubMed Karamanidis K, Arampatzis A (2005) Mechanical and morphological properties of different muscle-tendon units in the lower extremity and running mechanics: effect of aging and physical activity. J Exp Biol 208:3907–3923CrossRefPubMed
37.
Zurück zum Zitat Epstein M, Wong M, Herzog W (2006) Should tendon and aponeurosis be considered in series? J Biomech 39:2020–2025CrossRefPubMed Epstein M, Wong M, Herzog W (2006) Should tendon and aponeurosis be considered in series? J Biomech 39:2020–2025CrossRefPubMed
38.
Zurück zum Zitat Blevins FT, Hecker AT, Bigler GT et al (1994) The effects of donor age and strain rate on the biomechanical properties of bone-patellar tendon-bone allografts. Am J Sports Med 22:328–333CrossRefPubMed Blevins FT, Hecker AT, Bigler GT et al (1994) The effects of donor age and strain rate on the biomechanical properties of bone-patellar tendon-bone allografts. Am J Sports Med 22:328–333CrossRefPubMed
39.
Zurück zum Zitat Vogel HG (1980) Influence of maturation and aging on mechanical and biochemical properties of connective tissue in rats. Mech Ageing Dev 14:283–292CrossRefPubMed Vogel HG (1980) Influence of maturation and aging on mechanical and biochemical properties of connective tissue in rats. Mech Ageing Dev 14:283–292CrossRefPubMed
40.
Zurück zum Zitat Mckean KA, Manson NA, Stanish WD (2006) Musculoskeletal injury in the masters runners. Clin J Sport Med 16:149–154CrossRefPubMed Mckean KA, Manson NA, Stanish WD (2006) Musculoskeletal injury in the masters runners. Clin J Sport Med 16:149–154CrossRefPubMed
41.
Zurück zum Zitat Astrom M, Rausing A (1995) Chronic Achilles tendinopathy. A survey of surgical and histopathologic findings. Clin Orthop Relat Res 316:151–164 Astrom M, Rausing A (1995) Chronic Achilles tendinopathy. A survey of surgical and histopathologic findings. Clin Orthop Relat Res 316:151–164
42.
Zurück zum Zitat Garrett WE (1990) Muscle strain injuries - clinical and basic aspects. Med Sci Sports Exerc 22:436–443CrossRefPubMed Garrett WE (1990) Muscle strain injuries - clinical and basic aspects. Med Sci Sports Exerc 22:436–443CrossRefPubMed
43.
Zurück zum Zitat Kirkendall DT, Garrett WE (2002) Clinical perspectives regarding eccentric muscle injury. Clin Orthop Relat Res S81–S89 Kirkendall DT, Garrett WE (2002) Clinical perspectives regarding eccentric muscle injury. Clin Orthop Relat Res S81–S89
44.
Zurück zum Zitat Speer KP, Lohnes J, Garrett WE Jr (1993) Radiographic imaging of muscle strain injury. Am J Sports Med 21:89–95, discussion 96CrossRefPubMed Speer KP, Lohnes J, Garrett WE Jr (1993) Radiographic imaging of muscle strain injury. Am J Sports Med 21:89–95, discussion 96CrossRefPubMed
45.
Zurück zum Zitat Dewall RJ, Jiang J, Wilson J, Lee KS (2014) Visualizing tendon elasticity in an ex vivo partial tear model. Ultrasound Med Biol 40:158–167CrossRefPubMed Dewall RJ, Jiang J, Wilson J, Lee KS (2014) Visualizing tendon elasticity in an ex vivo partial tear model. Ultrasound Med Biol 40:158–167CrossRefPubMed
46.
Zurück zum Zitat Barbosa DC, Bamber JC, Cosgrove DO, Nassiri D (1986) Ultrasound attenuation measurements to assess the progress of malignant-tumors. Br J Radiol 59:742 Barbosa DC, Bamber JC, Cosgrove DO, Nassiri D (1986) Ultrasound attenuation measurements to assess the progress of malignant-tumors. Br J Radiol 59:742
47.
Zurück zum Zitat Havre RF, Elde E, Gilja OH et al (2008) Freehand real-time elastography: impact of scanning parameters on image quality and in vitro intra- and interobserver validations. Ultrasound Med Biol 34:1638–1650CrossRefPubMed Havre RF, Elde E, Gilja OH et al (2008) Freehand real-time elastography: impact of scanning parameters on image quality and in vitro intra- and interobserver validations. Ultrasound Med Biol 34:1638–1650CrossRefPubMed
Metadaten
Titel
Quantitative ultrasound mapping of regional variations in shear wave speeds of the aging Achilles tendon
verfasst von
Laura Chernak Slane
Jack Martin
Ryan DeWall
Darryl Thelen
Kenneth Lee
Publikationsdatum
28.05.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 2/2017
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-016-4409-0

Weitere Artikel der Ausgabe 2/2017

European Radiology 2/2017 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.