Skip to main content
Erschienen in: Neuroradiology 5/2019

14.03.2019 | Spinal Neuroradiology

Radiation exposure of image-guided intrathecal administration of nusinersen to adult patients with spinal muscular atrophy

verfasst von: D. Oldenburg, N. Guberina, B. Stolte, K. Kizina, E. Stenzel, A. Radbruch, C. Kleinschnitz, T. Hagenacker, M. Forsting, C. Mönninghoff

Erschienen in: Neuroradiology | Ausgabe 5/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To examine diagnostic reference levels (DRL) and achievable doses (AD) of image-guided and size-specific dose estimates (SSDE) and organ and effective doses of CT-guided intrathecal nusinersen administration to adult patients with spinal muscular atrophy (SMA).

Methods

This study involved a total of 60 image-guided intrathecal nusinersen treatments between August 2017 and June 2018. Patient cohort comprised 14 adult patients with the following SMA types: type 2 (n = 9) and type 3 (n = 5) with a mean age of 33.6 years (age range 25–57 years). DRL, AD, SSDE, organ, and effective doses were assessed with a dose-monitoring program based on the Monte Carlo simulation techniques.

Results

DRL and AD for computed tomography are summarised as follows: in terms of CT-dose index (CTDIvol), DRL 56.4 mGy and AD 36.7 mGy; in terms of dose-length product (DLP), DRL 233.1 mGy cm and AD 120.1 mGy cm. DRL and AD for fluoroscopic guidance were distributed as follows: in terms of dose-area product (DAP), DRL 239.1 μGy m2 and AD 135.2 mGy cm2. Mean SSDE was 9.2 mGy. Mean effective dose of the CT-guided injections was 2.5 mSv (median 2.0 mSv, IQR 1.3–3.2 mSv). Highest organ doses in the primary beam of radiation were the small intestine 12.9 mSv, large intestine 9.5 mSv, and ovaries 3.6 mSv.

Conclusion

Radiation exposure of SMA patients measured as DRLs is generally not higher compared with patients without SMA despite severe anatomical hazards. Dose monitoring data may allow clinicians to stratify radiation risk, identify organs at risk, and adopt measures for specific radiation dose reduction.
Literatur
1.
Zurück zum Zitat Hodgson A (2008) Computer-assisted orthopedic surgery. In: Peters T, Cleary K (eds) Image-guided interventions: technology and applications. Springer, Berlin, pp 333–386CrossRef Hodgson A (2008) Computer-assisted orthopedic surgery. In: Peters T, Cleary K (eds) Image-guided interventions: technology and applications. Springer, Berlin, pp 333–386CrossRef
2.
Zurück zum Zitat Kassamali RH, Ladak B (2015) The role of robotics in interventional radiology: current status. Quant Imaging Med Surg 5:340–343PubMedPubMedCentral Kassamali RH, Ladak B (2015) The role of robotics in interventional radiology: current status. Quant Imaging Med Surg 5:340–343PubMedPubMedCentral
3.
Zurück zum Zitat Thanou M (2018) Theranostics and image guided drug delivery. Royal Society of Chemistry, CroydenCrossRef Thanou M (2018) Theranostics and image guided drug delivery. Royal Society of Chemistry, CroydenCrossRef
4.
Zurück zum Zitat Lefebvre S, Bürglen L, Reboullet S et al (1995) Identification and characterization of a spinal muscular atrophy-determining gene. Cell 80(1):155–165CrossRefPubMed Lefebvre S, Bürglen L, Reboullet S et al (1995) Identification and characterization of a spinal muscular atrophy-determining gene. Cell 80(1):155–165CrossRefPubMed
5.
Zurück zum Zitat Mercuri E, Bertini E, Iannaccone ST (2012) Childhood spinal muscular atrophy: controversies and challenges. Lancet Neurol 11(5):443–452CrossRefPubMed Mercuri E, Bertini E, Iannaccone ST (2012) Childhood spinal muscular atrophy: controversies and challenges. Lancet Neurol 11(5):443–452CrossRefPubMed
6.
Zurück zum Zitat Bürglen L, Lefebvre S, Clermont O et al (1996) Structure and organization of the human survival motor neurone (SMN) gene. Genomics 32(3):479–482CrossRefPubMed Bürglen L, Lefebvre S, Clermont O et al (1996) Structure and organization of the human survival motor neurone (SMN) gene. Genomics 32(3):479–482CrossRefPubMed
7.
Zurück zum Zitat Hua Y, Sahashi K, Hung G et al (2010) Antisense correction of SMN2 splicing in the CNS rescues necrosis in a type III SMA mouse model. Genes Dev 24(15):1634–1644CrossRefPubMedPubMedCentral Hua Y, Sahashi K, Hung G et al (2010) Antisense correction of SMN2 splicing in the CNS rescues necrosis in a type III SMA mouse model. Genes Dev 24(15):1634–1644CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Chiriboga CA, Swoboda KJ, Darras BT et al (2016) Results from a phase 1 study of nusinersen (ISIS-SMN(Rx)) in children with spinal muscular atrophy. Neurology 86(10):890–897CrossRefPubMedPubMedCentral Chiriboga CA, Swoboda KJ, Darras BT et al (2016) Results from a phase 1 study of nusinersen (ISIS-SMN(Rx)) in children with spinal muscular atrophy. Neurology 86(10):890–897CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat European Medicines Agency (EMA) in May 2017 European Medicines Agency (EMA) in May 2017
10.
Zurück zum Zitat Finkel RS, Mercuri E, Darras BT et al (2017) Nusinersen versus sham control in infantile-onset spinal muscular atrophy. N Engl J Med 377(18):1723–1732CrossRefPubMed Finkel RS, Mercuri E, Darras BT et al (2017) Nusinersen versus sham control in infantile-onset spinal muscular atrophy. N Engl J Med 377(18):1723–1732CrossRefPubMed
11.
Zurück zum Zitat Mercuri E, Darras BT, Chiriboga CA et al (2018) Nusinersen versus sham control in later-onset spinal muscular atrophy. N Engl J Med 378(7):625–635CrossRefPubMed Mercuri E, Darras BT, Chiriboga CA et al (2018) Nusinersen versus sham control in later-onset spinal muscular atrophy. N Engl J Med 378(7):625–635CrossRefPubMed
12.
Zurück zum Zitat Geary RS, Yu RZ, Levin AA (2001) Pharmacokinetics of phosphorothioate antisense oligodeoxynucleotides. Curr Opin Investig Drugs 2(4):562–573PubMed Geary RS, Yu RZ, Levin AA (2001) Pharmacokinetics of phosphorothioate antisense oligodeoxynucleotides. Curr Opin Investig Drugs 2(4):562–573PubMed
13.
Zurück zum Zitat Sugarman EA, Nagan N, Zhu H et al (2012) Pan-ethnic carrier screening and prenatal diagnosis for spinal muscular atrophy: clinical laboratory analysis of >72,400 specimens. Eur J Hum Genet 20:27–32CrossRefPubMed Sugarman EA, Nagan N, Zhu H et al (2012) Pan-ethnic carrier screening and prenatal diagnosis for spinal muscular atrophy: clinical laboratory analysis of >72,400 specimens. Eur J Hum Genet 20:27–32CrossRefPubMed
14.
Zurück zum Zitat Little MP (2003) Risks associated with ionizing radiation environmental pollution and health. Br Med Bull 68:259–275CrossRefPubMed Little MP (2003) Risks associated with ionizing radiation environmental pollution and health. Br Med Bull 68:259–275CrossRefPubMed
15.
Zurück zum Zitat Rehani MM, Berry M (2000) Radiation doses in computed tomography. The increasing doses of radiation need to be controlled. Br Med J 320:593–594CrossRef Rehani MM, Berry M (2000) Radiation doses in computed tomography. The increasing doses of radiation need to be controlled. Br Med J 320:593–594CrossRef
16.
Zurück zum Zitat Pearce MS, Salotti JA, Little MP et al (2012) Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet 380:499–505CrossRefPubMedPubMedCentral Pearce MS, Salotti JA, Little MP et al (2012) Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet 380:499–505CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Brenner DJ, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357:2277–2284CrossRefPubMed Brenner DJ, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357:2277–2284CrossRefPubMed
18.
Zurück zum Zitat NCRP Report No. 172 (2012) Reference levels and achievable doses in medical and dental imaging: recommendations for the United States. ISBN 978–0–9835450-2-6 NCRP Report No. 172 (2012) Reference levels and achievable doses in medical and dental imaging: recommendations for the United States. ISBN 978–0–9835450-2-6
19.
Zurück zum Zitat Shrimpton PC, Lewis MA, Dunn M (2005) Doses from computed tomography (CT) examinations in the UK- 2003 review. NRPB-W67. ISBN 0-85951-556-7 Shrimpton PC, Lewis MA, Dunn M (2005) Doses from computed tomography (CT) examinations in the UK- 2003 review. NRPB-W67. ISBN 0-85951-556-7
21.
Zurück zum Zitat ICRP (2007) The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann ICRP 37:2–4 ICRP (2007) The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann ICRP 37:2–4
22.
Zurück zum Zitat Guberina N, Forsting M, Suntharalingam S, Nassenstein K, Theysohn J, Ringelstein A, Wetter A (2017) Radiation dose monitoring in the clinical routine. Rofo 189:356–360PubMed Guberina N, Forsting M, Suntharalingam S, Nassenstein K, Theysohn J, Ringelstein A, Wetter A (2017) Radiation dose monitoring in the clinical routine. Rofo 189:356–360PubMed
23.
Zurück zum Zitat Wall BF, Haylock R, Jansen JTM et al (2011) Radiation risk from medical X-ray examinations as a function of the age and sex of the patient. HPA-CRCE-028. ISBN 978-0-85951-709-6 Wall BF, Haylock R, Jansen JTM et al (2011) Radiation risk from medical X-ray examinations as a function of the age and sex of the patient. HPA-CRCE-028. ISBN 978-0-85951-709-6
25.
Zurück zum Zitat Debnam JM, Schellingerhout D, Kumar AJ et al (2009) Multidetector CT-guided lumbar puncture in patients with Cancer. Interv Neuroradiol 15:61–66CrossRefPubMedPubMedCentral Debnam JM, Schellingerhout D, Kumar AJ et al (2009) Multidetector CT-guided lumbar puncture in patients with Cancer. Interv Neuroradiol 15:61–66CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Wagner AL (2004) Selective lumbar nerve root blocks with CT fluoroscopic guidance: technique, results, procedure time, and radiation dose. Am J Neuroradiol 25:1592–1594PubMed Wagner AL (2004) Selective lumbar nerve root blocks with CT fluoroscopic guidance: technique, results, procedure time, and radiation dose. Am J Neuroradiol 25:1592–1594PubMed
27.
28.
Zurück zum Zitat Brook AD, Burns J, Dauer E, Schoendfeld AH, Miller TS (2014) Comparison of CT and fluoroscopic guidance for lumbar puncture in an obese population with prior failed unguided attempt. J Neurointerv Surg 6:324–328CrossRefPubMed Brook AD, Burns J, Dauer E, Schoendfeld AH, Miller TS (2014) Comparison of CT and fluoroscopic guidance for lumbar puncture in an obese population with prior failed unguided attempt. J Neurointerv Surg 6:324–328CrossRefPubMed
30.
Zurück zum Zitat Strauss KJ, Goske MJ, Frush DP, Butler PF, Morrison G (2009) Image gently vendor summit: working together for better estimates of pediatric radiation dose from CT. AJR Am J Roentgenol 192(5):1169–1175CrossRefPubMed Strauss KJ, Goske MJ, Frush DP, Butler PF, Morrison G (2009) Image gently vendor summit: working together for better estimates of pediatric radiation dose from CT. AJR Am J Roentgenol 192(5):1169–1175CrossRefPubMed
31.
Zurück zum Zitat (2002) Pediatr Radiol 32:221–316 (entire issue) (2002) Pediatr Radiol 32:221–316 (entire issue)
32.
Zurück zum Zitat Brenner DJ, Elliston CD, Hall EJ, Berdon WE (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. Am J Roentgenol 176:289–296CrossRef Brenner DJ, Elliston CD, Hall EJ, Berdon WE (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. Am J Roentgenol 176:289–296CrossRef
33.
Zurück zum Zitat Hintenlang KM, Williams JL, Hintenlang DE (2002) A survey of radiation dose associated with pediatric plain-film chest X-ray examination. Pediatr Radiol 32:771–777CrossRefPubMed Hintenlang KM, Williams JL, Hintenlang DE (2002) A survey of radiation dose associated with pediatric plain-film chest X-ray examination. Pediatr Radiol 32:771–777CrossRefPubMed
34.
Zurück zum Zitat Mettler FA, Wiest PW, Locken JA et al (2000) CT scanning: patterns of use and dose. J Radiol Prot 20:353–359CrossRefPubMed Mettler FA, Wiest PW, Locken JA et al (2000) CT scanning: patterns of use and dose. J Radiol Prot 20:353–359CrossRefPubMed
35.
Zurück zum Zitat Andreassi MG, Picano E (2014) Reduction of radiation to children: our responsibility to change. Circulation 130:135–137CrossRefPubMed Andreassi MG, Picano E (2014) Reduction of radiation to children: our responsibility to change. Circulation 130:135–137CrossRefPubMed
36.
Zurück zum Zitat Guberina N, Suntharalingam S, Naßenstein K et al (2018) Verification of organ doses calculated by a dose monitoring software tool based on Monte Carlo simulation in thoracic CT protocols. Acta Radiol 59:322–326CrossRefPubMed Guberina N, Suntharalingam S, Naßenstein K et al (2018) Verification of organ doses calculated by a dose monitoring software tool based on Monte Carlo simulation in thoracic CT protocols. Acta Radiol 59:322–326CrossRefPubMed
37.
Zurück zum Zitat Guberina N, Suntharalingam S, Naßenstein K et al (2016) Clinical evaluation of a dose monitoring software tool based on Monte Carlo simulation in assessment of eye lens doses for cranial CT scans. Neuroradiology 58:955–959CrossRefPubMed Guberina N, Suntharalingam S, Naßenstein K et al (2016) Clinical evaluation of a dose monitoring software tool based on Monte Carlo simulation in assessment of eye lens doses for cranial CT scans. Neuroradiology 58:955–959CrossRefPubMed
Metadaten
Titel
Radiation exposure of image-guided intrathecal administration of nusinersen to adult patients with spinal muscular atrophy
verfasst von
D. Oldenburg
N. Guberina
B. Stolte
K. Kizina
E. Stenzel
A. Radbruch
C. Kleinschnitz
T. Hagenacker
M. Forsting
C. Mönninghoff
Publikationsdatum
14.03.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
Neuroradiology / Ausgabe 5/2019
Print ISSN: 0028-3940
Elektronische ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-019-02189-x

Weitere Artikel der Ausgabe 5/2019

Neuroradiology 5/2019 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Frühe Alzheimertherapie lohnt sich

25.04.2024 AAN-Jahrestagung 2024 Nachrichten

Ist die Tau-Last noch gering, scheint der Vorteil von Lecanemab besonders groß zu sein. Und beginnen Erkrankte verzögert mit der Behandlung, erreichen sie nicht mehr die kognitive Leistung wie bei einem früheren Start. Darauf deuten neue Analysen der Phase-3-Studie Clarity AD.

Viel Bewegung in der Parkinsonforschung

25.04.2024 Parkinson-Krankheit Nachrichten

Neue arznei- und zellbasierte Ansätze, Frühdiagnose mit Bewegungssensoren, Rückenmarkstimulation gegen Gehblockaden – in der Parkinsonforschung tut sich einiges. Auf dem Deutschen Parkinsonkongress ging es auch viel um technische Innovationen.

Demenzkranke durch Antipsychotika vielfach gefährdet

23.04.2024 Demenz Nachrichten

Wenn Demenzkranke aufgrund von Symptomen wie Agitation oder Aggressivität mit Antipsychotika behandelt werden, sind damit offenbar noch mehr Risiken verbunden als bislang angenommen.

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.