Abstract

Background

Fluoroscopy use during ERCP exposes patients and providers to deleterious effects of radiation. Formal training in fluoroscopy/radiation protection is not widely emphasized during therapeutic endoscopy training, and radiation use during GI endoscopy has not previously been characterized in the USA. In this study, we evaluated radiation training, fluoroscopy use patterns, and radiation protection practices among US therapeutic endoscopists.

Methods

An anonymous electronic survey was distributed to US therapeutic endoscopists, and responses were analyzed using descriptive statistics. State-specific requirements for fluoroscopy utilization were determined from state radiologic health branches.

Results

A total of 159 endoscopists (response rate 67.8%) predominantly those working in university hospitals (69.2%) with > 5 years of experience performing ERCP (74.9%) completed the questionnaire. Although the majority of endoscopists (61.6%) reported that they personally controlled fluoroscopy during ERCP, most (56.6%) had not received training on operating their fluoroscopy system. Only a minority (18–31%) of all respondents reported consistently utilizing modifiable fluoroscopy system parameters that minimize patient radiation exposure (pulsed fluoroscopy, frame rate modification or collimation). Endoscopists appear to undertake adequate personal radiation protective measures although use of a dosimeter was not consistent in half of respondents. The majority of states (56.8%) do not have any stated requirement for certification of non-radiologist physicians who intend to operate fluoroscopy.

Conclusions

Most US gastroenterologists performing ERCP have not received formal training in operating their fluoroscopy system or in minimizing radiation exposure to themselves and to their patients. Such formal training should be included in all therapeutic endoscopy training programs, and fluoroscopy system-specific training should be offered at all hospitals.
Literatur
1.
Zurück zum Zitat Ho IK, Cash BD, Cohen H, et al. Radiation exposure in gastroenterology: improving patient and staff protection. Am J Gastroenterol. 2014;109:1180–1194.CrossRefPubMed Ho IK, Cash BD, Cohen H, et al. Radiation exposure in gastroenterology: improving patient and staff protection. Am J Gastroenterol. 2014;109:1180–1194.CrossRefPubMed
2.
Zurück zum Zitat Bouffler S, Silver A, Cox R. Mechanistic and genetic studies of radiation tumorigenesis in the mouse—implications for low dose risk estimation. J Radiol Prot. 2002;22:A11–A16.CrossRefPubMed Bouffler S, Silver A, Cox R. Mechanistic and genetic studies of radiation tumorigenesis in the mouse—implications for low dose risk estimation. J Radiol Prot. 2002;22:A11–A16.CrossRefPubMed
3.
Zurück zum Zitat Jaffe D, Bowden GT. Ionizing radiation as an initiator: effects of proliferation and promotion time on tumor incidence in mice. Cancer Res. 1987;47:6692–6696.PubMed Jaffe D, Bowden GT. Ionizing radiation as an initiator: effects of proliferation and promotion time on tumor incidence in mice. Cancer Res. 1987;47:6692–6696.PubMed
4.
Zurück zum Zitat Richardson DB, Cardis E, Daniels RD, et al. Risk of cancer from occupational exposure to ionising radiation: retrospective cohort study of workers in France, the United Kingdom, and the United States (INWORKS). BMJ. 2015;351:h5359.CrossRefPubMedPubMedCentral Richardson DB, Cardis E, Daniels RD, et al. Risk of cancer from occupational exposure to ionising radiation: retrospective cohort study of workers in France, the United Kingdom, and the United States (INWORKS). BMJ. 2015;351:h5359.CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Schauer DA, Linton OW. National council on radiation protection and measurements report shows substantial medical exposure increase. Radiology. 2009;253:293–296.CrossRefPubMed Schauer DA, Linton OW. National council on radiation protection and measurements report shows substantial medical exposure increase. Radiology. 2009;253:293–296.CrossRefPubMed
6.
Zurück zum Zitat Berrington de Gonzalez A, Mahesh M, Kim KP, et al. Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med. 2009;169:2071–2077.CrossRefPubMed Berrington de Gonzalez A, Mahesh M, Kim KP, et al. Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med. 2009;169:2071–2077.CrossRefPubMed
7.
Zurück zum Zitat Brenner DJ, Hall EJ. Computed tomography—an increasing source of radiation exposure. N Engl J Med. 2007;357:2277–2284.CrossRefPubMed Brenner DJ, Hall EJ. Computed tomography—an increasing source of radiation exposure. N Engl J Med. 2007;357:2277–2284.CrossRefPubMed
8.
Zurück zum Zitat Bhargavan-Chatfield M, Morin RL. The ACR computed tomography dose index registry: the 5 million examination update. J Am Coll Radiol. 2013;10:980–983.CrossRefPubMed Bhargavan-Chatfield M, Morin RL. The ACR computed tomography dose index registry: the 5 million examination update. J Am Coll Radiol. 2013;10:980–983.CrossRefPubMed
9.
Zurück zum Zitat Bruner A, Sutker W, Maxwell G. Minimizing patient exposure to ionizing radiation from computed tomography scans. Proc (Bayl Univ Med Cent). 2009;22:119–123.CrossRef Bruner A, Sutker W, Maxwell G. Minimizing patient exposure to ionizing radiation from computed tomography scans. Proc (Bayl Univ Med Cent). 2009;22:119–123.CrossRef
10.
Zurück zum Zitat Chintapalli KN, Montgomery RS, Hatab M, et al. Radiation dose management: part 1, minimizing radiation dose in CT-guided procedures. AJR Am J Roentgenol. 2012;198:W347–W351.CrossRefPubMed Chintapalli KN, Montgomery RS, Hatab M, et al. Radiation dose management: part 1, minimizing radiation dose in CT-guided procedures. AJR Am J Roentgenol. 2012;198:W347–W351.CrossRefPubMed
11.
Zurück zum Zitat Little BP, Duong PA, Knighton J, et al. A comprehensive CT dose reduction program using the ACR dose index registry. J Am Coll Radiol. 2015;12:1257–1265.CrossRefPubMed Little BP, Duong PA, Knighton J, et al. A comprehensive CT dose reduction program using the ACR dose index registry. J Am Coll Radiol. 2015;12:1257–1265.CrossRefPubMed
12.
Zurück zum Zitat Nolan DJ. Minimizing radiation in diagnostic radiology. Br J Hosp Med. 1991;45:337.PubMed Nolan DJ. Minimizing radiation in diagnostic radiology. Br J Hosp Med. 1991;45:337.PubMed
13.
Zurück zum Zitat Larkin CJ, Workman A, Wright RE, et al. Radiation doses to patients during ERCP. Gastrointest Endosc. 2001;53:161–164.CrossRefPubMed Larkin CJ, Workman A, Wright RE, et al. Radiation doses to patients during ERCP. Gastrointest Endosc. 2001;53:161–164.CrossRefPubMed
14.
Zurück zum Zitat Sethi S, Friedland S, Banerjee S. US survey assessing current ERCP-related radiation protection practices. Gastrointest Endosc. 2015;81:AB352.CrossRef Sethi S, Friedland S, Banerjee S. US survey assessing current ERCP-related radiation protection practices. Gastrointest Endosc. 2015;81:AB352.CrossRef
15.
Zurück zum Zitat Dumonceau JM, Garcia-Fernandez FJ, Verdun FR, et al. Radiation protection in digestive endoscopy: European Society of Digestive Endoscopy (ESGE) guideline. Endoscopy. 2012;44:408–421.CrossRefPubMed Dumonceau JM, Garcia-Fernandez FJ, Verdun FR, et al. Radiation protection in digestive endoscopy: European Society of Digestive Endoscopy (ESGE) guideline. Endoscopy. 2012;44:408–421.CrossRefPubMed
16.
Zurück zum Zitat Adler DG, Lieb JG 2nd, Cohen J, et al. Quality indicators for ERCP. Gastrointest Endosc. 2015;81:54–66.CrossRefPubMed Adler DG, Lieb JG 2nd, Cohen J, et al. Quality indicators for ERCP. Gastrointest Endosc. 2015;81:54–66.CrossRefPubMed
17.
Zurück zum Zitat Adler DG, Lieb JG 2nd, Cohen J, et al. Quality indicators for ERCP. Am J Gastroenterol. 2015;110:91–101.CrossRefPubMed Adler DG, Lieb JG 2nd, Cohen J, et al. Quality indicators for ERCP. Am J Gastroenterol. 2015;110:91–101.CrossRefPubMed
18.
Zurück zum Zitat Weltermann BM, Rock T, Brix G, et al. Multiple procedures and cumulative individual radiation exposure in interventional cardiology: a long-term retrospective study. Eur Radiol. 2015;25:2567–2574.CrossRefPubMed Weltermann BM, Rock T, Brix G, et al. Multiple procedures and cumulative individual radiation exposure in interventional cardiology: a long-term retrospective study. Eur Radiol. 2015;25:2567–2574.CrossRefPubMed
19.
Zurück zum Zitat Morishima Y, Chida K, Katahira Y, et al. Need for radiation safety education for interventional cardiology staff, especially nurses. Acta Cardiol. 2016;71:151–155.CrossRefPubMed Morishima Y, Chida K, Katahira Y, et al. Need for radiation safety education for interventional cardiology staff, especially nurses. Acta Cardiol. 2016;71:151–155.CrossRefPubMed
20.
Zurück zum Zitat Valuckiene Z, Jurenas M, Cibulskaite I. Ionizing radiation exposure in interventional cardiology: current radiation protection practice of invasive cardiology operators in Lithuania. J Radiol Prot. 2016;36:695–708.CrossRefPubMed Valuckiene Z, Jurenas M, Cibulskaite I. Ionizing radiation exposure in interventional cardiology: current radiation protection practice of invasive cardiology operators in Lithuania. J Radiol Prot. 2016;36:695–708.CrossRefPubMed
21.
Zurück zum Zitat Jacobs AK, Babb JD, Hirshfeld JW Jr, et al. Task force 3: training in diagnostic and interventional cardiac catheterization endorsed by the Society for Cardiovascular Angiography and Interventions. J Am Coll Cardiol. 2008;51:355–361.CrossRefPubMed Jacobs AK, Babb JD, Hirshfeld JW Jr, et al. Task force 3: training in diagnostic and interventional cardiac catheterization endorsed by the Society for Cardiovascular Angiography and Interventions. J Am Coll Cardiol. 2008;51:355–361.CrossRefPubMed
22.
Zurück zum Zitat Mettler FA Jr, Bhargavan M, Faulkner K, et al. Radiologic and nuclear medicine studies in the United States and worldwide: frequency, radiation dose, and comparison with other radiation sources—1950–2007. Radiology. 2009;253:520–531.CrossRefPubMed Mettler FA Jr, Bhargavan M, Faulkner K, et al. Radiologic and nuclear medicine studies in the United States and worldwide: frequency, radiation dose, and comparison with other radiation sources—1950–2007. Radiology. 2009;253:520–531.CrossRefPubMed
23.
Zurück zum Zitat Cardis E, Gilbert ES, Carpenter L, et al. Effects of low doses and low dose rates of external ionizing radiation: cancer mortality among nuclear industry workers in three countries. Radiat Res. 1995;142:117–132.CrossRefPubMed Cardis E, Gilbert ES, Carpenter L, et al. Effects of low doses and low dose rates of external ionizing radiation: cancer mortality among nuclear industry workers in three countries. Radiat Res. 1995;142:117–132.CrossRefPubMed
24.
Zurück zum Zitat Huang RJ, Thosani NC, Barakat MT, et al. Evolution in the utilization of biliary interventions in the United States: results of a nationwide longitudinal study from 1998 to 2013. Gastrointest Endosc. 2017;86:319–326.CrossRefPubMedPubMedCentral Huang RJ, Thosani NC, Barakat MT, et al. Evolution in the utilization of biliary interventions in the United States: results of a nationwide longitudinal study from 1998 to 2013. Gastrointest Endosc. 2017;86:319–326.CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat Radiation Risks of Diagnostic Imaging. The Joint Commission Sentinel Event Alert 2011. Radiation Risks of Diagnostic Imaging. The Joint Commission Sentinel Event Alert 2011.
26.
Zurück zum Zitat Barakat MT, Thosani NC, Huang RJ, et al. Effects of a brief educational program on optimization of fluoroscopy to minimize radiation exposure during endoscopic retrograde cholangiopancreatography. Clin Gastroenterol Hepatol. 2017;16:550–557.CrossRefPubMedPubMedCentral Barakat MT, Thosani NC, Huang RJ, et al. Effects of a brief educational program on optimization of fluoroscopy to minimize radiation exposure during endoscopic retrograde cholangiopancreatography. Clin Gastroenterol Hepatol. 2017;16:550–557.CrossRefPubMedPubMedCentral
27.
Zurück zum Zitat Schultz C, Dixon S. SU-F-I-77: radiation dose in cardiac catheterization procedures: impact of a systematic reduction in pulsed fluoroscopy frame rate. Med Phys. 2016;43:3404.CrossRef Schultz C, Dixon S. SU-F-I-77: radiation dose in cardiac catheterization procedures: impact of a systematic reduction in pulsed fluoroscopy frame rate. Med Phys. 2016;43:3404.CrossRef
28.
Zurück zum Zitat Boland GW, Murphy B, Arellano R, et al. Dose reduction in gastrointestinal and genitourinary fluoroscopy: use of grid-controlled pulsed fluoroscopy. AJR Am J Roentgenol. 2000;175:1453–1457.CrossRefPubMed Boland GW, Murphy B, Arellano R, et al. Dose reduction in gastrointestinal and genitourinary fluoroscopy: use of grid-controlled pulsed fluoroscopy. AJR Am J Roentgenol. 2000;175:1453–1457.CrossRefPubMed
29.
Zurück zum Zitat Thosani N, Chen AM, Friedland S, Banerjee S. Prospective evaluation of predictors of increased patient radiation during ERCP: the Stanford ERCP Radiation Safety (Sers) Study. Gastrointest Endosc. 2014;79:AB340–AB341.CrossRef Thosani N, Chen AM, Friedland S, Banerjee S. Prospective evaluation of predictors of increased patient radiation during ERCP: the Stanford ERCP Radiation Safety (Sers) Study. Gastrointest Endosc. 2014;79:AB340–AB341.CrossRef
30.
Zurück zum Zitat Norton I, Bell CJ, Cho S, Kim B, Erdman K. Proceduralist-driven fluoroscopy significantly reduces irradiation during ERCP. Gastrointest Endosc. 2018;87:AB48.CrossRef Norton I, Bell CJ, Cho S, Kim B, Erdman K. Proceduralist-driven fluoroscopy significantly reduces irradiation during ERCP. Gastrointest Endosc. 2018;87:AB48.CrossRef
31.
Zurück zum Zitat Zeng HZ, Liu Q, Chen HL, et al. A pilot single-center prospective randomized trial to assess the short-term effect of a flashing warning light on reducing fluoroscopy time and radiation exposure during ERCP. Gastrointest Endosc. 2018;88:261–266.CrossRefPubMed Zeng HZ, Liu Q, Chen HL, et al. A pilot single-center prospective randomized trial to assess the short-term effect of a flashing warning light on reducing fluoroscopy time and radiation exposure during ERCP. Gastrointest Endosc. 2018;88:261–266.CrossRefPubMed
32.
Zurück zum Zitat Alexandre D, Prieto M, Beaumont F, et al. Wearing lead aprons in surgical operating rooms: ergonomic injuries evidenced by infrared thermography. J Surg Res. 2017;209:227–233.CrossRefPubMed Alexandre D, Prieto M, Beaumont F, et al. Wearing lead aprons in surgical operating rooms: ergonomic injuries evidenced by infrared thermography. J Surg Res. 2017;209:227–233.CrossRefPubMed
33.
Zurück zum Zitat Kurihara T, Itoi T, Sofuni A, et al. Novel protective lead shield and pulse fluoroscopy can reduce radiation exposure during the ERCP procedure. Hepatogastroenterology. 2012;59:709–712.PubMed Kurihara T, Itoi T, Sofuni A, et al. Novel protective lead shield and pulse fluoroscopy can reduce radiation exposure during the ERCP procedure. Hepatogastroenterology. 2012;59:709–712.PubMed
34.
Zurück zum Zitat Muniraj T, Aslanian HR, Laine L, et al. A double-blind, randomized, sham-controlled trial of the effect of a radiation-attenuating drape on radiation exposure to endoscopy staff during ERCP. Am J Gastroenterol. 2015;110:690–696.CrossRefPubMed Muniraj T, Aslanian HR, Laine L, et al. A double-blind, randomized, sham-controlled trial of the effect of a radiation-attenuating drape on radiation exposure to endoscopy staff during ERCP. Am J Gastroenterol. 2015;110:690–696.CrossRefPubMed
35.
Zurück zum Zitat Garg MS, Patel P, Blackwood M, et al. Ocular radiation threshold projection based off of fluoroscopy time during ERCP. Am J Gastroenterol. 2017;112:716–721.CrossRefPubMed Garg MS, Patel P, Blackwood M, et al. Ocular radiation threshold projection based off of fluoroscopy time during ERCP. Am J Gastroenterol. 2017;112:716–721.CrossRefPubMed
36.
Zurück zum Zitat Bordoli SJ, Carsten CG 3rd, Cull DL, et al. Radiation safety education in vascular surgery training. J Vasc Surg. 2014;59:860–864.CrossRefPubMed Bordoli SJ, Carsten CG 3rd, Cull DL, et al. Radiation safety education in vascular surgery training. J Vasc Surg. 2014;59:860–864.CrossRefPubMed
37.
Zurück zum Zitat Morin RL, Mahesh M. Radiation exposure and patient dose in cardiology. J Am Coll Radiol. 2017;14:1581–1582.CrossRefPubMed Morin RL, Mahesh M. Radiation exposure and patient dose in cardiology. J Am Coll Radiol. 2017;14:1581–1582.CrossRefPubMed
38.
Zurück zum Zitat Pradhan AS, Lee JI, Kim JL. On the scenario of passive dosimeters in personnel monitoring: relevance to diagnostic radiology and fluoroscopy-based interventional cardiology. J Med Phys. 2016;41:81–84.CrossRefPubMedPubMedCentral Pradhan AS, Lee JI, Kim JL. On the scenario of passive dosimeters in personnel monitoring: relevance to diagnostic radiology and fluoroscopy-based interventional cardiology. J Med Phys. 2016;41:81–84.CrossRefPubMedPubMedCentral
39.
Zurück zum Zitat Liao C, Thosani N, Kothari S, et al. Radiation exposure to patients during ERCP is significantly higher with low-volume endoscopists. Gastrointest Endosc. 2015;81:e1.CrossRef Liao C, Thosani N, Kothari S, et al. Radiation exposure to patients during ERCP is significantly higher with low-volume endoscopists. Gastrointest Endosc. 2015;81:e1.CrossRef
Metadaten
Titel
Radiation Training, Radiation Protection, and Fluoroscopy Utilization Practices Among US Therapeutic Endoscopists
verfasst von
Saurabh Sethi
Monique T. Barakat
Shai Friedland
Subhas Banerjee
Publikationsdatum
25.03.2019
Verlag
Springer US
Erschienen in
Digestive Diseases and Sciences / Ausgabe 9/2019
Print ISSN: 0163-2116
Elektronische ISSN: 1573-2568
DOI
https://doi.org/10.1007/s10620-019-05564-z

Weitere Artikel der Ausgabe 9/2019

Digestive Diseases and Sciences 9/2019 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.