Radon-Domain Detection of the Nipple and the Pectoral Muscle in Mammograms

verfasst von: S. K. Kinoshita, P. M. Azevedo-Marques, R. R. Pereira Jr, J. A. H. Rodrigues, R. M. Rangayyan

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 1/2008

Einloggen, um Zugang zu erhalten

Abstract

In this paper, methods are presented for automatic detection of the nipple and the pectoral muscle edge in mammograms via image processing in the Radon domain. Radon-domain information was used for the detection of straight-line candidates with high gradient. The longest straight-line candidate was used to identify the pectoral muscle edge. The nipple was detected as the convergence point of breast tissue components, indicated by the largest response in the Radon domain. Percentages of false-positive (FP) and false-negative (FN) areas were determined by comparing the areas of the pectoral muscle regions delimited manually by a radiologist and by the proposed method applied to 540 mediolateral-oblique (MLO) mammographic images. The average FP and FN were 8.99% and 9.13%, respectively. In the detection of the nipple, an average error of 7.4 mm was obtained with reference to the nipple as identified by a radiologist on 1,080 mammographic images (540 MLO and 540 craniocaudal views).
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Belogay E, Cabrelli C, Molter U, Shonkwiler R: Calculating the Hausdorff distance between curves. Inf Process Lett 64:17–22, 1997CrossRef Belogay E, Cabrelli C, Molter U, Shonkwiler R: Calculating the Hausdorff distance between curves. Inf Process Lett 64:17–22, 1997CrossRef
2.
Zurück zum Zitat Canny J: A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell 8(6):679–698, 1986CrossRef Canny J: A computational approach to edge detection. IEEE Trans Pattern Anal Mach Intell 8(6):679–698, 1986CrossRef
3.
Zurück zum Zitat Catté F, Lons PL, Morel JM, Coll T: Image selective smoothing and edge detection by nonlinear diffusion-I. SIAM J Numer Anal 29(1):182–193, 1992CrossRef Catté F, Lons PL, Morel JM, Coll T: Image selective smoothing and edge detection by nonlinear diffusion-I. SIAM J Numer Anal 29(1):182–193, 1992CrossRef
4.
Zurück zum Zitat Catté F, Lons PL, Morel JM, Coll T: Image selective smoothing and edge detection by nonlinear diffusion-II. SIAM J Numer Anal 29(1):845–866, 1992CrossRef Catté F, Lons PL, Morel JM, Coll T: Image selective smoothing and edge detection by nonlinear diffusion-II. SIAM J Numer Anal 29(1):845–866, 1992CrossRef
5.
Zurück zum Zitat Chandrasekhar R, Attikiouzel Y: A simple method for automatically locating the nipple on mammograms. IEEE Trans Med Imag 16(5):483–494, 1997CrossRef Chandrasekhar R, Attikiouzel Y: A simple method for automatically locating the nipple on mammograms. IEEE Trans Med Imag 16(5):483–494, 1997CrossRef
6.
Zurück zum Zitat Ferrari RJ, Rangayyan RM, Desautels JEL, Borges RA, Frère AF: Analysis of asymmetry in mammograms via directional filtering with Gabor wavelets. IEEE Trans Med Imag 20(9):953–964, 2001CrossRef Ferrari RJ, Rangayyan RM, Desautels JEL, Borges RA, Frère AF: Analysis of asymmetry in mammograms via directional filtering with Gabor wavelets. IEEE Trans Med Imag 20(9):953–964, 2001CrossRef
7.
Zurück zum Zitat Ferrari RJ, Rangayyan RM, Desautels JEL, Borges RA, Frère AF: Automatic identification of pectoral muscle in mammograms. IEEE Trans Med Imag 23(2):232–245, 2004CrossRef Ferrari RJ, Rangayyan RM, Desautels JEL, Borges RA, Frère AF: Automatic identification of pectoral muscle in mammograms. IEEE Trans Med Imag 23(2):232–245, 2004CrossRef
8.
Zurück zum Zitat Gonzalez RC, Woods RE: Digital image processing. Boston, MA: Addison Wesley Pub. Co. Inc, 1993 Gonzalez RC, Woods RE: Digital image processing. Boston, MA: Addison Wesley Pub. Co. Inc, 1993
9.
Zurück zum Zitat Hou Z, Giger ML, Wolverton DE, Zhong W: Computerized analysis of mammographic parenchymal patterns for breast cancer risk assessment: feature selection. Med Phys 27(1):4–12, 2000CrossRef Hou Z, Giger ML, Wolverton DE, Zhong W: Computerized analysis of mammographic parenchymal patterns for breast cancer risk assessment: feature selection. Med Phys 27(1):4–12, 2000CrossRef
10.
Zurück zum Zitat Kapur JN, Sahoo PK, Wong AKC: A new method for grey-level picture thresholding using the entropy of the histogram. Comput Vis Graph Image Process 29:273–285, 1985CrossRef Kapur JN, Sahoo PK, Wong AKC: A new method for grey-level picture thresholding using the entropy of the histogram. Comput Vis Graph Image Process 29:273–285, 1985CrossRef
11.
Zurück zum Zitat Karssemeijer N: Automated classification of parenchymal pattern in mammograms. Phys Med Biol 43:365–378, 1998PubMedCrossRef Karssemeijer N: Automated classification of parenchymal pattern in mammograms. Phys Med Biol 43:365–378, 1998PubMedCrossRef
12.
Zurück zum Zitat Kinoshita SK, Azevedo Marques PM, Frére AF, Marana HRC, Ferrari RJ, Villela RL: Comparative analysis of shape and texture features in classification of breast masses in digitized mammograms. In: Hanson KM Ed. Medical Imaging. Proceedings of SPIE 2000; 3979, pp 872–879 Kinoshita SK, Azevedo Marques PM, Frére AF, Marana HRC, Ferrari RJ, Villela RL: Comparative analysis of shape and texture features in classification of breast masses in digitized mammograms. In: Hanson KM Ed. Medical Imaging. Proceedings of SPIE 2000; 3979, pp 872–879
13.
Zurück zum Zitat Martins ACG, Rangayyan RM: Texture element extraction via cepstral filtering in the Radon domain. IETE Journal of Research India. 48(3&4):143–150, 2002 Martins ACG, Rangayyan RM: Texture element extraction via cepstral filtering in the Radon domain. IETE Journal of Research India. 48(3&4):143–150, 2002
14.
Zurück zum Zitat Martins ACG, Rangayyan RM: Complex cepstral filtering of images and echo removal in the Radon domain. Pattern Recogn 30(11):1931–1938, 1997CrossRef Martins ACG, Rangayyan RM: Complex cepstral filtering of images and echo removal in the Radon domain. Pattern Recogn 30(11):1931–1938, 1997CrossRef
15.
Zurück zum Zitat Mendez AJ, Tahoces PG, Lado MJ, Souto M, Correa JL, Vidal JJ: Automatic detection of breast border and nipple in digital mammograms. Comput Methods Programs Biomed. 49:253–262, 1996PubMedCrossRef Mendez AJ, Tahoces PG, Lado MJ, Souto M, Correa JL, Vidal JJ: Automatic detection of breast border and nipple in digital mammograms. Comput Methods Programs Biomed. 49:253–262, 1996PubMedCrossRef
16.
Zurück zum Zitat Nishikawa RM, Giger ML, Vyborny CJ, Bick U, Doi K, Schmidt RA: Prospective computer analysis of cancer missed on screening mammography. In: Yaffe MJ Ed. Proceedings of 5th International Workshop on Digital Mammography, Toronto, Canada, 2000, pp 493–498 Nishikawa RM, Giger ML, Vyborny CJ, Bick U, Doi K, Schmidt RA: Prospective computer analysis of cancer missed on screening mammography. In: Yaffe MJ Ed. Proceedings of 5th International Workshop on Digital Mammography, Toronto, Canada, 2000, pp 493–498
17.
Zurück zum Zitat Otsu N: A threshold selection method from grey-level histogram. IEEE Trans Syst Man Cybern 8:62–66, 1978CrossRef Otsu N: A threshold selection method from grey-level histogram. IEEE Trans Syst Man Cybern 8:62–66, 1978CrossRef
18.
Zurück zum Zitat Perona P, Malik J: Scale-space and edge detection using anisotropic diffusion. IEEE Trans Pattern Anal Mach Intell 12(7):629–639, 1990CrossRef Perona P, Malik J: Scale-space and edge detection using anisotropic diffusion. IEEE Trans Pattern Anal Mach Intell 12(7):629–639, 1990CrossRef
19.
Zurück zum Zitat Rangayyan RM, Rolston WA: Directional image analysis with the Hough and Radon transforms. J Indian Inst Sci 78:3–16, 1998 Rangayyan RM, Rolston WA: Directional image analysis with the Hough and Radon transforms. J Indian Inst Sci 78:3–16, 1998
20.
Zurück zum Zitat Rangayyan RM: Biomedical Image Analysis. Boca Raton FL: CRC Press, 2005 Rangayyan RM: Biomedical Image Analysis. Boca Raton FL: CRC Press, 2005
21.
Zurück zum Zitat Reddi SS, Rudin SF, Keshavan HR: An optimal multiple threshold scheme for image segmentation. IEEE Trans Syst Man Cybern 14:661–665, 1984 Reddi SS, Rudin SF, Keshavan HR: An optimal multiple threshold scheme for image segmentation. IEEE Trans Syst Man Cybern 14:661–665, 1984
22.
Zurück zum Zitat Ridler T, Carvard S: Picture thresholding using an iterative selection method. IEEE Trans Syst Man Cybern 8:630–632, 1978 Ridler T, Carvard S: Picture thresholding using an iterative selection method. IEEE Trans Syst Man Cybern 8:630–632, 1978
23.
Zurück zum Zitat Robb RA: X-ray computed tomography: an engineering synthesis of mulitscientific principles. CRC Crit Rev Biomed Eng 7:264–333, 1982 Robb RA: X-ray computed tomography: an engineering synthesis of mulitscientific principles. CRC Crit Rev Biomed Eng 7:264–333, 1982
24.
Zurück zum Zitat Sahoo PK, Soltani S, Wong AKC, Chen YC: A survey of thresholding techniques. Comput Vis Graph Image Process 41:233–260, 1988CrossRef Sahoo PK, Soltani S, Wong AKC, Chen YC: A survey of thresholding techniques. Comput Vis Graph Image Process 41:233–260, 1988CrossRef
25.
Zurück zum Zitat Sampat MP, Whitman GJ, Markey MK, Bovik AC: Detection of spiculated lesions in mammograms. In Fitzpatrick M, Reinhardt JM Eds. Imaging Processing. Proceedings of SPIE Medical Imaging 2005. Vol. 5747, pp 26–37 Sampat MP, Whitman GJ, Markey MK, Bovik AC: Detection of spiculated lesions in mammograms. In Fitzpatrick M, Reinhardt JM Eds. Imaging Processing. Proceedings of SPIE Medical Imaging 2005. Vol. 5747, pp 26–37
26.
Zurück zum Zitat Segall CA, Acton ST: Morphological anisotropic diffusion. IEEE International Conference on Image Processing, Santa Barbara, CA, October 26–29. 3:348–351, 1997 Segall CA, Acton ST: Morphological anisotropic diffusion. IEEE International Conference on Image Processing, Santa Barbara, CA, October 26–29. 3:348–351, 1997
27.
Zurück zum Zitat Srinivasa N, Ramakrishnan KR, Rajgopal K: Detection of edges from projections. IEEE Trans Med Imag 11(1):76–80, 1992CrossRef Srinivasa N, Ramakrishnan KR, Rajgopal K: Detection of edges from projections. IEEE Trans Med Imag 11(1):76–80, 1992CrossRef
28.
Zurück zum Zitat Tsai W: Moment-preserving thresholding: a new approach. Comput Vis Graph Image Process 29:377–393, 1985CrossRef Tsai W: Moment-preserving thresholding: a new approach. Comput Vis Graph Image Process 29:377–393, 1985CrossRef
29.
Zurück zum Zitat Zhou C, Chan H-P, Petrick N, Helvie MA, Goodsitt MM, Sahiner B, Hadjiski LM: Computerized image analysis: estimation of breast density on mammograms. Med Phys 28(6):1056–1069, 2001PubMed Zhou C, Chan H-P, Petrick N, Helvie MA, Goodsitt MM, Sahiner B, Hadjiski LM: Computerized image analysis: estimation of breast density on mammograms. Med Phys 28(6):1056–1069, 2001PubMed
30.
Zurück zum Zitat Yin FF, Giger ML, Doi K, Vyborny CJ, Schmidt RA: Computerized detection of masses in digital mammograms: analysis of bilateral subtraction images. Med Phys 18(5):955–963, 1994CrossRef Yin FF, Giger ML, Doi K, Vyborny CJ, Schmidt RA: Computerized detection of masses in digital mammograms: analysis of bilateral subtraction images. Med Phys 18(5):955–963, 1994CrossRef
Metadaten
Titel
Radon-Domain Detection of the Nipple and the Pectoral Muscle in Mammograms
verfasst von
S. K. Kinoshita
P. M. Azevedo-Marques
R. R. Pereira Jr
J. A. H. Rodrigues
R. M. Rangayyan
Publikationsdatum
01.03.2008
Verlag
Springer-Verlag
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 1/2008
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-007-9035-6

Weitere Artikel der Ausgabe 1/2008

Journal of Digital Imaging 1/2008 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.