Balloon mitral valvotomy (BMV) is a safe and effective therapy for rheumatic mitral stenosis. During the procedure, the coiled portion of 0.025 in. stainless steel BMV guidewire broke off within the giant left atrium (LA). Attempts to retrieve the guidewire with various snares failed as it was moving freely within the voluminous LA. We describe a technique wherein the broken guidewire was retrieved with a snare made of 0.014 in. percutaneous transluminal coronary angioplasty guidewire. The mechanism and prevention of this complication and management options are discussed.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Palacios I, Block PC, Brandi S, Blanco P, Casal H, Pulido JI, Munoz S, D’Empaire G, Ortega MA, Jacobs M, et al. Percutaneous balloon valvotomy for patients with severe mitral stenosis. Circulation. 1987;75(4):778–84.PubMed Palacios I, Block PC, Brandi S, Blanco P, Casal H, Pulido JI, Munoz S, D’Empaire G, Ortega MA, Jacobs M, et al. Percutaneous balloon valvotomy for patients with severe mitral stenosis. Circulation. 1987;75(4):778–84.PubMed
2.
Zurück zum Zitat Manjunath CN, Srinivasa KH, Patil CB, Venkatesh HV, Bhoopal TS, Dhanalakshmi C. Balloon mitral valvuloplasty: our experience with a modified technique of crossing the mitral valve in difficult cases. Cathet Cardiovasc Diagn. 1998;44(1):23–6.CrossRefPubMed Manjunath CN, Srinivasa KH, Patil CB, Venkatesh HV, Bhoopal TS, Dhanalakshmi C. Balloon mitral valvuloplasty: our experience with a modified technique of crossing the mitral valve in difficult cases. Cathet Cardiovasc Diagn. 1998;44(1):23–6.CrossRefPubMed
3.
Zurück zum Zitat Complications and mortality of percutaneous balloon mitral commissurotomy. A report from the National Heart, Lung, and Blood Institute Balloon Valvuloplasty Registry. Circulation. 1992;85(6):2014–24. Complications and mortality of percutaneous balloon mitral commissurotomy. A report from the National Heart, Lung, and Blood Institute Balloon Valvuloplasty Registry. Circulation. 1992;85(6):2014–24.
4.
Zurück zum Zitat Inoue K, Owaki T, Nakamura T, Kitamura F, Miyamoto N. Clinical application of transvenous mitral commissurotomy by a new balloon catheter. J Thorac Cardiovasc Surg. 1984;87:394–402.PubMed Inoue K, Owaki T, Nakamura T, Kitamura F, Miyamoto N. Clinical application of transvenous mitral commissurotomy by a new balloon catheter. J Thorac Cardiovasc Surg. 1984;87:394–402.PubMed
5.
Zurück zum Zitat Thomas J, Sinclair-Smith B, Bloomfield D, Davachi A. Non-surgical retrieval of a broken segment of steel spring guide from the right atrium and the inferior vena cava. Circulation. 1964;30:106–8.PubMed Thomas J, Sinclair-Smith B, Bloomfield D, Davachi A. Non-surgical retrieval of a broken segment of steel spring guide from the right atrium and the inferior vena cava. Circulation. 1964;30:106–8.PubMed
6.
Zurück zum Zitat Koseoglu K, Parildar M, Oran I, Memis A. Retrieval of intravascular foreign bodies with goose neck snare. Eur J Radiol. 2004;49(3):281–5.CrossRefPubMed Koseoglu K, Parildar M, Oran I, Memis A. Retrieval of intravascular foreign bodies with goose neck snare. Eur J Radiol. 2004;49(3):281–5.CrossRefPubMed
7.
Zurück zum Zitat Massumi RA, Ross AM. A traumatic nonsurgical technique for removal of broken catheters from cardiac cavities. N Engl J Med. 1967;277(4):195–6.CrossRefPubMed Massumi RA, Ross AM. A traumatic nonsurgical technique for removal of broken catheters from cardiac cavities. N Engl J Med. 1967;277(4):195–6.CrossRefPubMed
8.
Zurück zum Zitat Rossi P. “Hook catheter”, technique for transfemoral removal of foreign body from the right side of the heart. Am J Roentgenol Radium Ther Nucl Med. 1970;109(01):101–6.PubMed Rossi P. “Hook catheter”, technique for transfemoral removal of foreign body from the right side of the heart. Am J Roentgenol Radium Ther Nucl Med. 1970;109(01):101–6.PubMed
9.
Zurück zum Zitat Grabenwoeger F, Dock W, Pinterits F, Apple W. Fixed intravascular foreign bodies: a new method for removal. Radiology. 1988;167(2):555–6.PubMed Grabenwoeger F, Dock W, Pinterits F, Apple W. Fixed intravascular foreign bodies: a new method for removal. Radiology. 1988;167(2):555–6.PubMed
10.
Zurück zum Zitat Martins EC, Faria GB. Percutaneous retrieval of intracardiac foreign body with a novel technique. Arq Bras Cardiol. 2007;88(6):e179–81.CrossRefPubMed Martins EC, Faria GB. Percutaneous retrieval of intracardiac foreign body with a novel technique. Arq Bras Cardiol. 2007;88(6):e179–81.CrossRefPubMed
11.
Zurück zum Zitat Massin M, Lombet J, Rigo J. Percutaneous retrieval of broken silastic catheter from the left atrium in a critically Ill premature infant. Cathet Cardiovasc Diagn. 1997;42(4):409–11.CrossRefPubMed Massin M, Lombet J, Rigo J. Percutaneous retrieval of broken silastic catheter from the left atrium in a critically Ill premature infant. Cathet Cardiovasc Diagn. 1997;42(4):409–11.CrossRefPubMed
12.
Zurück zum Zitat Ruiz CE, Nystrom GA, Butt AI, Zhang HP. Percutaneous retrieval of a broken umbilical catheter from left atrium in a premature newborn. Cathet Cardiovasc Diagn. 1995;36(3):265–8.CrossRefPubMed Ruiz CE, Nystrom GA, Butt AI, Zhang HP. Percutaneous retrieval of a broken umbilical catheter from left atrium in a premature newborn. Cathet Cardiovasc Diagn. 1995;36(3):265–8.CrossRefPubMed
13.
Zurück zum Zitat Casserly IP, Goldstein JA, Rogers JH, Lasala JM. Paradoxical embolization of a fractured guidewire: successful retrieval from left atrium using a snare device. Catheter Cardiovasc Interv. 2002;57(1):34–8.CrossRefPubMed Casserly IP, Goldstein JA, Rogers JH, Lasala JM. Paradoxical embolization of a fractured guidewire: successful retrieval from left atrium using a snare device. Catheter Cardiovasc Interv. 2002;57(1):34–8.CrossRefPubMed
14.
Zurück zum Zitat Ramondo AB, Favero L, Chioin R. Percutaneous retrieval of a broken catheter from the left atrium in an adult. J Interv Cardiol. 2002;15(5):417–9.CrossRefPubMed Ramondo AB, Favero L, Chioin R. Percutaneous retrieval of a broken catheter from the left atrium in an adult. J Interv Cardiol. 2002;15(5):417–9.CrossRefPubMed
Metadaten
Titel
Removal of broken balloon mitral valvotomy coiled guidewire from giant left atrium using indigenous snare
verfasst von
Ravindranath Khandenahally Shankarappa
Arunkumar Panneerselvam
Ramesh Dwarakaprasad
Mohan Honnayya Nayak
Manjunath Cholenahally Nanjappa
Publikationsdatum
01.01.2011
Verlag
Springer Japan
Erschienen in
Cardiovascular Intervention and Therapeutics / Ausgabe 1/2011
Print ISSN: 1868-4300
Elektronische ISSN: 1868-4297
DOI
https://doi.org/10.1007/s12928-010-0025-0

Weitere Artikel der Ausgabe 1/2011

Cardiovascular Intervention and Therapeutics 1/2011 Zur Ausgabe

Nach Herzinfarkt mit Typ-1-Diabetes schlechtere Karten als mit Typ 2?

29.05.2024 Herzinfarkt Nachrichten

Bei Menschen mit Typ-2-Diabetes sind die Chancen, einen Myokardinfarkt zu überleben, in den letzten 15 Jahren deutlich gestiegen – nicht jedoch bei Betroffenen mit Typ 1.

Erhöhtes Risiko fürs Herz unter Checkpointhemmer-Therapie

28.05.2024 Nebenwirkungen der Krebstherapie Nachrichten

Kardiotoxische Nebenwirkungen einer Therapie mit Immuncheckpointhemmern mögen selten sein – wenn sie aber auftreten, wird es für Patienten oft lebensgefährlich. Voruntersuchung und Monitoring sind daher obligat.

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.