Skip to main content
Erschienen in: Head & Face Medicine 1/2023

Open Access 01.12.2023 | Research

Results of thermal osteonecrosis for implant removal on electron microscopy, implant stability, and radiographic parameters – a rat study

verfasst von: Kristian Kniha, Eva Miriam Buhl, Faruk Al-Sibai, Stephan Christian Möhlhenrich, Anna Bock, Marius Heitzer, Frank Hölzle, Ali Modabber

Erschienen in: Head & Face Medicine | Ausgabe 1/2023

Abstract

Background

This rat study aimed to evaluate the feasibility of temperature thresholds that affect peri-implant bone cells and morphology and the potential usefulness of thermal necrosis for inducing implant removal for a subsequent in vivo pig study.

Methods

On one side, rat tibiae were thermally treated before implant insertion. The contralateral side was used as the control group without tempering. Temperatures of 4 °C, 3 °C, 2 °C, 48 °C, 49 °C, and 50 °C were evaluated with a tempering time of 1 min. Energy-dispersive X-ray spectroscopy (EDX) and transmission electron microscopy (TEM) analyses were performed.

Results

The EDX analysis revealed significant increases in element weights at 50 °C (e.g., calcium, phosphate, sodium, and sulfur; p < 0.01). The results of the TEM analysis showed that at all the applied cold and warm temperatures, signs of cell damage were observed, including vacuolization, shrinkage, and detachment from the surrounding bone matrix. Some cells became necrotic, leaving the lacunae empty.

Conclusions

Temperature of 50 °C led to irreversible cell death. The degree of damage was more significant at 50 °C and 2 °C than at 48 °C and 5 °C. Although this was a preliminary study, from the results, we identified that a temperature of 50 °C at a time interval of 60 min can lower the number of samples in a further study of thermo-explantation. Thus, the subsequent planned in vivo study in pigs, which will consider osseointegrated implants, is feasible.
Hinweise

Supplementary Information

The online version contains supplementary material available at https://​doi.​org/​10.​1186/​s13005-023-00349-2.

Publisher’ s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Introduction

In the current literature, only few data support the use of a controlled thermoexplantation procedure for implant removal. No clear indications have been established on the exact temperature and time interval that would produce sufficient but minimal osteonecrosis around implants to remove them without trauma. Uncontrolled temperatures could easily lead to extensive jaw necrosis and would be more likely to cause severe inflammation rather than atraumatic explantation. Consequently, a precise temperature within the initial developmental range of bone necrosis must be selected for successful thermal explantation. Nevertheless, several publications have demonstrated the efficient loosening of osseointegrated implants using warm temperatures with, for example, ultra-high-frequency and laser surgical devices [13]. The heat input was uncontrolled and inconsistent in all the reported cases.
A recent systemic review analyzed the literature regarding the threshold values for thermal bone necrosis [4]. The authors concluded that no studies have indicated a specific threshold value for bone necrosis. For a tempering time of 1 min, the values ranged from 47 °C to 55 °C, but no threshold value has yet been established for cryoinsult. Thus, in the current literature, no clear evidence exists that support the use of a managed thermo-explantation technique or suggest the exact temperature and time interval around the implants that would generate adequate but minimal osteonecrosis to extract them without trauma. Dental implants that replace failed implants have lower survival rates. However, if they osseointegrate successfully, the method described here can be considered [5]. High temperatures could easily lead to substantial jaw necrosis and cause severe inflammation. Therefore, more in-depth and pre-clinical studies are needed to gain further insights to evaluate the potential usefulness of thermal necrosis for implant removal before it can be predictably applied to patients. In our preliminary cadaver study, temperatures of 51 °C and 5 °C at time intervals of 10 and 30 s were identified, respectively, which led to significant osseous matrix degeneration [6]. In addition, transmission electron microscopy (TEM) at 53 °C revealed a decalcification and swollen mitochondria, which lost the structure of their inner cristae.
The present rat study was conducted to verify these results in an in vivo setting and reduce the sample size for subsequent in vivo studies in the pig with osseointegrated implants. The primary aim of this study was to analyze feasible cold and warm temperatures and time intervals. For this purpose, mineralization of the peri-implant bone of the rat tibia was analyzed on energy-dispersive X-ray spectroscopy (EDX), and osteocyte morphology was analyzed for signs of injury on TEM. We hypothesized that an appropriate temperature and time interval for warm and cold temperatures would induce minimal peri-implant osteonecrosis. Furthermore, implant stability and bone loss over time were measured.

Methods

Experimental protocol

This study included 48 adult male Sprague–Dawley rats, each weighing 450 g and aged 4 months (Janvier Labs, Le Genest-Saint-Isle, France). One examiner completed all the steps of the study experiment. This investigation was conducted in accordance with the guidelines of the European Parliament and the council on the protection of animals used for scientific purposes, ARRIVE (Animal Research: Reporting of In Vivo Experiments) [7], and Directive 2010/63/EU. The study protocol received ethical approval and consent to participate from the appropriate local authority (Landesamt für Natur und Verbraucherschutz, Recklinghausen, Germany; Ref. 2019A276).
For a tempering time of 1 min, the six test groups were divided into cold and warm temperatures of 4 °C, 3 °C, 2 °C, 48 °C, 49 °C, and 50 °C. These temperatures were chosen based on the findings of a prior investigation [8]. In each group, six temperatures were randomly tested in eight animals. Each animal received one implant in each tibia (Modus 2.0 3-mm cortical screws, Medartis AG, Basel, Switzerland). Therefore, for each temperature, eight test und eight control samples were investigated, resulting in 12 groups with 96 implants. All the procedures were performed under general anesthesia. At 30 min before the start of surgery, the animals were weighed. Then, the animals received 0.03-mg buprenorphine subcutaneously (0.1-ml Temgesic/kg of body weight, Remedix GmbH, Germany). Anesthesia was induced with an inhalation narcotic in an induction box with isoflurane (4 vol.%) and oxygen (vol. 30%) air mixture (Isofluran, Piramal GmbH, Hallbergmoos, Germany). Inhalation narcosis with an isoflurane (2 vol.%) and oxygen (30%) air mixture was continued via a nasal mask. After the induction of anesthesia, the animals were positioned on an adjustable warming mat.
Before implant insertion, one tibia was randomly chosen as the test side in each animal. Without tempering, the contralateral side was used as the control group. Before temperature application and implantation, the skin was shaved, disinfected, and cut with a scalpel after sterile draping. Implantation was performed after exposure of the tibia by predrilling with a pilot drill of 1.5-mm diameter under strict cooling with sterile saline (Medartis AG, Basel, Switzerland). In the case of the test group, the thermal treatment was administered after predrilling and before implant placement. The device exhibited a congruent clamp fit in the drill studs. A screw was inserted in accordance with the manufacturer's protocol by using a screwdriver and a torque of 15–20 Ncm. After primary stable insertion of the implants, resonance frequency analysis with hand-screwed individual smart pegs (Osstell, Gothenburg, Sweden) was performed to measure the primary stability after implant insertion (Fig. 1). Primary stability was measured with the implant stability quotient (ISQ) in four directions (i.e., from left to right and from front to back [9]), resulting in a calculated mean ISQ value. The wounds were closed with suture material. By using a standardized 90° dental X-ray computed tomography device (Dentsply Detrey, Germany, Konstanz), the distance between the alveolar crest at the implant and the implant shoulder was measured directly after surgery on both implant sides [10]. The measurements were taken between the implant shoulder and the greatest coronal level of the direct bone-to-implant contact (Fig. 2). All the measurements were performed using specialized computer software (ImageJ Version 1.51, National Institutes of Health, USA) [11]. Every day postoperatively, the animals were treated once with carprofen 4 mg/kg subcutaneously (Rimadyl, Zoetis GmbH, Berlin, Germany) for analgesia. At the second follow-up, 7 days after surgery, ISQ evaluation and radiographic imaging were repeated.
The EDX and TEM analyses included six drill samples, one for each of the following temperatures: 4 °C, 3 °C, 2 °C, 48 °C, 49 °C, and 50 °C. The EDX analysis was performed using a scanning electron microscope (SEM; ESEM XL 30 FEG; FEI, Eindhoven, the Netherlands) equipped with an EDX detector system (EDAX, Mahwah, NJ) in the backscatter mode, with an acceleration voltage of 15 kV. The samples for the SEM and EDX analyses were fixed in 3% glutaraldehyde in 0.1 M Sorensen’s phosphate buffer, dehydrated in an ascending ethanol series (30%–100%), and dried at 37 °C, in accordance with the procedure used in a previously published study [6]. The EDX analysis was performed with an EDAX Genesis system (EDAX), at eight measurement points using a mean value for each sample.
For TEM, the samples were fixed in 3% glutaraldehyde in 0.1 M Sorensen’s phosphate buffer and decalcified in 0.5 M EDTA. After post-fixation in 1% OsO4 (Roth, Karlsruhe, Germany) in a 25 mM sucrose buffer, the samples were dehydrated in an ascending ethanol series, incubated in propylene oxide (Serva, Heidelberg, Germany) and embedded in Epon resin (Serva). Ultrathin Sects. (70–100 nm) were cut and stained with 0.5% uranyl acetate and 1% lead citrate (both EMS, Munich, Germany) for contrast enhancement. The samples were viewed at an acceleration voltage of 60 kV by using a Zeiss Leo 906 TEM service (Carl Zeiss, Oberkochen, Germany).

Statistical analyses

Analyses were performed using the Prism 8 software for Mac OS X (GraphPad, La Jolla, CA) running on Apple OS X. The variables were analyzed using the Kolmogorov–Smirnov normality test. The Kruskal–Wallis and Dunn’s multiple comparison tests with adjustment were used to identify differences between the parameters.
Post hoc power analysis was performed with the G*Power software (Heinrich-Heine-Universität, Düsseldorf, Germany) using the post hoc analysis of variance with groups to determine a power of 100% (parameter primary study aim EDX) based on the total sample size of 30 and six groups using an effect size of 11.23 and an α of 0.05.

Results

For the EDX analysis, one sample for each of the six temperature/time intervals was used in the evaluation (Table 1). A significant increase in bone calcium content was observed in the warm temperature groups (48 °C–50 °C, p < 0.01), which increased when the cold temperatures were reduced but without any significant difference within the group. By contrast, the carbon content decreased parallel to the increase in calcium content. The calcium-to-carbon ratio was used to normalize the calcium content to the organic component and therefore reflected the degree of bone calcification, which increased with increasing temperatures. Moreover, the sodium content increased significantly with the temperature stimulus but without significant differences between the cold and warm groups. Like the calcium content, the phosphate value analogously reflected increases in the values with increasing damaging temperature stimulus (3 °C–50 °C, p = 0.01 and 48 °C–50 °C, p< 0.01). The calcium-to-phosphate ratio increased with decreasing cold and increasing warm temperatures. The sulfur content decreased when the temperature was decreased from 4 °C to 2 °C and from 48 °C to 50 °C [12]. TEM revealed that at all the applied cold and warm temperatures, the osteocytes in the lacunae of the bone within the treatment area showed signs of cell damage, including vacuolization, shrinkage, and detachment from the surrounding bone matrix. Some cells became necrotic, leaving empty lacunae behind (Fig. 3). The TEM images of osteocytes showed that both heat and cold treatments induced cellular damage. The damage at hot temperatures (48 °C, 49 °C, and 50 °C) was greater than that at cold temperatures (2 °C, 3 °C, and 4 °C). At warm temperatures, the cell injury worsened with the increase in temperature applied such that 50 °C led to irreversible cell death. The degree of damage was greater at 50 °C and 2 °C than at 48 °C and 5 °C.
Table 1
Descriptive and statistical values for EDX analysis of bone composition between the groups
  
4 °C
3 °C
2 °C
48 °C
49 °C
50 °C
p Value
Weight %
Element
Mean
SD
Mean
SD
Mean
SD
Mean
SD
Mean
SD
Mean
SD
 
 
Calcium
2.27
2.33
4.63
6.20
29.33
35.71
0.55
0.22
13.63
10.08
25.31
4.78
2°–48° p < 0.01
3°–50° p = 0.01
              
4°–50° p < 0.01
48°–50° p < 0.01
48°–49° p < 0.01
 
Carbon
86.34
4.12
85.83
7.29
57.56
34.48
89.90
2.44
74.05
13.06
48.70
6.89
4°–49° p = 0.04
4°–50° p < 0.01
3°–49° p = 0.04
3°–50° p < 0.01
 
Oxygen
7.45
3.01
5.96
2.93
5.22
4.07
8.01
2.54
4.25
1.86
12.63
5.46
2°–50° p = 0.04
49°–50° p < 0.01
 
Sodium
0.32
0.15
0.30
0.11
0.64
0.55
0.33
0.07
0.48
0.19
0.69
0.25
3°–50° p = 0.01
 
Phosphate
2.09
2.82
2.33
2.76
6.51
5.79
0.43
0.34
7.09
4.18
12.40
1.98
2°–48° p = 0.01
3°–50° p = 0.01
4°–50° p < 0.01
48°–50° p < 0.01
48°–49° p < 0.01
 
Sulphur
1.52
1.77
0.94
0.46
0.74
0.85
0.79
0.26
0.50
0.37
0.27
0.17
3°–50° p < 0.01
4°–50° p = 0.02
2°–48° p < 0.01
Ratios
Ca/C
0.03
 
0.05
 
0.32
 
0.01
 
0.18
 
0.5
  
 
Ca/P
1.09
 
1.98
 
3.14
 
1.27
 
1.92
 
2.04
  
The measurement of peri-implant bone loss showed an increase in the distance from the bone attachment at the implant to the shoulder with increasing temperature stimulus. However, these differences were insignificant (p > 0.05; Fig. 4A).
The mean ISQ values reflect the same stability values for the implant placement and the control group after 7 days. An inhomogeneous result was evaluated in the test groups, as the ISQ values at 4 °C–3 °C decreased and those at 3 °C–2 °C increased again (p < 0.05). On the other hand, decreasing stability values were observed at temperatures of 48 °C–50 °C, but the differences were not statistically significant (Fig. 4B).

Discussion

The impact of targeted heating or cooling was evaluated in this rat study to obtain evidence of the behavior of peri-implant bone necrosis for inducing implant removal. Eriksson and Albrektsson investigated the effects of heat on bone metabolism and published their data. They reported that arterial and venous hyperemia could be observed at short high-temperature surges, with a partial halt (hemostasis) of blood flow in numerous capillaries [13]. However, after 3 weeks, bone resorption was observed [13].
Mineral bone composition can indicate bone damage. Decreased Ca/P ratio is associated with induced bone loss [14], whereas the Ca/C ratio indicates the degree of calcification of the bone matrix at different stages in the respective measure [15]. These study results showed that both the Ca/P and Ca/C ratios increased with the worsening of the temperature-induced bone damage. In the damaged bone matrix, the Ca/C ratio also increased [15]. The warm temperature groups showed a substantial increase in bone calcium content, which also increased when the cold temperatures were reduced, but no significant within-group difference was found. In our study, the carbon content reflected the organic compound of the bone and decreased parallel to the increase in calcium content. Sulfur content, which is also correlated to bone physiology, decreased when the temperature decreased from 4 °C to 2 °C and from 48 °C to 50 °C [12].
The TEM images in another study showed that a temperature input of 53 °C resulted in decalcification and enlarged mitochondria, which lost their inner cristae structure [8]. In our investigation, warm temperatures also led to cell injury and irreversible cell death at 50 °C. Furthermore, the first-choice imaging modality should always be conventional radiography, as it provides an overview of the architecture and pathological states of the bone and soft tissues of the region of interest [16]. The distance between the implant shoulder and the bone contact with the implant was measured in this study to gather data on the behavior of the peri-implant bone level around zirconia implants [10]. Higher temperatures [17] led to not only loss of bone contact but also increases in the sizes of the infrabony pockets next to the treated implant. An increased distance over time may indicate bone loss and implant loosening. However, this study showed no significant differences over the 7-day follow-up period. In another study, the peri-implant pockets were significantly larger than those in the control group at 50 °C for 1 min [17]. A more extended follow-up for this parameter seems advisable for future study protocols. Furthermore, CT or magnetic resonance imaging might be more sensitive, as the sensitivity of plain film for detecting early stages of bone necrosis is rather low at 41% [18].
Oscillations occurring as reactions to the implant-to-bone contact can indicate the bone-to-implant contact interface from the resonance frequency analysis (RFA). The ISQ is the unit of measurement for RFA [19]. In humans with real implant geometries, the values range from 1 to 100, with a high ISQ score (> 60) indicating good stability [9]. In this study, the ISQ system was tested on miniature implants, as a suitable thread could be cut on the mini-screws. The aim was to determine whether such implant loosening can be detected in small animal models as well. As a critical reflection, we can infer that the ISQ model was established for real implants in humans. Therefore, we can assume that the stability values are fundamentally lower than those in humans owing to the smaller size. This was also shown in our evaluation and should be considered when interpreting our data. An inhomogeneous result was evaluated in the test groups; nevertheless, at temperatures ranging from 48 °C to 50 °C, decreasing stability values were found, but the differences were not significant. In the following pig study with real implants, based on these findings, the ISQ value measurement could be used to detect implant loosening.
Furthermore, the implants used in this study were not osseointegrated bodies. As a result, identifying valid threshold temperature values for osseointegrated implants necessitates in vivo research. With regard to implant survival there are no adverse results in diabetes type I patients [20]. However, in terms of possible complications, more postoperative bleeding and wound infections have been described. Regarding thermo-explantation, increased bleeding may affect the temperature level. As a successful thermo-explantation can only be confirmed in osseointegrated implants, this rat study was conducted to minimize the sample sizes in later animal studies using pigs with osseointegrated implants. As soon as the temperature time interval can be narrowed down, further studies will analyze the effect of different implant designs and shoulder formations on the described method [21]. If a special device can be developed, then for the current occasion a sufficient reduction of air contamination should also be considered [22].

Conclusion

The cell damage at hot temperatures (48 °C, 49 °C, and 50 °C) was greater than that at cold temperatures (2 °C, 3 °C, and 4 °C). Although this was a preliminary study, the temperatures and intervals identified in areas of both heat and cold could help lower the number of samples in further studies of thermo-explantation. At a temperature of 50 °C at a time interval of 60 s, significant bone composition changes were observed. This level may be used for future thermo-explantation. The subsequent planned in vivo pig study, which will consider osseointegrated implants, is feasible.

Acknowledgements

The authors thank Nicole Bataille for the excellent technical assistance. This research was funded by the German Federal Ministry for Economic Affairs and Energy (BMWi) within the Promotion of Joint Industrial Research Program (IGF) pursuant to the decision of the German Bundestag. It was part of the research project 20302N by the Association for Research and Precision Mechanics, Optics and Medical Technology (FOM), under the auspices of the German Federation of Industrial Research Associations (AIF). The authors report no conflict of interest.

Compliance with ethical standards

The study protocol received ethical approval from the appropriate local authority (Landesamt für Natur und Verbraucherschutz, Recklinghausen, Germany; Ref. 2019A276).

Declarations

The study protocol received Ethical Approval and Consent to participate from the appropriate local authority (Landesamt für Natur und Verbraucherschutz, Recklinghausen, Germany; Ref. 2019A276).
For this type of study (animal study), formal consent is not required.

Competing interests

The authors declare that they have no competing interests and that they approved the publication.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’ s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Anhänge
Literatur
1.
Zurück zum Zitat Worni A, Marchand L, Sailer I, Cornish D, Hicklin SP. Explantation of an Osseointegrated Titanium Implant Using Laser-Induced Thermo-necrosis: A Case Report. Int J Oral Maxillofac Implants. 2018;33(6):e151–5.CrossRefPubMed Worni A, Marchand L, Sailer I, Cornish D, Hicklin SP. Explantation of an Osseointegrated Titanium Implant Using Laser-Induced Thermo-necrosis: A Case Report. Int J Oral Maxillofac Implants. 2018;33(6):e151–5.CrossRefPubMed
2.
Zurück zum Zitat Massei G, Szmukler-Moncler S. Thermo-explantation. a novel approach to remove osseointegrated implants. Eur Cells and Materials. 2004;7(Suppl 2):48 (ISSN 1473-2262). Massei G, Szmukler-Moncler S. Thermo-explantation. a novel approach to remove osseointegrated implants. Eur Cells and Materials. 2004;7(Suppl 2):48 (ISSN 1473-2262).
3.
Zurück zum Zitat Cunliffe J, Barclay C. Removal of a dental implant: An unusual case report. Journal of Dental Implants. 2011;1(1):22–5.CrossRef Cunliffe J, Barclay C. Removal of a dental implant: An unusual case report. Journal of Dental Implants. 2011;1(1):22–5.CrossRef
4.
Zurück zum Zitat Kniha K, Heussen N, Weber E, Möhlhenrich SC, Hölzle F, Modabber A. Temperature Threshold Values of Bone Necrosis for Thermo-Explantation of Dental Implants-A Systematic Review on Preclinical In Vivo Research. Materials (Basel). 2020;13(16):3461. https://doi.org/10.3390/ma13163461. Kniha K, Heussen N, Weber E, Möhlhenrich SC, Hölzle F, Modabber A. Temperature Threshold Values of Bone Necrosis for Thermo-Explantation of Dental Implants-A Systematic Review on Preclinical In Vivo Research. Materials (Basel). 2020;13(16):3461. https://​doi.​org/​10.​3390/​ma13163461.
5.
Zurück zum Zitat Chrcanovic BR, Kisch J, Albrektsson T, Wennerberg A. Survival of dental implants placed in sites of previously failed implants. Clin Oral Implant Res. 2017;28(11):1348–53.CrossRef Chrcanovic BR, Kisch J, Albrektsson T, Wennerberg A. Survival of dental implants placed in sites of previously failed implants. Clin Oral Implant Res. 2017;28(11):1348–53.CrossRef
7.
Zurück zum Zitat Percie du Sert N, Hurst V, Ahluwalia A, et al. The ARRIVE guidelines 2.0: Updated guidelines for reporting animal research. PLOS Biology. 2020;18(7):e3000410.CrossRefPubMedPubMedCentral Percie du Sert N, Hurst V, Ahluwalia A, et al. The ARRIVE guidelines 2.0: Updated guidelines for reporting animal research. PLOS Biology. 2020;18(7):e3000410.CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Kniha K, Buhl EM, Hermanns-Sachweh B, et al. Implant removal using thermal necrosis-an in vitro pilot study. Clin Oral Investig. 2021;25(1):265–73.CrossRefPubMed Kniha K, Buhl EM, Hermanns-Sachweh B, et al. Implant removal using thermal necrosis-an in vitro pilot study. Clin Oral Investig. 2021;25(1):265–73.CrossRefPubMed
9.
Zurück zum Zitat Ibrahim A, Heitzer M, Bock A, et al. Relationship between Implant Geometry and Primary Stability in Different Bony Defects and Variant Bone Densities: An In Vitro Study. Materials (Basel). 2020;13(19):4349. https://doi.org/10.3390/ma13194349. Ibrahim A, Heitzer M, Bock A, et al. Relationship between Implant Geometry and Primary Stability in Different Bony Defects and Variant Bone Densities: An In Vitro Study. Materials (Basel). 2020;13(19):4349. https://​doi.​org/​10.​3390/​ma13194349.
10.
Zurück zum Zitat Kniha K, Gahlert M, Hicklin S, Bragger U, Kniha H, Milz S. Evaluation of Hard and Soft Tissue Dimensions Around Zirconium Oxide Implant-Supported Crowns: A 1-Year Retrospective Study. J Periodontol. 2016;87(5):511–8.CrossRefPubMed Kniha K, Gahlert M, Hicklin S, Bragger U, Kniha H, Milz S. Evaluation of Hard and Soft Tissue Dimensions Around Zirconium Oxide Implant-Supported Crowns: A 1-Year Retrospective Study. J Periodontol. 2016;87(5):511–8.CrossRefPubMed
11.
Zurück zum Zitat Schindelin J, Arganda-Carreras I, Frise E, et al. Fiji: an open-source platform for biological-image analysis. Nat Methods. 2012;9(7):676–82.CrossRefPubMed Schindelin J, Arganda-Carreras I, Frise E, et al. Fiji: an open-source platform for biological-image analysis. Nat Methods. 2012;9(7):676–82.CrossRefPubMed
12.
Zurück zum Zitat Gambari L, Grigolo B, Grassi F. Hydrogen Sulfide in Bone Tissue Regeneration and Repair: State of the Art and New Perspectives. Int J Mol Sci. 2019;20(20):5231.CrossRefPubMedPubMedCentral Gambari L, Grigolo B, Grassi F. Hydrogen Sulfide in Bone Tissue Regeneration and Repair: State of the Art and New Perspectives. Int J Mol Sci. 2019;20(20):5231.CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Eriksson AR, Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit. J Prosthet Dent. 1983;50(1):101–7.CrossRefPubMed Eriksson AR, Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit. J Prosthet Dent. 1983;50(1):101–7.CrossRefPubMed
14.
Zurück zum Zitat Kourkoumelis N, Balatsoukas I, Tzaphlidou M. Ca/P concentration ratio at different sites of normal and osteoporotic rabbit bones evaluated by Auger and energy dispersive X-ray spectroscopy. J Biol Phys. 2012;38(2):279–91.CrossRefPubMed Kourkoumelis N, Balatsoukas I, Tzaphlidou M. Ca/P concentration ratio at different sites of normal and osteoporotic rabbit bones evaluated by Auger and energy dispersive X-ray spectroscopy. J Biol Phys. 2012;38(2):279–91.CrossRefPubMed
15.
Zurück zum Zitat Okata H, Nakamura M, Henmi A, et al. Calcification during bone healing in a standardised rat calvarial defect assessed by micro-CT and SEM-EDX. Oral Dis. 2015;21(1):74–82.CrossRefPubMed Okata H, Nakamura M, Henmi A, et al. Calcification during bone healing in a standardised rat calvarial defect assessed by micro-CT and SEM-EDX. Oral Dis. 2015;21(1):74–82.CrossRefPubMed
16.
Zurück zum Zitat Pineda C, Espinosa R, Pena A. Radiographic imaging in osteomyelitis: the role of plain radiography, computed tomography, ultrasonography, magnetic resonance imaging, and scintigraphy. Semin Plast Surg. 2009;23(2):80–9.CrossRefPubMedPubMedCentral Pineda C, Espinosa R, Pena A. Radiographic imaging in osteomyelitis: the role of plain radiography, computed tomography, ultrasonography, magnetic resonance imaging, and scintigraphy. Semin Plast Surg. 2009;23(2):80–9.CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Trisi P, Berardini M, Falco A, Vulpiani MP, Masciotra L. Effect of 50 to 60 degrees C heating on osseointegration of dental implants in dense bone: an in vivo histological study. Implant Dent. 2014;23(5):516–21.CrossRefPubMed Trisi P, Berardini M, Falco A, Vulpiani MP, Masciotra L. Effect of 50 to 60 degrees C heating on osseointegration of dental implants in dense bone: an in vivo histological study. Implant Dent. 2014;23(5):516–21.CrossRefPubMed
18.
Zurück zum Zitat Stoica Z, Dumitrescu D, Popescu M, Gheonea I, Gabor M, Bogdan N. Imaging of avascular necrosis of femoral head: familiar methods and newer trends. Curr Health Sci J. 2009;35(1):23–8.PubMedPubMedCentral Stoica Z, Dumitrescu D, Popescu M, Gheonea I, Gabor M, Bogdan N. Imaging of avascular necrosis of femoral head: familiar methods and newer trends. Curr Health Sci J. 2009;35(1):23–8.PubMedPubMedCentral
19.
Zurück zum Zitat Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont. 1998;11(5):491–501.PubMed Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont. 1998;11(5):491–501.PubMed
20.
Zurück zum Zitat D’Orto B, Polizzi E, Nagni M, Tetè G, Capparè P. Full Arch Implant-Prosthetic Rehabilitation in Patients with Type I Diabetes Mellitus: Retrospective Clinical Study with 10 Year Follow-Up. Int J Environ Res Public Health. 2022;19(18):11735.CrossRefPubMedPubMedCentral D’Orto B, Polizzi E, Nagni M, Tetè G, Capparè P. Full Arch Implant-Prosthetic Rehabilitation in Patients with Type I Diabetes Mellitus: Retrospective Clinical Study with 10 Year Follow-Up. Int J Environ Res Public Health. 2022;19(18):11735.CrossRefPubMedPubMedCentral
21.
Zurück zum Zitat Montemezzi P, Ferrini F, Pantaleo G, Gherlone E, Capparè P. Dental Implants with Different Neck Design: A Prospective Clinical Comparative Study with 2-Year Follow-Up. Materials. 2020;13(5):1029.CrossRefPubMedPubMedCentral Montemezzi P, Ferrini F, Pantaleo G, Gherlone E, Capparè P. Dental Implants with Different Neck Design: A Prospective Clinical Comparative Study with 2-Year Follow-Up. Materials. 2020;13(5):1029.CrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Capparè P, D’Ambrosio R, De Cunto R, Darvizeh A, Nagni M, Gherlone E. The Usage of an Air Purifier Device with HEPA 14 Filter during Dental Procedures in COVID-19 Pandemic: A Randomized Clinical Trial. Int J Environ Res Public Health. 2022;19(9):5139.CrossRefPubMedPubMedCentral Capparè P, D’Ambrosio R, De Cunto R, Darvizeh A, Nagni M, Gherlone E. The Usage of an Air Purifier Device with HEPA 14 Filter during Dental Procedures in COVID-19 Pandemic: A Randomized Clinical Trial. Int J Environ Res Public Health. 2022;19(9):5139.CrossRefPubMedPubMedCentral
Metadaten
Titel
Results of thermal osteonecrosis for implant removal on electron microscopy, implant stability, and radiographic parameters – a rat study
verfasst von
Kristian Kniha
Eva Miriam Buhl
Faruk Al-Sibai
Stephan Christian Möhlhenrich
Anna Bock
Marius Heitzer
Frank Hölzle
Ali Modabber
Publikationsdatum
01.12.2023
Verlag
BioMed Central
Erschienen in
Head & Face Medicine / Ausgabe 1/2023
Elektronische ISSN: 1746-160X
DOI
https://doi.org/10.1186/s13005-023-00349-2

Weitere Artikel der Ausgabe 1/2023

Head & Face Medicine 1/2023 Zur Ausgabe

Betalaktam-Allergie: praxisnahes Vorgehen beim Delabeling

16.05.2024 Pädiatrische Allergologie Nachrichten

Die große Mehrheit der vermeintlichen Penicillinallergien sind keine. Da das „Etikett“ Betalaktam-Allergie oft schon in der Kindheit erworben wird, kann ein frühzeitiges Delabeling lebenslange Vorteile bringen. Ein Team von Pädiaterinnen und Pädiatern aus Kanada stellt vor, wie sie dabei vorgehen.

Eingreifen von Umstehenden rettet vor Erstickungstod

15.05.2024 Fremdkörperaspiration Nachrichten

Wer sich an einem Essensrest verschluckt und um Luft ringt, benötigt vor allem rasche Hilfe. Dass Umstehende nur in jedem zweiten Erstickungsnotfall bereit waren, diese zu leisten, ist das ernüchternde Ergebnis einer Beobachtungsstudie aus Japan. Doch es gibt auch eine gute Nachricht.

Real-World-Daten sprechen eher für Dupilumab als für Op.

14.05.2024 Rhinosinusitis Nachrichten

Zur Behandlung schwerer Formen der chronischen Rhinosinusitis mit Nasenpolypen (CRSwNP) stehen seit Kurzem verschiedene Behandlungsmethoden zur Verfügung, darunter Biologika, wie Dupilumab, und die endoskopische Sinuschirurgie (ESS). Beim Vergleich der beiden Therapieoptionen war Dupilumab leicht im Vorteil.

Schwindelursache: Massagepistole lässt Otholiten tanzen

14.05.2024 Benigner Lagerungsschwindel Nachrichten

Wenn jüngere Menschen über ständig rezidivierenden Lagerungsschwindel klagen, könnte eine Massagepistole der Auslöser sein. In JAMA Otolaryngology warnt ein Team vor der Anwendung hochpotenter Geräte im Bereich des Nackens.

Update HNO

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.