Skip to main content
Erschienen in: Abdominal Radiology 8/2021

20.03.2021 | Hepatobiliary

Risk of nephrogenic systemic fibrosis in patients with impaired renal function undergoing fixed-dose gadoxetic acid-enhanced magnetic resonance imaging

verfasst von: Ti-Yung Tseng, Jeng-Hwei Tseng, Bing-Shen Huang, Shen-Yen Lin, Chun-Bing Chen, Yi-Wen Fang, Gigin Lin, Ying-Chieh Lai

Erschienen in: Abdominal Radiology | Ausgabe 8/2021

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To assess the risk of nephrogenic systemic fibrosis (NSF) in patients with renal impairment undergoing gadoxetic acid-enhanced magnetic resonance imaging.

Methods

This retrospective study included patients who had an estimated glomerular filtration rate (eGFR) below 60 mL/min per 1.73 m2 or had undergone dialysis around the time of gadoxetic acid exposure from January 2010 to November 2019. All patients received at least one intravenous injection of gadoxetic acid at a fixed dose of 2.5 mmol. The primary endpoint was the development of NSF after exposure to gadoxetic acid based on Girardi’s clinicopathological scoring system.

Results

A total of 204 patients with renal impairment received 424 injections of gadoxetic acid, of which 131 and 54 had an eGFR of 30–59 and < 30 mL/min per 1.73 m2, respectively, and 19 had undergone hemodialysis. Eighty-two patients received multiple injections, with 23 receiving five or more injections. The dose of each exposure ranged from 0.02 to 0.07 mmol/kg and the cumulative doses ranged from 0.02 to 0.45 mmol/kg. Thirty-three patients had concomitant Child–Pugh class B or C cirrhosis. No NSF was detected during follow-up (median 20 months; range 6 days to 111 months). The upper bound of the 95% confidence interval for NSF risk was 2.2% and 1.1% per patient and examination, respectively.

Conclusion

No NSF was detected in this study. However, it is premature to ascertain the risk of NSF using gadoxetic acid in patients with renal impairment and further studies are warranted.
Literatur
16.
Zurück zum Zitat Kim HJ, Lee SS, Byun JH, Kim JC, Yu CS, Park SH, Kim AY, Ha HK (2015) Incremental value of liver MR imaging in patients with potentially curable colorectal hepatic metastasis detected at CT: a prospective comparison of diffusion-weighted imaging, gadoxetic acid-enhanced MR imaging, and a combination of both MR techniques. Radiology 274 (3):712-722. https://doi.org/10.1148/radiol.14140390CrossRefPubMed Kim HJ, Lee SS, Byun JH, Kim JC, Yu CS, Park SH, Kim AY, Ha HK (2015) Incremental value of liver MR imaging in patients with potentially curable colorectal hepatic metastasis detected at CT: a prospective comparison of diffusion-weighted imaging, gadoxetic acid-enhanced MR imaging, and a combination of both MR techniques. Radiology 274 (3):712-722. https://​doi.​org/​10.​1148/​radiol.​14140390CrossRefPubMed
20.
Zurück zum Zitat Lauenstein T, Ramirez-Garrido F, Kim YH, Rha SE, Ricke J, Phongkitkarun S, Boettcher J, Gupta RT, Korpraphong P, Tanomkiat W, Furtner J, Liu PS, Henry M, Endrikat J (2015) Nephrogenic systemic fibrosis risk after liver magnetic resonance imaging with gadoxetate disodium in patients with moderate to severe renal impairment: results of a prospective, open-label, multicenter study. Invest Radiol 50 (6):416-422. https://doi.org/10.1097/rli.0000000000000145CrossRefPubMedPubMedCentral Lauenstein T, Ramirez-Garrido F, Kim YH, Rha SE, Ricke J, Phongkitkarun S, Boettcher J, Gupta RT, Korpraphong P, Tanomkiat W, Furtner J, Liu PS, Henry M, Endrikat J (2015) Nephrogenic systemic fibrosis risk after liver magnetic resonance imaging with gadoxetate disodium in patients with moderate to severe renal impairment: results of a prospective, open-label, multicenter study. Invest Radiol 50 (6):416-422. https://​doi.​org/​10.​1097/​rli.​0000000000000145​CrossRefPubMedPubMedCentral
Metadaten
Titel
Risk of nephrogenic systemic fibrosis in patients with impaired renal function undergoing fixed-dose gadoxetic acid-enhanced magnetic resonance imaging
verfasst von
Ti-Yung Tseng
Jeng-Hwei Tseng
Bing-Shen Huang
Shen-Yen Lin
Chun-Bing Chen
Yi-Wen Fang
Gigin Lin
Ying-Chieh Lai
Publikationsdatum
20.03.2021
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 8/2021
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-021-03045-4

Weitere Artikel der Ausgabe 8/2021

Abdominal Radiology 8/2021 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.