Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 5/2013

01.06.2013 | Original Paper

Systematic analysis on the relationship between luminal enhancement, convolution kernel, plaque density, and luminal diameter of coronary artery stenosis: a CT phantom study

verfasst von: Fabian Morsbach, Nicole Berger, Lotus Desbiolles, Tadea Poropat, Sebastian Leschka, Hatem Alkadhi, Paul Stolzmann

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 5/2013

Einloggen, um Zugang zu erhalten

Abstract

To systematically investigate into the relationships between luminal enhancement, convolution kernel, plaque density, and stenosis severity in coronary computed tomography (CT) angiography. A coronary phantom including 63 stenoses (stenosis severity, 10–90 %; plaque densities, −100 to 1,000 HU) was loaded with increasing solutions of contrast material (luminal enhancement, 0–700 HU) and scanned in an anthropomorphic chest. CT data was acquired with prospective triggering using 64-section dual-source CT; reconstructions were performed with soft-tissue (B26f) and sharp convolution kernels (B46f). Two blinded and independent readers quantitatively assessed luminal diameter and CT number of plaque using electronic calipers. Measurement bias between phantom dimensions and CT measurements were calculated. Multivariate linear regression models identified predictors of bias. Inter- and intra-reader agreements of luminal diameter and CT number measurements were excellent (ICCs > 0.91, p < 0.01, each). Measurement bias of luminal diameter and plaque density was significantly (p < 0.01, each) lower (−12 % and 58 HU, respectively) with B46f as opposed to B26f, especially in plaque densities >200 HU. Measurement bias was significantly (p < 0.01, each) correlated (ρ = 0.37–55 and ρ = −0.70–85) with the differences between luminal enhancement and plaque density. In multivariate models, bias of luminal diameter assessment with CT was correlated with plaque density (β = 0.09, p < 0.05). Convolution kernel (β = −0.29 and −0.38), stenosis severity (β = −0.45 and −0.38), and luminal enhancement (β = −0.11 and −0.29) represented independent (p < 0.05,each) predictors of measurement bias of luminal diameter and plaque number, respectively. Significant independent relationships exist between luminal enhancement, convolution kernel, plaque density, and luminal diameter, which have to be taken into account when performing, evaluating, and interpreting coronary CT angiography.
Literatur
1.
Zurück zum Zitat Taylor AJ, Cerqueira M, Hodgson JM, Mark D, Min J, O’Gara P, Rubin GD (2010) ACCF/SCCT/ACR/AHA/ASE/ASNC/NASCI/SCAI/SCMR 2010 Appropriate use criteria for cardiac computed tomography. A report of the american college of cardiology foundation appropriate use criteria task force, the society of cardiovascular computed tomography, the American college of radiology, the American heart association, the American society of echocardiography, the American society of nuclear cardiology, the North American society for cardiovascular imaging, the society for cardiovascular angiography and interventions, and the society for cardiovascular magnetic resonance. Circulation 122(21):e525–e555. doi:10.1161/CIR.0b013e3181fcae66 PubMedCrossRef Taylor AJ, Cerqueira M, Hodgson JM, Mark D, Min J, O’Gara P, Rubin GD (2010) ACCF/SCCT/ACR/AHA/ASE/ASNC/NASCI/SCAI/SCMR 2010 Appropriate use criteria for cardiac computed tomography. A report of the american college of cardiology foundation appropriate use criteria task force, the society of cardiovascular computed tomography, the American college of radiology, the American heart association, the American society of echocardiography, the American society of nuclear cardiology, the North American society for cardiovascular imaging, the society for cardiovascular angiography and interventions, and the society for cardiovascular magnetic resonance. Circulation 122(21):e525–e555. doi:10.​1161/​CIR.​0b013e3181fcae66​ PubMedCrossRef
2.
Zurück zum Zitat Nance JW Jr, Schlett CL, Schoepf UJ, Oberoi S, Leisy HB, Barraza JM Jr, Headden GF, Nikolaou K, Bamberg F (2012) Incremental prognostic value of different components of coronary atherosclerotic plaque at cardiac CT angiography beyond coronary calcification in patients with acute chest pain. Radiology 264(3):679–690. doi:10.1148/radiol.12112350 PubMedCrossRef Nance JW Jr, Schlett CL, Schoepf UJ, Oberoi S, Leisy HB, Barraza JM Jr, Headden GF, Nikolaou K, Bamberg F (2012) Incremental prognostic value of different components of coronary atherosclerotic plaque at cardiac CT angiography beyond coronary calcification in patients with acute chest pain. Radiology 264(3):679–690. doi:10.​1148/​radiol.​12112350 PubMedCrossRef
3.
Zurück zum Zitat Pundziute G, Schuijf JD, Jukema JW, Boersma E, de Roos A, van der Wall EE, Bax JJ (2007) Prognostic value of multislice computed tomography coronary angiography in patients with known or suspected coronary artery disease. J Am Coll Cardiol 49(1):62–70. doi:10.1016/j.jacc.2006.07.070 PubMedCrossRef Pundziute G, Schuijf JD, Jukema JW, Boersma E, de Roos A, van der Wall EE, Bax JJ (2007) Prognostic value of multislice computed tomography coronary angiography in patients with known or suspected coronary artery disease. J Am Coll Cardiol 49(1):62–70. doi:10.​1016/​j.​jacc.​2006.​07.​070 PubMedCrossRef
4.
Zurück zum Zitat van Werkhoven JM, Schuijf JD, Gaemperli O, Jukema JW, Boersma E, Wijns W, Stolzmann P, Alkadhi H, Valenta I, Stokkel MP, Kroft LJ, de Roos A, Pundziute G, Scholte A, van der Wall EE, Kaufmann PA, Bax JJ (2009) Prognostic value of multislice computed tomography and gated single-photon emission computed tomography in patients with suspected coronary artery disease. J Am Coll Cardiol 53(7):623–632. doi:10.1016/j.jacc.2008.10.043 PubMedCrossRef van Werkhoven JM, Schuijf JD, Gaemperli O, Jukema JW, Boersma E, Wijns W, Stolzmann P, Alkadhi H, Valenta I, Stokkel MP, Kroft LJ, de Roos A, Pundziute G, Scholte A, van der Wall EE, Kaufmann PA, Bax JJ (2009) Prognostic value of multislice computed tomography and gated single-photon emission computed tomography in patients with suspected coronary artery disease. J Am Coll Cardiol 53(7):623–632. doi:10.​1016/​j.​jacc.​2008.​10.​043 PubMedCrossRef
5.
Zurück zum Zitat Hoffmann U, Moselewski F, Nieman K, Jang IK, Ferencik M, Rahman AM, Cury RC, Abbara S, Joneidi-Jafari H, Achenbach S, Brady TJ (2006) Noninvasive assessment of plaque morphology and composition in culprit and stable lesions in acute coronary syndrome and stable lesions in stable angina by multidetector computed tomography. J Am Coll Cardiol 47(8):1655–1662. doi:10.1016/j.jacc.2006.01.041 PubMedCrossRef Hoffmann U, Moselewski F, Nieman K, Jang IK, Ferencik M, Rahman AM, Cury RC, Abbara S, Joneidi-Jafari H, Achenbach S, Brady TJ (2006) Noninvasive assessment of plaque morphology and composition in culprit and stable lesions in acute coronary syndrome and stable lesions in stable angina by multidetector computed tomography. J Am Coll Cardiol 47(8):1655–1662. doi:10.​1016/​j.​jacc.​2006.​01.​041 PubMedCrossRef
6.
Zurück zum Zitat Bauer RW, Thilo C, Chiaramida SA, Vogl TJ, Costello P, Schoepf UJ (2009) Noncalcified atherosclerotic plaque burden at coronary CT angiography: a better predictor of ischemia at stress myocardial perfusion imaging than calcium score and stenosis severity. AJR Am J Roentgenol 193(2):410–418. doi:10.2214/AJR.08.1277 PubMedCrossRef Bauer RW, Thilo C, Chiaramida SA, Vogl TJ, Costello P, Schoepf UJ (2009) Noncalcified atherosclerotic plaque burden at coronary CT angiography: a better predictor of ischemia at stress myocardial perfusion imaging than calcium score and stenosis severity. AJR Am J Roentgenol 193(2):410–418. doi:10.​2214/​AJR.​08.​1277 PubMedCrossRef
7.
Zurück zum Zitat Feuchtner G, Loureiro R, Bezerra H, Rocha-Filho JA, Sarwar A, Pflederer T, Marwan M, Petranovic M, Raffel CO, Brady TB, Jang IK, Achenbach S, Cury RC (2012) Quantification of coronary stenosis by dual source computed tomography in patients: a comparative study with intravascular ultrasound and invasive angiography. Eur J Radiol 81(1):83–88. doi:10.1016/j.ejrad.2010.12.008 PubMedCrossRef Feuchtner G, Loureiro R, Bezerra H, Rocha-Filho JA, Sarwar A, Pflederer T, Marwan M, Petranovic M, Raffel CO, Brady TB, Jang IK, Achenbach S, Cury RC (2012) Quantification of coronary stenosis by dual source computed tomography in patients: a comparative study with intravascular ultrasound and invasive angiography. Eur J Radiol 81(1):83–88. doi:10.​1016/​j.​ejrad.​2010.​12.​008 PubMedCrossRef
8.
Zurück zum Zitat Leber AW, Knez A, Becker A, Becker C, von Ziegler F, Nikolaou K, Rist C, Reiser M, White C, Steinbeck G, Boekstegers P (2004) Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound. J Am Coll Cardiol 43(7):1241–1247. doi:10.1016/j.jacc.2003.10.059 PubMedCrossRef Leber AW, Knez A, Becker A, Becker C, von Ziegler F, Nikolaou K, Rist C, Reiser M, White C, Steinbeck G, Boekstegers P (2004) Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound. J Am Coll Cardiol 43(7):1241–1247. doi:10.​1016/​j.​jacc.​2003.​10.​059 PubMedCrossRef
9.
Zurück zum Zitat Mahnken AH, Muhlenbruch G, Seyfarth T, Flohr T, Stanzel S, Wildberger JE, Gunther RW, Kuettner A (2006) 64-slice computed tomography assessment of coronary artery stents: a phantom study. Acta Radiol 47(1):36–42PubMedCrossRef Mahnken AH, Muhlenbruch G, Seyfarth T, Flohr T, Stanzel S, Wildberger JE, Gunther RW, Kuettner A (2006) 64-slice computed tomography assessment of coronary artery stents: a phantom study. Acta Radiol 47(1):36–42PubMedCrossRef
10.
Zurück zum Zitat Park MJ, Jung JI, Choi YS, Ann SH, Youn HJ, Jeon GN, Choi HC (2011) Coronary CT angiography in patients with high calcium score: evaluation of plaque characteristics and diagnostic accuracy. Int J Cardiovasc Imaging 27(Suppl 1):43–51. doi:10.1007/s10554-011-9970-7 PubMedCrossRef Park MJ, Jung JI, Choi YS, Ann SH, Youn HJ, Jeon GN, Choi HC (2011) Coronary CT angiography in patients with high calcium score: evaluation of plaque characteristics and diagnostic accuracy. Int J Cardiovasc Imaging 27(Suppl 1):43–51. doi:10.​1007/​s10554-011-9970-7 PubMedCrossRef
11.
Zurück zum Zitat Cademartiri F, Mollet NR, Runza G, Bruining N, Hamers R, Somers P, Knaapen M, Verheye S, Midiri M, Krestin GP, de Feyter PJ (2005) Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex vivo model of coronary computed tomography angiography. Eur Radiol 15(7):1426–1431. doi:10.1007/s00330-005-2697-x PubMedCrossRef Cademartiri F, Mollet NR, Runza G, Bruining N, Hamers R, Somers P, Knaapen M, Verheye S, Midiri M, Krestin GP, de Feyter PJ (2005) Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex vivo model of coronary computed tomography angiography. Eur Radiol 15(7):1426–1431. doi:10.​1007/​s00330-005-2697-x PubMedCrossRef
12.
Zurück zum Zitat Renker M, Nance JW Jr, Schoepf UJ, O’Brien TX, Zwerner PL, Meyer M, Kerl JM, Bauer RW, Fink C, Vogl TJ, Henzler T (2011) Evaluation of heavily calcified vessels with coronary CT angiography: comparison of iterative and filtered back projection image reconstruction. Radiology 260(2):390–399. doi:10.1148/radiol.11103574 PubMedCrossRef Renker M, Nance JW Jr, Schoepf UJ, O’Brien TX, Zwerner PL, Meyer M, Kerl JM, Bauer RW, Fink C, Vogl TJ, Henzler T (2011) Evaluation of heavily calcified vessels with coronary CT angiography: comparison of iterative and filtered back projection image reconstruction. Radiology 260(2):390–399. doi:10.​1148/​radiol.​11103574 PubMedCrossRef
13.
Zurück zum Zitat Achenbach S, Boehmer K, Pflederer T, Ropers D, Seltmann M, Lell M, Anders K, Kuettner A, Uder M, Daniel WG, Marwan M (2010) Influence of slice thickness and reconstruction kernel on the computed tomographic attenuation of coronary atherosclerotic plaque. J Cardiovasc Comput Tomogr 4(2):110–115. doi:10.1016/j.jcct.2010.01.013 PubMedCrossRef Achenbach S, Boehmer K, Pflederer T, Ropers D, Seltmann M, Lell M, Anders K, Kuettner A, Uder M, Daniel WG, Marwan M (2010) Influence of slice thickness and reconstruction kernel on the computed tomographic attenuation of coronary atherosclerotic plaque. J Cardiovasc Comput Tomogr 4(2):110–115. doi:10.​1016/​j.​jcct.​2010.​01.​013 PubMedCrossRef
14.
Zurück zum Zitat Cademartiri F, Runza G, Mollet NR, Luccichenti G, Belgrano M, Somers P, Knaapen M, Verheye S, Bruining N, Hamers R, Midiri M, De Feyter PJ, Krestin GP (2005) Influence of increasing convolution kernel filtering on plaque imaging with multislice CT using an ex vivo model of coronary angiography. Radiol Med 110(3):234–240PubMed Cademartiri F, Runza G, Mollet NR, Luccichenti G, Belgrano M, Somers P, Knaapen M, Verheye S, Bruining N, Hamers R, Midiri M, De Feyter PJ, Krestin GP (2005) Influence of increasing convolution kernel filtering on plaque imaging with multislice CT using an ex vivo model of coronary angiography. Radiol Med 110(3):234–240PubMed
16.
Zurück zum Zitat Horiguchi J, Kiguchi M, Fujioka C, Shen Y, Arie R, Sunasaka K, Ito K (2008) Radiation dose, image quality, stenosis measurement, and CT densitometry using ECG-triggered coronary 64-MDCT angiography: a phantom study. AJR Am J Roentgenol 190(2):315–320. doi:10.2214/AJR.07.2191 PubMedCrossRef Horiguchi J, Kiguchi M, Fujioka C, Shen Y, Arie R, Sunasaka K, Ito K (2008) Radiation dose, image quality, stenosis measurement, and CT densitometry using ECG-triggered coronary 64-MDCT angiography: a phantom study. AJR Am J Roentgenol 190(2):315–320. doi:10.​2214/​AJR.​07.​2191 PubMedCrossRef
17.
Zurück zum Zitat Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159–174PubMedCrossRef Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159–174PubMedCrossRef
18.
Zurück zum Zitat Cademartiri F, La Grutta L, Runza G, Palumbo A, Maffei E, Mollet NR, Bartolotta TV, Somers P, Knaapen M, Verheye S, Midiri M, Hamers R, Bruining N (2007) Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary angiography. Eur Radiol 17(7):1842–1849. doi:10.1007/s00330-006-0548-z PubMedCrossRef Cademartiri F, La Grutta L, Runza G, Palumbo A, Maffei E, Mollet NR, Bartolotta TV, Somers P, Knaapen M, Verheye S, Midiri M, Hamers R, Bruining N (2007) Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary angiography. Eur Radiol 17(7):1842–1849. doi:10.​1007/​s00330-006-0548-z PubMedCrossRef
19.
Zurück zum Zitat Maintz D, Seifarth H, Raupach R, Flohr T, Rink M, Sommer T, Ozgun M, Heindel W, Fischbach R (2006) 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents. Eur Radiol 16(4):818–826. doi:10.1007/s00330-005-0062-8 PubMedCrossRef Maintz D, Seifarth H, Raupach R, Flohr T, Rink M, Sommer T, Ozgun M, Heindel W, Fischbach R (2006) 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents. Eur Radiol 16(4):818–826. doi:10.​1007/​s00330-005-0062-8 PubMedCrossRef
20.
Zurück zum Zitat Suzuki S, Furui S, Kaminaga T, Yamauchi T (2004) Measurement of vascular diameter in vitro by automated software for CT angiography: effects of inner diameter, density of contrast medium, and convolution kernel. AJR Am J Roentgenol 182(5):1313–1317PubMedCrossRef Suzuki S, Furui S, Kaminaga T, Yamauchi T (2004) Measurement of vascular diameter in vitro by automated software for CT angiography: effects of inner diameter, density of contrast medium, and convolution kernel. AJR Am J Roentgenol 182(5):1313–1317PubMedCrossRef
21.
Zurück zum Zitat Stolzmann P, Subramanian S, Abdelbaky A, Maurovich-Horvat P, Scheffel H, Tawakol A, Hoffmann U (2011) Complementary value of cardiac FDG PET and CT for the characterization of atherosclerotic disease. Radiographics 31(5):1255–1269. doi:10.1148/rg.315115028 PubMedCrossRef Stolzmann P, Subramanian S, Abdelbaky A, Maurovich-Horvat P, Scheffel H, Tawakol A, Hoffmann U (2011) Complementary value of cardiac FDG PET and CT for the characterization of atherosclerotic disease. Radiographics 31(5):1255–1269. doi:10.​1148/​rg.​315115028 PubMedCrossRef
22.
Zurück zum Zitat Husmann L, Gaemperli O, Schepis T, Scheffel H, Valenta I, Hoefflinghaus T, Stolzmann P, Desbiolles L, Herzog BA, Leschka S, Marincek B, Alkadhi H, Kaufmann PA (2008) Accuracy of quantitative coronary angiography with computed tomography and its dependency on plaque composition: plaque composition and accuracy of cardiac CT. Int J Cardiovasc Imaging 24(8):895–904. doi:10.1007/s10554-008-9327-z PubMedCrossRef Husmann L, Gaemperli O, Schepis T, Scheffel H, Valenta I, Hoefflinghaus T, Stolzmann P, Desbiolles L, Herzog BA, Leschka S, Marincek B, Alkadhi H, Kaufmann PA (2008) Accuracy of quantitative coronary angiography with computed tomography and its dependency on plaque composition: plaque composition and accuracy of cardiac CT. Int J Cardiovasc Imaging 24(8):895–904. doi:10.​1007/​s10554-008-9327-z PubMedCrossRef
23.
Zurück zum Zitat Cademartiri F, Mollet NR, Lemos PA, Saia F, Midiri M, de Feyter PJ, Krestin GP (2006) Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography. AJR Am J Roentgenol 187(4):W430–W433. doi:10.2214/AJR.05.1406 PubMedCrossRef Cademartiri F, Mollet NR, Lemos PA, Saia F, Midiri M, de Feyter PJ, Krestin GP (2006) Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography. AJR Am J Roentgenol 187(4):W430–W433. doi:10.​2214/​AJR.​05.​1406 PubMedCrossRef
Metadaten
Titel
Systematic analysis on the relationship between luminal enhancement, convolution kernel, plaque density, and luminal diameter of coronary artery stenosis: a CT phantom study
verfasst von
Fabian Morsbach
Nicole Berger
Lotus Desbiolles
Tadea Poropat
Sebastian Leschka
Hatem Alkadhi
Paul Stolzmann
Publikationsdatum
01.06.2013
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 5/2013
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-012-0173-7

Weitere Artikel der Ausgabe 5/2013

The International Journal of Cardiovascular Imaging 5/2013 Zur Ausgabe

„Jeder Fall von plötzlichem Tod muss obduziert werden!“

17.05.2024 Plötzlicher Herztod Nachrichten

Ein signifikanter Anteil der Fälle von plötzlichem Herztod ist genetisch bedingt. Um ihre Verwandten vor diesem Schicksal zu bewahren, sollten jüngere Personen, die plötzlich unerwartet versterben, ausnahmslos einer Autopsie unterzogen werden.

Hirnblutung unter DOAK und VKA ähnlich bedrohlich

17.05.2024 Direkte orale Antikoagulanzien Nachrichten

Kommt es zu einer nichttraumatischen Hirnblutung, spielt es keine große Rolle, ob die Betroffenen zuvor direkt wirksame orale Antikoagulanzien oder Marcumar bekommen haben: Die Prognose ist ähnlich schlecht.

Schlechtere Vorhofflimmern-Prognose bei kleinem linken Ventrikel

17.05.2024 Vorhofflimmern Nachrichten

Nicht nur ein vergrößerter, sondern auch ein kleiner linker Ventrikel ist bei Vorhofflimmern mit einer erhöhten Komplikationsrate assoziiert. Der Zusammenhang besteht nach Daten aus China unabhängig von anderen Risikofaktoren.

Semaglutid bei Herzinsuffizienz: Wie erklärt sich die Wirksamkeit?

17.05.2024 Herzinsuffizienz Nachrichten

Bei adipösen Patienten mit Herzinsuffizienz des HFpEF-Phänotyps ist Semaglutid von symptomatischem Nutzen. Resultiert dieser Benefit allein aus der Gewichtsreduktion oder auch aus spezifischen Effekten auf die Herzinsuffizienz-Pathogenese? Eine neue Analyse gibt Aufschluss.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.