Abstract

Background

Acetabular bone loss in revision total hip arthroplasty can be very challenging even for fellowship-trained surgeons. Although it is uncommon, massive anterosuperior medial defects may be encountered, but treatment options have been limited and better ones are needed.

Questions/Purposes

The primary purpose of this case series is to describe a novel surgical treatment, which we call the dome technique, that can be used to address these challenging defects. The dome technique allows for the systematic reconstruction of massive anterosuperior medial defects of the acetabulum. We sought to illustrate the utility of this procedure in three patients with failed acetabular components and massive anterosuperior medial defects.

Methods

We undertook a retrospective chart review of three patients who had had Paprosky 3B bone defects and undergone revision total hip arthroplasty by the senior author between 2013 and 2016 using the dome technique. The procedure involved the use of tantalum metal augments pieced together to fill the medial defect and recreate the column support needed for jumbo cup placement. The dome technique is unusual because it allows for intra-operative customization to obtain the proper fit.

Results

At a mean of 23.6 months’ follow-up (range, 10 to 37 months), all patients had good functional outcomes; none was in need of further revision.

Conclusions

In three patients, the dome technique allowed for the anterosuperior column to be recreated by piecing together two porous metal augments to fill the medial bony void and create a stable column for a jumbo cup to be press fit. By recreating the deficient anterosuperior medial bone, the acetabulum can be downsized in a stepwise manner (with further surgery) and reconstructed in a stable fashion. This novel procedure is a unique option for the treatment of this challenging problem.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Abolghasemian M, Tangsataporn S, Sternheim A, Backstein D, Safir O, Gross AE. Combined trabecular metal acetabular shell and augment for acetabular revision with substantial bone loss: a mid-term review. Bone Joint J. 2013;95-B(2):166–172.CrossRef Abolghasemian M, Tangsataporn S, Sternheim A, Backstein D, Safir O, Gross AE. Combined trabecular metal acetabular shell and augment for acetabular revision with substantial bone loss: a mid-term review. Bone Joint J. 2013;95-B(2):166–172.CrossRef
2.
Zurück zum Zitat Berasi CCt, Berend KR, Adams JB, Ruh EL, Lombardi AV Jr. Are custom triflange acetabular components effective for reconstruction of catastrophic bone loss? Clin Orthop Relat Res. 2015;473(2):528–535.CrossRef Berasi CCt, Berend KR, Adams JB, Ruh EL, Lombardi AV Jr. Are custom triflange acetabular components effective for reconstruction of catastrophic bone loss? Clin Orthop Relat Res. 2015;473(2):528–535.CrossRef
3.
Zurück zum Zitat DeBoer DK, Christie MJ, Brinson MF, Morrison JC. Revision total hip arthroplasty for pelvic discontinuity. J Bone Joint Surg Am. 2007;89(4):835–840.CrossRef DeBoer DK, Christie MJ, Brinson MF, Morrison JC. Revision total hip arthroplasty for pelvic discontinuity. J Bone Joint Surg Am. 2007;89(4):835–840.CrossRef
4.
Zurück zum Zitat Dennis DA. Management of massive acetabular defects in revision total hip arthroplasty. J Arthroplasty. 2003;18(3 Suppl 1):121–125.CrossRef Dennis DA. Management of massive acetabular defects in revision total hip arthroplasty. J Arthroplasty. 2003;18(3 Suppl 1):121–125.CrossRef
5.
Zurück zum Zitat Goodman GP, Engh CA Jr. The custom triflange cup: build it and they will come. Bone Joint J. 2016;98-B(1 Suppl A):68–72.CrossRef Goodman GP, Engh CA Jr. The custom triflange cup: build it and they will come. Bone Joint J. 2016;98-B(1 Suppl A):68–72.CrossRef
6.
Zurück zum Zitat Kurtz S, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am. 2007;89(4):780–785.CrossRef Kurtz S, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am. 2007;89(4):780–785.CrossRef
7.
Zurück zum Zitat Kurtz SM, Lau E, Ong K, Zhao K, Kelly M, Bozic KJ. Future young patient demand for primary and revision joint replacement: national projections from 2010 to 2030. Clin Orthop Relat Res. 2009;467(10):2606–2612.CrossRef Kurtz SM, Lau E, Ong K, Zhao K, Kelly M, Bozic KJ. Future young patient demand for primary and revision joint replacement: national projections from 2010 to 2030. Clin Orthop Relat Res. 2009;467(10):2606–2612.CrossRef
8.
Zurück zum Zitat Lingaraj K, Teo YH, Bergman N. The management of severe acetabular bone defects in revision hip arthroplasty using modular porous metal components. J Bone Joint Surg Br. 2009;91(12):1555–1560.CrossRef Lingaraj K, Teo YH, Bergman N. The management of severe acetabular bone defects in revision hip arthroplasty using modular porous metal components. J Bone Joint Surg Br. 2009;91(12):1555–1560.CrossRef
9.
Zurück zum Zitat Molicnik A, Hanc M, Recnik G, Krajnc Z, Rupreht M, Fokter SK. Porous tantalum shells and augments for acetabular cup revisions. Eur J Orthop Surg Traumatol. 2014;24(6):911–917.CrossRef Molicnik A, Hanc M, Recnik G, Krajnc Z, Rupreht M, Fokter SK. Porous tantalum shells and augments for acetabular cup revisions. Eur J Orthop Surg Traumatol. 2014;24(6):911–917.CrossRef
10.
Zurück zum Zitat Nehme A, Lewallen DG, Hanssen AD. Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty. Clin Orthop Relat Res. 2004;(429):201–208.CrossRef Nehme A, Lewallen DG, Hanssen AD. Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty. Clin Orthop Relat Res. 2004;(429):201–208.CrossRef
11.
Zurück zum Zitat Paprosky WG, Perona PG, Lawrence JM. Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty. 1994;9(1):33–44.CrossRef Paprosky WG, Perona PG, Lawrence JM. Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty. 1994;9(1):33–44.CrossRef
12.
Zurück zum Zitat Sheth NP, Nelson CL, Springer BD, Fehring TK, Paprosky WG. Acetabular bone loss in revision total hip arthroplasty: evaluation and management. J Am Acad Orthop Surg. 2013;21(3):128–139.CrossRef Sheth NP, Nelson CL, Springer BD, Fehring TK, Paprosky WG. Acetabular bone loss in revision total hip arthroplasty: evaluation and management. J Am Acad Orthop Surg. 2013;21(3):128–139.CrossRef
13.
Zurück zum Zitat Sheth NP, Melnic CM, Paprosky WG. Acetabular distraction: an alternative for severe acetabular bone loss and chronic pelvic discontinuity. Bone Joint J. 2014;96-B(11 Supple A):36–42.CrossRef Sheth NP, Melnic CM, Paprosky WG. Acetabular distraction: an alternative for severe acetabular bone loss and chronic pelvic discontinuity. Bone Joint J. 2014;96-B(11 Supple A):36–42.CrossRef
14.
Zurück zum Zitat Sporer SM, Bottros JJ, Hulst JB, Kancherla VK, Moric M, Paprosky WG. Acetabular distraction: an alternative for severe defects with chronic pelvic discontinuity? Clin Orthop Relat Res. 2012;470(11):3156–3163.CrossRef Sporer SM, Bottros JJ, Hulst JB, Kancherla VK, Moric M, Paprosky WG. Acetabular distraction: an alternative for severe defects with chronic pelvic discontinuity? Clin Orthop Relat Res. 2012;470(11):3156–3163.CrossRef
15.
Zurück zum Zitat Taunton MJ, Fehring TK, Edwards P, Bernasek T, Holt GE, Christie MJ. Pelvic discontinuity treated with custom triflange component: a reliable option. Clin Orthop Relat Res. 2012;470(2):428–434.CrossRef Taunton MJ, Fehring TK, Edwards P, Bernasek T, Holt GE, Christie MJ. Pelvic discontinuity treated with custom triflange component: a reliable option. Clin Orthop Relat Res. 2012;470(2):428–434.CrossRef
16.
Zurück zum Zitat Weeden SH, Schmidt RH. The use of tantalum porous metal implants for Paprosky 3A and 3B defects. J Arthroplasty. 2007;22(6 Suppl 2):151–155.CrossRef Weeden SH, Schmidt RH. The use of tantalum porous metal implants for Paprosky 3A and 3B defects. J Arthroplasty. 2007;22(6 Suppl 2):151–155.CrossRef
17.
Zurück zum Zitat Wind MA Jr, Swank ML, Sorger JI. Short-term results of a custom triflange acetabular component for massive acetabular bone loss in revision THA. Orthopedics. 2013;36(3):e260–e265.CrossRef Wind MA Jr, Swank ML, Sorger JI. Short-term results of a custom triflange acetabular component for massive acetabular bone loss in revision THA. Orthopedics. 2013;36(3):e260–e265.CrossRef
Metadaten
Titel
The Dome Technique, an Option for Massive Anterosuperior Medial Acetabular Bone Loss: A Retrospective Case Series
verfasst von
Christopher M. Melnic, MD
Matthew Knedel, MD
P. Maxwell Courtney, MD
Neil P. Sheth, MD
Wayne G. Paprosky, MD
Publikationsdatum
16.12.2019
Verlag
Springer US
Erschienen in
HSS Journal ® / Ausgabe Sonderheft 2/2020
Print ISSN: 1556-3316
Elektronische ISSN: 1556-3324
DOI
https://doi.org/10.1007/s11420-019-09730-x

Weitere Artikel der Sonderheft 2/2020

HSS Journal ® 2/2020 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Lever-Sign-Test hilft beim Verdacht auf Kreuzbandriss

15.05.2024 Vordere Kreuzbandruptur Nachrichten

Mit dem Hebelzeichen-Test lässt sich offenbar recht zuverlässig feststellen, ob ein vorderes Kreuzband gerissen ist. In einer Metaanalyse war die Vorhersagekraft vor allem bei positivem Testergebnis hoch.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.