Abstract

The medical literature on the effect of electronic control devices (ECD) on muscle injury is sparse. In this paper, we examine pooled data from five human studies that used creatine kinase (CK) as a marker for muscle injury. CK was measured in five separate studies involving four TASER ECDs with different exposure durations and number of circuits or contact points. Device type, exposure duration, number of circuits or contact points, and CK values at baseline and 24 h after exposure were pooled from these previous studies. Data were analyzed to determine the correlation of CK to duration of exposure, number of contact points, and distance between the probes. The pooled results contained 163 subjects. Seven were withdrawn due to incomplete data, leaving 156 subjects for analysis (median age 36, range 19–67, 93.6% male). 121 (77.6%) subjects had 2 contacts points, 10 (6.4%) had 3 contact points, 18 (11.5%) had 4 contact points, and 7 (4.5%) had 6 contact points. 81 (51.9%) subjects had a 5-s exposure, 64 (41.0%) a 10-s exposure, and, 11 (7.1%) a 30-s exposure. Median baseline CK (145 U/l, IQR 104–217, range 12–1956) did not differ between groups (P = 0.213 for number of contact points, 0.124 for duration). For the number of contacts, the median change in CK for 2 points of contact was 32 (IQR −1 to 1513, range −205 to 1821), for 3 was 1456 (IQR 634–1868, range 101–25452), for 4 was 887 (IQR 285–7481, range −1054 to 7481), and for 6 was 846 (IQR 57–1149, range −8 to 2309), (P < 0.001). For duration, the median change in CK for 5 s was 26.5 (IQR −8 to 109, range −1054 to 2309), for 10 s was 303 (IQR 34.5–1073, range −205 to 25452), and for 30 s was 47 (IQR 23–82, range −140 to 364), (P < 0.001). There was a relationship between the number of points of contact and the change in CK (P < 0.001) but not a relationship between the duration and the change in CK (P = 0.496). The median spread between the probe pairs for our pooled data was 40 cm, with a range from 18 to 70 cm (n = 76). The correlation between the change in CK and spread between the probe pairs was 0.16 at baseline (P = 0.18), and 0.24 at 24 h (P = 0.04) by Spearman’s rank correlation. ECD exposure can cause a modest increase in CK. Although we cannot draw conclusions about the individual devices included in this analysis, our findings indicated that multiple contact points or exposures may result in a larger increase in CK, but the duration of the exposure does not appear to have a significant effect on CK. There is a correlation between the distance between the probes and the change in CK.
Literatur
1.
Zurück zum Zitat Reilly J, Diamant A, Comeaux J. Dosimetry considerations for electrical stun devices. Phys Med Biol. 2009;54:1319–35.CrossRef Reilly J, Diamant A, Comeaux J. Dosimetry considerations for electrical stun devices. Phys Med Biol. 2009;54:1319–35.CrossRef
2.
Zurück zum Zitat Despa F, Basati S, Zhang Z, D’Andrea J, Reilly J, Bodnar E, Lee R. Electromuscular incapacitation results from stimulation of spinal reflexes. Bioelectromagnetics. 2009;30:411–21.CrossRefPubMed Despa F, Basati S, Zhang Z, D’Andrea J, Reilly J, Bodnar E, Lee R. Electromuscular incapacitation results from stimulation of spinal reflexes. Bioelectromagnetics. 2009;30:411–21.CrossRefPubMed
3.
Zurück zum Zitat Sun H, Webster J. Estimating neuromuscular stimulation within the human torso with TASER stimulus. Phys Med Biol. 2007;52:6401–11.CrossRefPubMed Sun H, Webster J. Estimating neuromuscular stimulation within the human torso with TASER stimulus. Phys Med Biol. 2007;52:6401–11.CrossRefPubMed
4.
Zurück zum Zitat Ho JD, Miner JR, Lakireddy DR, et al. Cardiovascular and physiologic effects of conducted electrical weapon discharge in resting adults. Acad Emerg Med. 2006;13:589–95.CrossRefPubMed Ho JD, Miner JR, Lakireddy DR, et al. Cardiovascular and physiologic effects of conducted electrical weapon discharge in resting adults. Acad Emerg Med. 2006;13:589–95.CrossRefPubMed
5.
Zurück zum Zitat Dawes D, Ho J, Reardon R, Sweeney J, Miner J. The physiologic effects of multiple simultaneous electronic control device discharges. West J Emerg Med. 2010;11:49–56.PubMed Dawes D, Ho J, Reardon R, Sweeney J, Miner J. The physiologic effects of multiple simultaneous electronic control device discharges. West J Emerg Med. 2010;11:49–56.PubMed
6.
Zurück zum Zitat Brancaccio P, Maffulli N, Buonauro R, Limongelli F. Serum enzyme monitoring in sports medicine. Clin Sports Med. 2008;27:1–18.CrossRefPubMed Brancaccio P, Maffulli N, Buonauro R, Limongelli F. Serum enzyme monitoring in sports medicine. Clin Sports Med. 2008;27:1–18.CrossRefPubMed
7.
Zurück zum Zitat Jauchem J, Sherry C, Fines D, Cook MC. Acidosis, lactate, electrolytes, muscle enzymes, and other factors in the blood of Sus scrofa following repeated TASER exposures. Forensic Sci Int. 2006;161:20–30.CrossRefPubMed Jauchem J, Sherry C, Fines D, Cook MC. Acidosis, lactate, electrolytes, muscle enzymes, and other factors in the blood of Sus scrofa following repeated TASER exposures. Forensic Sci Int. 2006;161:20–30.CrossRefPubMed
8.
Zurück zum Zitat Jauchem J, Beason C, Cook M. Acute effects of an alternative electronic control device waveform in swine. Forensic Sci Med Pathol. 2009;5:2–10.CrossRefPubMed Jauchem J, Beason C, Cook M. Acute effects of an alternative electronic control device waveform in swine. Forensic Sci Med Pathol. 2009;5:2–10.CrossRefPubMed
9.
Zurück zum Zitat Jauchem J, Cook M, Beason C. Blood factors of Sus scrofa following a series of three TASER electronic control device exposures. Forensic Sci Int. 2008;175:166–70.CrossRefPubMed Jauchem J, Cook M, Beason C. Blood factors of Sus scrofa following a series of three TASER electronic control device exposures. Forensic Sci Int. 2008;175:166–70.CrossRefPubMed
10.
Zurück zum Zitat Dennis A, Valentino D, Walter R, Nagy K, Winners J, Bokhari F, Wiley D, Joseph K, Roberts R. Acute effects of TASER X26 discharges in a swine model. J Trauma. 2007;63:581–90.CrossRefPubMed Dennis A, Valentino D, Walter R, Nagy K, Winners J, Bokhari F, Wiley D, Joseph K, Roberts R. Acute effects of TASER X26 discharges in a swine model. J Trauma. 2007;63:581–90.CrossRefPubMed
12.
Zurück zum Zitat Bozeman W, Hauda W, Heck J, Graham D, Martin B, Winslow J. Safety and injury profile of conducted electrical weapons used by law enforcement officers against criminal suspects. Ann Emerg Med. 2009;53(4):480–9.CrossRefPubMed Bozeman W, Hauda W, Heck J, Graham D, Martin B, Winslow J. Safety and injury profile of conducted electrical weapons used by law enforcement officers against criminal suspects. Ann Emerg Med. 2009;53(4):480–9.CrossRefPubMed
13.
Zurück zum Zitat Bui E, Sourkes M, Wennberg R. Generalized tonic-clonic seizure after a TASER shot to the head. CMAJ. 2009;180(6):625–6.PubMed Bui E, Sourkes M, Wennberg R. Generalized tonic-clonic seizure after a TASER shot to the head. CMAJ. 2009;180(6):625–6.PubMed
14.
Zurück zum Zitat Hick J, Smith S, Lynch M. Metabolic acidosis in restraint-associated cardiac arrest: a case series. Acad Emerg Med. 1999;6(3):239–43.CrossRefPubMed Hick J, Smith S, Lynch M. Metabolic acidosis in restraint-associated cardiac arrest: a case series. Acad Emerg Med. 1999;6(3):239–43.CrossRefPubMed
15.
Zurück zum Zitat Merigian K, Roberts J. Cocaine intoxication: hyperpyrexia, rhabdomyolysis, and acute renal failure. Clin Toxicol. 1987;25:135–48.CrossRef Merigian K, Roberts J. Cocaine intoxication: hyperpyrexia, rhabdomyolysis, and acute renal failure. Clin Toxicol. 1987;25:135–48.CrossRef
16.
Zurück zum Zitat Menashe P, Gottlieb J. Hyperthermia, rhabdomyolysis, and myoglobinuric renal failure after recreational use of cocaine. South Med J. 1988;81(3):379–81.PubMed Menashe P, Gottlieb J. Hyperthermia, rhabdomyolysis, and myoglobinuric renal failure after recreational use of cocaine. South Med J. 1988;81(3):379–81.PubMed
17.
Zurück zum Zitat Sinert R, Kohl L, Reinone T, Scalea T. Exercise-induced rhabdomyolysis. Ann Emerg Med. 1994;23(6):1301–6.CrossRefPubMed Sinert R, Kohl L, Reinone T, Scalea T. Exercise-induced rhabdomyolysis. Ann Emerg Med. 1994;23(6):1301–6.CrossRefPubMed
18.
Zurück zum Zitat Lin AC-M, Lin C-M, Wang T-L, Leu J-G. Rhabdomyolysis in 119 students after repetitive exercise. Br J Sports Med. 2005;39:e3.CrossRefPubMed Lin AC-M, Lin C-M, Wang T-L, Leu J-G. Rhabdomyolysis in 119 students after repetitive exercise. Br J Sports Med. 2005;39:e3.CrossRefPubMed
19.
Zurück zum Zitat Welch R, Todd K, Krause G. Incidence of cocaine-associated rhabdomyolysis. Ann Emerg Med. 1991;20(2):154–7.CrossRefPubMed Welch R, Todd K, Krause G. Incidence of cocaine-associated rhabdomyolysis. Ann Emerg Med. 1991;20(2):154–7.CrossRefPubMed
20.
Zurück zum Zitat Goldstein R, DesLauriers C, Burda A. Cocaine: history, social implications, and toxicity—a review. Dis Mon. 2009;55:6–38.CrossRefPubMed Goldstein R, DesLauriers C, Burda A. Cocaine: history, social implications, and toxicity—a review. Dis Mon. 2009;55:6–38.CrossRefPubMed
21.
Zurück zum Zitat Horowitz B, Panacek E, Jouriles N. Severe rhabdomyolysis with renal failure after intranasal cocaine use. J Emerg Med. 1997;15(6):833–7.CrossRefPubMed Horowitz B, Panacek E, Jouriles N. Severe rhabdomyolysis with renal failure after intranasal cocaine use. J Emerg Med. 1997;15(6):833–7.CrossRefPubMed
22.
Zurück zum Zitat Roth D, Alarcon F, Fernandez J, Preston R, Bourgoignie J. Acute rhabdomyolysis associated with cocaine intoxication. N Engl J Med. 1988;319:673–7.CrossRefPubMed Roth D, Alarcon F, Fernandez J, Preston R, Bourgoignie J. Acute rhabdomyolysis associated with cocaine intoxication. N Engl J Med. 1988;319:673–7.CrossRefPubMed
23.
Zurück zum Zitat Albertson T, Derlet R, Van Hoozen B. Methamphetamine and the expanding complications of amphetamines. West J Med. 1999;170:214–9.PubMed Albertson T, Derlet R, Van Hoozen B. Methamphetamine and the expanding complications of amphetamines. West J Med. 1999;170:214–9.PubMed
24.
Zurück zum Zitat Kedrick WC, Hull AR, Knochel JP. Rhabdomyolyis and shock after intravenuous amphetamine administration. Ann Int Med. 1977;86(4):381–7. Kedrick WC, Hull AR, Knochel JP. Rhabdomyolyis and shock after intravenuous amphetamine administration. Ann Int Med. 1977;86(4):381–7.
25.
Zurück zum Zitat Vanholder R, Sever M, Erek E, Lameire N. Rhabdomyolysis. J Am Soc Nephrol. 2000;11:1553–61.PubMed Vanholder R, Sever M, Erek E, Lameire N. Rhabdomyolysis. J Am Soc Nephrol. 2000;11:1553–61.PubMed
26.
Zurück zum Zitat Tan W, Herzlich B, Funaro R, Koutelos K, Pagala M, Amaladevi B, Grob D. Rhabdomyolysis and myoglobinuric acute renal failure associated with classic heat stroke. South Med J. 1995;88(10):1065–8.PubMed Tan W, Herzlich B, Funaro R, Koutelos K, Pagala M, Amaladevi B, Grob D. Rhabdomyolysis and myoglobinuric acute renal failure associated with classic heat stroke. South Med J. 1995;88(10):1065–8.PubMed
27.
Zurück zum Zitat Heatstroke and rhabdomyolysis presenting as fulminant hepatic failure. Postgrad Med J. 1988;64(748):157–9. Heatstroke and rhabdomyolysis presenting as fulminant hepatic failure. Postgrad Med J. 1988;64(748):157–9.
28.
Zurück zum Zitat Enoka RM. Morphologic features and activation patterns of motor units. J Clin Neurophysiol. 1995;12:538–59.CrossRefPubMed Enoka RM. Morphologic features and activation patterns of motor units. J Clin Neurophysiol. 1995;12:538–59.CrossRefPubMed
29.
Zurück zum Zitat Ding J, Wexler A, Binder-MacLeod SA. A mathematical model that predicts the force-frequency relationship of human skeletal muscle. Muscle Nerve. 2002;26:477–85.CrossRefPubMed Ding J, Wexler A, Binder-MacLeod SA. A mathematical model that predicts the force-frequency relationship of human skeletal muscle. Muscle Nerve. 2002;26:477–85.CrossRefPubMed
30.
Zurück zum Zitat Johnson MA, Polfar J, Weightman D, Appleton D. Data on the distribution of fiber types in thirty-six human muscles: an autopsy study. J Neurol Sci. 1973;18:111–29.CrossRefPubMed Johnson MA, Polfar J, Weightman D, Appleton D. Data on the distribution of fiber types in thirty-six human muscles: an autopsy study. J Neurol Sci. 1973;18:111–29.CrossRefPubMed
31.
Zurück zum Zitat Gregory CM, Bickel CS. Recruitment patterns in human skeletal muscle during electrical stimulation. Phys Ther. 2005;85:358–64.PubMed Gregory CM, Bickel CS. Recruitment patterns in human skeletal muscle during electrical stimulation. Phys Ther. 2005;85:358–64.PubMed
Metadaten
Titel
The effect of an electronic control device on muscle injury as determined by creatine kinase enzyme
verfasst von
Donald M. Dawes
Jeffrey D. Ho
James D. Sweeney
Erik J. Lundin
Sebastian N. Kunz
James R. Miner
Publikationsdatum
01.03.2011
Verlag
Springer US
Erschienen in
Forensic Science, Medicine and Pathology / Ausgabe 1/2011
Print ISSN: 1547-769X
Elektronische ISSN: 1556-2891
DOI
https://doi.org/10.1007/s12024-010-9187-4

Weitere Artikel der Ausgabe 1/2011

Forensic Science, Medicine and Pathology 1/2011 Zur Ausgabe

Neu im Fachgebiet Pathologie

Molekularpathologische Untersuchungen im Wandel der Zeit

Open Access Biomarker Leitthema

Um auch an kleinen Gewebeproben zuverlässige und reproduzierbare Ergebnisse zu gewährleisten ist eine strenge Qualitätskontrolle in jedem Schritt des Arbeitsablaufs erforderlich. Eine nicht ordnungsgemäße Prüfung oder Behandlung des …

Vergleichende Pathologie in der onkologischen Forschung

Pathologie Leitthema

Die vergleichende experimentelle Pathologie („comparative experimental pathology“) ist ein Fachbereich an der Schnittstelle von Human- und Veterinärmedizin. Sie widmet sich der vergleichenden Erforschung von Gemeinsamkeiten und Unterschieden von …

Gastrointestinale Stromatumoren

Open Access GIST CME-Artikel

Gastrointestinale Stromatumoren (GIST) stellen seit über 20 Jahren ein Paradigma für die zielgerichtete Therapie mit Tyrosinkinaseinhibitoren dar. Eine elementare Voraussetzung für eine mögliche neoadjuvante oder adjuvante Behandlung bei …

Personalisierte Medizin in der Onkologie

Aufgrund des erheblichen technologischen Fortschritts in der molekularen und genetischen Diagnostik sowie zunehmender Erkenntnisse über die molekulare Pathogenese von Krankheiten hat in den letzten zwei Jahrzehnten ein grundlegender …