Skip to main content
Erschienen in: European Archives of Oto-Rhino-Laryngology 4/2016

01.04.2016 | Otology

The sensitivity and accuracy of a cone beam CT in detecting the chorda tympani

verfasst von: Harukazu Hiraumi, Ryo Suzuki, Norio Yamamoto, Tatsunori Sakamoto, Juichi Ito

Erschienen in: European Archives of Oto-Rhino-Laryngology | Ausgabe 4/2016

Einloggen, um Zugang zu erhalten

Abstract

The facial recess approach through posterior tympanotomy is the standard approach in cochlear implantation surgery. The size of the facial recess is highly variable, depending on the course of the chorda tympani. Despite their clinical importance, little is known about the sensitivity and accuracy of imaging studies in the detection of the chorda tympani. A total of 13 human temporal bones were included in this study. All of the temporal bones were submitted to a cone beam CT (Accuitomo, Morita, Japan). The multi-planar reconstruction images were rotated around the mastoid portion of the facial nerve to locate the branches of the facial nerve. A branch was diagnosed as the chorda tympani when it entered the tympanic cavity near the notch of Rivinus. The distance between the bifurcation and the tip of the short crus of the incus was measured. In all temporal bones, the canal of the chorda tympani or the posterior canaliculus was detected. In the CT-based evaluation, the average distance from the bifurcation to the incus short crus was 12.6 mm (8.3–15.8 mm). The actual distance after dissection was 12.4 mm (8.2–16.4 mm). The largest difference between the distances evaluated with the two procedures was 1.1 mm. Cone beam CT is very useful in detecting the course of the chorda tympani within the temporal bone. The measured distance is accurate.
Literatur
2.
Zurück zum Zitat Zonneveld FW, van Waes PF, Damsma H, Rabischong P, Vignaud J (1983) Direct multiplanar computed tomography of the petrous bone. Radiographics 3(3):400–449CrossRef Zonneveld FW, van Waes PF, Damsma H, Rabischong P, Vignaud J (1983) Direct multiplanar computed tomography of the petrous bone. Radiographics 3(3):400–449CrossRef
3.
Zurück zum Zitat Cooper MH, Archer CR, Kveton JF (1987) Correlation of high-resolution computed tomography and gross anatomic sections of the temporal bone: part I. The facial nerve. Am J Otol 8(5):375–384PubMed Cooper MH, Archer CR, Kveton JF (1987) Correlation of high-resolution computed tomography and gross anatomic sections of the temporal bone: part I. The facial nerve. Am J Otol 8(5):375–384PubMed
4.
Zurück zum Zitat Parlier-Cuau C, Champsaur P, Perrin E, Rabischong P, Lassau JP (1998) High-resolution computed tomography of the canals of the temporal bone: anatomic correlations. Surg Radiol Anat SRA 20(6):437–444CrossRefPubMed Parlier-Cuau C, Champsaur P, Perrin E, Rabischong P, Lassau JP (1998) High-resolution computed tomography of the canals of the temporal bone: anatomic correlations. Surg Radiol Anat SRA 20(6):437–444CrossRefPubMed
7.
Zurück zum Zitat Erovic BM, Chan HH, Daly MJ, Pothier DD, Yu E, Coulson C et al (2014) Intraoperative cone-beam computed tomography and multi-slice computed tomography in temporal bone imaging for surgical treatment. Otolaryngol Head Neck Surg 150(1):107–114. doi:10.1177/0194599813510862 CrossRefPubMed Erovic BM, Chan HH, Daly MJ, Pothier DD, Yu E, Coulson C et al (2014) Intraoperative cone-beam computed tomography and multi-slice computed tomography in temporal bone imaging for surgical treatment. Otolaryngol Head Neck Surg 150(1):107–114. doi:10.​1177/​0194599813510862​ CrossRefPubMed
8.
Zurück zum Zitat Shin KJ, Gil YC, Lee JY, Kim JN, Song WC, Koh KS (2014) Three-dimensional study of the facial canal using microcomputed tomography for improved anatomical comprehension. Anat Rec 297(10):1808–1816. doi:10.1002/Ar.22977 CrossRef Shin KJ, Gil YC, Lee JY, Kim JN, Song WC, Koh KS (2014) Three-dimensional study of the facial canal using microcomputed tomography for improved anatomical comprehension. Anat Rec 297(10):1808–1816. doi:10.​1002/​Ar.​22977 CrossRef
9.
Zurück zum Zitat Jeon EJ, Jun B, Song JN, Kim JE, Lee DH, Chang KH (2013) Surgical and radiologic anatomy of a cochleostomy produced via posterior tympanotomy for cochlear implantation based on three-dimensional reconstructed temporal bone CT images. Surg Radiol Anat SRA 35(6):471–475. doi:10.1007/s00276-012-1061-5 CrossRefPubMed Jeon EJ, Jun B, Song JN, Kim JE, Lee DH, Chang KH (2013) Surgical and radiologic anatomy of a cochleostomy produced via posterior tympanotomy for cochlear implantation based on three-dimensional reconstructed temporal bone CT images. Surg Radiol Anat SRA 35(6):471–475. doi:10.​1007/​s00276-012-1061-5 CrossRefPubMed
10.
Zurück zum Zitat Noble JH, Warren FM, Labadie RF, Dawant BM (2008) Automatic segmentation of the facial nerve and chorda tympani in CT images using spatially dependent feature values. Med Phys 35(12):5375–5384CrossRefPubMedPubMedCentral Noble JH, Warren FM, Labadie RF, Dawant BM (2008) Automatic segmentation of the facial nerve and chorda tympani in CT images using spatially dependent feature values. Med Phys 35(12):5375–5384CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Bamba J, Araki K, Endo A, Okano T (2013) Image quality assessment of three cone beam CT machines using the SEDENTEXCT CT phantom. Dento Maxillofac Radiol 42(8):20120445. doi:10.1259/dmfr.20120445 CrossRef Bamba J, Araki K, Endo A, Okano T (2013) Image quality assessment of three cone beam CT machines using the SEDENTEXCT CT phantom. Dento Maxillofac Radiol 42(8):20120445. doi:10.​1259/​dmfr.​20120445 CrossRef
13.
Zurück zum Zitat Pauwels R, Beinsberger J, Stamatakis H, Tsiklakis K, Walker A, Bosmans H et al (2012) Comparison of spatial and contrast resolution for cone-beam computed tomography scanners. Oral Surg Oral Med Oral Pathol Oral Radiol 114(1):127–135. doi:10.1016/j.oooo.2012.01.020 CrossRefPubMed Pauwels R, Beinsberger J, Stamatakis H, Tsiklakis K, Walker A, Bosmans H et al (2012) Comparison of spatial and contrast resolution for cone-beam computed tomography scanners. Oral Surg Oral Med Oral Pathol Oral Radiol 114(1):127–135. doi:10.​1016/​j.​oooo.​2012.​01.​020 CrossRefPubMed
Metadaten
Titel
The sensitivity and accuracy of a cone beam CT in detecting the chorda tympani
verfasst von
Harukazu Hiraumi
Ryo Suzuki
Norio Yamamoto
Tatsunori Sakamoto
Juichi Ito
Publikationsdatum
01.04.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
European Archives of Oto-Rhino-Laryngology / Ausgabe 4/2016
Print ISSN: 0937-4477
Elektronische ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-015-3647-0

Weitere Artikel der Ausgabe 4/2016

European Archives of Oto-Rhino-Laryngology 4/2016 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

HNO-Op. auch mit über 90?

16.04.2024 HNO-Chirurgie Nachrichten

Mit Blick auf das Risiko für Komplikationen nach elektiven Eingriffen im HNO-Bereich scheint das Alter der Patienten kein ausschlaggebender Faktor zu sein. Entscheidend ist offenbar, wie fit die Betroffenen tatsächlich sind.

Intrakapsuläre Tonsillektomie gewinnt an Boden

16.04.2024 Tonsillektomie Nachrichten

Gegenüber der vollständigen Entfernung der Gaumenmandeln hat die intrakapsuläre Tonsillektomie einige Vorteile, wie HNO-Fachleute aus den USA hervorheben. Sie haben die aktuelle Literatur zu dem Verfahren gesichtet.

Update HNO

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.