Skip to main content
Erschienen in: International Journal of Computer Assisted Radiology and Surgery 7/2015

01.07.2015 | Original Article

Transorbital target localization with augmented ophthalmologic surgical endoscopy

verfasst von: Michael P. DeLisi, Louise A. Mawn, Robert L. Galloway Jr.

Erschienen in: International Journal of Computer Assisted Radiology and Surgery | Ausgabe 7/2015

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Access to the space behind the eyeball is limited by the position of the globe anteriorly, the neurovascular structures embedded in fat posteriorly, and the tight bony confine of the orbit. These anatomical relationships have impeded application of minimally invasive procedures to the region, such as foreign body removal, tumor biopsy, or the administration of medical therapy directly to the optic nerve. An image-guided system was developed using a magnetically tracked flexible endoscope to navigate behind the eye, with the aim of enabling accurate transorbital surgery to user-specified target locations.

Methods

Targets were defined by microspherical bulbs containing water or gadolinium contrast, with differing visible coloring agent. Six living pigs were anesthetized and two microspheres of differing color and contrast content were implanted in the fat tissue of each orbit. Preoperative T1-weighted MRI volumes were obtained and registered intraoperatively. The system capabilities were tested with a series of targeted surgical interventions. The surgeon was required to navigate the endoscope to each lucent microsphere and identify it by color. For three pigs, 3D/2D registration was performed such that the target’s image volume coordinates were used to display its location on real-time endoscope video.

Results

The ophthalmologic surgeon was able to correctly identify every target by color, with average intervention time of 24.2 min without enhancement and 3.2 min with enhancement. This difference is highly statistically significant \((p < 0.02)\) for reduction in localization time.

Conclusions

Accurate transorbital target localization is possible in-vivo using image-guided transorbital endoscopy, while endoscopic enhancement through the use of video augmentation significantly reduces procedure time.
Literatur
2.
Zurück zum Zitat McKinnon SJ, Goldberg LD, Peeples P, Walt JG, Bramley TJ (2008) Current management of glaucoma and the need for complete therapy. Am J Manag Care 14:S20–S27PubMed McKinnon SJ, Goldberg LD, Peeples P, Walt JG, Bramley TJ (2008) Current management of glaucoma and the need for complete therapy. Am J Manag Care 14:S20–S27PubMed
3.
Zurück zum Zitat Levin LA, Peeples P (2008) History of neuroprotection and rationale as a therapy for glaucoma. Am J Manag Care 14:S11–S14PubMed Levin LA, Peeples P (2008) History of neuroprotection and rationale as a therapy for glaucoma. Am J Manag Care 14:S11–S14PubMed
4.
Zurück zum Zitat Lambert WS, Ruiz L, Crish SD, Wheeler LA, Calkins DJ (2011) Brimonidine prevents axonal and somatic degeneration of retinal ganglion cell neurons. Mol Neurodegener 6(4):1–14 Lambert WS, Ruiz L, Crish SD, Wheeler LA, Calkins DJ (2011) Brimonidine prevents axonal and somatic degeneration of retinal ganglion cell neurons. Mol Neurodegener 6(4):1–14
5.
Zurück zum Zitat Krupin T, Liebmann JM, Greenfield DS, Ritch R, Gardiner S (2011) A randomized trial of brimonidine versus timolol in preserving visual function: results from the low-pressure glaucoma treatment study. Am J Ophthalmol 151:671–681PubMedCrossRef Krupin T, Liebmann JM, Greenfield DS, Ritch R, Gardiner S (2011) A randomized trial of brimonidine versus timolol in preserving visual function: results from the low-pressure glaucoma treatment study. Am J Ophthalmol 151:671–681PubMedCrossRef
6.
Zurück zum Zitat Geroski DH, Edelhauser HF (2000) Drug delivery for posterior segment eye disease. Investig Ophthalmol Vis Sci 41(5):961–964 Geroski DH, Edelhauser HF (2000) Drug delivery for posterior segment eye disease. Investig Ophthalmol Vis Sci 41(5):961–964
7.
Zurück zum Zitat Balakrishnan K, Moe KS (2011) Applications and outcomes of orbital and transorbital endoscopic surgery. Otolaryngol Head Neck Surg 144(5):815–820PubMedCrossRef Balakrishnan K, Moe KS (2011) Applications and outcomes of orbital and transorbital endoscopic surgery. Otolaryngol Head Neck Surg 144(5):815–820PubMedCrossRef
8.
Zurück zum Zitat Mawn LA, Shen J-H, Jordan DR, Joos KM (2004) Development of an orbital endoscope for use with the free electron laser. Ophthalmic Plast Reconstr Surg 20(2):150–157CrossRef Mawn LA, Shen J-H, Jordan DR, Joos KM (2004) Development of an orbital endoscope for use with the free electron laser. Ophthalmic Plast Reconstr Surg 20(2):150–157CrossRef
9.
Zurück zum Zitat Atuegwu NC, Mawn LA, Galloway RL (2007) Transorbital endoscopic image guidance. In: Proceedings of the 29th annual IEEE engineering in medicine and biology society conference, pp 4663–4666 Atuegwu NC, Mawn LA, Galloway RL (2007) Transorbital endoscopic image guidance. In: Proceedings of the 29th annual IEEE engineering in medicine and biology society conference, pp 4663–4666
10.
Zurück zum Zitat Stefansic JD, Bass WA, Hartmann SL, Beasley RA, Sinha TK, Cash DM, Herline AJ, Galloway RL (2002) Design and implementation of a PC-based image-guided surgical system. Comput Methods Programs Biomed 69(3):211–224PubMedCrossRef Stefansic JD, Bass WA, Hartmann SL, Beasley RA, Sinha TK, Cash DM, Herline AJ, Galloway RL (2002) Design and implementation of a PC-based image-guided surgical system. Comput Methods Programs Biomed 69(3):211–224PubMedCrossRef
11.
Zurück zum Zitat Ingram M-C, Atuegwu NC, Mawn LA, Galloway RL (2011) Transorbital therapy delivery—phantom testing. In: Proceedings of the SPIE medical imaging, vol 7964 Ingram M-C, Atuegwu NC, Mawn LA, Galloway RL (2011) Transorbital therapy delivery—phantom testing. In: Proceedings of the SPIE medical imaging, vol 7964
12.
Zurück zum Zitat Sielhorst T, Feuerstein M, Navab N (2008) Advanced medical displays: a literature review of augmented reality. J Disp Technol 4(4):451–467CrossRef Sielhorst T, Feuerstein M, Navab N (2008) Advanced medical displays: a literature review of augmented reality. J Disp Technol 4(4):451–467CrossRef
13.
Zurück zum Zitat Freysinger W, Gunkel A, Thumfart W (1997) Image-guided endoscopic ENT surgery. Eur Arch Otorhinolaryngol 254(7):343–346 Freysinger W, Gunkel A, Thumfart W (1997) Image-guided endoscopic ENT surgery. Eur Arch Otorhinolaryngol 254(7):343–346
14.
Zurück zum Zitat Kawamata T, Iseki H, Shibasaki T, Hori T (2002) Endoscopic augmented reality navigation system for endonasal transsphenoidal surgery to treat pituitary tumors: technical note. Neurosurgery 50(6):1393–1397PubMed Kawamata T, Iseki H, Shibasaki T, Hori T (2002) Endoscopic augmented reality navigation system for endonasal transsphenoidal surgery to treat pituitary tumors: technical note. Neurosurgery 50(6):1393–1397PubMed
15.
Zurück zum Zitat Stefansic JD, Herline AJ, Shyr Y, Chapman WC, Fitzpatrick JM, Dawant BM, Galloway RL (2000) Registration of physical space to laparoscopic image space for use in minimally invasive hepatic surgery. IEEE Trans Med Imaging 19(10):1012–1023PubMedCrossRef Stefansic JD, Herline AJ, Shyr Y, Chapman WC, Fitzpatrick JM, Dawant BM, Galloway RL (2000) Registration of physical space to laparoscopic image space for use in minimally invasive hepatic surgery. IEEE Trans Med Imaging 19(10):1012–1023PubMedCrossRef
16.
Zurück zum Zitat Lapeer R, Chen MS, Gonzalez G, Linney A, Alusi G (2008) Image-enhanced surgical navigation for endoscopic sinus surgery: evaluating calibration, registration, and tracking. Int J Med Robot Comput Assist Surg 4:32–45CrossRef Lapeer R, Chen MS, Gonzalez G, Linney A, Alusi G (2008) Image-enhanced surgical navigation for endoscopic sinus surgery: evaluating calibration, registration, and tracking. Int J Med Robot Comput Assist Surg 4:32–45CrossRef
17.
Zurück zum Zitat Liu WP, Mirota DJ, Uneria A, Otake Y, Hager G, Reh DD, Ishii M, Gallia GL, Siewerdsen JH (2012) A Clinical pilot study of a modular video-CT augmentation system for image-guided skull base surgery. In: Proceedings of the SPIE medical imaging, vol 8316 Liu WP, Mirota DJ, Uneria A, Otake Y, Hager G, Reh DD, Ishii M, Gallia GL, Siewerdsen JH (2012) A Clinical pilot study of a modular video-CT augmentation system for image-guided skull base surgery. In: Proceedings of the SPIE medical imaging, vol 8316
18.
Zurück zum Zitat Atuegwu NC, Galloway RL (2008) Volumetric characterization of the aurora magnetic tracker system for image-guided transorbital endoscopic procedures. Phys Med Biol 53(16):4355–4368PubMedCrossRef Atuegwu NC, Galloway RL (2008) Volumetric characterization of the aurora magnetic tracker system for image-guided transorbital endoscopic procedures. Phys Med Biol 53(16):4355–4368PubMedCrossRef
19.
Zurück zum Zitat Adbel-Aziz YI, Karara HM (1971) Direct linear transformation from comparator coordinates into object space coordinates in close range photogrammetry. In: Proceedings of the symposium on close range photogrammetry, pp 2–28 Adbel-Aziz YI, Karara HM (1971) Direct linear transformation from comparator coordinates into object space coordinates in close range photogrammetry. In: Proceedings of the symposium on close range photogrammetry, pp 2–28
21.
Zurück zum Zitat Zhang Z (1999) Flexible camera calibration by viewing a plane from unknown orientations. In: Proceedings of the 7th IEEE international conference on computer vision, pp 666–673 Zhang Z (1999) Flexible camera calibration by viewing a plane from unknown orientations. In: Proceedings of the 7th IEEE international conference on computer vision, pp 666–673
Metadaten
Titel
Transorbital target localization with augmented ophthalmologic surgical endoscopy
verfasst von
Michael P. DeLisi
Louise A. Mawn
Robert L. Galloway Jr.
Publikationsdatum
01.07.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 7/2015
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-014-1112-y

Weitere Artikel der Ausgabe 7/2015

International Journal of Computer Assisted Radiology and Surgery 7/2015 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.