Skip to main content
Erschienen in: BMC Medicine 1/2019

Open Access 01.12.2019 | Research article

Trends of blood pressure and heart rate in normal pregnancies: a systematic review and meta-analysis

verfasst von: Lise Loerup, Rebecca M. Pullon, Jacqueline Birks, Susannah Fleming, Lucy H. Mackillop, Stephen Gerry, Peter J. Watkinson

Erschienen in: BMC Medicine | Ausgabe 1/2019

Abstract

Background

Current reference ranges for blood pressure and heart rate throughout pregnancy have a poor evidence base.

Methods

This is a systematic review and meta-analysis. We included studies measuring blood pressure or heart rate from healthy pregnant women within defined gestational periods of 16 weeks or less. We analysed systolic blood pressure, diastolic blood pressure and heart rate by gestational age. We assessed effects of measurement year and method.

Results

We included 39 studies undertaken in 1967–2017, containing 124,349 systolic measurements from 36,239 women, 124,291 diastolic measurements from 36,181 women and 10,948 heart rate measurements from 8317 women. Mean (95% CI) systolic blood pressure was lowest at 10 weeks gestation, 110.4 (108.5, 112.3) mmHg, rising to 116.0 (113.6, 118.4) mmHg at 40 weeks, mean (95% CI) change 5.6 (4.0, 7.2) mmHg. Mean (95% CI) diastolic blood pressure was lowest at 21 weeks gestation, 65.9 (64.2, 67.7) mmHg; rising to 72.8 (71.0, 74.6) mmHg at 40 weeks, mean (95% CI) change 6.9 (6.2, 7.5) mmHg. Mean (95% CI) heart rate rose from 79.3 (75.5, 83.1) beats/min at 10 weeks to 86.9 (82.2, 91.6) beats/min at 40 weeks gestation, mean (95% CI) change 7.6 (1.8, 13.4) beats/min. Studies using manual measurement reported higher diastolic blood pressures than studies using automated measurement, mean (95 CI) difference 4.9 (0.8, 8.9) mmHg. Diastolic blood pressure increased by 0.26 (95% CI 0.10–0.43) mmHg/year. Including only higher-quality studies had little effect on findings, with heterogeneity remaining high (I2 statistic > 50%).

Conclusions

Significant gestational blood pressure and heart rate changes occur that should be taken into account when assessing pregnant women. Commonly taught substantial decreases in blood pressure mid-pregnancy were not seen and heart rate increases were lower than previously thought. Manual and automated blood pressure measurement cannot be used interchangeably. Increases in diastolic blood pressure over the last half-century and differences between published studies show contemporary data are required to define current normal ranges.

Study registration

Hinweise

Electronic supplementary material

The online version of this article (https://​doi.​org/​10.​1186/​s12916-019-1399-1) contains supplementary material, which is available to authorized users.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
AIC
Akaike Information Criterion
BIC
Bayesian Information Criterion
BMI
Body mass index
BP
Blood pressure
CI
Confidence interval
ECG
Electrocardiography
MEOWS
Modified Early Obstetric Warning Score
ML
Maximum likelihood
MOOSE
Meta-analysis Of Observational Studies in Epidemiology
PRISMA
Preferred Reporting Items for Systematic Reviews and Meta-Analyses
QUADAS-2
Quality Assessment of Diagnostic Accuracy Studies 2
REML
Restricted maximum likelihood estimation

Background

Heart rate and blood pressure are key vital signs for the assessment of pregnant women [1, 2]. Our understanding of the normal thresholds for these vital signs underpins their use. Many modern clinical guidelines do not reference the sources of their normal vital sign ranges [35]. Others refer to an obstetric physiology textbook, which references data from small individual studies published between 1970 and the mid-1990s [6]. Core textbooks commonly suggest a mid-pregnancy dip of around 5 mmHg for systolic and 10–15 mmHg for diastolic blood pressure along with a progressive rise in heart rate ranging from 10 to 20 beats/min [79]. Where referenced, these texts rely on the same physiology textbook [6] or small individual studies from over 30 years ago [10]. The changes in vital signs that occur in pregnancy are known to complicate the recognition of deterioration [11]. However, we could not identify a clinical guideline or Modified Early Obstetric Warning Score (MEOWS) [2] that took account of expected gestational changes in vital sign physiology. MEOWS use the perceived normal thresholds to determine whether a woman requires review. However, the thresholds used are based on clinical consensus [4, 12]. Small changes in thresholds make substantial differences to the ability of clinical scores to identify physiological deterioration [13, 14]. Evidence-based normal values that take into account changes during pregnancy are therefore required. We carried out a systematic review and meta-analysis to establish whether gestation-specific normal ranges for heart rate and systolic and diastolic blood pressure can be produced from available studies of participants that were “healthy” at recruitment. We planned to investigate the effects of year of measurement, method of measurement (for blood pressure) and parity on vital signs.

Methods

This systematic review follows the Meta-analysis Of Observational Studies in Epidemiology (MOOSE) [15] and Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) [16] guidelines (Additional file 1). We registered the review (PROSPERO: CRD42014009673) and published the protocol [17].
We included cross-sectional, case-control or longitudinal studies containing at least fifty participants and where measurements were taken by a healthcare professional.
We included studies containing blood pressure or heart rate measurements from pregnant women recruited as “healthy”. We defined “healthy” as women not known to have conditions likely to affect blood pressure or heart rate at the point of first measurement, according to inclusion and exclusion criteria described in Table 1. We included studies where participants recruited as healthy subsequently developed conditions potentially affecting blood pressure or heart rate. In studies where these participants’ data were presented separately, we extracted vital sign measurements for both groups. We excluded data where an intervention potentially affecting these vital signs was studied. We included baseline measurements prior to an intervention. We excluded data from subgroups selected at recruitment on the basis of characteristics or medical diagnoses (Additional file 2: List S1); we extracted data from control groups of “healthy” pregnant women in these studies. We excluded studies where the gestational age at which measurements were taken was not defined to 16 weeks or less.
Table 1
Inclusion and exclusion criteria
Inclusion criteria
Exclusion criteria
Cross-sectional, case-control or longitudinal study
Measurements from women with illnesses likely to affect the cardiac or respiratory systems
Minimum of 50 patients
Measurements from women who were recruited because they were considered to be at high-risk of developing a pregnancy complication
Age 14 years or older
Measurements from women known to be taking medication which could affect the measurements
Objective measurement* of heart rate and/or blood pressure
Measurements from women where the reported gestational age at the point of measurement was not defined in terms of days or weeks of gestation
Measurements taken during the antenatal period, up to the start of the intrapartum period
Measurements from women where the time window in which the measurement was taken was not defined to within 16 weeks
Raw data or average measure reported and possible to extract within minimum accuracy
Measurements from self-monitoring or other measurements not taken by a healthcare professional
 
Measurements from women with less than 10% singleton pregnancies
 
For women known to undergo fertility procedures, any measurements taken prior to a positive pregnancy test
 
Any of the following measurements (without valid baseline):
• Measurements taken using ambulatory technologies
• Measurements taken using invasive technologies
• Measurements taken during anaesthesia
• Measurements taken during sleep
• Measurements taken during exercise
• Measurements taken at heights greater than 1000 m above sea level
*An overview of acceptable measurement techniques has been described previously [17]
Defined as progressive cervical dilatation with regular contractions
List of characteristics or diagnoses leading to exclusion are shown in Additional file 2: List S1
We set out to include measurements of all six vital signs recommended for clinical assessment (systolic blood pressure, diastolic blood pressure, heart rate, oxygen saturation, respiratory rate and/or temperature), made antepartum, intrapartum or postpartum [17]. We have restricted this report to blood pressure and heart rate data measured in the antepartum period, as we found little data for other vital signs or time periods.

Search strategy

With a trained librarian, we searched MEDLINE, Embase and CINAHL, from inception until February 2018. We also searched reference lists and contacted field experts. Where required data were not presented or were presented in a form we could not extract, we contacted the original authors by e-mail. We used both MeSH and free-text terms. We did not restrict the year or language of publication. The complete search strategy has been described previously [17]. Additional file 2: Table S1 details the MEDLINE search strategy.
Two reviewers (LL and RP) independently screened retrieved titles and abstracts to exclude studies that clearly fell outside the scope of the review, such as foetal or animal studies. Two reviewers (PW and LM) independently screened the remaining studies by title, then by abstract and finally by full text against the inclusion and exclusion criteria (Table 1). Where reviewers disagreed, the study proceeded to the next screening stage.

Data extraction

Two reviewers (LL and RP) independently extracted study data onto a piloted spreadsheet (Microsoft Excel). Disagreements were automatically highlighted and resolved by recourse to the original papers or in consultation with a medical statistician (JB), intensive care specialist (PW) or obstetric physician (LM), as required.
For each study, we extracted information about the study (year of data collection and publication, study setting, country of study, data collection schedule), measurements (method, subject position, details of measurement device) and participants (age, weight, body mass index (BMI), ethnicity, reason for measurements, parity, number of gestations, pregnancy dating method). For each period of pregnancy defined in a paper, we extracted information about the sample size and minimum and maximum gestational age, together with reported summary statistics for blood pressure and heart rate. We used Engauge Digitizer, https://​sourceforge.​net/​projects/​digitizer/​works (open source software) to extract data from graphs if the underlying data were not presented and we could not obtain it from the authors.

Assessment of bias

Two reviewers (LL and RP) independently undertook quality assessment in line with QUADAS (Quality Assessment of Diagnostic Accuracy Studies)-2 [18], adapted from the methodology of Ioannou et al. [19] following pre-determined rules (Additional file 2: Table S2). We assessed studies over two domains: study design and reporting methods. We scored statistical methods within these two domains, taking account of differing study designs. Each methodological criterion was scored as either “high” or “low” risk of bias. For each of the two domains, the overall quality score for each study was defined as the percentage of “low risk of bias” marks over the total number of criteria. We assessed the effects of only including studies scoring 50% or more on mean estimates of heart rate and blood pressure and on heterogeneity between studies.

Summary measures

Principal summary statistics were mean and standard deviation for each measure of heart rate and blood pressure, along with sample size. Where mean and standard deviation for blood pressure and heart rate were not reported, we approximated these assuming a normal distribution (with no skewness), in line with previous descriptions of vital sign measurement distributions [20]. Where multiple measurements were reported on the same day for the same participants (e.g. blood pressure measured in the sitting and lying positions), we selected a single data point using pre-specified rules [17]. We assigned the development status of a study country using the Human Development Index (2015) [21].
Where the gestational age associated with each data point was reported as a mean or median gestational age, we used this for the analysis. Where the gestational age associated with each data point was reported as a range, we used the mid-point of the range. Gestational age measured using ultrasound measurement of the foetal crown-rump length before 14 weeks gestation was our preferred assessment method [22].
Where the sample size associated with each data point was reported, we used this for the analysis. For studies where the sample size was reported only at baseline, we took the sample size associated with each data point to be the baseline sample size, assuming no dropouts or loss-to-follow-up.
Where characteristics of women (weight, BMI, age, parity) were reported at multiple time points (e.g. pre-pregnancy, at recruitment and/or at delivery), we used the value closest to recruitment. Where the mean values of the characteristics of the sample of women associated with each data point were reported, we used this for analysis. For studies where the characteristics of women were only reported for the entire sample of women recruited, and not for the sample at each time point, we used entire sample values, assuming no dropouts or loss to follow-up. Where only median values were reported, we used these instead of the mean values, assuming normal distributions of characteristics (with no skewness).
The study year was taken to be the last year of recruitment to the study or the year of publication where this was not reported.

Synthesis of results

To analyse trajectories of changes in blood pressure and heart rate, we adapted the method for meta-analysis of longitudinal studies proposed by Ishak et al. [23, 24] Ishak conducted a meta-analysis of longitudinal studies reporting data at a series of fixed time points, using study summary statistics. Linear mixed effects models were used to take account of correlations in longitudinal data. We adapted Ishak’s general multivariate model to conduct a meta-analysis of studies which report data at different time points, whilst still accounting for correlations between data points within studies and between studies (our “longitudinal model”). The time points in our analysis are the different values of gestational age. All data points from an individual study were included. We used a random coefficients model that allows for an arithmetic description of the relationship between the measurement of interest and gestational age [25]. The models were built up based on polynomials of gestational age by adding higher order polynomials, first as fixed effects, and then as random coefficients. Decisions on which terms to include were based on AIC and BIC (Akaike and Bayesian Information Criterion)—measures of assessing model fit whilst accounting for the number of parameters [26, 27]. To assess the additional benefit of higher order fixed effects terms, we fitted models based on maximum likelihood (ML) estimation; whereas to assess the benefit of higher-order random effect terms, and to fit the final model, we undertook restricted maximum likelihood estimation (REML). Each observation was weighted according to the study reported standard error. To account for the correlation of observations within a study, a spatial power covariance structure was used, which allows for the irregular nature of time between measurements [28].
We undertook pre-specified secondary analyses to investigate the effects of method of measurement (manual vs. automated), year of data collection and parity on systolic and diastolic blood pressure. We added these covariates to the model as fixed effects. We added method of measurement and year of measurement simultaneously as we expected them to be related. To assess the effect of parity, where possible, we separated data into nulliparous and multiparous groups. Otherwise, we entered parity into the model as the proportion of multiparous mothers. We did not undertake secondary analyses of heart rate, as the limited study numbers would have resulted in imprecise results.
Additionally, we pooled data for each trimester from each included study in a random effects analysis to generate Forest plots for each vital sign. Trimesters were defined as trimester 1 from 0+ 0 to 12+ 6 weeks; trimester 2 from 13+ 0 to 25+ 6 weeks; trimester 3 from 26+ 0 to 36+ 6 weeks and full term from 37+ 0 weeks to delivery [29]. Where data were reported for subgroups within a single study, for example for nulliparous and multiparous women, a weighted mean and standard error of the mean were calculated. Where more than two data points for a single trimester within a study were reported, the same women would be included in both data points, so the mean of the data points was calculated. The standard error of the mean was calculated assuming a correlation between measurements on the same patient of 0.7. This was considered reasonable considering how close in time the measurements were. The weighted mean of the gestational age for the data points was calculated.
We estimated the pooled weighted mean and 95% confidence intervals where the weight of an individual study was inversely proportional to the sum of the variance (SE2) of the study mean and the between-study variance. To estimate the spread of vital sign data in an individual study setting, we computed 95% prediction intervals from the random effects analysis, according to the methodology presented by Riley et al. [30] We determined heterogeneity using the I2 statistic (range 0–100%).
We performed a pre-specified sensitivity analysis excluding outlying studies (with means lying outside of the predictive interval). We also performed an additional sensitivity analysis excluding studies scoring less than 50% on quality assessment.
As the studies included in the review did not have a comparative design, we could not assess publication bias. However, selective reporting was assessed as part of the quality assessment.
Statistical analyses were undertaken using StataCorp. 2015 (Stata Statistical Software: Release 14. College Station, TX: StataCorp LP) or SAS software (Version 9.3, SAS Institute Inc. SAS).

Results

Database screening identified 1897 publications. We identified a further 14 publications from reference lists or expert knowledge. We included 39 studies from 20 countries meeting our pre-specified criteria, Fig. 1. Detailed reasons for exclusion are shown in Additional file 2: Table S3.
The included studies are summarised in Additional file 2: Table S4. We extracted blood pressure data from 34 studies. We extracted heart rate data from 13 studies. Studies came from 20 different countries, 17 high-development countries and three middle- or low-development countries. One (Russian) study was not reported in English [31].
We included 394 summary measurements of blood pressure, representing 124,349 systolic measurements from 36,239 women and 124,291 diastolic measurements from 36,181 women. The 23 longitudinal studies reported measurements of blood pressure from 33 separate groups of women [3254]. Longitudinal studies varied in the number of time points at which a group had blood pressure measured (median 4 time points, range 2 to 35). A further 11 studies reported cross-sectional measurements [31, 5564]. Two of these studies reported multiple cross-sectional measurements [56, 61]. The remaining studies reported measurements at a single time. A manual sphygmomanometer was used in fifteen studies [34, 35, 3739, 41, 44, 45, 47, 49, 53, 57, 58, 62, 64]. An automated blood pressure monitor was used in thirteen studies [32, 33, 42, 43, 48, 5052, 5456, 59, 61]. Six studies did not report the measurement methodology [31, 36, 40, 46, 60, 63].
We included 34 summary measurements of heart rate, representing 10,948 heart rate measurements from 8317 women. The five longitudinal studies reported measurements from seven separate groups of women [32, 42, 48, 65, 66]. Summary measurements were reported at between 3 and 8 (median 4) time points per group. A further eight studies reported cross-sectional measurements of heart rate at a single time point [31, 57, 59, 63, 64, 6769]. The method of heart rate measurement was reported as electrocardiography (ECG; 5 studies, 8 time points) [57, 64, 6668], echocardiography (echo; 1 study, 2 time points) [69], finger arterial pressure sensor (1 study, 4 time points) [48], radioulnar pulse wave monitoring (1 study, 8 time points) [65], reading from an automated blood pressure (BP) monitor (2 studies, 4 time points) [42, 59] or not specified (3 studies, 16 time points) [31, 32, 63].
Quality assessment scores ranged from 5.6 to 84.2% (median 44.4%, where 100% is a good score). Additional file 2: Figure S1 summarises the score per assessment criterion. Individual paper scores are shown in Additional file 2: Table S4. Common reasons for scoring poorly included not sufficiently defining the population under study (28 studies), not defining gestational age using ultrasound measurement of crown-rump length before 14 weeks (26 studies) and not describing/using measurement devices ratified for use in pregnancy (30 studies). Of the 13 studies that used automated methods of blood pressure measurement, three stated that they used machines validated for use in pregnancy [42, 48, 59]. Five studies reported that the measurement device was calibrated prior to the study taking place (all manual sphygmomanometer methods) [37, 39, 44, 62, 64]. The method of blood pressure measurement was not specified in six studies [31, 35, 36, 40, 46, 69]. Use of an appropriately sized BP cuff was reported in 13 studies [33, 37, 38, 4245, 47, 49, 54, 58, 61, 62].
Both systolic and diastolic blood pressure changed significantly across pregnancy (for combined manual and automatic readings) when modelled using our longitudinal model (Fig. 2). Systolic blood pressure was lowest at 10 weeks gestation, mean (95% confidence intervals, CI) 110.4 (108.5, 112.3) mmHg, rising to 116.0 (113.6, 118.4) mmHg at 40 weeks gestation; a change of 5.6 (95% CI 4.0, 7.2) mmHg from 10 to 40 weeks (p < 0.001). Mean (95% CI) diastolic blood pressure was 67.1 (65.4, 68.7) mmHg at 10 weeks gestation. Mean (95% CI) diastolic blood pressure was lowest at 21 weeks 65.9 (64.2, 67.7) mmHg, rising to 72.8 (71.0, 74.6) mmHg at 40 weeks; a change of 6.9 (95% CI 6.2, 7.5) mmHg from 21 to 40 weeks (p < 0.001). Mean (95% CI) heart rate rose from 79.3 (75.5, 83.1) beats/min at 10 weeks to 86.9 (82.2, 91.6) beats/min at 40 weeks; a change of 7.6 (1.8, 13.4) beats/min from 10 to 40 weeks (p = 0.014), Fig. 3. Though all longitudinal studies showed heart rate to increase across pregnancy, three relatively small studies showed a small drop in heart rate at the end of pregnancy [32, 48, 65].
Forest plots of systolic, diastolic and heart rate data (one plot per trimester) are shown (Additional file 2: Figure S2). Significant heterogeneity was present for all measures in all trimesters. Blood pressure and heart rate mean trimester estimates were similar whether estimated using our longitudinal model or random effects meta-analyses (Additional file 2: Table S5).

Subgroup analyses

Studies that used a manual measurement reported higher mean diastolic blood pressures than studies using an automated technique, difference (95% CI) in mean intercept of 4.9 (0.8, 8.9) mmHg (p = 0.020). Mean manual systolic blood pressure measurements did not differ from those in studies that used an automated measurement, difference (95% CI) in mean intercept of 2.8 (− 2.3, 7.9), p = 0.274 (Additional file 2: Figure S3).
Studies of automated measures commenced in 2002 becoming more common over time. We therefore analysed the effect of time on blood pressure for manual measurements only. Each year from 1969 to 2017, diastolic blood pressure increased by 0.26 (95% CI 0.10–0.43) mmHg, p = 0.003. Systolic blood pressure rose by 0.12 (95% CI − 0.09, 0.33) mmHg per annum, but the rise was not statistically significant (p = 0.256). Differences were not affected by gestational age.
Data was available from studies to allow us to assess the effects of parity on systolic and diastolic blood pressure. Nulliparous and parous women did not differ in either systolic blood pressure, mean (95% CI) difference − 0.32 (− 7.7, 7.1) mmHg, p = 0.927, or diastolic blood pressure, mean (95% CI) difference 1.30 (− 5.2, 7.8) mmHg, p = 0.671, (Additional file 2: Figure S4).
We could not adjust for maternal characteristics, such as age and weight, as such data were often missing or reported using different summary measures at different gestational ages.

Sensitivity analyses

Excluding outlying studies (with means lying outside of the predictive interval) reduced the number of studies by a maximum of five studies for studies of blood pressure. As all the outlying studies were “high outliers”, the mean estimates of systolic and diastolic blood pressure were decreased by about 1 mmHg, but the pattern across gestational ages remained the same (Additional file 2: Table S5b). This analysis also removed the one relatively small study where blood pressure appeared to decrease toward the end of pregnancy [49]. No studies of heart rate had means outlying the predictive interval.
Analysing only studies with a quality score above 50% reduced the number of studies for analysis from 34 to 12 for blood pressure and from 13 to 7 for heart rate. We found little change in mean estimates of blood pressure (though systolic blood pressure fell marginally in trimester 2), or heart rate, and measures of heterogeneity remained above 95% (Additional file 2: Table S5c).

Discussion

Our study synthesises the available evidence to describe changes in blood pressure and heart rate during pregnancy. As far as we are aware, this has not previously been done. We show that systolic blood pressure rises by 5.6 (95% CI 4.0, 7.2) mmHg between 10 and 40 weeks gestation (with a possible slight drop of around 1 mmHg in trimester 2 when only higher-quality studies were included). Unlike systolic blood pressure, diastolic blood pressure is lowest at 21 weeks gestation, rising by 6.9 (CI 6.2, 7.5) mmHg by 40 weeks. Mean diastolic blood pressures were on average 4.9 (0.8, 8.9) mmHg lower when measured using automated techniques than when using manual methods. There is no difference in either systolic or diastolic blood pressure between nulliparous and parous women. Over 48 years, average diastolic blood pressures rose by 0.26 (95% CI 0.10–0.43) mmHg per year. Heart rate rises by 7.6 (95% CI 1.8–13.4) beats per minute through pregnancy.
Our synthesis brings together more blood pressure and heart rate data from more pregnant women than has previously been done. This increases our understanding of the trends that occur during pregnancy. It also shows the large between-study heterogeneity, emphasising the importance of not simply taking results from a single study. Consequently, our mean estimates were imprecise (95% CI width was around 5 mmHg for blood pressure and 9 beats per minute for heart rate). We did not meta-analyse other centile estimates for blood pressure and heart rate (for example 5th or 95th). As most studies did not report centiles of the distributions, approximations would need to be made, using assumptions about data distributions. The precision would likely have been lower than at the means, resulting in wide confidence intervals, with little clinical value. Such an analysis would have been imprecise and potentially misleading.
As with many meta-analyses, combining these data is complex. Included studies were of mixed methodological quality. We identified three aspects of particular concern: Firstly, a lack of accuracy in measuring and reporting of gestational age. Secondly, only a minority of studies reported using automated blood pressure measurement devices ratified for use in pregnancy. This means that we cannot ascertain whether the differences between blood pressures measured with manual sphygmomanometers and automatic methods would have been present if automatic methods ratified for use in pregnancy had been used. Thirdly, many studies insufficiently defined the population studied. These methodological weaknesses may have contributed to the range of possible mean blood pressures for any gestational age in our analyses. They may also partly account for the heterogeneity we found. Sensitivity analyses to account for quality and outlying studies had little effect in reducing heterogeneity. Further exploration of the sources of the heterogeneity was prevented by a lack of consistent reporting of the additional variables that would be required. The substantial between-study difference in blood pressure and heart rates at all gestational ages creates uncertainty around our mean values, but is less of a problem when analysing trends across pregnancy and time and when considering differences between measurement methods.
We investigated the effect of methodological quality in two ways, by undertaking a pre-specified analysis excluding outlying studies and by excluding studies scoring less than 50% on quality assessment. As all the outlying studies were “high outliers”, the mean estimates of systolic and diastolic blood pressure were decreased by about 1 mmHg, but the pattern across gestational ages remained the same (Additional file 2: Table S5b). Excluding studies with a quality assessment score of less than 50% had little change in mean estimates of blood pressure (though systolic blood pressure fell marginally in trimester 2), or heart rate (Additional file 2: Table S5c).
We planned to estimate blood pressure and heart rate trends for normal pregnancies, accepting that definitions of normal pregnancy vary. Where participants subsequently developed complications, we included their readings. As a consequence, we kept in women who developed pre-eclampsia or gestational hypertension whilst in the original study. As most studies did not present data excluding these participants, we could not derive mean values for populations who remained “normal” at delivery.
We combined longitudinal and cross-sectional study data. Blood pressures from longitudinal studies are not independent, in contrast to cross-sectional studies where blood pressures from different women at different points in pregnancy are independent. To avoid underestimating the precision of our estimates by ignoring the longitudinal correlations, we used the random time-effects method proposed by Ishak et al. for the meta-analysis of summary data. This model addresses the dependencies between longitudinal data points through the inclusion of random time effects between studies. Additionally, the random time-effects method accounts for the exact measurement time points of the included studies. We could not include within-study correlations as none of the included studies reported these. Maternal age and weight were often not presented, and where presented, the gestational age at which they were reported was inconsistent, preventing exploration of their effect on the temporal increase in diastolic blood pressure. The included studies came from a wide range of countries (Additional file 2: Table S4), including a wide range of ethnicities. However, our results may not be generalisable across all ethnic groups. Given the large number of included patients, it appears unlikely that our pre-specified plan to exclude studies with less than 50 participants significantly affected our findings.
Our findings remain compatible with the known increase in myocardial alpha receptors (resulting in increased heart rate), increased plasma volume and decreased systemic vascular resistance that occur in pregnancy [9]. However, in comparison to the 5-mmHg mid-pregnancy drop for systolic blood pressure and 10–15-mmHg drop for diastolic blood pressure previously suggested [79], the changes we found were small (with little change in systolic blood pressure and a 2–3-mmHg drop in diastolic blood pressure). It is possible that blood pressure drops in pregnancy before most of the included studies took measurements [42, 70]. However, our lowest mean systolic and diastolic blood pressures were similar to those reported for normal young, non-pregnant female populations [71] and a study used as evidence of an early drop is included in our model [42]. Heart rate rose by 7.6 (95% CI 1.8, 13.4) beats/min rather than the 10–20 beats/min core texts commonly suggest [79]. Taken with other work showing smaller changes than previously though [38, 43, 51], these findings should alter current teaching, allowing more reliable assessment of pregnant women. Previous work in adult early warning scores shows that relatively small changes in thresholds have large changes in the ability of a score to detect deterioration [13, 14]. Published maternal early warning scores commonly have ranges for alerting thresholds of 10 mmHg for blood pressure and 10 beats per minute for heart rate [11, 72]. Our study shows that the normal changes in pregnancy account for over half these ranges. It seems likely that detection of acute deterioration in pregnancy could be improved by taking account of gestation. Equally, recognition of women at risk of hypertensive disorders of pregnancy may be improved by taking account of these patterns [73]. Prior to our study, possibly the best evidence for blood pressure patterns in pregnancy came from a single-centre study undertaken over 20 years ago [38]. Data from this work contributes to our study. The evidence for patterns in heart rate was even more limited. Blood pressure differences between nulliparous and parous women were small, in line with previous findings [38], and did not reach statistical significance.
Our finding of increasing diastolic blood pressure over the 48 years in which these studies have been undertaken is previously unknown. We did not find a study with data over a sufficient period to add to this finding. Increasing average maternal age [7476] and/or weight [38, 77] may provide part of the explanation. These changes contribute to the uncertainty of our overall estimates.
The mean diastolic blood pressure was lower when measured using automated methods than when measured manually. Previously, several automated monitors have been found to underestimate diastolic blood pressure in pre-eclampsia [7880]. Although we included women who subsequently developed pre-eclampsia, their contribution to our overall effect will be small as they form a small proportion of the total cohort and contributed readings prior to developing pre-eclampsia. Importantly, the mean difference is just lower than the minimum validation requirement for automated devices, suggesting that many of the devices used would not achieve this criteria [81]. The difference between manual and automated measurement could commonly change the weight applied to a blood pressure measurement in early warning scores. As many of the automated techniques were not known to be certified for use in pregnancy and several automated devices have been validated for use in pregnancy [8285], it may be that the problem could be resolved by only using certified devices. Alternatively, the difference may in part be explained by use of the fourth rather than fifth phase to determine diastolic pressure manually.
Future studies should define gestational age precisely, recruit well-defined populations and for blood pressure only use devices ratified for use in pregnancy. For blood pressure, the differences between automated and manual methods across pregnancy need exploring with automated methods approved for use in pregnancy. The changes in diastolic blood pressure across five decades suggest normal ranges should be regularly revisited. Finally, the impact of using gestation-specific centiles to allow earlier detection of the unwell mother requires investigation.

Conclusions

Gestational changes in blood pressure and heart rate should be taken into account when assessing pregnant women, but heterogeneity between studies prevents the production of gestation-specific evidence-based normal ranges. Assessment of blood pressure need not differ between nulliparous and parous women. Automatically measured diastolic blood pressures are lower than those measured manually. A consistent measurement system should be used through pregnancy. Decreases in blood pressure mid-pregnancy and increases in heart rate through pregnancy are smaller than previously thought. Taken with other work, these findings should contribute to more reliable assessment of pregnant women. Increases in diastolic blood pressures recorded over the last half century show contemporary data is required to define normal ranges for current practice.

Acknowledgements

We wish to thank Inessa Walker for her help with translation (Russian) and Tatjana Petrinic for her help designing and undertaking the searches.
Not applicable.
Not applicable.

Competing interests

PW, JB, SM and SF report significant grants from the National Institute of Health Research (NIHR), UK. PW, JB, SM, LM and SF report significant grants from the NIHR Biomedical Research Centre, Oxford, during the conduct of the study. PW and LM report modest grants and personal fees from Sensyne Health, outside the submitted work. LL and RP report significant grants from the RCUK Digital Economy Programme. LL reports significant grants from the Clarendon Fund. LL now works for the Boston Consulting Group, whose clients include medical technology and health analytics companies. PW and LM work part-time for Sensyne Health. PW and LM hold shares in Sensyne Health.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Swanton RDJ, Al-Rawi S, Wee MYK. A national survey of obstetric early warning systems in the United Kingdom. Int J Obstet Anesth. 2009;18:253–7.PubMedCrossRef Swanton RDJ, Al-Rawi S, Wee MYK. A national survey of obstetric early warning systems in the United Kingdom. Int J Obstet Anesth. 2009;18:253–7.PubMedCrossRef
2.
Zurück zum Zitat Smith GB, Isaacs R, Andrews L, Wee MY, van Teijlingen E, Bick DE, et al. Vital signs and other observations used to detect deterioration in pregnant women: an analysis of vital sign charts in consultant-led UK maternity units. Int J Obstet Anesth. 2017;30:44–51.PubMedCrossRef Smith GB, Isaacs R, Andrews L, Wee MY, van Teijlingen E, Bick DE, et al. Vital signs and other observations used to detect deterioration in pregnant women: an analysis of vital sign charts in consultant-led UK maternity units. Int J Obstet Anesth. 2017;30:44–51.PubMedCrossRef
3.
Zurück zum Zitat Paterson-Brown S, Howell C. Managing Obstetric Emergencies and Trauma (MOET): Course manual. Cambridge: Cambridge University Press; 2014. Paterson-Brown S, Howell C. Managing Obstetric Emergencies and Trauma (MOET): Course manual. Cambridge: Cambridge University Press; 2014.
4.
Zurück zum Zitat Isaacs RA, Wee MYK, Bick DE, Beake S, Sheppard ZA, Thomas S, et al. A national survey of obstetric early warning systems in the United Kingdom: five years on. Anaesthesia. 2014;69(7):687–92.PubMedCrossRef Isaacs RA, Wee MYK, Bick DE, Beake S, Sheppard ZA, Thomas S, et al. A national survey of obstetric early warning systems in the United Kingdom: five years on. Anaesthesia. 2014;69(7):687–92.PubMedCrossRef
5.
Zurück zum Zitat Winter C, Crofts J, Laxton C, Barnfield S, Draycott T, editors. PRactical Obstetric Multi-Professional Training (PROMPT): course manual. Cambridge: Cambridge University Press; 2012. Winter C, Crofts J, Laxton C, Barnfield S, Draycott T, editors. PRactical Obstetric Multi-Professional Training (PROMPT): course manual. Cambridge: Cambridge University Press; 2012.
6.
Zurück zum Zitat Chamberlain G, Pipkin F. Clinical physiology in obstetrics. 3rd ed. Oxford: Blackwell Science; 1998. Chamberlain G, Pipkin F. Clinical physiology in obstetrics. 3rd ed. Oxford: Blackwell Science; 1998.
7.
Zurück zum Zitat Khalil A. Your essential revision guide: MRCOG part one : the official companion to the Royal College of Obstetricians and Gynaecologists revision course, Chapter 31. Fiander A, Thilaganathan B, editors. London: Royal College of Obstetricians and Gynaecologists (Great Britain). Cambridge University Press; 2010. 538. Khalil A. Your essential revision guide: MRCOG part one : the official companion to the Royal College of Obstetricians and Gynaecologists revision course, Chapter 31. Fiander A, Thilaganathan B, editors. London: Royal College of Obstetricians and Gynaecologists (Great Britain). Cambridge University Press; 2010. 538.
8.
Zurück zum Zitat O’Donoghue K. Obstetrics by ten teachers, chapter 3. 19th ed. Baker PN, Kenny LC, editors. London: CRC press; 2011. 436 p. O’Donoghue K. Obstetrics by ten teachers, chapter 3. 19th ed. Baker PN, Kenny LC, editors. London: CRC press; 2011. 436 p.
9.
Zurück zum Zitat Blackburn ST. Maternal, fetal, & neonatal physiology: a clinical perspective, chapter 9. 4th ed. Philadelphia: Elsevier Saunders; 2013. 719 p. Blackburn ST. Maternal, fetal, & neonatal physiology: a clinical perspective, chapter 9. 4th ed. Philadelphia: Elsevier Saunders; 2013. 719 p.
10.
Zurück zum Zitat Wilson M, Morganti AA, Zervoudakis I, Letcher RL, Romney BM, Von Oeyon P, et al. Blood pressure, the renin-aldosterone system and sex steroids throughout normal pregnancy. Am J Med. 1980;68(1):97–104.PubMedCrossRef Wilson M, Morganti AA, Zervoudakis I, Letcher RL, Romney BM, Von Oeyon P, et al. Blood pressure, the renin-aldosterone system and sex steroids throughout normal pregnancy. Am J Med. 1980;68(1):97–104.PubMedCrossRef
11.
Zurück zum Zitat CMACE. Saving Mothers’ Lives: Reviewing maternal deaths to make motherhood safer: 2006–2008. BJOG. 2011;118:1–203. CMACE. Saving Mothers’ Lives: Reviewing maternal deaths to make motherhood safer: 2006–2008. BJOG. 2011;118:1–203.
12.
13.
Zurück zum Zitat Smith GB, Prytherch DR, Schmidt PE, Featherstone PI. Review and performance evaluation of aggregate weighted “track and trigger” systems. Resuscitation. 2008;77:170–9.PubMedCrossRef Smith GB, Prytherch DR, Schmidt PE, Featherstone PI. Review and performance evaluation of aggregate weighted “track and trigger” systems. Resuscitation. 2008;77:170–9.PubMedCrossRef
14.
Zurück zum Zitat Smith GB, Prytherch DR, Schmidt PE, Featherstone PI, Higgins B. A review, and performance evaluation, of single-parameter “track and trigger” systems. Resuscitation. 2008;79(1):11–21.PubMedCrossRef Smith GB, Prytherch DR, Schmidt PE, Featherstone PI, Higgins B. A review, and performance evaluation, of single-parameter “track and trigger” systems. Resuscitation. 2008;79(1):11–21.PubMedCrossRef
15.
Zurück zum Zitat Stroup DF, Berlin JA, Morton SC, Olkin I, Williamson GD, Rennie D, et al. Meta-analysis of observational studies in epidemiology: a proposal for reporting. Meta-analysis of observational studies in epidemiology (MOOSE) group. JAMA. 2000;283(15):2008–12.PubMedCrossRef Stroup DF, Berlin JA, Morton SC, Olkin I, Williamson GD, Rennie D, et al. Meta-analysis of observational studies in epidemiology: a proposal for reporting. Meta-analysis of observational studies in epidemiology (MOOSE) group. JAMA. 2000;283(15):2008–12.PubMedCrossRef
16.
Zurück zum Zitat Moher D, Liberati A, Tetzlaff J, Altman DG, PRISMA Group. Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement. PLoS Med. 2009;6(7):e1000097.PubMedPubMedCentralCrossRef Moher D, Liberati A, Tetzlaff J, Altman DG, PRISMA Group. Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement. PLoS Med. 2009;6(7):e1000097.PubMedPubMedCentralCrossRef
17.
Zurück zum Zitat Loerup L, Pullon RMRM, Birks J, Fleming S, Mackillop LHLH, Watkinson PJPJ. Trends of vital signs with gestational age in normal pregnancies: a systematic review protocol. BMJ Open. 2016;6(1):e008769.PubMedPubMedCentralCrossRef Loerup L, Pullon RMRM, Birks J, Fleming S, Mackillop LHLH, Watkinson PJPJ. Trends of vital signs with gestational age in normal pregnancies: a systematic review protocol. BMJ Open. 2016;6(1):e008769.PubMedPubMedCentralCrossRef
18.
Zurück zum Zitat Whiting PF, Rutjes AWS, Westwood ME, Mallett S, Deeks JJ, Reitsma JB, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155(8):529–36.PubMedCrossRef Whiting PF, Rutjes AWS, Westwood ME, Mallett S, Deeks JJ, Reitsma JB, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155(8):529–36.PubMedCrossRef
19.
Zurück zum Zitat Ioannou C, Talbot K, Ohuma E, Sarris I, Villar J, Conde-Agudelo A, et al. Systematic review of methodology used in ultrasound studies aimed at creating charts of fetal size. BJOG. 2012;119(12):1425–39.PubMedCrossRef Ioannou C, Talbot K, Ohuma E, Sarris I, Villar J, Conde-Agudelo A, et al. Systematic review of methodology used in ultrasound studies aimed at creating charts of fetal size. BJOG. 2012;119(12):1425–39.PubMedCrossRef
20.
Zurück zum Zitat Tarassenko L, Clifton DADA, Pinsky MRMR, Hravnak MTMT, Woods JRJR, Watkinson PJPJ. Centile-based early warning scores derived from statistical distributions of vital signs. Resuscitation. 2011;82(8):1013–8.PubMedCrossRef Tarassenko L, Clifton DADA, Pinsky MRMR, Hravnak MTMT, Woods JRJR, Watkinson PJPJ. Centile-based early warning scores derived from statistical distributions of vital signs. Resuscitation. 2011;82(8):1013–8.PubMedCrossRef
21.
Zurück zum Zitat United Nations Development Programme. Human Development Report 2015. New York: Work for Human Development; 2015. United Nations Development Programme. Human Development Report 2015. New York: Work for Human Development; 2015.
22.
Zurück zum Zitat Butt K, Lim K, Bly S, Cargill Y, Davies G, Denis N, et al. Determination of gestational age by ultrasound. J Obstet Gynaecol Canada. 2014;36(2):171–81.CrossRef Butt K, Lim K, Bly S, Cargill Y, Davies G, Denis N, et al. Determination of gestational age by ultrasound. J Obstet Gynaecol Canada. 2014;36(2):171–81.CrossRef
24.
Zurück zum Zitat Ishak KJ, Platt RW, Joseph L, Hanley JA, Caro JJ. Meta-analysis of longitudinal studies. Clin Trials. 2007;4(5):525–39.PubMedCrossRef Ishak KJ, Platt RW, Joseph L, Hanley JA, Caro JJ. Meta-analysis of longitudinal studies. Clin Trials. 2007;4(5):525–39.PubMedCrossRef
25.
Zurück zum Zitat Brown H, Prescott R, editors. Applied mixed models in medicine, 3rd Edition. Chichester: Wiley; 2014. Brown H, Prescott R, editors. Applied mixed models in medicine, 3rd Edition. Chichester: Wiley; 2014.
26.
Zurück zum Zitat Yao YC. Estimating the number of change-points via Schwarz’ criterion. Stat Probab Lett. 1988;6(3):181–9.CrossRef Yao YC. Estimating the number of change-points via Schwarz’ criterion. Stat Probab Lett. 1988;6(3):181–9.CrossRef
27.
Zurück zum Zitat Akaike H. A new look at the statistical model identification. IEEE Trans Autom Control. 1974;19(6):716–23.CrossRef Akaike H. A new look at the statistical model identification. IEEE Trans Autom Control. 1974;19(6):716–23.CrossRef
28.
Zurück zum Zitat Moser EB. Repeated measures modeling with PROC MIXED. SAS Users Gr Int. 2004;29(1):1–19. Moser EB. Repeated measures modeling with PROC MIXED. SAS Users Gr Int. 2004;29(1):1–19.
30.
Zurück zum Zitat Riley RD, Higgins JPT, Deeks JJ. Interpretation of random effects meta-analyses. BMJ. 2011;342(7804):d549.PubMedCrossRef Riley RD, Higgins JPT, Deeks JJ. Interpretation of random effects meta-analyses. BMJ. 2011;342(7804):d549.PubMedCrossRef
31.
Zurück zum Zitat Demidov VN. Comparative evaluation of the changes in the cardiac activity and hemodynamics of healthy women at the end of pregnancy while lying on their sides and on their backs. Vopr Okhr Materin Det. 1978;23(3):71–5.PubMed Demidov VN. Comparative evaluation of the changes in the cardiac activity and hemodynamics of healthy women at the end of pregnancy while lying on their sides and on their backs. Vopr Okhr Materin Det. 1978;23(3):71–5.PubMed
32.
Zurück zum Zitat Andreas M, Kuessel L, Kastl SP, Wirth S, Gruber K, Rhomberg F. Bioimpedance cardiography in pregnancy: a longitudinal cohort study on hemodynamic pattern and outcome. BMC Pregnancy Childbirth. 2016;16(1):128.PubMedPubMedCentralCrossRef Andreas M, Kuessel L, Kastl SP, Wirth S, Gruber K, Rhomberg F. Bioimpedance cardiography in pregnancy: a longitudinal cohort study on hemodynamic pattern and outcome. BMC Pregnancy Childbirth. 2016;16(1):128.PubMedPubMedCentralCrossRef
33.
Zurück zum Zitat Bakker R, Steegers EA, Mackenbach JP, Hofman A, Jaddoe VW. Maternal smoking and blood pressure in different trimesters of pregnancy: the generation R study. J Hypertens. 2010;28:2210–8.PubMedCrossRef Bakker R, Steegers EA, Mackenbach JP, Hofman A, Jaddoe VW. Maternal smoking and blood pressure in different trimesters of pregnancy: the generation R study. J Hypertens. 2010;28:2210–8.PubMedCrossRef
34.
Zurück zum Zitat Khan G, Ishrat N, Sabzposh N. Blood pressure patterns in pregnant women of different body mass index in three trimesters of pregnancy. Indian J Public Heal Res Dev. 2013;4(3):98–102.CrossRef Khan G, Ishrat N, Sabzposh N. Blood pressure patterns in pregnant women of different body mass index in three trimesters of pregnancy. Indian J Public Heal Res Dev. 2013;4(3):98–102.CrossRef
35.
Zurück zum Zitat Lauszus FF, Rosgaard A, Lousen T, Rasmussen OW, Klebe TM, Klebe JG. Precision, consistency, and reproducibility of blood pressure in diabetic and non-diabetic pregnancy: the appraisal of repeated measurements. Acta Obstet Gynecol Scand. 2007;86(9):1063–70.PubMedCrossRef Lauszus FF, Rosgaard A, Lousen T, Rasmussen OW, Klebe TM, Klebe JG. Precision, consistency, and reproducibility of blood pressure in diabetic and non-diabetic pregnancy: the appraisal of repeated measurements. Acta Obstet Gynecol Scand. 2007;86(9):1063–70.PubMedCrossRef
36.
Zurück zum Zitat Lee P-C, Talbott EO, Roberts JM, Catov JM, Bilonick RA, Stone RA, et al. Ambient air pollution exposure and blood pressure changes during pregnancy. Environ Res. 2012;117:46–53.PubMedPubMedCentralCrossRef Lee P-C, Talbott EO, Roberts JM, Catov JM, Bilonick RA, Stone RA, et al. Ambient air pollution exposure and blood pressure changes during pregnancy. Environ Res. 2012;117:46–53.PubMedPubMedCentralCrossRef
37.
Zurück zum Zitat Lo C, Taylor RS, Gamble G, McCowan L, North RA. Use of automated home blood pressure monitoring in pregnancy: is it safe? Am J Obstet Gynecol. 2002;187(5):1321–8.PubMedCrossRef Lo C, Taylor RS, Gamble G, McCowan L, North RA. Use of automated home blood pressure monitoring in pregnancy: is it safe? Am J Obstet Gynecol. 2002;187(5):1321–8.PubMedCrossRef
38.
Zurück zum Zitat Macdonald-Wallis C, Silverwood RJ, Fraser A, Nelson SM, Tilling K, Lawlor DA, et al. Gestational-age-specific reference ranges for blood pressure in pregnancy: findings from a prospective cohort. J Hypertens. 2015;33(1):96–105.PubMedCrossRef Macdonald-Wallis C, Silverwood RJ, Fraser A, Nelson SM, Tilling K, Lawlor DA, et al. Gestational-age-specific reference ranges for blood pressure in pregnancy: findings from a prospective cohort. J Hypertens. 2015;33(1):96–105.PubMedCrossRef
39.
Zurück zum Zitat MacGillivray I, Rose GA, Rowe B. Blood pressure survey in pregnancy. Clin Sci. 1969;37(2):395–407.PubMed MacGillivray I, Rose GA, Rowe B. Blood pressure survey in pregnancy. Clin Sci. 1969;37(2):395–407.PubMed
40.
Zurück zum Zitat Matkin CC, Britton J, Samuels S, Eskenazi B. Smoking and blood pressure patterns in normotensive pregnant women. Paediatr Perinat Epidemiol. 1999;13(1):22–34.PubMedCrossRef Matkin CC, Britton J, Samuels S, Eskenazi B. Smoking and blood pressure patterns in normotensive pregnant women. Paediatr Perinat Epidemiol. 1999;13(1):22–34.PubMedCrossRef
41.
Zurück zum Zitat Miller RS, Thompson ML, Williams MA. Trimester-specific blood pressure levels in relation to maternal pre-pregnancy body. Paediatr Perinat Epidemiol. 2007;21(6):487–94.PubMedCrossRef Miller RS, Thompson ML, Williams MA. Trimester-specific blood pressure levels in relation to maternal pre-pregnancy body. Paediatr Perinat Epidemiol. 2007;21(6):487–94.PubMedCrossRef
42.
Zurück zum Zitat Mahendru AA, Everett TR, Wilkinson IB, Lees CC, McEniery CM. A longitudinal study of maternal cardiovascular function from preconception to the postpartum period. J Hypertens. 2014;32(4):849–56.PubMedCrossRef Mahendru AA, Everett TR, Wilkinson IB, Lees CC, McEniery CM. A longitudinal study of maternal cardiovascular function from preconception to the postpartum period. J Hypertens. 2014;32(4):849–56.PubMedCrossRef
43.
Zurück zum Zitat Nama V, Antonios TF, Onwude J, Manyonda IT. Mid-trimester blood pressure drop in normal pregnancy: myth or reality? J Hypertens. 2011;29(4):763–8.PubMedCrossRef Nama V, Antonios TF, Onwude J, Manyonda IT. Mid-trimester blood pressure drop in normal pregnancy: myth or reality? J Hypertens. 2011;29(4):763–8.PubMedCrossRef
44.
Zurück zum Zitat Churchill D, Beevers DG. Differences between office and 24-hour ambulatory blood pressure measurement during pregnancy. Obstet Gynecol. 1996;88(3):455–61.PubMedCrossRef Churchill D, Beevers DG. Differences between office and 24-hour ambulatory blood pressure measurement during pregnancy. Obstet Gynecol. 1996;88(3):455–61.PubMedCrossRef
45.
Zurück zum Zitat Okonofua FE, Balogun JA, Amiengheme NA, O’Brien SPM. Blood pressure changes during pregnancy in Nigerian women. Int J Cardiol. 1992;37(3):373–9.PubMedCrossRef Okonofua FE, Balogun JA, Amiengheme NA, O’Brien SPM. Blood pressure changes during pregnancy in Nigerian women. Int J Cardiol. 1992;37(3):373–9.PubMedCrossRef
46.
Zurück zum Zitat Peterson CM, Jovanovic-Peterson L, Mills JL, Conley MR, Knopp RH, Reed GF, et al. The diabetes in early pregnancy study: changes in cholesterol, triglycerides, body weight, and blood pressure. The National Institute of Child Health and Human Development--the diabetes in early pregnancy study. Am J Obstet Gynecol. 1992;166(2):513–8.PubMedCrossRef Peterson CM, Jovanovic-Peterson L, Mills JL, Conley MR, Knopp RH, Reed GF, et al. The diabetes in early pregnancy study: changes in cholesterol, triglycerides, body weight, and blood pressure. The National Institute of Child Health and Human Development--the diabetes in early pregnancy study. Am J Obstet Gynecol. 1992;166(2):513–8.PubMedCrossRef
47.
Zurück zum Zitat Strevens H, Wide-Swensson D, Ingemarsson I. Blood pressure during pregnancy in a Swedish population; impact of parity. Acta Obs Gynecol Scand. 2001;80(9):824–9.CrossRef Strevens H, Wide-Swensson D, Ingemarsson I. Blood pressure during pregnancy in a Swedish population; impact of parity. Acta Obs Gynecol Scand. 2001;80(9):824–9.CrossRef
48.
Zurück zum Zitat Grindheim G, Estensen ME, Langesaeter E, Rosseland L, Toska K. Changes in blood pressure during healthy pregnancy: a longitudinal cohort study. J Hypertens. 2012;30(2):342–50.PubMedCrossRef Grindheim G, Estensen ME, Langesaeter E, Rosseland L, Toska K. Changes in blood pressure during healthy pregnancy: a longitudinal cohort study. J Hypertens. 2012;30(2):342–50.PubMedCrossRef
49.
Zurück zum Zitat Halligan A, O’Brien E, O’Malley K, Mee F. Twenty-four-hour ambulatory blood pressure measurement in a primigravid population. J Hpertension. 1993;11:869–73.CrossRef Halligan A, O’Brien E, O’Malley K, Mee F. Twenty-four-hour ambulatory blood pressure measurement in a primigravid population. J Hpertension. 1993;11:869–73.CrossRef
50.
Zurück zum Zitat Hilmert CJ, Schetter CD, Dominguez TP, Abdou C, Hobel CJ, Glynn L, et al. Stress and blood pressure during pregnancy: racial differences and associations with birthweight. Psychosom Med. 2008;70(1):57–64.PubMedCrossRef Hilmert CJ, Schetter CD, Dominguez TP, Abdou C, Hobel CJ, Glynn L, et al. Stress and blood pressure during pregnancy: racial differences and associations with birthweight. Psychosom Med. 2008;70(1):57–64.PubMedCrossRef
51.
Zurück zum Zitat Ishikuro M, Obara T, Metoki H, Ohkubo T, Yamamoto M, Akutsu K, et al. Blood pressure measured in the clinic and at home during pregnancy among nulliparous and multiparous women: the BOSHI study. Am J Hypertens. 2013;26(1):141–8.PubMedCrossRef Ishikuro M, Obara T, Metoki H, Ohkubo T, Yamamoto M, Akutsu K, et al. Blood pressure measured in the clinic and at home during pregnancy among nulliparous and multiparous women: the BOSHI study. Am J Hypertens. 2013;26(1):141–8.PubMedCrossRef
52.
Zurück zum Zitat Iwasaki R, Ohkuchi A, Furuta I, Ojima T, Matsubara S, Sato I, et al. Relationship between blood pressure level in early pregnancy and subsequent changes in blood pressure during pregnancy. Acta Obstet Gynecol Scand. 2002;81(10):918–25.PubMedCrossRef Iwasaki R, Ohkuchi A, Furuta I, Ojima T, Matsubara S, Sato I, et al. Relationship between blood pressure level in early pregnancy and subsequent changes in blood pressure during pregnancy. Acta Obstet Gynecol Scand. 2002;81(10):918–25.PubMedCrossRef
53.
Zurück zum Zitat Jasovic-Siveska E, Jasovic V. Prediction of mild and severe preeclampsia with blood pressure measurements in first and second trimester of pregnancy. Ginekol Pol. 2011;82(11):845–50.PubMed Jasovic-Siveska E, Jasovic V. Prediction of mild and severe preeclampsia with blood pressure measurements in first and second trimester of pregnancy. Ginekol Pol. 2011;82(11):845–50.PubMed
54.
Zurück zum Zitat Kac G, Mendes RH, Farias DR, Eshriqui I, Rebelo F, Benaim C, et al. Hepatic, renal and inflammatory biomarkers are positively associated with blood pressure changes in healthy pregnant women: a prospective cohort. Medicine (Baltimore). 2015;94(20):e683.CrossRef Kac G, Mendes RH, Farias DR, Eshriqui I, Rebelo F, Benaim C, et al. Hepatic, renal and inflammatory biomarkers are positively associated with blood pressure changes in healthy pregnant women: a prospective cohort. Medicine (Baltimore). 2015;94(20):e683.CrossRef
55.
Zurück zum Zitat Amoakoh-Coleman M, Ogum-Alangea D, Modey-Amoah E, Yao Ntumy M, Adanu R, Oppong S. Blood pressure patterns and body mass index status in pregnancy: an assessment among women reporting for antenatal care at the Korle-Bu teaching hospital. Ghana PLoS One. 2017;12(12):e0188671.PubMedCrossRef Amoakoh-Coleman M, Ogum-Alangea D, Modey-Amoah E, Yao Ntumy M, Adanu R, Oppong S. Blood pressure patterns and body mass index status in pregnancy: an assessment among women reporting for antenatal care at the Korle-Bu teaching hospital. Ghana PLoS One. 2017;12(12):e0188671.PubMedCrossRef
56.
Zurück zum Zitat Veerabhadrappa ST, Vyas AL, Anand S. Changes in heart rate variability and pulse wave characteristics during normal pregnancy and postpartum. Int J Biomed Eng Technol. 2015;17(2):99.CrossRef Veerabhadrappa ST, Vyas AL, Anand S. Changes in heart rate variability and pulse wave characteristics during normal pregnancy and postpartum. Int J Biomed Eng Technol. 2015;17(2):99.CrossRef
57.
Zurück zum Zitat Ekholm E, Erkkolab R, Hartiala J. Comparison of cardiovascular reflex tests and blood pressure measurement in prediction of pregnancy-induced hypertension. Eur J Obstet Gynecol Reprod Biol. 1994;54:37–41.PubMedCrossRef Ekholm E, Erkkolab R, Hartiala J. Comparison of cardiovascular reflex tests and blood pressure measurement in prediction of pregnancy-induced hypertension. Eur J Obstet Gynecol Reprod Biol. 1994;54:37–41.PubMedCrossRef
58.
Zurück zum Zitat Elvan-Taşpinar A, Uiterkamp L, Sikkems JM, Bots ML, Koomans HW, Bruinse HA, et al. Validation and use of the Finometer™ for blood pressure measurement in normal, hypertensive and pre-eclamptic pregnancy. J Hypertens. 2003;21(11):2053–60.PubMedCrossRef Elvan-Taşpinar A, Uiterkamp L, Sikkems JM, Bots ML, Koomans HW, Bruinse HA, et al. Validation and use of the Finometer™ for blood pressure measurement in normal, hypertensive and pre-eclamptic pregnancy. J Hypertens. 2003;21(11):2053–60.PubMedCrossRef
59.
Zurück zum Zitat Foo FL, Collins A, McEniery CM, Bennett PR, Wilkinson IB, Lees CC. Preconception and early pregnancy maternal haemodynamic changes in healthy women in relation to pregnancy viability. Hum Reprod. 2017;32(5):985–92.PubMedCrossRef Foo FL, Collins A, McEniery CM, Bennett PR, Wilkinson IB, Lees CC. Preconception and early pregnancy maternal haemodynamic changes in healthy women in relation to pregnancy viability. Hum Reprod. 2017;32(5):985–92.PubMedCrossRef
60.
Zurück zum Zitat Ngan Kee WD, Shaw K, Ng FF, Karmakar MK, Critchley LA, Gin T. A prospective comparison of vasopressor requirement and hemodynamic changes during spinal anesthesia for cesarean delivery in patients with multiple gestation versus singleton pregnancy. Anesth Analg. 2007;104:407–11.PubMedCrossRef Ngan Kee WD, Shaw K, Ng FF, Karmakar MK, Critchley LA, Gin T. A prospective comparison of vasopressor requirement and hemodynamic changes during spinal anesthesia for cesarean delivery in patients with multiple gestation versus singleton pregnancy. Anesth Analg. 2007;104:407–11.PubMedCrossRef
61.
Zurück zum Zitat Ochsenbein-Kolble N, Roos M, Gasser T, Huch R, Huch A, Zimmermann R. Cross sectional study of automated blood pressure measurements throughout pregnancy. BJOG An Int J Obstet Gynaecol. 2004;111(4):319–25.CrossRef Ochsenbein-Kolble N, Roos M, Gasser T, Huch R, Huch A, Zimmermann R. Cross sectional study of automated blood pressure measurements throughout pregnancy. BJOG An Int J Obstet Gynaecol. 2004;111(4):319–25.CrossRef
62.
Zurück zum Zitat Tape TG, Rayburn WF, Bremer KD, Schnoor TA. Ambulatory blood pressure monitoring during pregnancy with a new, small, easily concealed monitor. J Reprod Med. 1994;39(12):968–72.PubMed Tape TG, Rayburn WF, Bremer KD, Schnoor TA. Ambulatory blood pressure monitoring during pregnancy with a new, small, easily concealed monitor. J Reprod Med. 1994;39(12):968–72.PubMed
63.
Zurück zum Zitat Tuffnell DJ, Buchan PC, Albert D, Tyndale-biscoe S. Fetal heart rate responses to maternal exercise, increased maternal temperature and maternal circadian variation. J Obstet Gynaecol. 1990;10(5):387–91.CrossRef Tuffnell DJ, Buchan PC, Albert D, Tyndale-biscoe S. Fetal heart rate responses to maternal exercise, increased maternal temperature and maternal circadian variation. J Obstet Gynaecol. 1990;10(5):387–91.CrossRef
64.
Zurück zum Zitat Van Der Graaf AM, Zeeman GG, Groen H, Roberts C, Dekker GA. Non-invasive assessment of maternal hemodynamics in early pregnancy. Pregnancy Hypertens. 2013;3(4):261–9.PubMedCrossRef Van Der Graaf AM, Zeeman GG, Groen H, Roberts C, Dekker GA. Non-invasive assessment of maternal hemodynamics in early pregnancy. Pregnancy Hypertens. 2013;3(4):261–9.PubMedCrossRef
65.
Zurück zum Zitat Gu H, Zhang S, Qiao Y, Luo Z, Zeng Y, Wang Q. A study of maternal hemodynamic change during healthy pregnancy and women with gestation hypertension. Biomed Mater Eng. 1991;16(1):77–82. Gu H, Zhang S, Qiao Y, Luo Z, Zeng Y, Wang Q. A study of maternal hemodynamic change during healthy pregnancy and women with gestation hypertension. Biomed Mater Eng. 1991;16(1):77–82.
66.
Zurück zum Zitat van Oppen ACC, Van Der Tweel I, Alsbach GPJ, Heethaar RM, Bruinse HW. A longitudinal study of maternal hemodynamics during normal pregnancy. Obstet Gynecol. 1996;88(96):40–6.PubMed van Oppen ACC, Van Der Tweel I, Alsbach GPJ, Heethaar RM, Bruinse HW. A longitudinal study of maternal hemodynamics during normal pregnancy. Obstet Gynecol. 1996;88(96):40–6.PubMed
67.
Zurück zum Zitat Carpenter R, D’Silva L, Emery SJ, Ulan O, Rassi D, Lewis MJ. Changes in heart rate variability and QT variability during the first trimester of pregnancy. Physiol Meas. 2015;36:531–45.PubMedCrossRef Carpenter R, D’Silva L, Emery SJ, Ulan O, Rassi D, Lewis MJ. Changes in heart rate variability and QT variability during the first trimester of pregnancy. Physiol Meas. 2015;36:531–45.PubMedCrossRef
68.
Zurück zum Zitat Guy GP, Ling HZ, Machuca M, Poon LC, Nicolaides KH. Effect of change in posture on maternal functional hemodynamics at 35–37 weeks’ gestation. Ultrasound Obstet Gynecol. 2018;51(3):368–74.PubMedCrossRef Guy GP, Ling HZ, Machuca M, Poon LC, Nicolaides KH. Effect of change in posture on maternal functional hemodynamics at 35–37 weeks’ gestation. Ultrasound Obstet Gynecol. 2018;51(3):368–74.PubMedCrossRef
69.
Zurück zum Zitat Turan OM, De Paco C, Kametas N, Khaw A, Nicolaides KH. Effect of parity on maternal cardiac function during the first trimester of pregnancy. Ultrasound Obstet Gynecol. 2008;32(7):849–54.PubMedCrossRef Turan OM, De Paco C, Kametas N, Khaw A, Nicolaides KH. Effect of parity on maternal cardiac function during the first trimester of pregnancy. Ultrasound Obstet Gynecol. 2008;32(7):849–54.PubMedCrossRef
70.
Zurück zum Zitat Sanghavi M, Rutherford JD. Cardiovascular physiology of pregnancy. Circulation. 2014;130(12):1003–8.PubMedCrossRef Sanghavi M, Rutherford JD. Cardiovascular physiology of pregnancy. Circulation. 2014;130(12):1003–8.PubMedCrossRef
71.
Zurück zum Zitat Wright JD, Hughes JP, Ostchega Y, Yoon SS, Nwankwo T. Mean systolic and diastolic blood pressure in adults aged 18 and over in the United States, 2001–2008. Natl Health Stat Report. 2011;35:1-22, 24 Wright JD, Hughes JP, Ostchega Y, Yoon SS, Nwankwo T. Mean systolic and diastolic blood pressure in adults aged 18 and over in the United States, 2001–2008. Natl Health Stat Report. 2011;35:1-22, 24
73.
Zurück zum Zitat Macdonald-Wallis C, Lawlor DA, Fraser A, May M, Scott M. Blood pressure change in normotensive, gestational hypertensive, preeclamptic and essential hypertensive pregnancies. Hypertension. 2012;59(6):1241–8.PubMedCrossRef Macdonald-Wallis C, Lawlor DA, Fraser A, May M, Scott M. Blood pressure change in normotensive, gestational hypertensive, preeclamptic and essential hypertensive pregnancies. Hypertension. 2012;59(6):1241–8.PubMedCrossRef
74.
Zurück zum Zitat Mills M, Rindfuss RR, McDonald P, te Velde E. Why do people postpone parenthood? Reasons and social policy incentives. Hum Reprod Update. 2011;17(6):848–60.PubMedPubMedCentralCrossRef Mills M, Rindfuss RR, McDonald P, te Velde E. Why do people postpone parenthood? Reasons and social policy incentives. Hum Reprod Update. 2011;17(6):848–60.PubMedPubMedCentralCrossRef
76.
Zurück zum Zitat Matthews TJ, Hamilton BE. First births to older women continue to rise. NCHS Data Brief. 2014;152:1–8. Matthews TJ, Hamilton BE. First births to older women continue to rise. NCHS Data Brief. 2014;152:1–8.
77.
Zurück zum Zitat Heslehurst N, Rankin J, Wilkinson JRR, Summerbell CDD. A nationally representative study of maternal obesity in England, UK: trends in incidence and demographic inequalities in 619 323 births, 1989-2007. Int J Obes. 2010;34(3):420–8.CrossRef Heslehurst N, Rankin J, Wilkinson JRR, Summerbell CDD. A nationally representative study of maternal obesity in England, UK: trends in incidence and demographic inequalities in 619 323 births, 1989-2007. Int J Obes. 2010;34(3):420–8.CrossRef
78.
Zurück zum Zitat Gupta M, Shennan AH, Halligan A, Taylor DJ, de Swiet M. Accuracy of oscillometric blood pressure monitoring in pregnancy and pre-eclampsia. BJOG. 1997;104(3):350–5.CrossRef Gupta M, Shennan AH, Halligan A, Taylor DJ, de Swiet M. Accuracy of oscillometric blood pressure monitoring in pregnancy and pre-eclampsia. BJOG. 1997;104(3):350–5.CrossRef
79.
Zurück zum Zitat Natarajan P, Shennan AH, Penny J, Halligan AW, de Swiet M, Anthony J. Comparison of auscultatory and oscillometric automated blood pressure monitors in the setting of preeclampsia. Am J Obstet Gynecol. 1999;181(5):1203–10.PubMedCrossRef Natarajan P, Shennan AH, Penny J, Halligan AW, de Swiet M, Anthony J. Comparison of auscultatory and oscillometric automated blood pressure monitors in the setting of preeclampsia. Am J Obstet Gynecol. 1999;181(5):1203–10.PubMedCrossRef
80.
Zurück zum Zitat Reinders A, Cuckson AC, Jones CR, Poet R, O’Sullivan G, Shennan AH. Validation of the Welch Allyn “vital signs” blood pressure measurement device in pregnancy and pre-eclampsia. BJOG. 2003;110(2):134–8.PubMedCrossRef Reinders A, Cuckson AC, Jones CR, Poet R, O’Sullivan G, Shennan AH. Validation of the Welch Allyn “vital signs” blood pressure measurement device in pregnancy and pre-eclampsia. BJOG. 2003;110(2):134–8.PubMedCrossRef
81.
Zurück zum Zitat O’ Brien E, Atkins N, Stergiou G, Karpettas N, Parati G, Asmar R, et al. European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults. Blood Press Monit. 2010;15(1):23–38.CrossRef O’ Brien E, Atkins N, Stergiou G, Karpettas N, Parati G, Asmar R, et al. European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults. Blood Press Monit. 2010;15(1):23–38.CrossRef
82.
Zurück zum Zitat de Greeff A, Beg Z, Gangji Z, Dorney E, Shennan AH. Accuracy of inflationary versus deflationary oscillometry in pregnancy and preeclampsia: OMRON-MIT versus OMRON-M7. Blood Press Monit. 2009;14(1):37–40.PubMedCrossRef de Greeff A, Beg Z, Gangji Z, Dorney E, Shennan AH. Accuracy of inflationary versus deflationary oscillometry in pregnancy and preeclampsia: OMRON-MIT versus OMRON-M7. Blood Press Monit. 2009;14(1):37–40.PubMedCrossRef
83.
Zurück zum Zitat Golara M, Benedict A, Jones C, Randhawa M, Poston L, Shennan AH. Inflationary oscillometry provides accurate measurement of blood pressure in pre-eclampsia. BJOG. 2002;109(10):1143–7.PubMedCrossRef Golara M, Benedict A, Jones C, Randhawa M, Poston L, Shennan AH. Inflationary oscillometry provides accurate measurement of blood pressure in pre-eclampsia. BJOG. 2002;109(10):1143–7.PubMedCrossRef
84.
Zurück zum Zitat Reinders A, Cuckson AC, Lee JTM, Shennan AH. An accurate automated blood pressure device for use in pregnancy and pre-eclampsia: the Microlife 3BTO-A. BJOG. 2005;112(7):915–20.PubMedCrossRef Reinders A, Cuckson AC, Lee JTM, Shennan AH. An accurate automated blood pressure device for use in pregnancy and pre-eclampsia: the Microlife 3BTO-A. BJOG. 2005;112(7):915–20.PubMedCrossRef
85.
Zurück zum Zitat Chung Y, de Greeff A, Shennan A. Validation and compliance of a home monitoring device in pregnancy: Microlife WatchBP Home. Hypertens Pregnancy. 2009;28(3):348–59.PubMedCrossRef Chung Y, de Greeff A, Shennan A. Validation and compliance of a home monitoring device in pregnancy: Microlife WatchBP Home. Hypertens Pregnancy. 2009;28(3):348–59.PubMedCrossRef
Metadaten
Titel
Trends of blood pressure and heart rate in normal pregnancies: a systematic review and meta-analysis
verfasst von
Lise Loerup
Rebecca M. Pullon
Jacqueline Birks
Susannah Fleming
Lucy H. Mackillop
Stephen Gerry
Peter J. Watkinson
Publikationsdatum
01.12.2019
Verlag
BioMed Central
Erschienen in
BMC Medicine / Ausgabe 1/2019
Elektronische ISSN: 1741-7015
DOI
https://doi.org/10.1186/s12916-019-1399-1

Weitere Artikel der Ausgabe 1/2019

BMC Medicine 1/2019 Zur Ausgabe

Leitlinien kompakt für die Allgemeinmedizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Facharzt-Training Allgemeinmedizin

Die ideale Vorbereitung zur anstehenden Prüfung mit den ersten 24 von 100 klinischen Fallbeispielen verschiedener Themenfelder

Mehr erfahren

Strenge Blutdruckeinstellung lohnt auch im Alter noch

30.04.2024 Arterielle Hypertonie Nachrichten

Ältere Frauen, die von chronischen Erkrankungen weitgehend verschont sind, haben offenbar die besten Chancen, ihren 90. Geburtstag zu erleben, wenn ihr systolischer Blutdruck < 130 mmHg liegt. Das scheint selbst für 80-Jährige noch zu gelten.

Dihydropyridin-Kalziumantagonisten können auf die Nieren gehen

30.04.2024 Hypertonie Nachrichten

Im Vergleich zu anderen Blutdrucksenkern sind Kalziumantagonisten vom Diyhdropyridin-Typ mit einem erhöhten Risiko für eine Mikroalbuminurie und in Abwesenheit eines RAS-Blockers auch für ein terminales Nierenversagen verbunden.

Frauen bekommen seltener eine intensive Statintherapie

30.04.2024 Statine Nachrichten

Frauen in den Niederlanden erhalten bei vergleichbarem kardiovaskulärem Risiko seltener eine intensive Statintherapie als Männer. Ihre LDL-Zielwerte erreichen sie aber fast ähnlich oft.

Reizdarmsyndrom: Diäten wirksamer als Medikamente

29.04.2024 Reizdarmsyndrom Nachrichten

Bei Reizdarmsyndrom scheinen Diäten, wie etwa die FODMAP-arme oder die kohlenhydratreduzierte Ernährung, effektiver als eine medikamentöse Therapie zu sein. Das hat eine Studie aus Schweden ergeben, die die drei Therapieoptionen im direkten Vergleich analysierte.

Update Allgemeinmedizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.