Skip to main content
Erschienen in: European Radiology 2/2004

01.02.2004 | Hepatobiliary–Pancreas

3D CT modeling of hepatic vessel architecture and volume calculation in living donated liver transplantation

verfasst von: Bernd B. Frericks, Franco C. Caldarone, Björn Nashan, Dagmar Högemann Savellano, Georg Stamm, Timm D. Kirchhoff, Hoen-Oh Shin, Andrea Schenk, Dirk Selle, Wolf Spindler, Jürgen Klempnauer, Heinz-Otto Peitgen, Michael Galanski

Erschienen in: European Radiology | Ausgabe 2/2004

Einloggen, um Zugang zu erhalten

Abstract

The aim of this study was to evaluate a software tool for non-invasive preoperative volumetric assessment of potential donors in living donated liver transplantation (LDLT). Biphasic helical CT was performed in 56 potential donors. Data sets were post-processed using a non-commercial software tool for segmentation, volumetric analysis and visualisation of liver segments. Semi-automatic definition of liver margins allowed the segmentation of parenchyma. Hepatic vessels were delineated using a region-growing algorithm with automatically determined thresholds. Volumes and shapes of liver segments were calculated automatically based on individual portal-venous branches. Results were visualised three-dimensionally and statistically compared with conventional volumetry and the intraoperative findings in 27 transplanted cases. Image processing was easy to perform within 23 min. Of the 56 potential donors, 27 were excluded from LDLT because of inappropriate liver parenchyma or vascular architecture. Two recipients were not transplanted due to poor clinical conditions. In the 27 transplanted cases, preoperatively visualised vessels were confirmed, and only one undetected accessory hepatic vein was revealed. Calculated graft volumes were 1110±180 ml for right lobes, 820 ml for the left lobe and 270±30 ml for segments II+III. The calculated volumes and intraoperatively measured graft volumes correlated significantly. No significant differences between the presented automatic volumetry and the conventional volumetry were observed. A novel image processing technique was evaluated which allows a semi-automatic volume calculation and 3D visualisation of the different liver segments.
Literatur
1.
Zurück zum Zitat Emond JC, Renz JF, Ferrell LD, Rosenthal P, Lim RC, Roberts JP, Lake JR, Ascher NL (1996) Functional analysis of grafts from living donors: implications for the treatment of older recipients. Ann Surg 224:544–554CrossRefPubMed Emond JC, Renz JF, Ferrell LD, Rosenthal P, Lim RC, Roberts JP, Lake JR, Ascher NL (1996) Functional analysis of grafts from living donors: implications for the treatment of older recipients. Ann Surg 224:544–554CrossRefPubMed
2.
Zurück zum Zitat Ishifuro M, Horiguchi J, Nakashige A, Tamura A, Marukawa K, Fukuda H, Ono C, Akiyama Y, Kushima T, Ito K (2002) Use of multidetector-row CT with volume renderings in right lobe living liver transplantation. Eur Radiol 12:2477–2483PubMed Ishifuro M, Horiguchi J, Nakashige A, Tamura A, Marukawa K, Fukuda H, Ono C, Akiyama Y, Kushima T, Ito K (2002) Use of multidetector-row CT with volume renderings in right lobe living liver transplantation. Eur Radiol 12:2477–2483PubMed
3.
Zurück zum Zitat Kamel IR, Kruskal JB, Warmbrand G, Goldberg SN, Pomfret EA, Raptopoulos V (2001) Accuracy of volumetric measurements after virtual right hepatectomy in potential donors undergoing living adult liver transplantation. AJR 176:483–487 Kamel IR, Kruskal JB, Warmbrand G, Goldberg SN, Pomfret EA, Raptopoulos V (2001) Accuracy of volumetric measurements after virtual right hepatectomy in potential donors undergoing living adult liver transplantation. AJR 176:483–487
4.
Zurück zum Zitat Schroeder T, Nadalin S, Stattaus J, Debatin JF, Malagó M, Ruehm SG (2002) Potential living liver donors: evaluation with an all-in-one protocol with multidetector-row CT. Radiology 224:586–591PubMed Schroeder T, Nadalin S, Stattaus J, Debatin JF, Malagó M, Ruehm SG (2002) Potential living liver donors: evaluation with an all-in-one protocol with multidetector-row CT. Radiology 224:586–591PubMed
5.
Zurück zum Zitat Lamade W, Glombitza G, Fischer L, Chiu P, Cardenas CE, Thorn M, Meinzer HP, Grenacher L, Bauer H, Lehnert T, Herfarth C (2000) The impact of 3-dimensional reconstructions on operation planning in liver surgery. Arch Surg 135:1256–1261CrossRefPubMed Lamade W, Glombitza G, Fischer L, Chiu P, Cardenas CE, Thorn M, Meinzer HP, Grenacher L, Bauer H, Lehnert T, Herfarth C (2000) The impact of 3-dimensional reconstructions on operation planning in liver surgery. Arch Surg 135:1256–1261CrossRefPubMed
6.
Zurück zum Zitat Selle D, Spindler W, Schenk A (2000) Computerized models minimize surgical risk. Diagn Imaging Europe 12:16–20 Selle D, Spindler W, Schenk A (2000) Computerized models minimize surgical risk. Diagn Imaging Europe 12:16–20
7.
Zurück zum Zitat Schenk A, Prause G, Peitgen HO (2001) Local cost computation for efficient segmentation of 3D objects with Live Wire. Medical imaging: image processing. Proc SPIE 4322:1357–1364 Schenk A, Prause G, Peitgen HO (2001) Local cost computation for efficient segmentation of 3D objects with Live Wire. Medical imaging: image processing. Proc SPIE 4322:1357–1364
8.
Zurück zum Zitat Schenk A, Prause G, Peitgen HO (2000) Efficient semiautomatic segmentation of 3D objects in medical images. Medical image computing and computer-assisted intervention (MICCAI 2000). Springer, Berlin Heidelberg New York, pp 186–195 Schenk A, Prause G, Peitgen HO (2000) Efficient semiautomatic segmentation of 3D objects in medical images. Medical image computing and computer-assisted intervention (MICCAI 2000). Springer, Berlin Heidelberg New York, pp 186–195
9.
Zurück zum Zitat Selle D, Peitgen HO (2001) Analysis of the morphology and structure of vessel systems using skeletonization. SPIE Med Imaging 4321:271–281CrossRef Selle D, Peitgen HO (2001) Analysis of the morphology and structure of vessel systems using skeletonization. SPIE Med Imaging 4321:271–281CrossRef
10.
Zurück zum Zitat Selle D, Preim B, Schenk A, Peitgen HO (2002) Analysis of vasculature for liver surgical planning. IEEE Trans Med Imaging 21:1–15CrossRefPubMed Selle D, Preim B, Schenk A, Peitgen HO (2002) Analysis of vasculature for liver surgical planning. IEEE Trans Med Imaging 21:1–15CrossRefPubMed
11.
Zurück zum Zitat Alpern MB, Lawson TL, Foley WD, Perlman SJ, Reif LJ, Arevalos E, Rimm AA (1986) Focal hepatic masses and fatty infiltration detected by enhanced dynamic CT. Radiology 158:45–49PubMed Alpern MB, Lawson TL, Foley WD, Perlman SJ, Reif LJ, Arevalos E, Rimm AA (1986) Focal hepatic masses and fatty infiltration detected by enhanced dynamic CT. Radiology 158:45–49PubMed
12.
Zurück zum Zitat Heymsfield SB, Fulenwider T, Nordlinger B, Barlow R, Sones P, Kutner M (1979) Measurement of liver, kidney and spleen volume and mass by computed axial tomography. Ann Intern Med 90:185–187PubMed Heymsfield SB, Fulenwider T, Nordlinger B, Barlow R, Sones P, Kutner M (1979) Measurement of liver, kidney and spleen volume and mass by computed axial tomography. Ann Intern Med 90:185–187PubMed
13.
Zurück zum Zitat Van Thiel DH, Hagler NG, Schade RR, Skolnick ML, Heyl AP, Rosenblum E, Gavaler JS, Penkrot RJ (1985) In vivo hepatic volume determination using sonography and computed tomography: validation and comparison of the two techniques. Gastroenterology 88:1812–1817PubMed Van Thiel DH, Hagler NG, Schade RR, Skolnick ML, Heyl AP, Rosenblum E, Gavaler JS, Penkrot RJ (1985) In vivo hepatic volume determination using sonography and computed tomography: validation and comparison of the two techniques. Gastroenterology 88:1812–1817PubMed
14.
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 8476:307–310 Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 8476:307–310
15.
Zurück zum Zitat Fan ST, Lo CM, Liu CL, Yong BH, Chan JK, Ng IO (2000) Safety of donors in live-donor liver transplantation using right lobe grafts. Arch Surg 135:336–340CrossRefPubMed Fan ST, Lo CM, Liu CL, Yong BH, Chan JK, Ng IO (2000) Safety of donors in live-donor liver transplantation using right lobe grafts. Arch Surg 135:336–340CrossRefPubMed
16.
Zurück zum Zitat Kiuchi T, Kasahara M, Uryuhara K, Inomata Y, Uemoto S, Asonuma K, Egawa H, Fujita S, Hayashi M, Tanaka K (1999) Impact of graft-size mismatching on graft prognosis in liver transplantation from living donors. Transplantation 67:321–327 Kiuchi T, Kasahara M, Uryuhara K, Inomata Y, Uemoto S, Asonuma K, Egawa H, Fujita S, Hayashi M, Tanaka K (1999) Impact of graft-size mismatching on graft prognosis in liver transplantation from living donors. Transplantation 67:321–327
17.
Zurück zum Zitat Luccichenti G, Cademartiri F, Cobelli R, Pavone P (2003) Assessment of organ volume with different techniques using a living liver model. Eur Radiol 13:1286–1290PubMed Luccichenti G, Cademartiri F, Cobelli R, Pavone P (2003) Assessment of organ volume with different techniques using a living liver model. Eur Radiol 13:1286–1290PubMed
18.
Zurück zum Zitat Gao L, Heath DG, Kuszyk BS, Fishman EK (1996) Automatic liver segmentation technique for three-dimensional visualization of CT data. Radiology 201:359–364PubMed Gao L, Heath DG, Kuszyk BS, Fishman EK (1996) Automatic liver segmentation technique for three-dimensional visualization of CT data. Radiology 201:359–364PubMed
19.
Zurück zum Zitat Kawasaki S, Makuuchi M, Matsunami H, Hashikura Y, Ikegami T, Chisuwa H, Ikeno T, Noike T, Takayama T, Kawarazaki H (1993) Preoperative measurement of segmental liver volume of donors for living related liver transplantation. Hepatology 18:1115–1120PubMed Kawasaki S, Makuuchi M, Matsunami H, Hashikura Y, Ikegami T, Chisuwa H, Ikeno T, Noike T, Takayama T, Kawarazaki H (1993) Preoperative measurement of segmental liver volume of donors for living related liver transplantation. Hepatology 18:1115–1120PubMed
20.
Zurück zum Zitat Schiano TD, Bodian C, Schwartz ME, Glajchen N, Min AD (2000) Accuracy and significance of computed tomographic scan assessment of hepatic volume in patients undergoing liver transplantation. Transplantation 69:545–550PubMed Schiano TD, Bodian C, Schwartz ME, Glajchen N, Min AD (2000) Accuracy and significance of computed tomographic scan assessment of hepatic volume in patients undergoing liver transplantation. Transplantation 69:545–550PubMed
21.
Zurück zum Zitat Sandrasegaran K, Kwo PW, DiGirolamo D, Stockberger SM, Cummings OW, Kopecky KK (1999) Measurement of liver volume using spiral CT and the curved line and cubic spline algoriths: reproducibility and interobserver variation. Abdom Imaging 24:61–65CrossRefPubMed Sandrasegaran K, Kwo PW, DiGirolamo D, Stockberger SM, Cummings OW, Kopecky KK (1999) Measurement of liver volume using spiral CT and the curved line and cubic spline algoriths: reproducibility and interobserver variation. Abdom Imaging 24:61–65CrossRefPubMed
Metadaten
Titel
3D CT modeling of hepatic vessel architecture and volume calculation in living donated liver transplantation
verfasst von
Bernd B. Frericks
Franco C. Caldarone
Björn Nashan
Dagmar Högemann Savellano
Georg Stamm
Timm D. Kirchhoff
Hoen-Oh Shin
Andrea Schenk
Dirk Selle
Wolf Spindler
Jürgen Klempnauer
Heinz-Otto Peitgen
Michael Galanski
Publikationsdatum
01.02.2004
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 2/2004
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-2161-8

Weitere Artikel der Ausgabe 2/2004

European Radiology 2/2004 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.