Skip to main content
Erschienen in: European Radiology 5/2018

13.12.2017 | Urogenital

A direct comparison of contrast-enhanced ultrasound and dynamic contrast-enhanced magnetic resonance imaging for prostate cancer detection and prediction of aggressiveness

verfasst von: Alexander D. J. Baur, Julia Schwabe, Julian Rogasch, Andreas Maxeiner, Tobias Penzkofer, Carsten Stephan, Marc Rudl, Bernd Hamm, Ernst-Michael Jung, Thom Fischer

Erschienen in: European Radiology | Ausgabe 5/2018

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and contrast-enhanced ultrasound (CEUS) analyse tissue vascularization. We evaluated if CEUS can provide comparable information as DCE-MRI for the detection of prostate cancer (PCa) and prediction of its aggressiveness.

Material and methods

A post-hoc evaluation of 92 patients was performed. In each patient CEUS and DCE-MRI parameters of the most suspicious lesion identified on MRI were analysed. The predictive values for discrimination between benign lesions, low-/intermediate- and high-grade PCa were evaluated. Results of targeted biopsy served as reference standard (benign lesions, n=51; low- and intermediate-grade PCa [Gleason grade group 1 and 2], n=22; high-grade PCa [≥ Gleason grade group 3], n=19).

Results

In peripheral zone lesions of all tested CEUS parameters only time to peak (TTPCEUS) showed significant differences between benign lesions and PCa (AUC 0.65). Of all tested DCE-MRI parameters, rate constant (Kep) was the best discriminator of high-grade PCa in the whole prostate (AUC 0.83) and in peripheral zone lesions (AUC 0.89).

Conclusion

DCE-MRI showed a superior performance for detection of PCa and prediction of its aggressiveness. CEUS and DCE-MRI performed better in peripheral zone lesions than in transition zone lesions.

Key Points

• DCE-MRI gathers information about vascularization and capillary permeability characteristics of tissues.
• DCE-MRI can detect PCa and predict its aggressiveness.
• CEUS also gathers information about vascularization of tissues.
• For detection of PCa and prediction of aggressiveness DCE-MRI performed superiorly.
• Both imaging techniques performed better in peripheral zone lesions.
Literatur
1.
Zurück zum Zitat Shakir NA, Siddiqui MM, George AK et al (2017) Should Hypoechoic Lesions on Transrectal Ultrasound Be Sampled During Magnetic Resonance Imaging-targeted Prostate Biopsy? Urology 105:113–117CrossRefPubMed Shakir NA, Siddiqui MM, George AK et al (2017) Should Hypoechoic Lesions on Transrectal Ultrasound Be Sampled During Magnetic Resonance Imaging-targeted Prostate Biopsy? Urology 105:113–117CrossRefPubMed
2.
Zurück zum Zitat Welch HG, Albertsen PC (2009) Prostate cancer diagnosis and treatment after the introduction of prostate-specific antigen screening: 1986-2005. J Natl Cancer Inst 101:1325–1329CrossRefPubMedPubMedCentral Welch HG, Albertsen PC (2009) Prostate cancer diagnosis and treatment after the introduction of prostate-specific antigen screening: 1986-2005. J Natl Cancer Inst 101:1325–1329CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Ahmed HU, El-Shater Bosaily A, Brown LC et al (2017) Diagnostic accuracy of multi-parametric MRI and TRUS biopsy in prostate cancer (PROMIS): a paired validating confirmatory study. Lancet 389:815–822 Ahmed HU, El-Shater Bosaily A, Brown LC et al (2017) Diagnostic accuracy of multi-parametric MRI and TRUS biopsy in prostate cancer (PROMIS): a paired validating confirmatory study. Lancet 389:815–822
4.
Zurück zum Zitat Ukimura O, Coleman JA, de la Taille A et al (2013) Contemporary role of systematic prostate biopsies: indications, techniques, and implications for patient care. Eur Urol 63:214–230CrossRefPubMed Ukimura O, Coleman JA, de la Taille A et al (2013) Contemporary role of systematic prostate biopsies: indications, techniques, and implications for patient care. Eur Urol 63:214–230CrossRefPubMed
5.
Zurück zum Zitat Washington SL, Bonham M, Whitson JM, Cowan JE, Carroll PR (2012) Transrectal ultrasonography-guided biopsy does not reliably identify dominant cancer location in men with low-risk prostate cancer. BJU Int 110:50–55CrossRefPubMed Washington SL, Bonham M, Whitson JM, Cowan JE, Carroll PR (2012) Transrectal ultrasonography-guided biopsy does not reliably identify dominant cancer location in men with low-risk prostate cancer. BJU Int 110:50–55CrossRefPubMed
7.
Zurück zum Zitat Cornelis F, Rigou G, Le Bras Y et al (2013) Real-time contrast-enhanced transrectal US-guided prostate biopsy: diagnostic accuracy in men with previously negative biopsy results and positive MR imaging findings. Radiology 269:159–166CrossRefPubMed Cornelis F, Rigou G, Le Bras Y et al (2013) Real-time contrast-enhanced transrectal US-guided prostate biopsy: diagnostic accuracy in men with previously negative biopsy results and positive MR imaging findings. Radiology 269:159–166CrossRefPubMed
8.
Zurück zum Zitat Durmus T, Stephan C, Grigoryev M et al (2013) Detection of prostate cancer by real-time MR/ultrasound fusion-guided biopsy: 3T MRI and state of the art sonography. Rofo 185:428–433CrossRefPubMed Durmus T, Stephan C, Grigoryev M et al (2013) Detection of prostate cancer by real-time MR/ultrasound fusion-guided biopsy: 3T MRI and state of the art sonography. Rofo 185:428–433CrossRefPubMed
9.
Zurück zum Zitat Schoots IG, Roobol MJ, Nieboer D, Bangma CH, Steyerberg EW, Hunink MG (2015) Magnetic resonance imaging-targeted biopsy may enhance the diagnostic accuracy of significant prostate cancer detection compared to standard transrectal ultrasound-guided biopsy: a systematic review and meta-analysis. Eur Urol 68:438–450CrossRefPubMed Schoots IG, Roobol MJ, Nieboer D, Bangma CH, Steyerberg EW, Hunink MG (2015) Magnetic resonance imaging-targeted biopsy may enhance the diagnostic accuracy of significant prostate cancer detection compared to standard transrectal ultrasound-guided biopsy: a systematic review and meta-analysis. Eur Urol 68:438–450CrossRefPubMed
10.
Zurück zum Zitat Siddiqui MM, Rais-Bahrami S, Turkbey B et al (2015) Comparison of MR/ultrasound fusion-guided biopsy with ultrasound-guided biopsy for the diagnosis of prostate cancer. JAMA 313:390–397CrossRefPubMedPubMedCentral Siddiqui MM, Rais-Bahrami S, Turkbey B et al (2015) Comparison of MR/ultrasound fusion-guided biopsy with ultrasound-guided biopsy for the diagnosis of prostate cancer. JAMA 313:390–397CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Sonn GA, Chang E, Natarajan S et al (2014) Value of targeted prostate biopsy using magnetic resonance-ultrasound fusion in men with prior negative biopsy and elevated prostate-specific antigen. Eur Urol 65:809–815CrossRefPubMed Sonn GA, Chang E, Natarajan S et al (2014) Value of targeted prostate biopsy using magnetic resonance-ultrasound fusion in men with prior negative biopsy and elevated prostate-specific antigen. Eur Urol 65:809–815CrossRefPubMed
12.
Zurück zum Zitat Erbersdobler A, Isbarn H, Dix K et al (2010) Prognostic value of microvessel density in prostate cancer: a tissue microarray study. World J Urol 28:687–692CrossRefPubMed Erbersdobler A, Isbarn H, Dix K et al (2010) Prognostic value of microvessel density in prostate cancer: a tissue microarray study. World J Urol 28:687–692CrossRefPubMed
13.
Zurück zum Zitat Padhani AR, Harvey CJ, Cosgrove DO (2005) Angiogenesis imaging in the management of prostate cancer. Nat Clin Pract Urol 2:596–607CrossRefPubMed Padhani AR, Harvey CJ, Cosgrove DO (2005) Angiogenesis imaging in the management of prostate cancer. Nat Clin Pract Urol 2:596–607CrossRefPubMed
14.
Zurück zum Zitat Oto A, Yang C, Kayhan A et al (2011) Diffusion-weighted and dynamic contrast-enhanced MRI of prostate cancer: correlation of quantitative MR parameters with Gleason score and tumor angiogenesis. AJR Am J Roentgenol 197:1382–1390CrossRefPubMed Oto A, Yang C, Kayhan A et al (2011) Diffusion-weighted and dynamic contrast-enhanced MRI of prostate cancer: correlation of quantitative MR parameters with Gleason score and tumor angiogenesis. AJR Am J Roentgenol 197:1382–1390CrossRefPubMed
15.
Zurück zum Zitat Halpern EJ, Ramey JR, Strup SE, Frauscher F, McCue P, Gomella LG (2005) Detection of prostate carcinoma with contrast-enhanced sonography using intermittent harmonic imaging. Cancer 104:2373–2383CrossRefPubMed Halpern EJ, Ramey JR, Strup SE, Frauscher F, McCue P, Gomella LG (2005) Detection of prostate carcinoma with contrast-enhanced sonography using intermittent harmonic imaging. Cancer 104:2373–2383CrossRefPubMed
16.
Zurück zum Zitat Jung EM, Wiggermann P, Greis C et al (2012) First results of endocavity evaluation of the microvascularization of malignant prostate tumors using contrast enhanced ultrasound (CEUS) including perfusion analysis: first results. Clin Hemorheol Microcirc 52:167–177PubMed Jung EM, Wiggermann P, Greis C et al (2012) First results of endocavity evaluation of the microvascularization of malignant prostate tumors using contrast enhanced ultrasound (CEUS) including perfusion analysis: first results. Clin Hemorheol Microcirc 52:167–177PubMed
17.
Zurück zum Zitat Maxeiner A, Stephan C, Durmus T, Slowinski T, Cash H, Fischer T (2015) Added Value of Multiparametric Ultrasonography in Magnetic Resonance Imaging and Ultrasonography Fusion-guided Biopsy of the Prostate in Patients With Suspicion for Prostate Cancer. Urology 86:108–114CrossRefPubMed Maxeiner A, Stephan C, Durmus T, Slowinski T, Cash H, Fischer T (2015) Added Value of Multiparametric Ultrasonography in Magnetic Resonance Imaging and Ultrasonography Fusion-guided Biopsy of the Prostate in Patients With Suspicion for Prostate Cancer. Urology 86:108–114CrossRefPubMed
18.
Zurück zum Zitat Starobinets O, Kurhanewicz J, Noworolski SM (2017) Improved multiparametric MRI discrimination between low-risk prostate cancer and benign tissues in a small cohort of 5alpha-reductase inhibitor treated individuals as compared with an untreated cohort. NMR Biomed 30 Starobinets O, Kurhanewicz J, Noworolski SM (2017) Improved multiparametric MRI discrimination between low-risk prostate cancer and benign tissues in a small cohort of 5alpha-reductase inhibitor treated individuals as compared with an untreated cohort. NMR Biomed 30
20.
Zurück zum Zitat Piscaglia F, Nolsoe C, Dietrich CF et al (2012) The EFSUMB Guidelines and Recommendations on the Clinical Practice of Contrast Enhanced Ultrasound (CEUS): update 2011 on non-hepatic applications. Ultraschall Med 33:33–59CrossRefPubMed Piscaglia F, Nolsoe C, Dietrich CF et al (2012) The EFSUMB Guidelines and Recommendations on the Clinical Practice of Contrast Enhanced Ultrasound (CEUS): update 2011 on non-hepatic applications. Ultraschall Med 33:33–59CrossRefPubMed
21.
Zurück zum Zitat Franiel T, Hamm B, Hricak H (2011) Dynamic contrast-enhanced magnetic resonance imaging and pharmacokinetic models in prostate cancer. Eur Radiol 21:616–626CrossRefPubMed Franiel T, Hamm B, Hricak H (2011) Dynamic contrast-enhanced magnetic resonance imaging and pharmacokinetic models in prostate cancer. Eur Radiol 21:616–626CrossRefPubMed
22.
Zurück zum Zitat Epstein JI, Allsbrook WC Jr, Amin MB, Egevad LL, Committee IG (2005) The 2005 International Society of Urological Pathology (ISUP) Consensus Conference on Gleason Grading of Prostatic Carcinoma. Am J Surg Pathol 29:1228–1242CrossRefPubMed Epstein JI, Allsbrook WC Jr, Amin MB, Egevad LL, Committee IG (2005) The 2005 International Society of Urological Pathology (ISUP) Consensus Conference on Gleason Grading of Prostatic Carcinoma. Am J Surg Pathol 29:1228–1242CrossRefPubMed
23.
Zurück zum Zitat Epstein JI, Egevad L, Amin MB et al (2016) The 2014 International Society of Urological Pathology (ISUP) Consensus Conference on Gleason Grading of Prostatic Carcinoma: Definition of Grading Patterns and Proposal for a New Grading System. Am J Surg Pathol 40:244–252PubMed Epstein JI, Egevad L, Amin MB et al (2016) The 2014 International Society of Urological Pathology (ISUP) Consensus Conference on Gleason Grading of Prostatic Carcinoma: Definition of Grading Patterns and Proposal for a New Grading System. Am J Surg Pathol 40:244–252PubMed
24.
Zurück zum Zitat Bender R, Lange S (2001) Adjusting for multiple testing--when and how? J Clin Epidemiol 54:343–349CrossRefPubMed Bender R, Lange S (2001) Adjusting for multiple testing--when and how? J Clin Epidemiol 54:343–349CrossRefPubMed
25.
Zurück zum Zitat Gulani V, Calamante F, Shellock FG, Kanal E, Reeder SB, International Society for Magnetic Resonance in M (2017) Gadolinium deposition in the brain: summary of evidence and recommendations. Lancet Neurol 16:564–570CrossRefPubMed Gulani V, Calamante F, Shellock FG, Kanal E, Reeder SB, International Society for Magnetic Resonance in M (2017) Gadolinium deposition in the brain: summary of evidence and recommendations. Lancet Neurol 16:564–570CrossRefPubMed
26.
Zurück zum Zitat Delgado Oliva F, Arlandis Guzman S, Bonillo Garcia M, Broseta Rico E, Boronat Tormo F (2016) Diagnostic performance of power doppler and ultrasound contrast agents in early imaging-based diagnosis of organ-confined prostate cancer: Is it possible to spare cores with contrast-guided biopsy? Eur J Radiol 85:1778–1785CrossRefPubMed Delgado Oliva F, Arlandis Guzman S, Bonillo Garcia M, Broseta Rico E, Boronat Tormo F (2016) Diagnostic performance of power doppler and ultrasound contrast agents in early imaging-based diagnosis of organ-confined prostate cancer: Is it possible to spare cores with contrast-guided biopsy? Eur J Radiol 85:1778–1785CrossRefPubMed
27.
Zurück zum Zitat van Niekerk CG, Witjes JA, Barentsz JO, van der Laak JA, Hulsbergen-van de Kaa CA (2013) Microvascularity in transition zone prostate tumors resembles normal prostatic tissue. Prostate 73:467–475CrossRefPubMed van Niekerk CG, Witjes JA, Barentsz JO, van der Laak JA, Hulsbergen-van de Kaa CA (2013) Microvascularity in transition zone prostate tumors resembles normal prostatic tissue. Prostate 73:467–475CrossRefPubMed
28.
Zurück zum Zitat Postema AW, Frinking PJ, Smeenge M et al (2016) Dynamic contrast-enhanced ultrasound parametric imaging for the detection of prostate cancer. BJU Int 117:598–603CrossRefPubMed Postema AW, Frinking PJ, Smeenge M et al (2016) Dynamic contrast-enhanced ultrasound parametric imaging for the detection of prostate cancer. BJU Int 117:598–603CrossRefPubMed
29.
Zurück zum Zitat Hansford BG, Peng Y, Jiang Y et al (2015) Dynamic Contrast-enhanced MR Imaging Curve-type Analysis: Is It Helpful in the Differentiation of Prostate Cancer from Healthy Peripheral Zone? Radiology 275:448–457CrossRefPubMed Hansford BG, Peng Y, Jiang Y et al (2015) Dynamic Contrast-enhanced MR Imaging Curve-type Analysis: Is It Helpful in the Differentiation of Prostate Cancer from Healthy Peripheral Zone? Radiology 275:448–457CrossRefPubMed
30.
Zurück zum Zitat Isebaert S, De Keyzer F, Haustermans K et al (2012) Evaluation of semi-quantitative dynamic contrast-enhanced MRI parameters for prostate cancer in correlation to whole-mount histopathology. Eur J Radiol 81:e217–e222CrossRefPubMed Isebaert S, De Keyzer F, Haustermans K et al (2012) Evaluation of semi-quantitative dynamic contrast-enhanced MRI parameters for prostate cancer in correlation to whole-mount histopathology. Eur J Radiol 81:e217–e222CrossRefPubMed
31.
Zurück zum Zitat Vos EK, Litjens GJ, Kobus T et al (2013) Assessment of prostate cancer aggressiveness using dynamic contrast-enhanced magnetic resonance imaging at 3 T. Eur Urol 64:448–455CrossRefPubMed Vos EK, Litjens GJ, Kobus T et al (2013) Assessment of prostate cancer aggressiveness using dynamic contrast-enhanced magnetic resonance imaging at 3 T. Eur Urol 64:448–455CrossRefPubMed
32.
Zurück zum Zitat Morel DR, Schwieger I, Hohn L et al (2000) Human pharmacokinetics and safety evaluation of SonoVue, a new contrast agent for ultrasound imaging. Invest Radiol 35:80–85CrossRefPubMed Morel DR, Schwieger I, Hohn L et al (2000) Human pharmacokinetics and safety evaluation of SonoVue, a new contrast agent for ultrasound imaging. Invest Radiol 35:80–85CrossRefPubMed
33.
Zurück zum Zitat Aime S, Caravan P (2009) Biodistribution of gadolinium-based contrast agents, including gadolinium deposition. J Magn Reson Imaging 30:1259–1267CrossRefPubMedPubMedCentral Aime S, Caravan P (2009) Biodistribution of gadolinium-based contrast agents, including gadolinium deposition. J Magn Reson Imaging 30:1259–1267CrossRefPubMedPubMedCentral
34.
Zurück zum Zitat Bellin MF, Van Der Molen AJ (2008) Extracellular gadolinium-based contrast media: an overview. Eur J Radiol 66:160–167CrossRefPubMed Bellin MF, Van Der Molen AJ (2008) Extracellular gadolinium-based contrast media: an overview. Eur J Radiol 66:160–167CrossRefPubMed
35.
Zurück zum Zitat Zink F, Kratzer W, Schmidt S et al (2016) Comparison of Two High-End Ultrasound Systems for Contrast-Enhanced Ultrasound Quantification of Mural Microvascularity in Crohn's Disease. Ultraschall Med 37:74–81PubMed Zink F, Kratzer W, Schmidt S et al (2016) Comparison of Two High-End Ultrasound Systems for Contrast-Enhanced Ultrasound Quantification of Mural Microvascularity in Crohn's Disease. Ultraschall Med 37:74–81PubMed
36.
Zurück zum Zitat Westhoff N, Siegel FP, Hausmann D et al (2017) Precision of MRI/ultrasound-fusion biopsy in prostate cancer diagnosis: an ex vivo comparison of alternative biopsy techniques on prostate phantoms. World J Urol 35:1015–1022CrossRefPubMed Westhoff N, Siegel FP, Hausmann D et al (2017) Precision of MRI/ultrasound-fusion biopsy in prostate cancer diagnosis: an ex vivo comparison of alternative biopsy techniques on prostate phantoms. World J Urol 35:1015–1022CrossRefPubMed
Metadaten
Titel
A direct comparison of contrast-enhanced ultrasound and dynamic contrast-enhanced magnetic resonance imaging for prostate cancer detection and prediction of aggressiveness
verfasst von
Alexander D. J. Baur
Julia Schwabe
Julian Rogasch
Andreas Maxeiner
Tobias Penzkofer
Carsten Stephan
Marc Rudl
Bernd Hamm
Ernst-Michael Jung
Thom Fischer
Publikationsdatum
13.12.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 5/2018
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-017-5192-2

Weitere Artikel der Ausgabe 5/2018

European Radiology 5/2018 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.