Skip to main content
Erschienen in: Journal of Digital Imaging 3/2010

01.06.2010

A Multistage Registration Method Using Texture Features

verfasst von: Andreja Jarc, Janez Perš, Stanislav Kovačič

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 3/2010

Einloggen, um Zugang zu erhalten

Abstract

We present a novel, multistage registration method based on Laws’ texture features. In general, a large number of texture features may be extracted from the original intensity images. For each of the texture features, a criterion function that measures the similarity between the images may be derived. The proposed registration method consists of two major steps. In the first step, a dataset of images with the corresponding gold standard is used. In this step, the selection and ranking of the texture features for registration is made. The selection and ranking of the features is based on their robustness, accuracy, and capture range. The selected features are then entered in the second step, where the actual registration is performed using a sequence of registration stages. Our method is based on the selection of the most robust feature for the first registration stage and the selection of accurate feature(s) for the subsequent stages. The texture features are daisy-chained so that the accuracy of the previous feature is sufficient for the capture range of the next feature. We tested our method on 11 2D image pairs containing digital reconstructed radiographs and electron portal imaging modalities, which were difficult to register using intensity features alone. With our method, we have successfully registered 75% of the initial displacements, ranging from 5 to 7.5 mm, with the target-registration error below 3 mm, whereas the traditional intensity-based approach delivered only 15% successfully registered cases.
Fußnoten
1
The figure is reproduced from.22
 
Literatur
1.
Zurück zum Zitat Van den Elsen PA, Maintz BA, Pol EJD, Viergever MA: Automatic registration of CT and MR brain images using correlation of geometrical features. IEEE Trans Med Imaging 14(2):384–396, 1995CrossRefPubMed Van den Elsen PA, Maintz BA, Pol EJD, Viergever MA: Automatic registration of CT and MR brain images using correlation of geometrical features. IEEE Trans Med Imaging 14(2):384–396, 1995CrossRefPubMed
2.
Zurück zum Zitat Maintz A, Viergever MA: A survey of medical image registration. Med Image Anal 2(1):1–36, 1998CrossRefPubMed Maintz A, Viergever MA: A survey of medical image registration. Med Image Anal 2(1):1–36, 1998CrossRefPubMed
3.
Zurück zum Zitat Lester H, Arridge SR: A survey of hierarchical non-linear medical image registration. Pattern Recogn 32(1):129–149, 1999CrossRef Lester H, Arridge SR: A survey of hierarchical non-linear medical image registration. Pattern Recogn 32(1):129–149, 1999CrossRef
4.
Zurück zum Zitat Hill DLG, Batchelor PG, Holden M, Hawkes DJ: Medical image registration. Phys Med Biol 46:1–45, 2001CrossRef Hill DLG, Batchelor PG, Holden M, Hawkes DJ: Medical image registration. Phys Med Biol 46:1–45, 2001CrossRef
5.
Zurück zum Zitat Pluim JP, Maintz BA, Viergever MA: Mutual information based registration of medical images: a survey. IEEE Trans Med Imaging 22(8):986–1004, 2003CrossRefPubMed Pluim JP, Maintz BA, Viergever MA: Mutual information based registration of medical images: a survey. IEEE Trans Med Imaging 22(8):986–1004, 2003CrossRefPubMed
6.
Zurück zum Zitat Zitova B, Flusser J: Image registration methods: a survey. Image Vision Comput 21(11):977–1000, 2003CrossRef Zitova B, Flusser J: Image registration methods: a survey. Image Vision Comput 21(11):977–1000, 2003CrossRef
7.
Zurück zum Zitat Gholipour A, Kehtarnavaz N, Briggs R, Devous M, Gopinath K: Brain functional localization: A survey of image registration techniques. IEEE Trans Med Imaging 26(4):427–451, 2007CrossRefPubMed Gholipour A, Kehtarnavaz N, Briggs R, Devous M, Gopinath K: Brain functional localization: A survey of image registration techniques. IEEE Trans Med Imaging 26(4):427–451, 2007CrossRefPubMed
8.
Zurück zum Zitat Jarc A, Rogelj P, Kovačič S: Texture feature based image registration. In Symposium proceedings Biomedical imaging: From Nano to Macro, IEEE ISBI, 17–20, 2007 Jarc A, Rogelj P, Kovačič S: Texture feature based image registration. In Symposium proceedings Biomedical imaging: From Nano to Macro, IEEE ISBI, 17–20, 2007
9.
Zurück zum Zitat Maurer CR, Aboutanos GB, Dawant BM, Maciunas RJ, Fitzpatrick JM: Registration of 3-D images using weighted geometrical features. IEEE Trans Med Imaging 15(6):836–850, 1996CrossRefPubMed Maurer CR, Aboutanos GB, Dawant BM, Maciunas RJ, Fitzpatrick JM: Registration of 3-D images using weighted geometrical features. IEEE Trans Med Imaging 15(6):836–850, 1996CrossRefPubMed
10.
Zurück zum Zitat Likar B, Pernuš F: Automatic extraction of corresponding points for the registration of medical images. Med Phys 26(8):1678–1686, 1999CrossRefPubMed Likar B, Pernuš F: Automatic extraction of corresponding points for the registration of medical images. Med Phys 26(8):1678–1686, 1999CrossRefPubMed
11.
Zurück zum Zitat Pennec X, Ayache N, Thirion JP: Landmark-based registration using features identified through differential geometry. Orlando: Academic Press, 2000 Pennec X, Ayache N, Thirion JP: Landmark-based registration using features identified through differential geometry. Orlando: Academic Press, 2000
12.
Zurück zum Zitat Viola P, Wells WM: Alignment by maximization of mutual information. Int J Comput Vision 24(2):137–154, 1997CrossRef Viola P, Wells WM: Alignment by maximization of mutual information. Int J Comput Vision 24(2):137–154, 1997CrossRef
13.
Zurück zum Zitat Rousseau F, Fablet R, Barillot C: Robust statistical registration of 3D ultrasound images using texture information. IEEE International Conference on Image Processing (ICIP) 1:581–584, 2003 Rousseau F, Fablet R, Barillot C: Robust statistical registration of 3D ultrasound images using texture information. IEEE International Conference on Image Processing (ICIP) 1:581–584, 2003
14.
Zurück zum Zitat Pratikakis I, Barillot C, Hellier P: Robust multiscale non-rigid registration of 3-D ultrasound images. In Int. Conf. on Scale-Space and Morphology in Computer Vision, Springer-Verlag, 389–397, 2001 Pratikakis I, Barillot C, Hellier P: Robust multiscale non-rigid registration of 3-D ultrasound images. In Int. Conf. on Scale-Space and Morphology in Computer Vision, Springer-Verlag, 389–397, 2001
15.
Zurück zum Zitat Jarc A, Rogelj P, Kovačič S: Analysis of texture features for registration of DRR and EPI images. Int J Comput Assisted Radiol Surg 2(Supplement 1):116–118, 2007 Jarc A, Rogelj P, Kovačič S: Analysis of texture features for registration of DRR and EPI images. Int J Comput Assisted Radiol Surg 2(Supplement 1):116–118, 2007
16.
Zurück zum Zitat Pluim JP, Maintz BA, Viergever MA: Image registration by maximization of combined mutual information and gradient information. IEEE Trans Med Imaging 19(8):809–814, 2000CrossRefPubMed Pluim JP, Maintz BA, Viergever MA: Image registration by maximization of combined mutual information and gradient information. IEEE Trans Med Imaging 19(8):809–814, 2000CrossRefPubMed
17.
Zurück zum Zitat Maintz BA, Van den Elsen PA, Viergever MA: Comparison of edge-based and ridge-based registration of CT and MR brain images. Med Image Anal 1(2):151–161, 1996CrossRefPubMed Maintz BA, Van den Elsen PA, Viergever MA: Comparison of edge-based and ridge-based registration of CT and MR brain images. Med Image Anal 1(2):151–161, 1996CrossRefPubMed
18.
Zurück zum Zitat Hsu LY, Loew MH: Fully automatic 3-D feature-based registration of multi-modality medical images. Image Vision Comput 19(1):75–85, 2001CrossRef Hsu LY, Loew MH: Fully automatic 3-D feature-based registration of multi-modality medical images. Image Vision Comput 19(1):75–85, 2001CrossRef
19.
Zurück zum Zitat Liu J, Vemuri BC, Marroquin JL: Local frequency representations for robust multimodal image registration. IEEE Trans Med Imaging 21(5):462–469, 2002CrossRefPubMed Liu J, Vemuri BC, Marroquin JL: Local frequency representations for robust multimodal image registration. IEEE Trans Med Imaging 21(5):462–469, 2002CrossRefPubMed
20.
Zurück zum Zitat Haber E, Modersitzki J: Intensity gradient based registration and fusion of multi-modal images. In Med Image Comput Comput-Assisted Intervention-MICCAI, Springer-Verlag:726–733, 2006 Haber E, Modersitzki J: Intensity gradient based registration and fusion of multi-modal images. In Med Image Comput Comput-Assisted Intervention-MICCAI, Springer-Verlag:726–733, 2006
21.
Zurück zum Zitat Liu J, Tian J: Registration of brain MRI/PET images based on adaptive combination of intensity and gradient mutual information. Int J Biomed Imaging 2007:1–10, 2007 (ID 93479)CrossRef Liu J, Tian J: Registration of brain MRI/PET images based on adaptive combination of intensity and gradient mutual information. Int J Biomed Imaging 2007:1–10, 2007 (ID 93479)CrossRef
22.
Zurück zum Zitat Škerl D, Likar B, Pernuš F: A protocol for evaluation of similarity measures for rigid registration. IEEE Trans Med Imaging 25(6):779–791, 2006CrossRefPubMed Škerl D, Likar B, Pernuš F: A protocol for evaluation of similarity measures for rigid registration. IEEE Trans Med Imaging 25(6):779–791, 2006CrossRefPubMed
23.
Zurück zum Zitat Reinstein LE, Amols HI, Biggs PJ, Droege RT, Filimonov AB, Lutz WR, Shalev S: Radiotherapy portal imaging quality. Published for the American Association of Physicists in Medicine by the American Institute of Physics, Report of AAPM task group No. 28, 1987 Reinstein LE, Amols HI, Biggs PJ, Droege RT, Filimonov AB, Lutz WR, Shalev S: Radiotherapy portal imaging quality. Published for the American Association of Physicists in Medicine by the American Institute of Physics, Report of AAPM task group No. 28, 1987
24.
Zurück zum Zitat Škerl D, Tomaževič D, Likar B, Pernuš F: Evaluation of similarity measures for reconstruction-based registration in image-guided radiotherapy and surgery. Int J Radiat Oncol Biol Phys 65(3):943–953, 2006PubMed Škerl D, Tomaževič D, Likar B, Pernuš F: Evaluation of similarity measures for reconstruction-based registration in image-guided radiotherapy and surgery. Int J Radiat Oncol Biol Phys 65(3):943–953, 2006PubMed
25.
Zurück zum Zitat Škerl D, Likar B, Fitzpatrick JM, Pernuš F: Comparative evaluation of similarity measures for the rigid registration of multi-modal head images. Phys Med Biol 52:5587–5601, 2007CrossRefPubMed Škerl D, Likar B, Fitzpatrick JM, Pernuš F: Comparative evaluation of similarity measures for the rigid registration of multi-modal head images. Phys Med Biol 52:5587–5601, 2007CrossRefPubMed
26.
Zurück zum Zitat Jarc A, Perš J, Rogelj P, Kovačič S: Efficient sampling for the evaluation protocol for 2-D rigid registration. Informacije MIDEM in press, 2009 Jarc A, Perš J, Rogelj P, Kovačič S: Efficient sampling for the evaluation protocol for 2-D rigid registration. Informacije MIDEM in press, 2009
27.
Zurück zum Zitat Laws K: Rapid texture identification. SPIE Image Processing for Missile Guidance; Proceedings of the Seminar, San Diego, 376–380, 1980 Laws K: Rapid texture identification. SPIE Image Processing for Missile Guidance; Proceedings of the Seminar, San Diego, 376–380, 1980
28.
Zurück zum Zitat Petrou M, Sevilla PG: Image Processing: Dealing with Texture. Hoboken: Willey, 2006 Petrou M, Sevilla PG: Image Processing: Dealing with Texture. Hoboken: Willey, 2006
29.
Zurück zum Zitat Press WH, Flannery BP, Teukolsky SA, Vetterling WT: Numerical Recipes in C: The Art of Scientific Computing, 2nd edition. Cambridge: Cambridge University Press, 1996 Press WH, Flannery BP, Teukolsky SA, Vetterling WT: Numerical Recipes in C: The Art of Scientific Computing, 2nd edition. Cambridge: Cambridge University Press, 1996
30.
Zurück zum Zitat Dong L, Boyer A: An image correlation procedure for digitally reconstructed radiographs and electronic portal images. Int J Radiat Oncol Biol Phys 33(5):1053–1060, 1995PubMed Dong L, Boyer A: An image correlation procedure for digitally reconstructed radiographs and electronic portal images. Int J Radiat Oncol Biol Phys 33(5):1053–1060, 1995PubMed
31.
Zurück zum Zitat Matsopoulos G, Asvestas P, Delibasis K, Kouloulias V, Uzunoglu N, Karaiskos P, Sandilos P: Registration of electronic portal images for patient set-up verification. Phys Med Biol 49:3279–3289, 2004CrossRefPubMed Matsopoulos G, Asvestas P, Delibasis K, Kouloulias V, Uzunoglu N, Karaiskos P, Sandilos P: Registration of electronic portal images for patient set-up verification. Phys Med Biol 49:3279–3289, 2004CrossRefPubMed
32.
Zurück zum Zitat Bachman KA: Mutual information-based registration of digitally reconstructed radiographs and electronic portal images. Master’s thesis, Applied Mathematics, University of Colorado at Denver, 2005 Bachman KA: Mutual information-based registration of digitally reconstructed radiographs and electronic portal images. Master’s thesis, Applied Mathematics, University of Colorado at Denver, 2005
33.
Zurück zum Zitat Khamene A, Bloch P, Wein W, Svatos M, Sauer F: Automatic registration of portal images and volumetric CT for patient positioning in radiation therapy. Med Image Anal 10:96–112, 2006CrossRefPubMed Khamene A, Bloch P, Wein W, Svatos M, Sauer F: Automatic registration of portal images and volumetric CT for patient positioning in radiation therapy. Med Image Anal 10:96–112, 2006CrossRefPubMed
34.
Zurück zum Zitat Ureten O, Erkal HS: Measurement of patient setup errors using digitally reconstructed radiographs and electronic portal images. Biomedical Engineering Days, Proceedings of the 1998 2nd International Conference 88–90, 1998 Ureten O, Erkal HS: Measurement of patient setup errors using digitally reconstructed radiographs and electronic portal images. Biomedical Engineering Days, Proceedings of the 1998 2nd International Conference 88–90, 1998
Metadaten
Titel
A Multistage Registration Method Using Texture Features
verfasst von
Andreja Jarc
Janez Perš
Stanislav Kovačič
Publikationsdatum
01.06.2010
Verlag
Springer-Verlag
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 3/2010
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-009-9175-y

Weitere Artikel der Ausgabe 3/2010

Journal of Digital Imaging 3/2010 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.