Skip to main content
Erschienen in: CardioVascular and Interventional Radiology 6/2011

01.12.2011 | Technical Note

A Novel Fenestration Technique for Abdominal Aortic Dissection Membranes Using a Combination of a Needle Re-entry Catheter and the “Cheese-wire” Technique

verfasst von: Sebastian Kos, Lorenz Gürke, Augustinus L. Jacob

Erschienen in: CardioVascular and Interventional Radiology | Ausgabe 6/2011

Einloggen, um Zugang zu erhalten

Abstract

Purpose

This study was designed to demonstrate the applicability of a combined needle-based re-entry catheter and “cheese-wire” technique for fenestration of abdominal aortic dissection membranes.

Methods

Four male patients (mean age: 65 years) with acute complicated aortic type B dissections were treated at our institution by fenestrating the abdominal aortic dissection membrane using a hybrid technique. This technique combined an initial membrane puncture with a needle-based re-entry catheter using a transfemoral approach. A guidewire was passed through the re-entry catheter and across the membrane. Using a contralateral transfemoral access, this guidewire was then snared, creating a through-and-through wire access. The membrane was then fenestrated using the cheese-wire maneuver.

Results

We successfully performed: (a) membrane puncture; (b) guidewire passage; (c) guidewire snaring; and (d) cheese-wire maneuver in all four cases. After this maneuver, decompression of the false lumen and acceptable arterial inflow into the true lumen was observed in all cases. The dependent visceral arteries were reperfused. In one case, portions of the fenestrated membrane occluded the common iliac artery, which was immediately and successfully stented. In another case, long-standing intestinal hypoperfusion before the fenestration resulted in reperfusion-related shock and intraoperative death of the patient.

Conclusions

The described hybrid approach for fenestration of dissection membranes is technically feasible and may be established as a therapeutic method in cases with a complicated type B dissection.
Literatur
1.
Zurück zum Zitat Beregi JP, Haulon S, Otal P et al (2003) Endovascular treatment of acute complications associated with aortic dissection: midterm results from a multicenter study. J Endovasc Ther 10:486–493PubMedCrossRef Beregi JP, Haulon S, Otal P et al (2003) Endovascular treatment of acute complications associated with aortic dissection: midterm results from a multicenter study. J Endovasc Ther 10:486–493PubMedCrossRef
2.
Zurück zum Zitat Williams DM, Brothers TE, Messina LM (1990) Relief of mesenteric ischemia in type III aortic dissection with percutaneous fenestration of the aortic septum. Radiology 174:450–452PubMed Williams DM, Brothers TE, Messina LM (1990) Relief of mesenteric ischemia in type III aortic dissection with percutaneous fenestration of the aortic septum. Radiology 174:450–452PubMed
3.
Zurück zum Zitat Williams DM, Lee DY, Hamilton BH et al (1997) The dissected aorta: percutaneous treatment of ischemic complications—principles and results. J Vasc Interv Radiol 8:605–625PubMedCrossRef Williams DM, Lee DY, Hamilton BH et al (1997) The dissected aorta: percutaneous treatment of ischemic complications—principles and results. J Vasc Interv Radiol 8:605–625PubMedCrossRef
4.
Zurück zum Zitat Chavan A, Hausmann D, Dresler C et al (1997) Intravascular ultrasound-guided percutaneous fenestration of the intimal flap in the dissected aorta. Circulation 96:2124–2127PubMed Chavan A, Hausmann D, Dresler C et al (1997) Intravascular ultrasound-guided percutaneous fenestration of the intimal flap in the dissected aorta. Circulation 96:2124–2127PubMed
5.
Zurück zum Zitat Hausegger KA, Georgieva B, Portugaller H et al (2004) The outback catheter: a new device for true lumen re-entry after dissection during recanalization of arterial occlusions. Cardiovasc Interv Radiol 27:26–30CrossRef Hausegger KA, Georgieva B, Portugaller H et al (2004) The outback catheter: a new device for true lumen re-entry after dissection during recanalization of arterial occlusions. Cardiovasc Interv Radiol 27:26–30CrossRef
6.
Zurück zum Zitat Jacobs DL, Motaganahalli RL, Cox DE et al (2006) True lumen re-entry devices facilitate subintimal angioplasty and stenting of total chronic occlusions: initial report. J Vasc Surg 43:1291–1296PubMedCrossRef Jacobs DL, Motaganahalli RL, Cox DE et al (2006) True lumen re-entry devices facilitate subintimal angioplasty and stenting of total chronic occlusions: initial report. J Vasc Surg 43:1291–1296PubMedCrossRef
7.
Zurück zum Zitat Ramjas G, Thurley P, Habib S (2008) The use of a re-entry catheter in recanalization of chronic inflow occlusions of the common iliac artery. Cardiovasc Interv Radiol 31:650–654CrossRef Ramjas G, Thurley P, Habib S (2008) The use of a re-entry catheter in recanalization of chronic inflow occlusions of the common iliac artery. Cardiovasc Interv Radiol 31:650–654CrossRef
8.
Zurück zum Zitat Kickuth R, Ludwig KC, Do DD et al (2006) Guidance of interventions in subintimal recanalization and fenestration of dissection membranes using a novel dual-lumen intravascular ultrasound catheter. Rofo 178:898–905PubMedCrossRef Kickuth R, Ludwig KC, Do DD et al (2006) Guidance of interventions in subintimal recanalization and fenestration of dissection membranes using a novel dual-lumen intravascular ultrasound catheter. Rofo 178:898–905PubMedCrossRef
9.
Zurück zum Zitat Wuest W, Goltz J, Ritter C et al. (2009) Fenestration of aortic dissection using a fluoroscopy-based needle re-entry catheter system. Cardiovasc Intervent Radiol. doi:10.1007/s00270-009-9783-4) Wuest W, Goltz J, Ritter C et al. (2009) Fenestration of aortic dissection using a fluoroscopy-based needle re-entry catheter system. Cardiovasc Intervent Radiol. doi:10.​1007/​s00270-009-9783-4)
10.
Zurück zum Zitat Watkinson AF (2009) A novel “cheese wire” technique for stent positioning following difficult iliac artery subintimal dissection and aortic re-entry. Cardiovasc Interv Radiol 32:781–784CrossRef Watkinson AF (2009) A novel “cheese wire” technique for stent positioning following difficult iliac artery subintimal dissection and aortic re-entry. Cardiovasc Interv Radiol 32:781–784CrossRef
11.
Zurück zum Zitat Jacob AL, Regazzoni P, Bilecen D et al (2007) Medical technology integration: CT, angiography, imaging-capable OR-table, navigation and robotics in a multifunctional sterile suite. Minim Invasive Ther Allied Technol 16:205–211PubMedCrossRef Jacob AL, Regazzoni P, Bilecen D et al (2007) Medical technology integration: CT, angiography, imaging-capable OR-table, navigation and robotics in a multifunctional sterile suite. Minim Invasive Ther Allied Technol 16:205–211PubMedCrossRef
12.
Zurück zum Zitat Slonim SM, Miller DC, Mitchell RS et al (1999) Percutaneous balloon fenestration and stenting for life-threatening ischemic complications in patients with acute aortic dissection. J Thorac Cardiovasc Surg 117:1118–1126PubMedCrossRef Slonim SM, Miller DC, Mitchell RS et al (1999) Percutaneous balloon fenestration and stenting for life-threatening ischemic complications in patients with acute aortic dissection. J Thorac Cardiovasc Surg 117:1118–1126PubMedCrossRef
13.
Zurück zum Zitat Chavan A, Rosenthal H, Luthe L et al (2009) Percutaneous interventions for treating ischemic complications of aortic dissection. Eur Radiol 19:488–494PubMedCrossRef Chavan A, Rosenthal H, Luthe L et al (2009) Percutaneous interventions for treating ischemic complications of aortic dissection. Eur Radiol 19:488–494PubMedCrossRef
14.
Zurück zum Zitat Husmann MJ, Kickuth R, Ludwig K et al (2006) Intravascular ultrasound-guided creation of re-entry sites to improve intermittent claudication in patients with aortic dissection. J Endovasc Ther 13:424–428PubMedCrossRef Husmann MJ, Kickuth R, Ludwig K et al (2006) Intravascular ultrasound-guided creation of re-entry sites to improve intermittent claudication in patients with aortic dissection. J Endovasc Ther 13:424–428PubMedCrossRef
15.
Zurück zum Zitat Chavan A, Lotz J, Oelert F et al (2003) Endoluminal treatment of aortic dissection. Eur Radiol 13:2521–2534PubMedCrossRef Chavan A, Lotz J, Oelert F et al (2003) Endoluminal treatment of aortic dissection. Eur Radiol 13:2521–2534PubMedCrossRef
Metadaten
Titel
A Novel Fenestration Technique for Abdominal Aortic Dissection Membranes Using a Combination of a Needle Re-entry Catheter and the “Cheese-wire” Technique
verfasst von
Sebastian Kos
Lorenz Gürke
Augustinus L. Jacob
Publikationsdatum
01.12.2011
Verlag
Springer-Verlag
Erschienen in
CardioVascular and Interventional Radiology / Ausgabe 6/2011
Print ISSN: 0174-1551
Elektronische ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-011-0110-5

Weitere Artikel der Ausgabe 6/2011

CardioVascular and Interventional Radiology 6/2011 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.