Abstract

This study evaluated a method to maintain the optimal image quality in clinical practice for image quality management in a picture archiving and communication system (PACS) that uses typical technology for digital medical images. This study conducted a survey of 25 hospitals in Seoul and metropolitan areas that had installed PACS to examine the reality of image quality management. Sixteen diagnostic monitors were used as calibration tools to compare and analyze the external illuminance uniformity and grayscale standard display function (GSDF) values at each frequency. According to the survey results, most of the hospitals did not have any particular rules or standardized methods for image quality control. In a PACS, the calibration frequency was examined within the allowable limits of error for each week and month. The calibration was not affected by the difference in brightness of the environment for reading an image. The GSDF measurement values were quite different from the standard values. In conclusion, to improve the image quality of the digital system, it is important to make good use of the system and maintain the image quality. Therefore, it is critical to capitalize on the method suggested in this study and maintain the optimal image quality to guarantee a high level of observer satisfaction.
Literatur
1.
Zurück zum Zitat Digital Imaging and Communications in Medicine (DICOM): Base Standard. National Electrical Manufacturers Association. Rosslyn, VA, USA. 2008 Digital Imaging and Communications in Medicine (DICOM): Base Standard. National Electrical Manufacturers Association. Rosslyn, VA, USA. 2008
2.
Zurück zum Zitat Fujita H, Ueda K, Morishita J: Basic imaging properties of a computed radiographic system with photostimulable phosphors. Med Phys 16:52–59, 1989PubMedCrossRef Fujita H, Ueda K, Morishita J: Basic imaging properties of a computed radiographic system with photostimulable phosphors. Med Phys 16:52–59, 1989PubMedCrossRef
3.
Zurück zum Zitat Axelsson B, Boden K, Fransson S: A comparison of analogue and digital techniques in upper gastrointestinal examinations: absorbed dose and diagnostic quality of the images. Eur Radiol 10:1351–1354, 2000PubMedCrossRef Axelsson B, Boden K, Fransson S: A comparison of analogue and digital techniques in upper gastrointestinal examinations: absorbed dose and diagnostic quality of the images. Eur Radiol 10:1351–1354, 2000PubMedCrossRef
4.
Zurück zum Zitat Park YH: Consideration about medical treatment’s utility through input of image. J Korean Soc Picture Archiving Commun Syst 10:125–132, 2004 Park YH: Consideration about medical treatment’s utility through input of image. J Korean Soc Picture Archiving Commun Syst 10:125–132, 2004
5.
Zurück zum Zitat Shin MJ, Song KS, Auh YH, Lim KT, Lee JH, Lee SH: PACS development in Asan medical center. KMIAA 3:1–3, 1997 Shin MJ, Song KS, Auh YH, Lim KT, Lee JH, Lee SH: PACS development in Asan medical center. KMIAA 3:1–3, 1997
6.
Zurück zum Zitat Ro DW, Kim BH, Choo SW, Lee WJ, Lee KS, Kim BK: Status of full PACS at Sammung medical center. KMIAA 4:1–4, 1998 Ro DW, Kim BH, Choo SW, Lee WJ, Lee KS, Kim BK: Status of full PACS at Sammung medical center. KMIAA 4:1–4, 1998
7.
Zurück zum Zitat Bramble JM, Huang HK, Murphy MD: Image data compression. Invest Radiol 23:707–712, 1998CrossRef Bramble JM, Huang HK, Murphy MD: Image data compression. Invest Radiol 23:707–712, 1998CrossRef
8.
Zurück zum Zitat Crochiere RE, Oppenheim AV, Dudgeon DE, Mersereau RM, Portnoff MR, Tribolet JM, Zue VW, Allen J: Digit Signal Proc RLE Prog Rep 112:79–82, 1974 Crochiere RE, Oppenheim AV, Dudgeon DE, Mersereau RM, Portnoff MR, Tribolet JM, Zue VW, Allen J: Digit Signal Proc RLE Prog Rep 112:79–82, 1974
9.
Zurück zum Zitat Huh YJ, Jeon IS, Heo MS, Lee SS, Choi SC, Park TW, Kim JD: A comparative study on the accuracy of digital subtraction radiography according to the acquisition methods of reconstructed images. Korean J Oral Maxillofac Radiol 32:107–111, 2002 Huh YJ, Jeon IS, Heo MS, Lee SS, Choi SC, Park TW, Kim JD: A comparative study on the accuracy of digital subtraction radiography according to the acquisition methods of reconstructed images. Korean J Oral Maxillofac Radiol 32:107–111, 2002
10.
Zurück zum Zitat Jones DM: Utilization of DICOM GSDF to modify lookup tables for images acquired on film digitizers. J Digit Imaging 19:167–171, 2006PubMedCrossRef Jones DM: Utilization of DICOM GSDF to modify lookup tables for images acquired on film digitizers. J Digit Imaging 19:167–171, 2006PubMedCrossRef
Metadaten
Titel
A Study on Image Quality Management in PACS Used by Korean Hospitals
verfasst von
Jae-Hwan Cho
Hae-Kag Lee
Kyung-Rae Dong
Woon-Kwan Chung
Publikationsdatum
01.12.2012
Verlag
Springer-Verlag
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 6/2012
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-012-9474-6

Weitere Artikel der Ausgabe 6/2012

Journal of Digital Imaging 6/2012 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.