Cortical bone trajectory (CBT) can facilitate both minimum invasiveness and strong screw fixation; however, ensuring the ideal cortical trajectory is challenging due to the narrow corridor, necessitating high-level surgical skill. A patient-specific template guide for CBT screw placement may be a promising solution to improve accuracy and safety. Little has been reported on the use of a CBT screw guide in clinical practice. The aim of the present study was to evaluate the accuracy of CBT screw placement using the template guide. This study was a retrospective clinical evaluation of prospectively collected patients. Forty-three consecutively enrolled patients who underwent posterior lumbar spinal fusion using the guide system were included. First, three-dimensional planning of CBT screw placement was performed using computer simulation software. The trajectory was directed in a more anterior position of the vertebral body, compared with the original CBT, and the standard size was set as 5–6 mm in diameter and 40–45 mm in length. Then, screw guides were created for each vertebra preoperatively and used. The safety and accuracy of a total of 198 inserted screws (L1 to L5) were analyzed using postoperative computed tomography by evaluation of pedicle perforation and measurement of screw deviations between the planned and actual screw positions. A total of 193 screws (97.5%) were placed completely inside the pedicle and there was no incidence of neurovascular injuries. The mean screw deviation from the planned trajectory on the coronal plane at the midpoint of the pedicle was 0.62 ± 0.42 mm, and the mean angular deviations in the sagittal and transverse planes were 1.68 ± 1.24° and 1.27 ± 0.77°, respectively. CBT screw placement using a patient-specific template guide was accurate enough for clinical application. This technique could be an effective solution to achieve both correct screw insertion and a reduction of complications.
Literatur
1.
Zurück zum Zitat Akpolat YT, İnceoğlu S, Kinne N, Hunt D, Cheng WK (2016) Fatigue performance of cortical bone trajectory screw compared with standard trajectory pedicle screw. Spine (Phila Pa 1976) 41:E335–E341CrossRef Akpolat YT, İnceoğlu S, Kinne N, Hunt D, Cheng WK (2016) Fatigue performance of cortical bone trajectory screw compared with standard trajectory pedicle screw. Spine (Phila Pa 1976) 41:E335–E341CrossRef
2.
Zurück zum Zitat Farshad M, Betz M, Farshad-Amacker NA, Moser M (2017) Accuracy of patient-specific template-guided vs. free-hand fluoroscopically controlled pedicle screw placement in the thoracic and lumbar spine: a randomized cadaveric study. Eur Spine J 26:738–749CrossRef Farshad M, Betz M, Farshad-Amacker NA, Moser M (2017) Accuracy of patient-specific template-guided vs. free-hand fluoroscopically controlled pedicle screw placement in the thoracic and lumbar spine: a randomized cadaveric study. Eur Spine J 26:738–749CrossRef
3.
Zurück zum Zitat He D, Yuan Q, Hu L, Tian W (2018) Robot assisted midline lumbar fusion with cortical bone trajectory screw. In: Zhan W, Rodriguez F, Baena Y (eds) CAOS 2018 (EPiC Series in Health Sciences) vol 2, pp 69–73 He D, Yuan Q, Hu L, Tian W (2018) Robot assisted midline lumbar fusion with cortical bone trajectory screw. In: Zhan W, Rodriguez F, Baena Y (eds) CAOS 2018 (EPiC Series in Health Sciences) vol 2, pp 69–73
4.
Zurück zum Zitat Hung CW, Wu MF, Hong RT, Weng MJ, Yu GF, Kao CH (2016) Comparison of multifidus muscle atrophy after posterior lumbar interbody fusion with conventional and cortical bone trajectory. Clin Neurol Neurosurg 145:41–45CrossRef Hung CW, Wu MF, Hong RT, Weng MJ, Yu GF, Kao CH (2016) Comparison of multifidus muscle atrophy after posterior lumbar interbody fusion with conventional and cortical bone trajectory. Clin Neurol Neurosurg 145:41–45CrossRef
5.
Zurück zum Zitat Ishikawa T, Aramomi M (2015) Assessment of CBT screw insertion for posterior lumbar interbody fusion. J Spine Res 6:1071–1075 Ishikawa T, Aramomi M (2015) Assessment of CBT screw insertion for posterior lumbar interbody fusion. J Spine Res 6:1071–1075
6.
Zurück zum Zitat Kaito T, Matsukawa K, Abe Y, Fiechter M, Zhu X, Fantigrossi A (2018) Cortical pedicle screw placement in lumbar spine surgery with a patient-matched targeting guide: a cadaveric study. J Orthop Sci 23:865–869CrossRef Kaito T, Matsukawa K, Abe Y, Fiechter M, Zhu X, Fantigrossi A (2018) Cortical pedicle screw placement in lumbar spine surgery with a patient-matched targeting guide: a cadaveric study. J Orthop Sci 23:865–869CrossRef
7.
Zurück zum Zitat Kim SB, Rhee JM, Lee GS, Lee HY, Kim T, Won Y (2018) Computer-assisted patient-specific prototype template for thoracolumbar cortical bone trajectory screw placement: a cadaveric study. Tech Orthop 33:246–250CrossRef Kim SB, Rhee JM, Lee GS, Lee HY, Kim T, Won Y (2018) Computer-assisted patient-specific prototype template for thoracolumbar cortical bone trajectory screw placement: a cadaveric study. Tech Orthop 33:246–250CrossRef
8.
Zurück zum Zitat Lamartina C, Cecchinato R, Fekete Z, Lipari A, Fiechter M, Berjano P (2015) Pedicle screw placement accuracy in thoracic and lumbar spinal surgery with a patient-matched targeting guide: a cadaveric study. Eur Spine J 24:937–941CrossRef Lamartina C, Cecchinato R, Fekete Z, Lipari A, Fiechter M, Berjano P (2015) Pedicle screw placement accuracy in thoracic and lumbar spinal surgery with a patient-matched targeting guide: a cadaveric study. Eur Spine J 24:937–941CrossRef
9.
Zurück zum Zitat Lee GW, Son JH, Ahn MW, Kim HJ, Yeom JS (2015) The comparison of pedicle screw and cortical screw in posterior lumbar interbody fusion: a prospective randomized noninferiority trial. Spine J 15:1519–1526CrossRef Lee GW, Son JH, Ahn MW, Kim HJ, Yeom JS (2015) The comparison of pedicle screw and cortical screw in posterior lumbar interbody fusion: a prospective randomized noninferiority trial. Spine J 15:1519–1526CrossRef
10.
Zurück zum Zitat Lu S, Xu YQ, Lu WW, Ni GX, Li YB, Shi JH, Li DP, Chen GP, Chen YB, Zhang YZ (2009) A novel patient-specific navigational template for cervical pedicle screw placement. Spine (Phila Pa 1976) 34:E959–E966CrossRef Lu S, Xu YQ, Lu WW, Ni GX, Li YB, Shi JH, Li DP, Chen GP, Chen YB, Zhang YZ (2009) A novel patient-specific navigational template for cervical pedicle screw placement. Spine (Phila Pa 1976) 34:E959–E966CrossRef
11.
Zurück zum Zitat Marengo N, Berjano P, Cofano F, Ajello M, Zenga F, Pilloni G, Penner F, Petrone S, Vay L, Ducati A, Garbossa D (2018) Cortical bone trajectory screws for circumferential arthrodesis in lumbar degenerative spine: clinical and radiological outcomes of 101 cases. Eur Spine J 27:213–221CrossRef Marengo N, Berjano P, Cofano F, Ajello M, Zenga F, Pilloni G, Penner F, Petrone S, Vay L, Ducati A, Garbossa D (2018) Cortical bone trajectory screws for circumferential arthrodesis in lumbar degenerative spine: clinical and radiological outcomes of 101 cases. Eur Spine J 27:213–221CrossRef
12.
Zurück zum Zitat Marengo N, Matsukawa K, Monticelli M, Ajello M, Pacca P, Cofano F, Penner F, Zenga F, Ducati A, Garbossa D (2019) Cortical bone trajectory screw placement accuracy with a patient-matched 3D printed guide in lumbar spinal surgery: a clinical study. World Neurosurg In press. https://doi.org/10.1016/j.wneu.2019.05.241 Marengo N, Matsukawa K, Monticelli M, Ajello M, Pacca P, Cofano F, Penner F, Zenga F, Ducati A, Garbossa D (2019) Cortical bone trajectory screw placement accuracy with a patient-matched 3D printed guide in lumbar spinal surgery: a clinical study. World Neurosurg In press. https://​doi.​org/​10.​1016/​j.​wneu.​2019.​05.​241
13.
Zurück zum Zitat Matsukawa K, Taguchi E, Yato Y, Imabayashi H, Hosogane N, Asazuma T, Nemoto K (2015) Evaluation of the fixation strength of pedicle screws using cortical bone trajectory: what is the ideal trajectory for optimal fixation? Spine (Phila Pa 1976) 40:E873–E878CrossRef Matsukawa K, Taguchi E, Yato Y, Imabayashi H, Hosogane N, Asazuma T, Nemoto K (2015) Evaluation of the fixation strength of pedicle screws using cortical bone trajectory: what is the ideal trajectory for optimal fixation? Spine (Phila Pa 1976) 40:E873–E878CrossRef
14.
Zurück zum Zitat Matsukawa K, Kato T, Yato Y, Sasao H, Imabayashi H, Hosogane N, Asazuma T, Chiba K (2016) Incidence and risk factors of adjacent cranial facet violation following pedicle screw insertion using cortical bone trajectory technique. Spine (Phila Pa 1976) 41:E851–E856CrossRef Matsukawa K, Kato T, Yato Y, Sasao H, Imabayashi H, Hosogane N, Asazuma T, Chiba K (2016) Incidence and risk factors of adjacent cranial facet violation following pedicle screw insertion using cortical bone trajectory technique. Spine (Phila Pa 1976) 41:E851–E856CrossRef
15.
Zurück zum Zitat Matsukawa K, Yato Y, Imabayashi H, Hosogane N, Abe Y, Asazuma T, Chiba K (2016) Biomechanical evaluation of fixation strength among different sizes of pedicle screws using the cortical bone trajectory: what is the ideal screw size for optimal fixation? Acta Neurochir 158:465–471CrossRef Matsukawa K, Yato Y, Imabayashi H, Hosogane N, Abe Y, Asazuma T, Chiba K (2016) Biomechanical evaluation of fixation strength among different sizes of pedicle screws using the cortical bone trajectory: what is the ideal screw size for optimal fixation? Acta Neurochir 158:465–471CrossRef
16.
Zurück zum Zitat McKinley TO, McLain RF, Yerby SA, Sharkey NA, Sarigul-Klijn N, Smith TS (1999) Characteristics of pedicle screw loading: effect of surgical technique on intravertebral and intrapedicular bending moments. Spine (Phila Pa 1976) 24:18–25CrossRef McKinley TO, McLain RF, Yerby SA, Sharkey NA, Sarigul-Klijn N, Smith TS (1999) Characteristics of pedicle screw loading: effect of surgical technique on intravertebral and intrapedicular bending moments. Spine (Phila Pa 1976) 24:18–25CrossRef
17.
Zurück zum Zitat Mobbs RJ (2013) The “medio-latero-superior trajectory technique”: an alternative cortical trajectory for pedicle fixation. Orthop Surg 5:56–59CrossRef Mobbs RJ (2013) The “medio-latero-superior trajectory technique”: an alternative cortical trajectory for pedicle fixation. Orthop Surg 5:56–59CrossRef
18.
Zurück zum Zitat Perez-Orribo L, Kalb S, Reyes PM, Chang SW, Crawford NR (2013) Biomechanics of lumbar cortical screw-rod fixation versus pedicle screw-rod fixation with and without interbody support. Spine (Phila Pa 1976) 38:635–641CrossRef Perez-Orribo L, Kalb S, Reyes PM, Chang SW, Crawford NR (2013) Biomechanics of lumbar cortical screw-rod fixation versus pedicle screw-rod fixation with and without interbody support. Spine (Phila Pa 1976) 38:635–641CrossRef
19.
Zurück zum Zitat Sakaura H, Miwa T, Yamashita T, Kuroda Y, Ohwada T (2016) Posterior lumbar interbody fusion with cortical bone trajectory screw fixation versus posterior lumbar interbody fusion using traditional pedicle screw fixation for degenerative lumbar spondylolisthesis: a comparative study. J Neurosurg Spine 25:591–595CrossRef Sakaura H, Miwa T, Yamashita T, Kuroda Y, Ohwada T (2016) Posterior lumbar interbody fusion with cortical bone trajectory screw fixation versus posterior lumbar interbody fusion using traditional pedicle screw fixation for degenerative lumbar spondylolisthesis: a comparative study. J Neurosurg Spine 25:591–595CrossRef
20.
Zurück zum Zitat Sakaura H, Ohnishi A, Yamagishi A, Ohwada T (2018) Early fusion status after posterior lumbar interbody fusion with cortical bone trajectory screw fixation: a comparison of titanium-coated polyetheretherketone cages and carbon polyetheretherketone cages. Asian Spine J. https://doi.org/10.31616/asj.2018.0169 Sakaura H, Ohnishi A, Yamagishi A, Ohwada T (2018) Early fusion status after posterior lumbar interbody fusion with cortical bone trajectory screw fixation: a comparison of titanium-coated polyetheretherketone cages and carbon polyetheretherketone cages. Asian Spine J. https://​doi.​org/​10.​31616/​asj.​2018.​0169
21.
Zurück zum Zitat Santoni BG, Hynes RA, McGilvary KC, Rodriguez-Canessa G, Lyons AS, Henson MA, Womack WJ, Puttlitz CM (2009) Cortical bone trajectory for lumbar pedicle screws. Spine J 9:366–373CrossRef Santoni BG, Hynes RA, McGilvary KC, Rodriguez-Canessa G, Lyons AS, Henson MA, Womack WJ, Puttlitz CM (2009) Cortical bone trajectory for lumbar pedicle screws. Spine J 9:366–373CrossRef
22.
Zurück zum Zitat Sugawara T, Higashiyama N, Kaneyama S, Takabatake M, Watanabe N, Uchida F, Sumi M, Mizoi K (2013) Multistep pedicle screw insertion procedure with patient-specific lamina fit-and-lock templates for the thoracic spine: clinical article. J Neurosurg Spine 19:185–190CrossRef Sugawara T, Higashiyama N, Kaneyama S, Takabatake M, Watanabe N, Uchida F, Sumi M, Mizoi K (2013) Multistep pedicle screw insertion procedure with patient-specific lamina fit-and-lock templates for the thoracic spine: clinical article. J Neurosurg Spine 19:185–190CrossRef
23.
Zurück zum Zitat Takemoto M, Fujibayashi S, Ota E, Otsuki B, Kimura H, Sakamoto T, Kawai T, Futami T, Sasaki K, Matsushita T, Nakamura T, Neo M, Matsuda S (2016) Additive-manufactured patient-specific titanium templates for thoracic pedicle screw placement: novel design with reduced contact area. Eur Spine J 25:1698–1705CrossRef Takemoto M, Fujibayashi S, Ota E, Otsuki B, Kimura H, Sakamoto T, Kawai T, Futami T, Sasaki K, Matsushita T, Nakamura T, Neo M, Matsuda S (2016) Additive-manufactured patient-specific titanium templates for thoracic pedicle screw placement: novel design with reduced contact area. Eur Spine J 25:1698–1705CrossRef
24.
Zurück zum Zitat Takenaka S, Mukai Y, Tateishi K, Hosono N, Fuji T, Kaito T (2017) Clinical outcomes after posterior lumbar interbody fusion: comparison of cortical bone trajectory and conventional pedicle screw insertion. Clin Spine Surg 30:E1411–E1418CrossRef Takenaka S, Mukai Y, Tateishi K, Hosono N, Fuji T, Kaito T (2017) Clinical outcomes after posterior lumbar interbody fusion: comparison of cortical bone trajectory and conventional pedicle screw insertion. Clin Spine Surg 30:E1411–E1418CrossRef
Metadaten
Titel
Accuracy of cortical bone trajectory screw placement using patient-specific template guide system
verfasst von
Keitaro Matsukawa
Takashi Kaito
Yuichiro Abe
Publikationsdatum
03.07.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
Neurosurgical Review / Ausgabe 4/2020
Print ISSN: 0344-5607
Elektronische ISSN: 1437-2320
DOI
https://doi.org/10.1007/s10143-019-01140-1

Weitere Artikel der Ausgabe 4/2020

Neurosurgical Review 4/2020 Zur Ausgabe

Vorsicht, erhöhte Blutungsgefahr nach PCI!

10.05.2024 Koronare Herzerkrankung Nachrichten

Nach PCI besteht ein erhöhtes Blutungsrisiko, wenn die Behandelten eine verminderte linksventrikuläre Ejektionsfraktion aufweisen. Das Risiko ist umso höher, je stärker die Pumpfunktion eingeschränkt ist.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Deutlich weniger Infektionen: Wundprotektoren schützen!

08.05.2024 Postoperative Wundinfektion Nachrichten

Der Einsatz von Wundprotektoren bei offenen Eingriffen am unteren Gastrointestinaltrakt schützt vor Infektionen im Op.-Gebiet – und dient darüber hinaus der besseren Sicht. Das bestätigt mit großer Robustheit eine randomisierte Studie im Fachblatt JAMA Surgery.

Chirurginnen und Chirurgen sind stark suizidgefährdet

07.05.2024 Suizid Nachrichten

Der belastende Arbeitsalltag wirkt sich negativ auf die psychische Gesundheit der Angehörigen ärztlicher Berufsgruppen aus. Chirurginnen und Chirurgen bilden da keine Ausnahme, im Gegenteil.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.