Skip to main content
Erschienen in: European Radiology 4/2006

01.04.2006 | Vascular-Interventional

Acquired diseases of the thoracic aorta: role of MRI and MRA

verfasst von: Vincenzo Russo, Matteo Renzulli, Katia Buttazzi, Rossella Fattori

Erschienen in: European Radiology | Ausgabe 4/2006

Einloggen, um Zugang zu erhalten

Abstract

Diseases of the thoracic aorta can present with a broad clinical spectrum of symptoms and signs. Their prevalence appears to be increasing in western populations, most likely corresponding to aging and heightened clinical awareness but also influenced by the progress of high-resolution, noninvasive imaging modalities. Among them, MRI provides an excellent visualization of vascular structures and is well suited for evaluation of thoracic aorta disease. Currently, in many centers, noninvasive imaging modalities are the first choice in the cardiovascular system evaluation and diagnosis, reserving conventional angiography for use only before therapeutic intervention. Understanding the principle MRA techniques is essential for acquiring consistent diagnostic images. Basic technical considerations, which include fast spin-echo, fast gradient-echo, and MRA techniques with phase contrast and contrast-enhanced methods, are discussed and applied in the evaluation of acquired thoracic aorta diseases.
Literatur
1.
Zurück zum Zitat Urban BA, Bluemke DA, Johnson KM, Fishman EK (1999) Imaging of thoracic aortic disease. Cardiol Clin 17(4):659–682PubMedCrossRef Urban BA, Bluemke DA, Johnson KM, Fishman EK (1999) Imaging of thoracic aortic disease. Cardiol Clin 17(4):659–682PubMedCrossRef
2.
Zurück zum Zitat Reddy GP, Higgins CB (2000) MR imaging of the thoracic aorta. Magn Reson Imaging Clin N Am 8(1):1–15PubMed Reddy GP, Higgins CB (2000) MR imaging of the thoracic aorta. Magn Reson Imaging Clin N Am 8(1):1–15PubMed
3.
Zurück zum Zitat Stemerman DH, Krinsky GA, Lee VS, Johnson G, Yang BM, Rofsky NM (1999) Thoracic aorta: rapid black-blood MR imaging with half-Fourier rapid acquisition with relaxation enhancement with or without electrocardiographic triggering. Radiology 213(1):185–191PubMed Stemerman DH, Krinsky GA, Lee VS, Johnson G, Yang BM, Rofsky NM (1999) Thoracic aorta: rapid black-blood MR imaging with half-Fourier rapid acquisition with relaxation enhancement with or without electrocardiographic triggering. Radiology 213(1):185–191PubMed
4.
Zurück zum Zitat Sakuma H, Bourne MW, O'Sullivan M et al (1996) Evaluation of thoracic aortic dissection using breath-holding Cine MRI. J Comput Assist Tomogr 20(1):45–50PubMedCrossRef Sakuma H, Bourne MW, O'Sullivan M et al (1996) Evaluation of thoracic aortic dissection using breath-holding Cine MRI. J Comput Assist Tomogr 20(1):45–50PubMedCrossRef
5.
Zurück zum Zitat Niezen RA, Doornbos J, van der Wall EE, de Roos A (1998) Measurement of aortic and pulmonary flow with MRI at rest and during physical exercise. J Comput Assist Tomogr 22(2):194–201PubMedCrossRef Niezen RA, Doornbos J, van der Wall EE, de Roos A (1998) Measurement of aortic and pulmonary flow with MRI at rest and during physical exercise. J Comput Assist Tomogr 22(2):194–201PubMedCrossRef
6.
Zurück zum Zitat Powell AJ, Maier SE, Chung T, Geva T (2000) Phase-velocity cine magnetic resonance imaging measurement of pulsatile blood flow in children and young adults: in vitro and in vivo validation. Pediatr Cardiol 21(2):104–110PubMedCrossRef Powell AJ, Maier SE, Chung T, Geva T (2000) Phase-velocity cine magnetic resonance imaging measurement of pulsatile blood flow in children and young adults: in vitro and in vivo validation. Pediatr Cardiol 21(2):104–110PubMedCrossRef
7.
Zurück zum Zitat Bogren HG, Buonocore MH (1999) 4D magnetic resonance velocity mapping of blood flow patterns in the aorta in young vs. elderly normal subjects. J Magn Reson Imaging 10(5):861–869PubMedCrossRef Bogren HG, Buonocore MH (1999) 4D magnetic resonance velocity mapping of blood flow patterns in the aorta in young vs. elderly normal subjects. J Magn Reson Imaging 10(5):861–869PubMedCrossRef
8.
Zurück zum Zitat Hopkins KD, Leheman ED, Gosling RG (1994) Aortic compliance measurements: a noninvasive indicator of atherosclerosis. Lancet 334:1447CrossRef Hopkins KD, Leheman ED, Gosling RG (1994) Aortic compliance measurements: a noninvasive indicator of atherosclerosis. Lancet 334:1447CrossRef
9.
Zurück zum Zitat Groenink M, de Roos A, Mulder BJM, Spaan JAE, van der Wall EE (1998) Changes in aortic distensibility and pulse wave velocity assessed with magnetic resonance imaging following beta-blockers therapy in the Marfan syndrome. Am J Cardiol 82:203–208PubMedCrossRef Groenink M, de Roos A, Mulder BJM, Spaan JAE, van der Wall EE (1998) Changes in aortic distensibility and pulse wave velocity assessed with magnetic resonance imaging following beta-blockers therapy in the Marfan syndrome. Am J Cardiol 82:203–208PubMedCrossRef
10.
Zurück zum Zitat Fattori R, Bacchi Reggiani L, Pepe G et al (2000) MRI evaluation of aortic elastic properties as early expression of Marfan Syndrome. J Cardiovasc Magn Reson 4:43–48 Fattori R, Bacchi Reggiani L, Pepe G et al (2000) MRI evaluation of aortic elastic properties as early expression of Marfan Syndrome. J Cardiovasc Magn Reson 4:43–48
11.
Zurück zum Zitat Debatin JF, Hany TF (1998) MR-based assessment of vascular morphology and function. Eur Radiol 8:528–539PubMedCrossRef Debatin JF, Hany TF (1998) MR-based assessment of vascular morphology and function. Eur Radiol 8:528–539PubMedCrossRef
12.
Zurück zum Zitat Sodickson DK, McKenzie CA, Li W, Wolff S, Manning WJ, Edelman RR (2000) Contrast-enhanced 3D MR angiography with simultaneous acquisition of spatial harmonics: a pilot study. Radiology 217(1):284–289PubMed Sodickson DK, McKenzie CA, Li W, Wolff S, Manning WJ, Edelman RR (2000) Contrast-enhanced 3D MR angiography with simultaneous acquisition of spatial harmonics: a pilot study. Radiology 217(1):284–289PubMed
13.
Zurück zum Zitat Lee VS, Martin DJ, Krinsky GA, Rofsky NM (2000) Gadolinium-enhanced MR angiography: artifacts and pitfalls. Am J Roentgenol 175:197–205 Lee VS, Martin DJ, Krinsky GA, Rofsky NM (2000) Gadolinium-enhanced MR angiography: artifacts and pitfalls. Am J Roentgenol 175:197–205
14.
Zurück zum Zitat Neimatallah MA, Ho VB, Dong Q et al (1999) Gadolinium-enhanced 3D Magnetic Resonance angiography of the thoracic vessels. JMRI 10:758–770PubMedCrossRef Neimatallah MA, Ho VB, Dong Q et al (1999) Gadolinium-enhanced 3D Magnetic Resonance angiography of the thoracic vessels. JMRI 10:758–770PubMedCrossRef
15.
Zurück zum Zitat Goyen M, Ruehm SG, Debatin JF (2000) MR-angiography: the role of contrast agents. Eur J Radiol 34(3):247–256PubMedCrossRef Goyen M, Ruehm SG, Debatin JF (2000) MR-angiography: the role of contrast agents. Eur J Radiol 34(3):247–256PubMedCrossRef
16.
Zurück zum Zitat Prince MR, Narasimham DL, Jacoby WT et al (1996) Three dimensional Gadolinium-enhanced MR angiography of the thoracic aorta. Am J Roentgenol 166:1387–1397 Prince MR, Narasimham DL, Jacoby WT et al (1996) Three dimensional Gadolinium-enhanced MR angiography of the thoracic aorta. Am J Roentgenol 166:1387–1397
17.
Zurück zum Zitat Krinsky G, Rofsky N, Flyer M et al (1996) Gadolinium-enhanced three dimensional MR angiography of acquired arch vessels disease. Am J Roentgenol 167:981–987 Krinsky G, Rofsky N, Flyer M et al (1996) Gadolinium-enhanced three dimensional MR angiography of acquired arch vessels disease. Am J Roentgenol 167:981–987
18.
Zurück zum Zitat Krinsky G, Rofsky N, De Corato DR et al (1997) Thoracic aorta: comparison of Gadolinium-enhanced three dimensional MR angiography with conventional MR imaging. Radiology 202:183–193PubMed Krinsky G, Rofsky N, De Corato DR et al (1997) Thoracic aorta: comparison of Gadolinium-enhanced three dimensional MR angiography with conventional MR imaging. Radiology 202:183–193PubMed
19.
Zurück zum Zitat Riederer SJ, Bernstein MA, Breen JF, Busse RF, Ehman RL, Fain SB, Hulshizer TC, Huston J III, King BF, Kruger DG, Rossman PJ, Shah S (2000) Three-dimensional contrast-enhanced MR angiography with real-time fluoroscopic triggering: design specifications and technical reliability in 330 patient studies. Radiology 215:584–593PubMed Riederer SJ, Bernstein MA, Breen JF, Busse RF, Ehman RL, Fain SB, Hulshizer TC, Huston J III, King BF, Kruger DG, Rossman PJ, Shah S (2000) Three-dimensional contrast-enhanced MR angiography with real-time fluoroscopic triggering: design specifications and technical reliability in 330 patient studies. Radiology 215:584–593PubMed
20.
Zurück zum Zitat Coady MA, Rizzo JA, Goldstein LJ, Elefteriades JA (1999) Natural history, pathogenesis and etiology of thoracic aneurysms and dissection. Card Clin North Am 17(4):615–633 Coady MA, Rizzo JA, Goldstein LJ, Elefteriades JA (1999) Natural history, pathogenesis and etiology of thoracic aneurysms and dissection. Card Clin North Am 17(4):615–633
21.
Zurück zum Zitat Bansal RC, Krishnaswamy C, Ayala K, Smith DC (1995) Frequency and explanation of false negative diagnosis of aortic dissection by aortography and transesophageal echocardiography. J Am Coll Cardiol 25:1393–401PubMedCrossRef Bansal RC, Krishnaswamy C, Ayala K, Smith DC (1995) Frequency and explanation of false negative diagnosis of aortic dissection by aortography and transesophageal echocardiography. J Am Coll Cardiol 25:1393–401PubMedCrossRef
22.
Zurück zum Zitat Spittel PC, Spittel JA, Joyce W et al (1993) Clinical features and differential diagnosis of aortic dissection: experience with 236 cases (1980 through 1990). Mayo Clin Proc 68:642–651 Spittel PC, Spittel JA, Joyce W et al (1993) Clinical features and differential diagnosis of aortic dissection: experience with 236 cases (1980 through 1990). Mayo Clin Proc 68:642–651
23.
Zurück zum Zitat Cigarroa JE, Isselbacher EM, De Sanctis RW, Eagle KA (1993) Diagnostic imaging in the evaluation of suspected aortic dissection: old standard and new direction. N Engl J Med 328:35–43PubMedCrossRef Cigarroa JE, Isselbacher EM, De Sanctis RW, Eagle KA (1993) Diagnostic imaging in the evaluation of suspected aortic dissection: old standard and new direction. N Engl J Med 328:35–43PubMedCrossRef
24.
Zurück zum Zitat Nienaber CA, Fattori R, Lund G, Dieckman C, Wolf W, Nikolas V, Pierangeli A (1999) Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement. N Eng J Med 140:1338–1345 Nienaber CA, Fattori R, Lund G, Dieckman C, Wolf W, Nikolas V, Pierangeli A (1999) Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement. N Eng J Med 140:1338–1345
25.
Zurück zum Zitat Dake MD, Kato N, Mitchell RS et al (1999) Endovascular stent-graft placement for the treatment of acute aortic dissection. N Engl J Med 140:1546–1552CrossRef Dake MD, Kato N, Mitchell RS et al (1999) Endovascular stent-graft placement for the treatment of acute aortic dissection. N Engl J Med 140:1546–1552CrossRef
26.
Zurück zum Zitat Nitatori T, Yokoyama K, Hachiya J, Yoshino A, Yamakami N, Katase S, Ichikawa T (1999) Fast dynamic MRI of aortic dissection: flow assessment by subsecondal imaging. Radiat Med 17(1):9–14PubMed Nitatori T, Yokoyama K, Hachiya J, Yoshino A, Yamakami N, Katase S, Ichikawa T (1999) Fast dynamic MRI of aortic dissection: flow assessment by subsecondal imaging. Radiat Med 17(1):9–14PubMed
27.
Zurück zum Zitat Chang JM, Friese K, Caputo GR, Kondo C, Higgins CB (1991) MR measurement of blood flow in the true and false channel in chronic aortic dissection. J Comput Assist Tomogr 15:418–423PubMedCrossRef Chang JM, Friese K, Caputo GR, Kondo C, Higgins CB (1991) MR measurement of blood flow in the true and false channel in chronic aortic dissection. J Comput Assist Tomogr 15:418–423PubMedCrossRef
28.
Zurück zum Zitat Fernandez GC, Tardaguila FM, Duran D, Trinidad C, Rodriguez M, Hortas M (2002) Dynamic 3-dimensional contrast-enhanced magnetic resonance angiography in acute aortic dissection. Curr Probl Diagn Radiol 31(4):134–145PubMedCrossRef Fernandez GC, Tardaguila FM, Duran D, Trinidad C, Rodriguez M, Hortas M (2002) Dynamic 3-dimensional contrast-enhanced magnetic resonance angiography in acute aortic dissection. Curr Probl Diagn Radiol 31(4):134–145PubMedCrossRef
29.
Zurück zum Zitat Bogaert J, Meyns B, Rademakers FE et al (1997) Follow-up of aortic dissection: contribution of MR angiography for evaluation of the abdominal aorta and its branches. Eur Radiol 7:695–702PubMed Bogaert J, Meyns B, Rademakers FE et al (1997) Follow-up of aortic dissection: contribution of MR angiography for evaluation of the abdominal aorta and its branches. Eur Radiol 7:695–702PubMed
30.
Zurück zum Zitat Nienaber CA, von Kodolitsch Y, Nikolas V et al (1993) The diagnosis of thoracic aortic dissection by noninvasive imaging procedures. N Engl J Med 328:1–9PubMedCrossRef Nienaber CA, von Kodolitsch Y, Nikolas V et al (1993) The diagnosis of thoracic aortic dissection by noninvasive imaging procedures. N Engl J Med 328:1–9PubMedCrossRef
31.
Zurück zum Zitat Sommer T, Fehske W, Holzknecht et al (1996) Aortic dissection: a comparative study of diagnosis with spiral CT, multiplanar transesophageal echocardiography and MR imaging. Radiology 199:347–352PubMed Sommer T, Fehske W, Holzknecht et al (1996) Aortic dissection: a comparative study of diagnosis with spiral CT, multiplanar transesophageal echocardiography and MR imaging. Radiology 199:347–352PubMed
32.
Zurück zum Zitat Fisher U, Vossherich R, Kopka L, Keating D, Oestmann J, Grabbe E (1994) Dissection of the thoracic aorta: pre- and postoperative findings of turbo-FLASH MR images in the plane of the aortic arch. Am J Roentgenol 163:1069–1072 Fisher U, Vossherich R, Kopka L, Keating D, Oestmann J, Grabbe E (1994) Dissection of the thoracic aorta: pre- and postoperative findings of turbo-FLASH MR images in the plane of the aortic arch. Am J Roentgenol 163:1069–1072
33.
Zurück zum Zitat Krukemberg E (1920) Beiträge zur Frage des Aneurysma dissecans. Beitr Pathol Anat Allg Pathol 67:329–351 Krukemberg E (1920) Beiträge zur Frage des Aneurysma dissecans. Beitr Pathol Anat Allg Pathol 67:329–351
34.
Zurück zum Zitat Fattori R, Bertaccini P, Celletti F et al (1997) Intramural post-traumatic hematoma of the ascending aorta in a patient with a double aortic arch. Eur Radiol 7:51–53PubMedCrossRef Fattori R, Bertaccini P, Celletti F et al (1997) Intramural post-traumatic hematoma of the ascending aorta in a patient with a double aortic arch. Eur Radiol 7:51–53PubMedCrossRef
35.
Zurück zum Zitat Nienaber CA, von Kodolitsch Y, Petersen B et al (1995) Intramural hemorrhage of the thoracic aorta: diagnostic and therapeutic implication. Circulation 92:1465–1472PubMed Nienaber CA, von Kodolitsch Y, Petersen B et al (1995) Intramural hemorrhage of the thoracic aorta: diagnostic and therapeutic implication. Circulation 92:1465–1472PubMed
36.
Zurück zum Zitat Coady MA, Rizzo JA, Elefteriades JA (1999) Pathologic variants of thoracic aortic dissections: penetrating atherosclerotic ulcers and intramural hematomas. Cardiol Clin 17(4):637–657PubMedCrossRef Coady MA, Rizzo JA, Elefteriades JA (1999) Pathologic variants of thoracic aortic dissections: penetrating atherosclerotic ulcers and intramural hematomas. Cardiol Clin 17(4):637–657PubMedCrossRef
37.
Zurück zum Zitat Yamada T, Takamiya M, Naito H, Kozuka T, Nakajima N (1985) Diagnosis of aortic dissection without intimal rupture by X-ray computed tomography. Nippon Igaku Hoshasen Gakkai Zasshi 45(5):699–710PubMed Yamada T, Takamiya M, Naito H, Kozuka T, Nakajima N (1985) Diagnosis of aortic dissection without intimal rupture by X-ray computed tomography. Nippon Igaku Hoshasen Gakkai Zasshi 45(5):699–710PubMed
38.
Zurück zum Zitat Moore A , Oh J, Bruckman D et al (1999) Transesophageal echocardiography in the diagnosis and management of aortic dissection: an analysis of data from the International Registry of Aortic Dissection (IRAD). J Am Coll Cardiol 33–2(A):470A Moore A , Oh J, Bruckman D et al (1999) Transesophageal echocardiography in the diagnosis and management of aortic dissection: an analysis of data from the International Registry of Aortic Dissection (IRAD). J Am Coll Cardiol 33–2(A):470A
39.
Zurück zum Zitat Murray JG, Manisali M, Flamm SD et al (1997) Intramural hematoma of the thoracic aorta: MR imaging findings and their prognostic implications. Radiology 204:349–355PubMed Murray JG, Manisali M, Flamm SD et al (1997) Intramural hematoma of the thoracic aorta: MR imaging findings and their prognostic implications. Radiology 204:349–355PubMed
40.
Zurück zum Zitat Shennan T (1934) Dissecting aneurisms. Medical Research Council Special Report series no. 193, Medical Research Council, London Shennan T (1934) Dissecting aneurisms. Medical Research Council Special Report series no. 193, Medical Research Council, London
41.
Zurück zum Zitat Movsowitz HD, Lampert C, Jacobs LE, Kotler MN (1994) Penetrating atherosclerotic aortic ulcers. Am Heart 128:1210–1217CrossRef Movsowitz HD, Lampert C, Jacobs LE, Kotler MN (1994) Penetrating atherosclerotic aortic ulcers. Am Heart 128:1210–1217CrossRef
42.
Zurück zum Zitat Hayashi H, Matsuoka Y, Sakamoto I, Sueyoshi E, Okimoto T, Hayashi K, Matsunaga N (2000) Penetrating atherosclerotic ulcer of the aorta: imaging features and disease concept. Radiographics 20(4):995–1005PubMed Hayashi H, Matsuoka Y, Sakamoto I, Sueyoshi E, Okimoto T, Hayashi K, Matsunaga N (2000) Penetrating atherosclerotic ulcer of the aorta: imaging features and disease concept. Radiographics 20(4):995–1005PubMed
43.
Zurück zum Zitat Yucel EK, Steinberg FL, Egglin TK, Geller SC, Waltman AC, Athanasoulis CA (1990) Penetrating atherosclerotic ulcers: diagnosis with MR imaging. Radiology 177:779–781PubMed Yucel EK, Steinberg FL, Egglin TK, Geller SC, Waltman AC, Athanasoulis CA (1990) Penetrating atherosclerotic ulcers: diagnosis with MR imaging. Radiology 177:779–781PubMed
44.
Zurück zum Zitat Fann JI, Smith JA, Miller CD et al (1995) Surgical management of aortic dissection during a 30 year period. Circulation 92(suppl II):110–121 Fann JI, Smith JA, Miller CD et al (1995) Surgical management of aortic dissection during a 30 year period. Circulation 92(suppl II):110–121
45.
Zurück zum Zitat Svensson LG, Crawford SE (1997) Statistical analyses of operative results. In: Cardiovascular and vascular disease of the aorta. Saunders, Philedelphia, pp 432–455 Svensson LG, Crawford SE (1997) Statistical analyses of operative results. In: Cardiovascular and vascular disease of the aorta. Saunders, Philedelphia, pp 432–455
46.
Zurück zum Zitat Fattori R, Bacchi Reggiani ML, Bertaccini P et al (2000) Evolution of aortic dissection after surgical repair. Am J Cardiol 86(8):868–872PubMedCrossRef Fattori R, Bacchi Reggiani ML, Bertaccini P et al (2000) Evolution of aortic dissection after surgical repair. Am J Cardiol 86(8):868–872PubMedCrossRef
47.
Zurück zum Zitat Moore NR, Parry AJ, Trottman-Dickenson B, Pillay R, Westaby S (1996) Fate of the native aorta after repair of acute type A dissection: a magnetic resonance imaging study. Heart 75:62–66PubMedCrossRef Moore NR, Parry AJ, Trottman-Dickenson B, Pillay R, Westaby S (1996) Fate of the native aorta after repair of acute type A dissection: a magnetic resonance imaging study. Heart 75:62–66PubMedCrossRef
48.
Zurück zum Zitat Mesana TG, Caus T, Gaubert J, Collart F, Ayari R, Bartoli J, Moulin G, Monties J (2000) Late complications after prosthetic replacement of the ascending aorta: What did we learn from routine magnetic resonance imaging follow-up? Eur J Cardio-Thorac Surg 18(3):313–320CrossRef Mesana TG, Caus T, Gaubert J, Collart F, Ayari R, Bartoli J, Moulin G, Monties J (2000) Late complications after prosthetic replacement of the ascending aorta: What did we learn from routine magnetic resonance imaging follow-up? Eur J Cardio-Thorac Surg 18(3):313–320CrossRef
49.
Zurück zum Zitat Kawamoto S, Bluemke DA, Traill TA, Zerhouni EA (1997) Thoracoabdominal aorta in Marfan syndrome: MR Imaging findings of progression of vasculopathy after surgical repair. Radiology 203:727–732PubMed Kawamoto S, Bluemke DA, Traill TA, Zerhouni EA (1997) Thoracoabdominal aorta in Marfan syndrome: MR Imaging findings of progression of vasculopathy after surgical repair. Radiology 203:727–732PubMed
50.
Zurück zum Zitat Gaubert J, Moulin G, Mesana T et al (1995) Type A dissection of the thoracic aorta: use of MR imaging for long term follow-up. Radiology 196:363–369 Gaubert J, Moulin G, Mesana T et al (1995) Type A dissection of the thoracic aorta: use of MR imaging for long term follow-up. Radiology 196:363–369
51.
Zurück zum Zitat Loubeyre P, Delignette A, Boneloy L, Douek P, Amiel M, Revel D (1996) MRI evaluation of the ascending aorta after graft-inclusion surgery: comparison between an ultra-fast contrast-enhanced MR sequence and conventional cine-MRI. JMRI 6:478–483PubMedCrossRef Loubeyre P, Delignette A, Boneloy L, Douek P, Amiel M, Revel D (1996) MRI evaluation of the ascending aorta after graft-inclusion surgery: comparison between an ultra-fast contrast-enhanced MR sequence and conventional cine-MRI. JMRI 6:478–483PubMedCrossRef
52.
Zurück zum Zitat Fattori R, Descovich B, Bertaccini P et al (1999) Composite graft replacement of the ascending aorta: leakage detection with gadolinium-enhanced MR imaging. Radiology 212:573–577PubMed Fattori R, Descovich B, Bertaccini P et al (1999) Composite graft replacement of the ascending aorta: leakage detection with gadolinium-enhanced MR imaging. Radiology 212:573–577PubMed
53.
Zurück zum Zitat Clouse WD, Hallett JW, Shaff HV, Gayari MM, Ilstrup DM, Melton LJ III (1998) Improved prognosis of thoracic aortic aneurysm: a population based study. JAMA 9(280):1926–1929CrossRef Clouse WD, Hallett JW, Shaff HV, Gayari MM, Ilstrup DM, Melton LJ III (1998) Improved prognosis of thoracic aortic aneurysm: a population based study. JAMA 9(280):1926–1929CrossRef
54.
Zurück zum Zitat Bonser RS, Pagano D, Lewis ME, Rooney SJ, Guest P, Davies P, Shimada I (2000) Clinical and patho-anatomical factors affecting expansion of thoracic aortic aneurysms. Heart 84(3):277–283PubMedCrossRef Bonser RS, Pagano D, Lewis ME, Rooney SJ, Guest P, Davies P, Shimada I (2000) Clinical and patho-anatomical factors affecting expansion of thoracic aortic aneurysms. Heart 84(3):277–283PubMedCrossRef
55.
Zurück zum Zitat Yamada N, Okita Y, Minatoya K et al (2000) Preoperative demonstration of the Adamkiewicz artery by magnetic resonance angiography in patients with descending or thoracoabdominal aortic aneurysms. Eur J Cardio-Thorac Surg 18(1):104–111CrossRef Yamada N, Okita Y, Minatoya K et al (2000) Preoperative demonstration of the Adamkiewicz artery by magnetic resonance angiography in patients with descending or thoracoabdominal aortic aneurysms. Eur J Cardio-Thorac Surg 18(1):104–111CrossRef
56.
Zurück zum Zitat Fattori R, Celletti F, Bertaccini et al (1996) Delayed surgery of traumatic aortic rupture: role of magnetic resonance imaging. Circulation 94:2865–2870PubMed Fattori R, Celletti F, Bertaccini et al (1996) Delayed surgery of traumatic aortic rupture: role of magnetic resonance imaging. Circulation 94:2865–2870PubMed
57.
Zurück zum Zitat Fattori R, Celletti F, Descovich B et al (1998) Evolution of post traumatic aneurysm in the subacute phase: magnetic resonance imaging follow-up as a support of the surgical timing. Eur J Cardio-Thorac Surg 13:582–587CrossRef Fattori R, Celletti F, Descovich B et al (1998) Evolution of post traumatic aneurysm in the subacute phase: magnetic resonance imaging follow-up as a support of the surgical timing. Eur J Cardio-Thorac Surg 13:582–587CrossRef
58.
Zurück zum Zitat Choe YH, Kim DK, Koh EM, Do YS, Lee WR (1999) Takayasu arteritis: diagnosis with MR imaging and MR angiography in acute and chronic active stages. J Magn Reson Imaging 10(5):751–757PubMedCrossRef Choe YH, Kim DK, Koh EM, Do YS, Lee WR (1999) Takayasu arteritis: diagnosis with MR imaging and MR angiography in acute and chronic active stages. J Magn Reson Imaging 10(5):751–757PubMedCrossRef
59.
Zurück zum Zitat Berkmen T (1999) MR Angiography of aneurysms in Beçhet disease: a report of four cases. J Comput Assist Tomogr 1998:202–206 Berkmen T (1999) MR Angiography of aneurysms in Beçhet disease: a report of four cases. J Comput Assist Tomogr 1998:202–206
60.
Zurück zum Zitat Meller J, Grabbe E, Becker W, Vosshenrich R (2003) Value of F-18 FDG hybrid camera PET and MRI in early Takayasu aortitis. Eur Radiol 13(2):400–405PubMed Meller J, Grabbe E, Becker W, Vosshenrich R (2003) Value of F-18 FDG hybrid camera PET and MRI in early Takayasu aortitis. Eur Radiol 13(2):400–405PubMed
61.
Zurück zum Zitat Vanderschueren S, Buysschaert I, Mortelmans L, Blockmans D, Knockaert DC (2004) Comment on Meller et al.: value of F-18 FDG hybrid camera PET and MRI in early Takayasu aortitis. Eur Radiol 14(5):926–929. Author reply 928–929PubMedCrossRef Vanderschueren S, Buysschaert I, Mortelmans L, Blockmans D, Knockaert DC (2004) Comment on Meller et al.: value of F-18 FDG hybrid camera PET and MRI in early Takayasu aortitis. Eur Radiol 14(5):926–929. Author reply 928–929PubMedCrossRef
62.
Zurück zum Zitat Fayad ZA, Fallon JT, Shinnar M et al (1998) Noninvasive in vivo high resolution magnetic resonance imaging of atherosclerotic plaque in genetically engineered mice. Circulation 98:1541–1547PubMed Fayad ZA, Fallon JT, Shinnar M et al (1998) Noninvasive in vivo high resolution magnetic resonance imaging of atherosclerotic plaque in genetically engineered mice. Circulation 98:1541–1547PubMed
63.
Zurück zum Zitat Leiner T, Gerretsen S, Botnar R, Lutgens E, Cappendijk V, Kooi E, van Engelshoven J (2005) Magnetic resonance imaging of atherosclerosis. Eur Radiol 15(6):1087–1099PubMedCrossRef Leiner T, Gerretsen S, Botnar R, Lutgens E, Cappendijk V, Kooi E, van Engelshoven J (2005) Magnetic resonance imaging of atherosclerosis. Eur Radiol 15(6):1087–1099PubMedCrossRef
64.
Zurück zum Zitat Fayad ZA, Nahar T, Fallon JT et al (2000) In vivo magnetic resonance evaluation of atherosclerotic plaques in the human thoracic aorta: a comparison with transesophageal echocardiography. Circulation 101(21):2503–2509PubMed Fayad ZA, Nahar T, Fallon JT et al (2000) In vivo magnetic resonance evaluation of atherosclerotic plaques in the human thoracic aorta: a comparison with transesophageal echocardiography. Circulation 101(21):2503–2509PubMed
65.
Zurück zum Zitat Worthley SG, Helft G, Fuster V, Zaman AG, Fayad ZA, Fallon JT, Badimon JJ (2000) Serial in vivo MRI documents arterial remodeling in experimental atherosclerosis. Circulation 101(6):586–589PubMed Worthley SG, Helft G, Fuster V, Zaman AG, Fayad ZA, Fallon JT, Badimon JJ (2000) Serial in vivo MRI documents arterial remodeling in experimental atherosclerosis. Circulation 101(6):586–589PubMed
66.
Zurück zum Zitat Fayad ZA, Nahar T, Fallon JT, Goldman M, Aguinaldo JG, Badimon JJ, Shinnar M, Chesebro JH, Fuster V (2000) In vivo magnetic resonance evaluation of atherosclerotic plaques in the human thoracic aorta: a comparison with transesophageal echocardiography. Circulation 101(21):2503–2509PubMed Fayad ZA, Nahar T, Fallon JT, Goldman M, Aguinaldo JG, Badimon JJ, Shinnar M, Chesebro JH, Fuster V (2000) In vivo magnetic resonance evaluation of atherosclerotic plaques in the human thoracic aorta: a comparison with transesophageal echocardiography. Circulation 101(21):2503–2509PubMed
67.
Zurück zum Zitat Chan SK, Jaffer FA, Botnar RM, Kissinger KV, Goepfert L, Chuang ML, O'Donnell CJ, Levy D, Manning WJ (2001) Scan reproducibility of magnetic resonance imaging assessment of aortic atherosclerosis burden. J Cardiovasc Magn Reson 3(4):331–338PubMedCrossRef Chan SK, Jaffer FA, Botnar RM, Kissinger KV, Goepfert L, Chuang ML, O'Donnell CJ, Levy D, Manning WJ (2001) Scan reproducibility of magnetic resonance imaging assessment of aortic atherosclerosis burden. J Cardiovasc Magn Reson 3(4):331–338PubMedCrossRef
68.
Zurück zum Zitat Ruehm SG, Corot C, Vogt P, Kolb S, Debatin JF (2001) Magnetic resonance imaging of atherosclerotic plaque with ultrasmall superparamagnetic particles of iron oxide in hyperlipidemic rabbits. Circulation 103(3):415–422PubMed Ruehm SG, Corot C, Vogt P, Kolb S, Debatin JF (2001) Magnetic resonance imaging of atherosclerotic plaque with ultrasmall superparamagnetic particles of iron oxide in hyperlipidemic rabbits. Circulation 103(3):415–422PubMed
69.
Zurück zum Zitat Schmitz SA, Taupitz M, Wagner S, Wolf KJ, Beyersdorff D, Hamm B (2001) Magnetic resonance imaging of atherosclerotic plaques using superparamagnetic iron oxide particles. J Magn Reson Imaging 14(4):355–361PubMedCrossRef Schmitz SA, Taupitz M, Wagner S, Wolf KJ, Beyersdorff D, Hamm B (2001) Magnetic resonance imaging of atherosclerotic plaques using superparamagnetic iron oxide particles. J Magn Reson Imaging 14(4):355–361PubMedCrossRef
70.
Zurück zum Zitat Yu X, Song SK, Chen J, Scott MJ, Fuhrhop RJ, Hall CS, Gaffney PJ, Wickline SA, Lanza GM (2000) High-resolution MRI characterization of human thrombus using a novel fibrin-targeted paramagnetic nanoparticle contrast agent. Magn Reson Med 44(6):867–872PubMedCrossRef Yu X, Song SK, Chen J, Scott MJ, Fuhrhop RJ, Hall CS, Gaffney PJ, Wickline SA, Lanza GM (2000) High-resolution MRI characterization of human thrombus using a novel fibrin-targeted paramagnetic nanoparticle contrast agent. Magn Reson Med 44(6):867–872PubMedCrossRef
71.
Zurück zum Zitat Toussaint J, Southern JF, Fuster V, Kantor HL (1994) 13-NMR spectroscopy of Human atherosclerotic lesions: relation between fatty acid saturation, cholesteryl ester content and luminal obstruction. Circulation 14: 1951–1957 Toussaint J, Southern JF, Fuster V, Kantor HL (1994) 13-NMR spectroscopy of Human atherosclerotic lesions: relation between fatty acid saturation, cholesteryl ester content and luminal obstruction. Circulation 14: 1951–1957
72.
Zurück zum Zitat Chen JW, Pham W, Weissleder R, Bogdanov A Jr (2004) Human myeloperoxidase: a potential target for molecular MR imaging in atherosclerosis. Magn Reson Med 52(5):1021–1028PubMedCrossRef Chen JW, Pham W, Weissleder R, Bogdanov A Jr (2004) Human myeloperoxidase: a potential target for molecular MR imaging in atherosclerosis. Magn Reson Med 52(5):1021–1028PubMedCrossRef
73.
Zurück zum Zitat Zimmermann-Paul GG, Quick HH, Vogt P, von Schulthess GK, King D, Debatin JF (1999) High resolution intravascular magnetic resonance imaging: monitoring of plaque formation in heritable hyperlipidemic rabbits. Circulation 99:1054–1061PubMed Zimmermann-Paul GG, Quick HH, Vogt P, von Schulthess GK, King D, Debatin JF (1999) High resolution intravascular magnetic resonance imaging: monitoring of plaque formation in heritable hyperlipidemic rabbits. Circulation 99:1054–1061PubMed
74.
Zurück zum Zitat Farrar CT, Wedeen VJ, Ackerman JL (2005) Cylindrical meanderline radiofrequency coil for intravascular magnetic resonance studies of atherosclerotic plaque. Magn Reson Med 53(1):226–230PubMedCrossRef Farrar CT, Wedeen VJ, Ackerman JL (2005) Cylindrical meanderline radiofrequency coil for intravascular magnetic resonance studies of atherosclerotic plaque. Magn Reson Med 53(1):226–230PubMedCrossRef
75.
Zurück zum Zitat Glowinski A, Adam G, Bucker A, Neuerburg J, van Vaals JJ, Gunther RW (1997) Catheter visualization using locally induced, actively controlled field inhomogeneities. Magn Reson Med 38(2):253–258PubMedCrossRef Glowinski A, Adam G, Bucker A, Neuerburg J, van Vaals JJ, Gunther RW (1997) Catheter visualization using locally induced, actively controlled field inhomogeneities. Magn Reson Med 38(2):253–258PubMedCrossRef
76.
Zurück zum Zitat Bakker CJ, Smits HF, Bos C, van der Weide R, Zuiderveld KJ, van Vaals JJ, Hurtak WF, Viergever MA, Mali WP (1998) MR-guided balloon angioplasty: in vitro demonstration of the potential of MRI for guiding, monitoring, and evaluating endovascular interventions. J Magn Reson Imaging 8(1):245–250PubMedCrossRef Bakker CJ, Smits HF, Bos C, van der Weide R, Zuiderveld KJ, van Vaals JJ, Hurtak WF, Viergever MA, Mali WP (1998) MR-guided balloon angioplasty: in vitro demonstration of the potential of MRI for guiding, monitoring, and evaluating endovascular interventions. J Magn Reson Imaging 8(1):245–250PubMedCrossRef
77.
Zurück zum Zitat Godart F, Beregi JP, Nicol L, Occelli B, Vincentelli A, Daanen V, Rey C, Rousseau J (2000) MR-guided balloon angioplasty of stenosed aorta: in vivo evaluation using near-standard instruments and a passive tracking technique. J Magn Reson Imaging 12(4):639–944PubMedCrossRef Godart F, Beregi JP, Nicol L, Occelli B, Vincentelli A, Daanen V, Rey C, Rousseau J (2000) MR-guided balloon angioplasty of stenosed aorta: in vivo evaluation using near-standard instruments and a passive tracking technique. J Magn Reson Imaging 12(4):639–944PubMedCrossRef
Metadaten
Titel
Acquired diseases of the thoracic aorta: role of MRI and MRA
verfasst von
Vincenzo Russo
Matteo Renzulli
Katia Buttazzi
Rossella Fattori
Publikationsdatum
01.04.2006
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 4/2006
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-0028-x

Weitere Artikel der Ausgabe 4/2006

European Radiology 4/2006 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.